Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Analytical design and evaluation of an active control system for helicopter vibration reduction and gust response alleviation

An analytical study was conducted to define the basic configuration of an active control system for helicopter vibration and gust response alleviation. The study culminated in a control system design which has two separate systems: narrow band loop for vibration reduction and wider band loop for gust response alleviation. The narrow band vibration loop utilizes the standard swashplate control configuration to input controller for the vibration loop is based on adaptive optimal control theory and is designed to adapt to any flight condition including maneuvers and transients. The prime characteristics of the vibration control system is its real time capability. The gust alleviation control system studied consists of optimal sampled data feedback gains together with an optimal one-step-ahead prediction. The prediction permits the estimation of the gust disturbance which can then be used to minimize the gust effects on the helicopter.

Taylor, R. B.↗

Controlled cooling and crystallization of a eucrite - Microprobe studies

The paper presents microprobe data on controlled cooling experiments on the eucrite meteorite Stannern, with emphasis on pyroxene zoning and chemistry, development of immiscible liquids in the mesostasis, and compositional boundary layer development adjacent to crystals. Controlled cooling rate experiments on melted samples of the meteorite yield a variety of petrographic textures that can be related to the cooling rate. Textures of clasts in Stannern suggest natural cooling rates of .1 to 100 C/hr for various clasts in the meteorite. Residual liquids are found to unmix at temperatures below about 990 C at moderate cooling rates. Results indicate that Stannern's pyroxenes have evidently undergone subsolidus internal cation exchange, thereby removing Fe-Mg variation in pyroxenes, lowering Al contents, and promoting exosolution.

Powell, M. A.↗

Polymers in solar energy utilization

A laser photoacoustic technique (LPAT) has been verified for performing accelerated life testing of outdoor photooxidation of polymeric materials used in solar energy applications. Samples of the material under test are placed in a chamber with a sensitive microphone, then exposed to chopped laser radiation. The sample absorbs the light and converts it to heat by a nonradiative deexcitation process, thereby reducing pressure fluctuations within the cell. The acoustic signal detected by the microphone is directly proportional to the amount of light absorbed by the specimen. Tests were performed with samples of ethylene/methylacrylate copolymer (EMA) reprecipitated from hot cyclohexane, compressed, and molded into thin (25-50 microns) films. The films were exposed outdoors and sampled by LPAT weekly. The linearity of the light absorbed with respect to the acoustic signal was verified.Correlations were established between the photoacoustic behavior of the materials aged outdoors and the same kinds of samples cooled and heated in a controlled environment reactor. The reactor tests were validated for predicting outdoor exosures up to 55 days.

Liang, R. H.↗

Fast Dual Analog-to-Digital Converter

Unit delivers blocks of quadrature data to computer memory. Contains 105 integrated circuit packages in 19 by 3 1/2 inch (48.26 by 8.39 cm) rack mounted drawer with internal force air blower. Intended for synchronous sampling of quadrature pairs of data, samples with minimal skew (about 10 nanoseconds) using video-type high-speed sampling technology. Unit equipped for computer controlled self-testing. Originally developed for planetary radar data-acquisition system.

Wallis, D. E.↗

Solar absorptance and thermal emittance of some common spacecraft thermal-control coatings

Solar absorptance and thermal emittance of spacecraft materials are critical parameters in determining spacecraft temperature control. Because thickness, surface preparation, coatings formulation, manufacturing techniques, etc. affect these parameters, it is usually necessary to measure the absorptance and emittance of materials before they are used. Absorptance and emittance data for many common types of thermal control coatings, are together with some sample spectral data curves of absorptance. In some cases for which ultraviolet and particle radiation data are available, the degraded absorptance and emittance values are also listed.

Henninger, J. H.↗

Highly automated transmission-edge mapping

Instrumentation and software are described, which are used to determine maps of properties of materials based on optical transmission spectra. In addition to a Fourier transform spectrometer, the hardware includes an xy-stage containing a small stationary aperture and two computer controlled stepper motors for positioning the sample. This idea has been used for years but this implementation is highly automated compared to those previously described. All mapping has been in the 2-15 micron wavelength range but this is not an inherent limitation of the technique. In this spectral range, useful results may be obtained with apertures as small as 25 microns in diameter. The software is described including the algorithm for obtaining the cut-on wavelength from a semiconductor spectrum. Data from both transverse slices and longitudinal slabs of narrow bandgap alloy semiconductors are shown including composition maps for materials solidified with convex and concave growth interfaces.

