Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Hierarchical Phased-Array Antennas Coupled to Al KIDs: A Scalable Architecture for Multi-band Millimeter/Submillimeter Focal Planes

We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot dipole antennas, split into 4 frequency bands (between 125 GHz and 365 GHz) with on-chip lumped-element band-pass filters, and routed to different KIDs using microstriplines. Individual pixels detect light for the 3 higher-frequency bands (190–365 GHz), and the signals from four individual pixels are coherently summed to create a larger pixel detecting light for the lowest frequency band (125–175 GHz). The spectral response of the band-pass filters was measured using Fourier transform spectroscopy (FTS), the far-field beam pattern of the phased-array antennas was obtained using an infrared source mounted on a 2-axis translating stage, and the optical efficiency of the KIDs was characterized by observing loads at 294 K and 77 K. We report on the results of these three measurements.

47 OTHER INSTRUMENTATION↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

CUORE: The first bolometric experiment at the ton scale for the search for neutrino-less double beta decay

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most massive bolometric experiment searching for neutrino-less double beta (0νββ) decay. The detector consists of an array of 988 TeO 2 crystals (742 kg) arranged in a compact cylindrical structure of 19 towers. Here, this paper will describe the CUORE experiment, including the cryostat, and present the detector performance during the first year of running. Additional detail will describe the effort made in improving the energy resolution in the 130 Te 0νββ decay region of interest (ROI) and the suppression of backgrounds. A description of work to lower the energy threshold in order to give CUORE the sensitivity to search for other rare events, such as dark matter, will also be provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Operating Temperature Midwave Quantum Dot Barrier Infrared Detector (QD-BIRD)

The nBn or XBn barrier infrared detector has the advantage of reduced dark current resulting from suppressed Shockley-Read-Hall (SRH) recombination and surface leakage. High performance detectors and focal plane arrays (FPAs) based on InAsSb absorber lattice matched to GaSb substrate, with a matching AlAsSb unipolar electron barrier, have been demonstrated. The band gap of lattice-matched InAsSb yields a detector cutoff wavelength of approximately 4.2 ??m when operating at ~150K. We report results on extending the cutoff wavelength of midwave barrier infrared detectors by incorporating self-assembled InSb quantum dots into the active area of the detector. Using this approach, we were able to extend the detector cutoff wavelength to ~6 ?m, allowing the coverage of the full midwave infrared (MWIR) transmission window. The quantum dot barrier infrared detector (QD-BIRD) shows infrared response at temperatures up to 225 K.

quantum dot↗

Lightning mapping sensor study

A technology assessment to determine how a world-wide, continuous measurement of lightning could be achieved from a geostationary platform is provided. Various approaches to the detector sensors are presented. It was first determined that any existing detector chips would require some degree of modification in order to meet the lightning mapper sensor requirements. The elements of the system were then analyzed, categorized, and graded for study emphasis. The recommended approach for the lightning mapper sensor is to develop a monolithic array in which each detector cell has circuitry that implements a two-step photon-collecting method for a very high dynamic range with good measurement accuracy. The efficiency of the array is compatible with the use of a conventional refractive optics design having an aperture in the neighborhood of 7 to 10 cm.

Norwood, V.↗

Low-background InSb array development

Photovoltaic indium antimonide (PV InSb) detector technology has matured over the past several years to enable a wide variety of applications to use this high-performance detector material to advantage. The operating conditions for most of the applications to date for back-side illuminated PV InSb arrays have encompassed focal plane temperatures ranging from 40 to approximately 95 K, with the majority in the narrower range between 60 and 80 K. Background flux conditions have ranged from 10 to the 10th power ph/sq cm/sec to 10 to the 16th power ph/sq cm/sec, most typically between 10 to the 12th power and 10 to the 14th power ph/sq cm/sec. Appropriately, the array parameters were optimized for maximum performance over these temperature and background ranges. The key parameters which were peaked in this process were the resistance-area product of the detectors and their quantum efficiency. The Space Infrared Telescope Facility (SIRTF) Infrared Array Camera requirements, however, present very low temperature and background operating conditions, plus the need for very high signal to noise ratios. Preliminary analysis indicates that back-side illuminated PV InSb arrays can be optimized for operation under these conditions, and some performance projections will be presented.

Thom, R. D.↗

Performance of the QWIP Focal Plane Arrays for NASA's Landsat Data Continuity Mission

The focal plane assembly for the Thermal Infrared Sensor (TIRS) instrument on NASA's Landsat Data Continuity Mission (LDCM) consists of three 512 x 640 GaAs Quantum Well Infrared Photodetector (QWIP) arrays. The three arrays are precisely mounted and aligned on a silicon carrier substrate to provide a continuous viewing swath of 1850 pixels in two spectral bands defined by filters placed in close proximity to the detector surfaces. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). QWIP arrays were evaluated from four laboratories; QmagiQ, (Nashua, NH), Army Research Laboratory, (Adelphi, MD}, NASA/ Goddard Space Flight Center, (Greenbelt, MD) and Thales, (Palaiseau, France). All were found to be suitable. The final discriminating parameter was the spectral uniformity of individual pixels relative to each other. The performance of the QWIP arrays and the fully assembled, NASA flight-qualified, focal plane assembly will be reviewed. An overview of the focal plane assembly including the construction and test requirements of the focal plane will also be described.

