Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Power distribution estimation method for SMR using ex-core detectors: experimental demonstration by plural control rod patterns at KUCA

The power distribution estimation method based on the ex-core detectors, or PHOEBE, was demonstrated at Kyoto University Critical Assembly, KUCA. Generally, core monitoring systems use in-core neutron detectors. Since inside the core is a harsh environment, the maintainability and reliability of the detectors are deteriorated. On the other hand, the environment outside the core is milder: core monitoring by the ex-core detectors improves the maintainability and reliability especially for small modular reactors and micro-reactors. However, neutron information from the inner region of the core is lost at the ex-core detectors. To recover the information, the authors proposed to utilize the power correlation between the fuel regions. PHOEBE concept was demonstrated at KUCA with distorted power distributions simulated by control rod patterns. The relative power distribution estimated by PHOEBE agreed with that calculated by Monte Carlo simulation code MVP. PHOEBE approximately reproduced the trend of the distorted power distributions calculated by MVP code. By contrast, the case of without power correlation between fuel regions produced significant different power distributions. Therefore, the advantage of considering the power correlation between fuel regions was also demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast Scanning Diamond Detector for Electron Beam Profile Monitoring

The first prototype of a fast scanning diamond beam profile detector (DBPD) suitable for invasive high power CW electron beam core profile measurements in transmittance mode was developed. It consists of a multi-strip solid state diamond detector to scan with high speed (up to 1 m/s) and precision (about 5 μm) through the core of an electron beam. The diamond sensor was made from a thin polycrystalline diamond (PCD) plate with highly B-doped diamond conductive strips both grown by CVD. Transient currents from the multi-strip detector were measured with fast digitizing electrometers. Successful operation of the DBPD was demonstrated for pulsed (5 Hz) and CW (78 kHz) CeC beams, including the detector’s ability to withstand a 20 sec insertion into the CW CeC beam core. The X-Y beam spatial profile was measured in one scan. Thermal modelling demonstrated a manageable thermal impact even from a relatively long insertion of the diamond sensor into the CW CeC core and very short (0.2 s) insertion into the CW LEReC beam core. Electrical impedance modelling of the detector and vacuum chamber assembly demonstrated minimal impact on beam line impedance with diamond sensor insertion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing Novel CR-39 Detector Deployment System for Identification of Subsurface Fractures, Soda Springs, ID

The Environmental Protection Agency (EPA) has teamed with Battelle Energy Alliance, LLC (BEA) at Idaho National Laboratory (INL) to facilitate further testing of geologic-fracture-identification methodology at a field site near the Monsanto Superfund Site located in Soda Springs, Idaho. INL has the necessary testing and technological expertise to perform this work. Battelle Memorial Institute (BMI) has engaged INL to perform this work through a Work for Others (WFO) Agreement. This study continues a multi-year collaborative effort between INL and EPA to test the efficacy of using field deployed Cr-39 radon in soil portals. This research enables identification of active fractures capable of transporting contaminants at sites where fractures are suspected pathways into the subsurface. Current state of the art methods for mapping fracture networks are exceedingly expensive and notoriously inaccurate. The proposed WFO will evaluate the applicability of using cheap, readily available, passive radon detectors to identify conductive geologic structures (i.e. fractures, and fracture networks) in the subsurface that control the transport of contaminants at fracture-dominated sites. The proposed WFO utilizes proven off-the-shelf technology in the form of CR-39 radon detectors, which have been widely deployed to detect radon levels in homes and businesses. In an existing collaborative EPA/INL study outside of this workscope, CR-39 detectors are being utilized to determine the location of active transport fractures in a fractured granitic upland adjacent to a landfill site at the Fort Devens, MA that EPA-designated as National Priorities List (NPL) site. The innovative concept of using an easily deployed port that allows the CR-39 to measure the Rn-222 in the soil or alluvium above the fractured rock, while restricting atmospheric Rn-222 and soil sourced Ra from contaminating the detector is unique to INL and EPA approach previously developed. By deploying a series of these inexpensive detector-casing combinations statistical samples of the Rn-222 flux can be measured, elucidating the most communicative fractures (i.e. fractures that are actively transporting water and gasses). The Rn-222 measurements can then be used as an input to create a more accurate conceptual model to be used for transport modeling and related cleanup activities. If the team’s approach is demonstrated to be applicable to a wide variety of rock types and soil conditions it might potentially offer significant cost saving without a reduction in data quality at Monsanto Superfund and other sites underlain by fracture-dominated bedrock.

