Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Error analysis in the measurement of average power with application to switching controllers

Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.

Maisel, J. E.↗

An Updated Look at the Pro K Experiment: Urinary Acid Excretion Can Predict Changes in Bone Metabolism During Space Flight

Mitigating space flight-induced bone loss is critical for space exploration, and diet can play a major role in this effort (1). Previous ground-based studies provide evidence that dietary composition can influence bone resorption during bed rest (2). In this study we examined the role of dietary intake patterns as one factor that can influence bone mineral loss in astronauts during space flight. Crew members were asked to consume, for 4 days at a time, prescribed menus with either a low (0.3-0.6 g/mEq) or high (1.0-1.3 g/mEq) ratio of animal protein to potassium (APro:K). Menus were developed for each crewmember, and were designed to meet both crew preferences and study constraints. Intakes of energy, total protein, calcium, and sodium were held relatively constant between the two diets. The order of the menus was randomized, and crews completed each set (low and high) once before and twice during space flight, for a total of 6 controlled diet sessions. One inflight session and three postflight sessions (R+30, R+180, R+365) monitored typical dietary intake. As of this writing, data are available from 14 crew members. Two subject's samples are awaiting return from ISS via Space-X, and the final subject has one more collection session planned in November 2014. On the last day of each of the 4-d controlled diet sessions, 24-h urine samples were collected, along with a fasting blood sample on the morning of the 5th day. Preliminary analyses will show the relationships between diet and flight on markers of bone metabolism. The results from this study, which represent healthy individuals in a unique environment, will be important to better understand diet and bone interrelationships during space flight as well as on Earth. These data will be important as nutritional requirements and food systems are developed for future exploration-class missions. This study was funded by the Human Health Countermeasures Element of NASA Human Research Program.

Zwart, Sara R.↗

Unmanned solar systems exploration - An arena for international cooperation

Mission profiles for a Mars Surface Sample Return (MSSR) mission are considered. A profile using separate launches for a lander/ascent module and an orbiter/return system could use present technology and is appropriate for international cooperation. The achievement of clean interfaces between major building blocks and ease of controlling back contamination are advantages offered by the concept. A spatially distributed surface sample could be obtained by using multiple landers delivering samples to a common orbiter. The Pioneer Venus program, originally planned as a cooperative NASA-ESRO project, resulted in development of a standardized spacecraft bus yielding benefits at minimized cost. The first joint US-European planetary mission now planned is the launch of a Pioneer class orbiter to Jupiter in 1980. Feasibility studies are being conducted.

Herman, D. H.↗

Non-Targeted Effects and the Dose Response for Heavy Ion Tumorigenesis

BACKGROUND: There is no human epidemiology data available to estimate the heavy ion cancer risks experienced by astronauts in space. Studies of tumor induction in mice are a necessary step to estimate risks to astronauts. Previous experimental data can be better utilized to model dose response for heavy ion tumorigenesis and plan future low dose studies. DOSE RESPONSE MODELS: The Harderian Gland data of Alpen et al.[1-3] was re-analyzed [4] using non-linear least square regression. The data set measured the induction of Harderian gland tumors in mice by high-energy protons, helium, neon, iron, niobium and lanthanum with LET s ranging from 0.4 to 950 keV/micron. We were able to strengthen the individual ion models by combining data for all ions into a model that relates both radiation dose and LET for the ion to tumor prevalence. We compared models based on Targeted Effects (TE) to one motivated by Non-targeted Effects (NTE) that included a bystander term that increased tumor induction at low doses non-linearly. When comparing fitted models to the experimental data, we considered the adjusted R2, the Akaike Information Criteria (AIC), and the Bayesian Information Criteria (BIC) to test for Goodness of fit.In the adjusted R2test, the model with the highest R2values provides a better fit to the available data. In the AIC and BIC tests, the model with the smaller values of the summary value provides the better fit. The non-linear NTE models fit the combined data better than the TE models that are linear at low doses. We evaluated the differences in the relative biological effectiveness (RBE) and found the NTE model provides a higher RBE at low dose compared to the TE model. POWER ANALYSIS: The final NTE model estimates were used to simulate example data to consider the design of new experiments to detect NTE at low dose for validation. Power and sample sizes were calculated for a variety of radiation qualities including some not considered in the Harderian Gland data set and with different background tumor incidences. We considered different experimental designs with varying number of doses and varying low doses dependant on the LET of the radiation. The optimal design to detect a NTE for an individual ion had 4 doses equally spaced below a maximal dose where bending due to cell sterilization was < 2%. For example at 100 keV/micron we would irradiate at 0.03 Gy, 0.065 Gy, 0.13 Gy, and 0.26 Gy and require 850 mice including a control dose for a sensitivity to detect NTE with 80% power. Sample sizes could be improved by combining ions similar to the methods used with the Harderian Gland data.