Jhabvala, M.↗

GaN/AlGaN Avalanche Photodiode Detectors for High Performance Ultraviolet Sensing Applications

The shorter wavelengths of the ultraviolet (UV) band enable detectors to operate with increased spatial resolution, variable pixel sizes, and large format arrays, benefitting a variety of NASA, defense, and commercial applications. AlxGa1-xN semiconductor alloys, which have attracted much interest for detection in the UV spectral region, have been shown to enable high optical gains, high sensitivities with the potential for single photon detection, and low dark current performance in ultraviolet avalanche photodiodes (UV-APDs). We are developing GaN/AlGaN UV-APDs with large pixel sizes that demonstrate consistent and uniform device performance and operation. These UV-APDs are fabricated through high quality metal organic chemical vapor deposition (MOCVD) growth on lattice-matched, low dislocation density GaN substrates with optimized material growth and doping parameters. The use of these low defect density substrates is a critical element to realizing highly sensitive UV-APDs and arrays with suppressed dark current under high electric fields.Optical gains greater than 5X10 (exp 6) with enhanced quantum efficiencies over the 350-400 nm spectral range have been demonstrated, enabled by a strong avalanche multiplication process. Furthermore, we are developing 6X6 arrays of devices to test high gain UV-APD array performance at ~355 nm. These variable-area GaN/AlGaN UV-APD detectors and arrays enable advanced sensing performance over UV bands of interest with high resolution detection for NASA Earth Science applications.

Sood, Ashok K.↗

Search for PeV Gamma-Ray Emission from the Southern Hemisphere with 5 Yr of Data from the IceCube Observatory

The measurement of diffuse PeV gamma-ray emission from the Galactic plane would provide information about the energy spectrum and propagation of Galactic cosmic rays, and the detection of a pointlike source of PeV gamma-rays would be strong evidence for a Galactic source capable of accelerating cosmic rays up to at least a few PeV. This paper presents several unbinned maximum-likelihood searches for PeV gamma-rays in the Southern Hemisphere using 5 yr of data from the IceTop air shower surface detector and the in-ice array of the IceCube Observatory. The combination of both detectors takes advantage of the low muon content and deep shower maximum of gamma-ray air showers and provides excellent sensitivity to gamma-rays between ~0.6 and 100 PeV. Our measurements of pointlike and diffuse Galactic emission of PeV gamma-rays are consistent with the background, so we constrain the angle-integrated diffuse gamma-ray flux from the Galactic plane at 2 PeV to 2.61 × 10 -19 cm -2 s -1 TeV -1 at 90% confidence, assuming an E -3 spectrum, and we estimate 90% upper limits on pointlike emission at 2 PeV between 10 -21 and 10 -20 cm -2 s -1 TeV -1 for an E -2 spectrum, depending on decl. Furthermore, we exclude unbroken power-law emission up to 2 PeV for several TeV gamma-ray sources observed by the High Energy Spectroscopic System and calculate upper limits on the energy cutoffs of these sources at 90% confidence. We also find no PeV gamma-rays correlated with neutrinos from IceCube's high-energy starting event sample. Lastly, these are currently the strongest constraints on PeV gamma-ray emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of a Hybrid Transition Edge Sensor Array for Lynx

Lynx is a proposed NASA X-Ray telescope flight mission aimed at achieving state-of-the-art angular and energy resolution with a 100 kilopixel array to probe the hot energetic young universe in unprecedented detail. To achieve these goals, our team plans on leveraging our current work in development of the focal plane for the Athena X-Ray Integral Field Unit (X-IFU) while advancing the state-of-the-art in transition edge sensor (TES) X-ray detector technology. The TES is an optimal technology for achieving both high energy and fine angular resolution at the same time because pixel features can be made extremely small and the absorber which dominates the heat capacity can be tuned to meet resolution requirements. Specifically, the proposed mission concept calls for a hybrid detector of three different arrays fabricated in the same planar process in one focal plane and optimized for different science goals. The main arrays consist of 5x5 hydras, 25 pixels of 4 micron thick Au absorbers each with a different thermal link to one common TES. The outer array has absorbers on a 50-micron pitch for most of the 5 arc-minute field-of-view, and the inner array has 25-micron absorbers for the central 1 arc-minute region. A high resolution array consisting of single pixel 1 micron thick Au absorbers on 50-micron pitch will lie off to the side. Reading out an array of this magnitude will likely require improvements in indium bump bonding to superconducting flexible wiring. Fabrication of absorbers of two different sizes requires electroplating through a photoresist mold by careful tuning of the current density to achieve uniform flat absorbers on a fine pitch scale, followed by ion milling to yield narrow streets separating the pixels while preserving high quantum efficiency. We report on progress made at fabricating the hybrid array with different absorber sizes and thicknesses. Further, we also report on ongoing work to adequately heat sink the pixels with backside wire bonding and copper coating. We also report on work to improve detector pixel yield and top side indium bump bonding to flexible wiring.