58 GEOSCIENCES↗

Search for New Phenomena Using W/Z + (b)-Jets Measurements Performed with the ATLAS Detector

The Project proposed to use data of the ATLAS experiment, obtained during the 2011 and 2012 data-taking campaigns, to pursue studies of the strong interaction (QCD) and to examine promising signatures for new physics. The Project also contains a service component dedicated to a detector development initiative. The objective of the strong interaction studies is to determine how various predictions from the main theory (QCD) compare to the data. Results of a set of measurements developed by the Tufts team indicate that the dominant factor of discrepancy between data and QCD predictions come from the mis-modeling of the low energy gluon radiation as described by algorithms called parton showers. The discrepancies introduced by parton showers on LHC predictions could even be larger than the effect due to completely new phenomena (dark matter, supersymmetry, etc.) and could thus block further discoveries at the LHC. Some of the results obtained in the course of this Project also specify how QCD predictions must be improved in order to open the possibility for the discovery of something completely new at the LHC during Run-II. This has been integrated in the Run-II ATLAS physics program. Another objective of Tufts studies of the strong interaction was to determine how the hypothesis about an intrinsic heavy-quark component of the proton (strange, charm or bottom quarks) could be tested at the LHC. This hypothesis has been proposed by theorists 30 years ago and is still controversial. The Tufts team demonstrated that intrinsic charms can be observed, or severely constrained, at the LHC, and determine how the measurement should be performed in order to maximize its sensitivity to such an intrinsic heavy-quark component of the proton. Tufts also embarked on performing the measurement that is in progress, but final results are not yet available. They should shade a light of understanding on the fundamental structure of the proton. Determining the nature of dark matter particles, composing about 25% of all the matter in the universe, is one of the most exciting research goals at the LHC. Within this Project, the Tufts team proposed a way to improve over the standard approach used to look for dark matter at the LHC in events involving jets and a large amount of unbalanced energy in the detector (jets+ETmiss). The Tufts team has developed a measurement to test these improvements on data available (ATLAS 2012 dataset), in order to be ready to apply them on the new Run-II data that will be available at the end of 2015. Preliminary results on the proposed measurement indicate that a very high precision can be obtained on results free of detector effects. That will allow for better constrains of dark matter theories and will spare the needs for huge computing resources in order to compare dark matter theories to data. Finally, the Tufts team played a leading role in the development and the organization of the 6Et trigger, the detector component needed to collect the data used in dark matter searches and in many other analyses. The team compared the performance of the various algorithms capable of reconstructing the value of the ETmiss on each LHC collision event, and developed a strategy to commission these algorithms online. Tufts also contributed in the development of the ETmiss trigger monitoring software. Finally, the PI of this Project acted as the co-coordinator of the group of researchers at CERN taking care of the development and the operation of this detector component. The ETmiss trigger is now taking data, opening the possibility for the discovery of otherwise undetectable particles at the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of Chemical Etching and Chemo-Mechanical Polishing on CdZnTe Nuclear Detectors

Cadmium zinc telluride (CdZnTe) semiconductor has applications in the detection of Xrays and gamma-rays at room temperature without having to use a cooling system. Chemical etching and chemo-mechanical polishing are processes used to smoothen CdZnTe wafer during detector device fabrication. These processes reduce surface damages left after polishing the wafers. In this paper, we compare the effects of etching and chemo-mechanical polishing on CdZnTe nuclear detectors, using a solution of hydrogen bromide in hydrogen peroxide and ethylene glycol mixture. X-ray photoelectron spectroscopy (XPS) was used to monitor TeO 2 on the wafer surfaces. Current-voltage and detector-response measurements were made to study the electrical properties and energy resolution. XPS results showed that the chemical etching process resulted in the formation of more TeO 2 on the detector surfaces compared to chemo-mechanical polishing. The electrical resistivity of the detector is of the order of 10 10 Ω-cm. The chemo-mechanical polishing process increased the leakage current more that chemical etching. For freshly treated surfaces, the etching process is more detrimental to the energy resolution more than chemo-mechanically polishing. The energy resolutions of the CdZnTe wafers are expected to improve as the surfaces stabilize and result in reduced surface currents.