Chappelli, Lori J.↗

A Pipeline for Assessing the Quality of Rna-Seq Datasets in GeneLab

Transcriptome profiling by RNA sequencing (RNA-seq) is a powerful approach to identify gene expression changes in organisms exposed to unique environments such as spaceflight. One of the challenges of evaluating RNA-seq data both within and across different space-relevant studies is the ability to control for technical differences, including the use of different library preparation kits, sequencing platforms, RNA yield, and person-to-person variation. To help address this issue, the National Institute of Standards and Technology (NIST, nist.gov) initiated a consortium, at the request of industry and academia, to develop a set of controls for gene expression measurements. The result was a set of 92 unlabeled, polyadenylated transcripts that range from 250 – 2,000 nucleotides in length to mimic natural eukaryotic mRNAs. These External RNA Controls Consortium (ERCC) genes can be used in any RNA-seq experiment, by adding known concentrations of the ERCC genes to samples after RNA extraction, to offer a standard measurement for data comparison. At NASA GeneLab, we employ these controls as part of our standard operating procedures for every in-house RNA-seq study to assess the limit of detection, dynamic range, and power of differential expression analysis both within and across experiments. Here we will discuss the use, benefits, and limitations of ERCC genes and other types of controls, such as universal RNA references, to generate quality control information for RNA-seq studies conducted at GeneLab.

GeneLab↗

A Recent Volcanic Eruption, Holuhraun, in the Central Highlands of Iceland as a Mars analog: The 2018 Field Campaign of FELDSPAR

In summer 2018, FELDSPAR conducted an analog sampling expedition to the Holuhraun volcanoin the central highlands of Iceland that erupted from August 2014 to February 2015. Holuhraun hassteep gradients within an otherwise relatively controlled region, and thus served as the primaryMars analog site for the 2018 FELDSPAR field campaign. Samples along gradients of mineralogyas measured via near-IR and visible reflectance spectroscopy, temperature as measured by an IRprobe, and physical location about the fissure (slope incline, directionality, height up the slope,etc.) were analyzed in-field with reflectance spectroscopy and X-ray fluorescence, in the field labfor adenosine trisphosphate (ATP) as an indicator of metabolic activity, and after return to thehome lab for both geochemical and geophysical parameters (moisture content, grain size, X-raydiffraction) and biochemical parameters (DNA content and speciation). This abstract representsthe first report on the 2018 field campaign with initial results and interpretation. This work is part ofField Exploration and Life Detection Sampling for Planetary Analogue Research (FELDSPAR), onFacebook @FELDSPAResearch.

Volcanic↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/temperature/humidity (FIFH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Integrated Attitude Control Strategy for the Asteroid Redirect Mission

A deep-space mission has been proposed to redirect an asteroid to a distant retrograde orbit around the moon using a robotic vehicle, the Asteroid Redirect Vehicle (ARV). In this orbit, astronauts will rendezvous with the ARV using the Orion spacecraft. The integrated attitude control concept that Orion will use for approach and docking and for mated operations will be described. Details of the ARV's attitude control system and its associated constraints for redirecting the asteroid to the distant retrograde orbit around the moon will be provided. Once Orion is docked to the ARV, an overall description of the mated stack attitude during all phases of the mission will be presented using a coordinate system that was developed for this mission. Next, the thermal and power constraints of both the ARV and Orion will be discussed as well as how they are used to define the optimal integrated stack attitude. Lastly, the lighting and communications constraints necessary for the crew's extravehicular activity planned to retrieve samples from the asteroid will be examined. Similarly, the joint attitude control strategy that employs both the Orion and the ARV attitude control assets prior, during, and after each extravehicular activity will also be thoroughly discussed.

Lopez, Pedro, Jr.↗

Generating Real-Time Robotics Control Software from SysML

In this paper, we outline an approach for autogenerating real-time robotics control code from hierarchical state machines and hardware configurations encoded in Systems Modeling Language (SysML). We propose a software architecture that provides an abstract SysML layer with access to device state information and a set of primitive device commands, such as move actuator and release brake, allowing a user to build up a complete functional state machine directly in SysML. The SysML diagram is then exported to a standard SCXML file format and subsequently used to auto-generate hardware control code. Once this architecture is in place, the only explicit code elements that need to be written are the primitive device commands, which can be easily unit tested and reused across different systems. The motivation for this work was the need for a test bed that enables the rapid prototyping of mechanisms and control algorithms for a spacecraft that could ultimately be used for preparing Martian rock samples for their return to Earth. To this end, our software system was also designed to allow for the run-time specification of the hardware layout in SysML, with the hardware-level control functions kept agnostic to the specific parameters or communication bus of any particular device. Further, we outline a system for specifying both the state machine and hardware configuration in the MagicDraw IDE in such a way that the system can be simulated before any code is generated. The resultant software system is easy to debug, understand, and allows users to choose how much information is encoded as a visual or text-based representation.