Focal plane array↗

Characterization of the Superconducting Microwave Properties of Aluminum Manganese

A microwave kinetic inductance detector (MKID) is a superconducting pair breaking detector that offers a number of unique advantages for realizing large-format arrays of ultra-sensitive detectors, such as inherent multiplexibility and relative ease of fabrication. With the detection threshold being set by the Cooper pair binding energy, and correspondingly, the superconducting critical temperature (T c ), typically well-understood MKID materials such as aluminum (Al) present a lower limit on the operating frequency. Aluminum manganese (Al-Mn) is a promising candidate material for MKIDs because it can be fabricated with nearly identical processing as pure Al, but allows for control of the T c , with varying levels of Mn doping or post-deposition heat treatment. In this study, we present initial results from an early characterization of AlMn using a series of lumped-element superconducting microwave resonators, including measurements of T c , internal quality factor, and noise performance over a range of Mn doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

Space Based Gravitational Wave Observatories (SGOs)

Space-based Gravitational-wave Observatories (SGOs) will enable the systematic study of the frequency band from 0.0001 - 1 Hz of gravitational waves, where a rich array of astrophysical sources is expected. ESA has selected The Gravitational Universe as the science theme for the L3 mission opportunity with a nominal launch date in 2034. This will be at a minimum 15 years after ground-based detectors and pulsar timing arrays announce their first detections and at least 18 years after the LISA Pathfinder Mission will have demonstrated key technologies in a dedicated space mission. It is therefore important to develop mission concepts that can take advantage of the momentum in the field and the investment in both technology development and a precision measurement community on a more near-term timescale than the L3 opportunity. This talk will discuss a mission concept based on the LISA baseline that resulted from a recent mission architecture study.

Gravitational-wave↗

System and method for compact, adaptive optical sensor for obtaining areal images

The present disclosure relates to an imaging system which may make use of an electronic controller, a digital micromirror array, an aperture control system and a detector to image a desired scene. The digital micromirror array has a plurality of micromirror elements responsive to control signals generated by the electronic controller for electronically aiming the micromirror elements in a desired direction to image the desired area, and for receiving and reflecting light emanating from the desired area. The aperture control system receives light reflected from the digital micromirror array and passes a predetermined subportion of the received light therethrough. The detector is responsive to the predetermined subportion of light.

Panas, Robert Matthew↗

The C shell, an active detector of UH nuclei

This paper gives a brief description of the current status of the present program to develop a modular array of large electronic particle detectors. These modules were designed to study the UH nuclei in the cosmic radiation with eventual deployment on the Space Station or at a lunar base. This array would determine the abundances of elements from iron to the actinides and directly measure the energies of the lower energy nuclei. If the array was deployed on the Space Station, it would use the geomagnetic threshold to place limits on the higher energy nuclei, thus studying the energy spectrum up to about 10 GeV/n. Deployed at a lunar base, it would detect nuclei with energies down to the instrumental limit. Smaller versions could be flown on balloons to test and refine the modules.

Waddington, C. J.↗

Passive and active neutron signatures of 233 U for nondestructive assay

The thorium fuel cycle is emerging as an attractive alternative to conventional nuclear fuel cycles, as it does not require the enrichment of uranium for long-term sustainability. The operating principle of this fuel cycle is the irradiation of 232 Th to produce 233 U, which is fissile and sustains the fission chain reaction. 233 U poses unique challenges for nuclear safeguards, as it is associated with a uniquely extreme γ-ray environment from 232 U contamination, which limits the feasibility of the γ-ray-based assay, as well as more conservative accountability requirements than for 235 U set by the International Atomic Energy Agency. Consequently, instrumentation used for safeguarding 235 U in traditional fuel cycles may be inapplicable. It is essential that the nondestructive signatures of 233 U be characterized so that nuclear safeguards can be applied to thorium fuel-cycle facilities as they come online. In this work, a set of 233 U 3 O 8 plates, containing 984 g 233 U, was measured at the National Criticality Experiments Research Center. A high-pressure 4 He gaseous scintillation detector, which is insensitive to γ-rays, was used to perform a passive fast neutron spectral signature measurement of 233 U 3 O 8 , and was used in conjunction with a pulsed deuterium-tritium neutron generator to demonstrate the differential die-away signature of this material. Furthermore, an array of 3 He detectors was used in conjunction with the same neutron generator to measure the delayed neutron time profile of 233 U, which is unique to this nuclide. These measurements provide a benchmark for future nondestructive assay instrumentation development, and demonstrate a set of key neutron signatures to be leveraged for nuclear safeguards in the thorium fuel cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