36 MATERIALS SCIENCE↗

Multidirectional Cosmic Ray Ion Detector for Deep Space CubeSats

Understanding the nature of anisotropy of solar energetic protons (SEPs) and galactic cosmic ray (GCR) fluxes in the interplanetary medium is crucial in characterizing time-dependent radiation exposure in interplanetary space for future exploration missions. NASA Glenn Research Center has proposed a CubeSat-based instrument to study solar and cosmic ray ions in lunar orbit or deep space. The objective of Solar Proton Anisotropy and Galactic cosmic ray High Energy Transport Instrument (SPAGHETI) is to provide multi-directional ion data to further understand anisotropies in SEP and GCR flux. The instrument is to be developed using large area detectors fabricated from high density, high purity silicon carbide (SiC) to measure linear energy transfer (LET) of ions. Stacks of these LET detectors are arranged in a CubeSat at orthogonal directions to provide multidirectional measurements. The low-noise, thermally-stable nature of silicon carbide and its radiation tolerance allows the multidirectional array of detector stacks to be packed in a 6U CubeSat without active cooling. A concept involving additional coincidence/anticoincidence detectors and a high energy Cherenkov detector is possible to further expand ion energy range and sensitivity.

Extraterrestrial Radiation↗

Superconducting kinetic inductance photon detectors.

We are investigating a novel superconducting detector and readout method that could lead to photon counting, energy resolving focal plane arrays. This concept is intrinsically different from STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution in the ptical/UV/X-ray bands. The readout uses the monotonic relation between the kinetic surface inductance L***subs***, of a superconductor and the density of quasiparticles n, which holds even at temperatures far below T***subc***. This allows a sensitive readout of the number of excess quasiparticles in the detector by monitoring the transmission phase of a resonant circuit. The most intriguing aspect of this concept is that passive frequency multiplexing could be used to read out ~ l0***super4*** detectors with a single HEMT amplifier. Single x-ray events have been observed in prototype detectors.

kinetic↗

Two-Dimensional Interdigitated Pixel Detector for Energetic Particle Spectrometers

This paper describes a type of cosmic ray detector suitable for the construction of a small, low power space-based instrument to detect the energy and isotope of energetic nuclei, such as those produced by solar flares. The detector is similar to previous types of silicon PIN detectors where the fully depleted body of the wafer comprises intrinsic region of the PIN structure. The novel aspect of this detector is that the one surface is divided into a two-dimensional array of pixels, and that the collected holes are divided between a row and a column collector in each pixel, yielding both dimensions of position information from this side of the detector.

cosmic↗

Mid-infrared detector development for the Origins Space Telescope

Mid-infrared detector arrays operating from 2.8 to 20 μm are baselined in the design of the Origins Space Telescope Mid-Infrared Spectrometer Instrument. This instrument is designed to detect and measure the spectral signatures of gases of biogenic origin in the atmospheres of exoplanets as they transit their host stars. In order to make these detections, the detector array’s pixels need to have high-signal stability when exposed to a constant flux in multiple time-series integration over a typical transit time of a few hours. With the use of a densified pupil spectrometer design, pointing effects can be mitigated because pointing variations do not displace spectra on the detector and each wavelength of light is averaged over a large number of pixels, giving good spectrophotometric stabilities. The current state-of-the-art detector arrays do not achieve these stabilities, although with a feasible development program this level of performance should be achievable. Three detector technologies are under consideration for this development, HgCdTe arrays, Si:As impurity band conduction arrays, and transition edge super-conductor bolometer arrays. We primarily treat the HgCdTe technology development, but also introduce the paths forward for the other two technologies. After a few years-long investigative programs, a down-select will be undertaken to select the flight technology.