Godart, Peter↗

The laboratory module

Of the five modules comprising the Orbiting Quarantine Facility, the Laboratory Module must provide not only an extensive research capability to permit execution of the protocol, but also the flexibility to accommodate second-order testing if nonterrestrial life is discovered in the sample. The biocontainment barriers that protect the sample and the researchers from cross contamination are described. Specifically, the laboratory layout, laboratory equipment, the environmental control and life support system, and containment assurance procedures are discussed. The metal manipulation arm proposed for use within the biocontainment cabinets is described. Sample receipt and processing procedures are outlined.

Source record↗

Cardiac morphology after conditions of microgravity during Cosmos 2044

Light- and electron-microscopic studies were performed on cardiac muscle from rats flown on Cosmos 2044 and from four control groups. Average cross-sectional area of myofibers was measured by video analysis of the light-microscopic images of papillary and ventricular muscle samples from all animals. This cross-sectional area was significantly decreased in flight rats (P = 0.03) compared with synchronous controls. Additional findings at the electron microscopic level consistent with this atrophy were obtained by stereological analysis and optical diffraction analysis of papillary muscle samples. Slightly higher mitochondrial volume density values and mitochondria-to-myofibril ratios as well as normal A-band spacings (d1,0) and Z-band spacings of myofibrils were observed in the tail-suspension and flight groups. General morphological features similar to those in ventricular samples from the previous Cosmos 1887 flight were observed.

Goldstein, Margaret A.↗

Autoignition test cell with flexible atmosphere control

Spontaneous combustion temperatures are usually found by simply beating material until it bursts into flames. Test cell allows control of test atmosphere and composition. Reusable device permits periodic sampling of decomposition products in test atmosphere. With modifications, cell could be used to determine melting points and reactivites of wide variety of substances.

Evans, D.↗

DONAR - A computer processing system to extend ultrasonic pulse-echo testing.

A dedicated general purpose digital computer has been built on the principle of a sampled-data system to run an ultrasonic subsystem under programmed control. A most significant application is the ability to extract a signal from an interfering background. As illustrated in the paper, a 1 mm diameter transducer was used to measure the diameter of a 2.5 mm OD plastics tube with 0.4 mm wall thickness. Echoes from all four surfaces were displayed and the measurements indicated an uncertainty of less than 0.1 mm.

Lees, S.↗

Application LANDSAT imagery to geologic mapping in the ice-free valleys of Antarctica

The author has identified the following significant results. Studies in the Ice-Free Valleys are resulted in the compilation of a sizeable library of maps and publications. Rock reflectance measurements were taken during the Antarctic summer of 1973. Spectral reflectance of rocks (mostly mafic lava flows) in the McMurdo and Ice-Free Valleys areas were measured using a filter wheel photometer equipped to measure reflectances in the four Landsat bands. A series of samples were collected at regular intervals across a large differentiated, mafic sill near Lake Vida. Chemical analyses of the sample suggest that the tonal variations in this sill are controlled by changes in the iron content of the rock. False color images were prepared for a number of areas by the diazo method and with an optical multispectral biviewer. These images were useful in defining boundaries of sea ice, snow cover, and in the study of ablating glaciers, but were not very useful for rock discrimination.

Houston, R. S.↗

LACIE performance predictor final operational capability program description, volume 3

The requirements and processing logic for the LACIE Error Model program (LEM) are described. This program is an integral part of the Large Area Crop Inventory Experiment (LACIE) system. LEM is that portion of the LPP (LACIE Performance Predictor) which simulates the sample segment classification, strata yield estimation, and production aggregation. LEM controls repetitive Monte Carlo trials based on input error distributions to obtain statistical estimates of the wheat area, yield, and production at different levels of aggregation. LEM interfaces with the rest of the LPP through a set of data files.

Source record↗

Analysis of bilinear noise models in circuits and devices

There are a number of applications in which linear noise models are inappropriate. In the paper, the use of bilinear noise models in circuits and devices is considered. Several physical problems are studied in this framework. These include circuits involving varying parameters (such as variable resistance circuits constructed using field-effect transistors), the effect of switching jitter on sampled data system performance and communication systems involving voltage-controlled oscillators and phase-lock loops. In addition, several types of analytical techniques for stochastic bilinear systems are considered. Specifically, the moment equations of Brockett for bilinear systems driven by white noise are discussed, and closed-form expressions for certain bilinear systems (those that evolve an Abelian or solvable Lie groups) driven by white or colored noise are derived. In addition, an approximate statistical technique involving the use of harmonic expansions is described.

Willsky, A. S.↗

Infrared spectrometer for Voyager

The Voyager IR investigation is described, which uses a Michelson interferometer in the 180-2500/cm range, and a single-channel radiometer for the visible and near-IR, sharing a 50-cm diameter telescope. Emphasis is placed on the differences between the Voyager and the previous designs, including reductions in the field of view and in the noise equivalent spectral radiance of the instrument. Attention is given to the optical layout, the electronics module, power supply placement, thermal control heaters and flash heaters, data reduction, and calibration. A sample spectrum of Jupiter is also discussed.

Hanel, R.↗