Szofran, F. R.↗

Experimental results on atomic oxygen corrosion of silver

The results of an experimental study of the reaction kinetics of silver with atomic oxygen in 10 degree increments over the temperature range of 0 to 70 C is reported. The silver specimens, of the order of 10,000 A in thickness, were prepared by thermal evaporation onto 3 inch diameter polished silicon wafers. There were later sliced into pieces having surface areas of the order of 1/4 to 1/2 square inch. Atomic oxygen was generated by a gas discharge in a commercial plasmod asher operating in the megahertz frequency range. The sample temperature within the chamber was controlled by means of a thermoelectric unit. Exposure of the silver specimens to atomic oxygen was incremental, with oxide film thickness measurements being carried out between exposures by means of an automated ellipsometer. For the early growth phase, the data can be described satisfactorily by a logarithmic growth law: the oxide film thickness increases as the logarithm of the exposure time. Furthermore, the oxidation process is thermally activated, the rate increasing with increasing temperature. However, the empirical activation energy parameter deduced from Arrhenius plots is quite low, being of the order of 0.1 eV.

Fromhold, Albert T.↗

Characterization of blood drawn rapidly for use in blood volume expansion studies: An animal model for simulated weightlessness

It was demonstrated that up to 8ml of blood can be drawn from donar rats without significantly increasing volume and stress sensitive hormones, and thus can be used for volume expansion studies. Infusion of whole blood allows more physiological changes that can be seen with volume expansion by saline or other ionic solutions. The infusion of whole blood to induce hypervolemia may provide an improved model to study the fluid balance and control mechanisms operative in weightlessness. Blood samples were drawn as quickly as possible from femoral artery catheters chronically implanted in Sprague Dawley rats and analyzed for hematocrit, plasma sodium, potassium, osmolality, corticosterone, epinepherine, norepinephrine, and vasopressin. The levels were found to be comparable to those of normal rats.

Chenault, V. Michelle↗

Fiber-Coupled Acousto-Optical-Filter Spectrometer

Fiber-coupled acousto-optical-filter spectrometer steps rapidly through commanded sequence of wavelengths. Sample cell located remotely from monochromator and associated electronic circuitry, connected to them with optical fibers. Optical-fiber coupling makes possible to monitor samples in remote, hazardous, or confined locations. Advantages include compactness, speed, and no moving parts. Potential applications include control of chemical processes, medical diagnoses, spectral imaging, and sampling of atmospheres.

Levin, Kenneth H.↗

Differential Scanning Calorimetry (DSC) for planetary surface exploration

Differential Scanning Calorimetry (DSC) is the quantitative measurement of the enthalpic response of a material to a systematic change in temperature. In practice, the heat flow into or outward from a sample is measured as the sample is heated or cooled at a carefully controlled rate. DSC superficially resembles, but is not the same as differential thermal analysis (DTA), which is the measurement of temperature differences between a sample and reference material as the pair is heated or cooled. The fundamental properties measured by DSC are enthalpies and temperatures of phase transitions and constant-pressure heat capacities. Depending on instrument design and the nature of the sample, high-quality DSC analyses can be obtained on only a few milligrams of solid materials. DSC requires direct contact with the sample and generally degrades, if not destroys, the sample as a consequence of heating. In laboratory applications, it is common to subject the gaseous effluent from the DSC to analysis by a separate evolved-gas analyzer (EGA).

Gooding, James L.↗

The extensional rheology of non-Newtonian materials

It has been proposed to measure the extensional viscosity function of a non-Newtonian polymer solution in a reduced gravity environment as part of the Advanced Fluid Module. In ground-based extensional measurements, the no-sip boundary condition at solid-fluid interfaces always result in appreciable shear gradients in the test fluid; however the removal of gravitational body forces permits controlled extensional deformation of containerless test samples and the first unambiguous measurements of this kind. Imperative to successful implementation of this experiment is the generation and subsequent deformation of a stable cylindrical column of test fluid. A study of the generation and deformation of liquid bridges demonstrates that Newtonian liquid bridges undergo capillary breakup as anticipated when stretched beyond a critical aspect ratio; non-Newtonian liquid bridges, however, are stabilized by the strain-hardening phenomenon exhibited by these materials. Numerical simulations of Newtonian breakup are compared with experimental results, and show that previous ground-based attempts at measuring the extensional viscosity of Newtonian fluids are of limited accuracy.

Spiegelberg, Stephen H.↗

International Test Program for Synergistic Atomic Oxygen and VUV Exposure of Spacecraft Materials

Spacecraft in low Earth orbit (LEO) are subject to degradation in thermal and optical performance of components and materials through interaction with atomic oxygen and vacuum ultraviolet radiation which are predominant in LEO. Due to the importance of LEO durability and performance to manufacturers and users, an international test program for assessing the durability of spacecraft materials and components was initiated. Initial tests consisted of exposure of samples representing a variety of thermal control paints and multilayer insulation materials that have been used in space. Materials donated from various international sources were tested alongside a material whose performance is well known such as Teflon FEP or Kapton H for multilayer insulation, or Z-93-P for white thermal control paints. The optical, thermal or mass loss data generated during the test was then provided to the participating material supplier. Data was not published unless the participant donating the material consented to publication. This paper presents a description of the types of tests and facilities that have been used for the test program as well as some examples of data that have been generated. The test program is intended to give spacecraft builders and users a better understanding of degradation processes and effects to enable improved prediction of spacecraft performance.