Astronomy↗

Determining the Quantum Detection Efficiency of A Soft X-Ray Micro-Channel Plate Detector for the Lunar Mission, LEXI

Micro-channel plate (MCP) detectors have long been a workhorse for space-based x-ray research and are advantageous over other imaging detectors because of their low size, weight and power. The Lunar Environment heliospheric x-ray Imager (LEXI), will utilize a MCP to image Earth’s magnetosphere in soft x-rays from the lunar surface. A critical element for interpreting on-orbit data is to understand the quantum detection efficiency (QDE) of the MCP. LEXI’s MCP is coated with potassium bromide (KBr) to increase the soft x-ray QDE. Historically, few measurements of QDE exist in the soft x-ray band for KBr detectors. This paper reviews the performance of LEXI’s detector, and the QDE experiment procedure conducted at and results from the Advanced Light Source synchrotron soft x-ray beam line (6.3.2) over the energy range 70eV-1300eV. A unique beam line setup was required to limit the photon flux as to not saturate the pores of the MCP or detector signal chain. The experimental results are similar to previous literature, with some caveats unique to this MCP and experimental setup.

X-ray imaging↗

Estimation of Performance of an Active Well Coincidence Counter Equipped with Boron-Coated Straw Neutron Detectors - 13401

He-3, a very rare isotope of natural helium gas, has ideal properties for the detection of thermal neutrons. As such it has become the standard material for neutron detectors and sees ubiquitous use within many radiometric applications that require neutron sensitivity. Until recently, there has been a fairly abundant supply of He-3. However, with the reduction in nuclear weapons, production of tritium ceased decades ago and the stockpile has largely decayed away, reducing the available He-3 supply to a small fraction of that needed for neutron detection. A suitable and rapidly-deployable replacement technology for neutron detectors must be found. Many potential replacement technologies are under active investigation and development. One broad class of technologies utilizes B-10 as a neutron capture medium in coatings on the internal surfaces of proportional detectors. A particular implementation of this sort of technology is the boron-coated 'straw' (BCS) detectors under development by Proportional Technologies, Inc. (PTi). This technology employs a coating of B-10 enriched boron carbide (B{sub 4}C) on the inside of narrow tubes, roughly 4 mm in diameter. A neutron counter (e.g. a slab, a well counter, or a large assay counter designed to accommodate 200 liter drums) could be constructed by distributing these narrow tubes throughout the polyethylene body of the counter. One type of neutron counter that is of particular importance to safeguards applications is the Active Well Coincidence Counter (AWCC), which is a Los Alamos design that traditionally employs 42 He-3 detectors. This is a very flexible design which can accurately assay small samples of uranium- and plutonium-bearing materials. Utilizing the MCNPX code and benchmarking against measurements where possible, the standard AWCC has been redesigned to utilize the BCS technology. Particular aspects of the counter performance include the single-neutron ('singles') detection efficiency and the time constant for the decrease in neutron population in the counter following a fission event (a.k.a. the die-away time). Results of the modeling and optimization are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic readout techniques for germanium detectors

High Purity Germanium detectors are used in many applications, from nuclear and astro-particle physics, to homeland security or environment protection. Although quite standard configurations are often used, with cryostats, charge sensitive amplifiers and analog or digital acquisition systems all commercially available, it might be the case that a few specific applications, e.g. satellites, portable devices, cryogenic physics experiments, etc. also require the development of a few additional or complementary techniques. An interesting case is for sure GERDA, the Germanium Detector Array experiment, searching for neutrino-less double beta decay of {sup 76}Ge at the Gran Sasso National Laboratory of INFN - Italy. In GERDA the entire detector array, composed of semi-coaxial and BEGe naked crystals, is operated suspended inside a cryostat filled with liquid argon, that acts not only as cooling medium and but also as an active shield, thanks to its scintillation properties. These peculiar circumstances, together with the additional requirement of a very low radioactive background from all the materials adjacent to the detectors, clearly introduce significant constraints on the design of the Ge front-end readout electronics. All the Ge readout solutions developed within the framework of the GERDA collaboration, for both Phase I and Phase II, will be briefly reviewed, with their relative strength and weakness compared together and with respect to ideal Ge readout. Finally, the digital processing techniques developed by the GERDA collaboration for energy estimation of Ge detector signals will be recalled. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simple Way to Overcome the Shortage of {sup 3}He Detectors in the IPEN/MB-01 Nuclear Reactor

The presented work shows the preliminary results of an experimental procedure to overcome the helium-3 detectors shortage in the IPEN/MB-01 nuclear reactor and be feasible the study of the high subcritical states with less sensitivity detectors. The main principle was employing the input logic nuclear module which was possible to execute logic operations with the neutron signals. Though these signals was possible to construct the Auto Power Spectral Densities (APSD) and obtain the Prompt Neutron Constant Decay (α). Two different kinds of thermal neutron detectors were used ({sup 3}He and BF{sub 3}). The arrangement was initially constituted by one of each type detector and, posteriorly, for a more complete data acquisition, in groups of two detectors for all subcritical configurations. The experiment was carried out using the control banks (BC-1 and BC-2) insertion to achieve all the subcritical states studied in this work. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diamond dose rate detector testing at KURRI- A joint UK-Japan research project - 17126

Measurements of radiation dose rates in highly active environments, such as nuclear plant decommissioning or following a nuclear disaster, is challenging due to the extreme environments encountered and restricted access. Therefore, novel radiation detector technology is required to address these challenges. One such example of a radiation detection material is diamond, as it is able to withstand and measure high radiation intensities, is chemically inert and formable into extremely small, sensitive detectors. These detectors generate small currents when exposed to radiation, and if the radiation levels are high enough this can be measured. Testing of such detectors is not possible in routine laboratories due to the requirement to have high active radiation sources. However, through a new collaboration formed through the University of Bristol- Kyoto University bilateral symposia such facilities are accessible for UK researchers at Kyoto University Research Reactor Institute. This paper presents an overview of the collaborative research project, the accessible facilities for device manufacture and testing and some early results from radiation testing of diamond detectors at KURRI. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Collimated CZT Detector for Quantitative Gamma Assays - 17250

Cadmium-Zinc-Telluride [CZT] detectors for gamma spectroscopic measurements and room-temperature operation have had a long history of promising good performance. Very small detectors [0.05-0.5 cm{sup 3}] have been commercially available for many years, but their small size creates problems for spectroscopy because of very low photopeak efficiency, especially at medium and high energies. Large CZT [4-6 cm{sup 3}] detectors have been shown to work nicely in a research environment when complicated electronic and data processing algorithms are applied. We report here test results from a commercially available 1 cubic centimeter CZT detector housed in a portable custom Tungsten shield with a set of collimators with different apertures. The detector has 2-2.5% FWHM resolution at Cs-137 energies, and near-Gaussian shaped peaks. Efficiency calibrations can be quickly made for a wide variety of geometries using the ISOCS mathematical efficiency software. We show successful validation tests comparing accuracy of measurements on reference calibration point sources, line sources, and 200 liter drums. The low weight of the device [9 kg including the shield and collimator] and low power [powered via USB from the PC] makes these devices particularly suitable for human-deployed in-situ measurements of large objects containing medium levels of activity - e.g. characterization of objects encountered during decommissioning, emergency response, truck alarm investigation, or waste being shipped to a disposal facility. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability

Neutron measurement technology is critical to the detection and identification of nuclear materials and sources. Portable neutron detectors that enable thermal neutron and fast neutron measurements with a single system are still an experimental area. The ability to employ three signatures (photons, thermal neutrons, and fast neutrons) simultaneously for identification provides an extra element of certainty in results. The energy of fast neutrons can also provide a unique spectral signature for source quantification. A phoswich detector is based on the use of two dissimilar scintillators with a single photomultiplier tube (PMT) for the purpose of radiation detection. Past development was focused primarily on the application of the multi-scintillator design to gamma-ray, alpha- and beta-particle measurements. To this end, the work presented here has focused on the development of a phosphor sandwich ('phoswich') detector capable of differentiating between photons, thermal neutrons, and fast neutrons. The portable phoswich neutron detector was designed using two solid-sate scintillators: the {sup 6}Li-loaded glass and the EJ-299-33A plastic. Experiments showed that detector provides simultaneously count rates of photons, thermal neutrons, and fast neutrons with the energy spectroscopy option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