Rutledge, Sharon↗

Device Control Using Gestures Sensed from EMG

In this paper we present neuro-electric interfaces for virtual device control. The examples presented rely upon sampling Electromyogram data from a participants forearm. This data is then fed into pattern recognition software that has been trained to distinguish gestures from a given gesture set. The pattern recognition software consists of hidden Markov models which are used to recognize the gestures as they are being performed in real-time. Two experiments were conducted to examine the feasibility of this interface technology. The first replicated a virtual joystick interface, and the second replicated a keyboard.

Wheeler, Kevin R.↗

Disruption of postural readaptation by inertial stimuli following space flight

Postural instability (relative to pre-flight) has been observed in all shuttle astronauts studied upon return from orbital missions. Postural stability was more closely examined in four shuttle astronaut subjects before and after an 8 day orbital mission. Results of the pre- and post-flight postural stability studies were compared with a larger (n = 34) study of astronauts returning from shuttle missions of similar duration. Results from both studies indicated that inadequate vestibular feedback was the most significant sensory deficit contributing to the postural instability observed post flight. For two of the four IML-1 astronauts, post-flight postural instability and rate of recovery toward their earth-normal performance matched the performance of the larger sample. However, post-flight postural control in one returning astronaut was substantially below mean performance. This individual, who was within normal limits with respect to postural control before the mission, indicated that recovery to pre-flight postural stability was also interrupted by a post-flight pitch plane rotation test. A similar, though less extreme departure from the mean recovery trajectory was present in another astronaut following the same post-flight rotation test. The pitch plane rotation stimuli included otolith stimuli in the form of both transient tangential and constant centripetal linear acceleration components. We inferred from these findings that adaptation on orbit and re-adaptation on earth involved a change in sensorimotor integration of vestibular signals most likely from the otolith organs.

NASA Center JSC↗

International Test Program for Synergistic Atomic Oxygen and Vacuum Ultraviolet Radiation Exposure of Spacecraft Materials

The components and materials of spacecraft in low Earth orbit can degrade in thermal and optical performance through interaction with atomic oxygen and vacuum ultraviolet (VUV) radiation, which are predominant in low Earth orbit. Because of the importance of low Earth orbit durability and performance to manufacturers and users, an international test program for assessing the durability of spacecraft materials and components was initiated. Initial tests at the NASA Glenn Research Center consisted of exposure of samples representing a variety of thermal control paints, multilayer insulation materials, and Sun sensors that have been used in space. Materials donated from various international sources were tested alongside materials whose performance is well known, such as Teflon FEP, Kapton H, or Z-93-P white paint. The optical, thermal, or mass loss data generated during the tests were then provided to the participating material suppliers. Data were not published unless the participant donating the material consented to publication. The test program is intended to give spacecraft builders and users a better understanding of degradation processes and effects so that they can improve their predictions of spacecraft performance.

Miller, Sharon K.↗

Space Environment Effects on Stability of Medications Flown on Space Shuttles and the International Space Station (ISS)

The purpose is to assess physical and chemical degradation of select pharmaceutical formulations from the Shuttle and ISS medical kits. Eleven pharmaceuticals dispensed as different dosage forms were selected based on their physical / chemical characteristics and susceptibility to environmental factors such as, temperature, humidity and light sensitivity. When available, ground-controls of the study medications with matching brand and lot numbers were used for comparison. Samples retrieved from flight were stored along with their matching controls in a temperature and humidity controlled environmental chamber. Temperature, humidity, and radiation data from the Shuttle and ISS were retrieved from onboard HOBO U12 Temp/RH Data Loggers, and from passive dosimeters. Physical and chemical analyses of the pharmaceuticals were conducted using validated United States Pharmacopeia (USP) methods. Results indicated degradation of 6 of the 11 formulations returned from space flights. Four formulations, Amoxicillin / Clavulanate, promethazine, sulfamethoxazole / trimethoprim, and ciprofloxacin tablets depicted discoloration after flight. Chemical content analyses using High or Ultra Performance Liquid Chromatography (HPLC / UPLC) methods revealed that dosage forms of Amoxicillin / Clavulanate, promethazine, sulfamethoxazole / trimethoprim, lidocaine, ciprofloxacin and mupirocin contained less than 95% of manufacturer s labeled claim of active drug compound. Shuttle and ISS environments affect stability and shelf life of certain mediations flown on these missions. Data analysis is in progress to examine the effect of specific space flight environmental factors on pharmaceutical stability. The degradation profiles generated from ground studies in analog environments will be useful in establishing predictive shelf-life profiles for medications intended for use during long-term space exploration missions.

Daniels, Vernie↗

CHOICE - Directed Study: Consequences of longterm- Confinement and Hypobaric HypOxia on Immunity in the Antarctic Concordia Environment

Concerning ground-based space physiological research, the choice of analog must carefully match the system of interest. For spaceflight-associated immune dysregulation (SAID), Antarctica winter-over has emerged as potentially the best terrestrial analog. The prolonged mission durations, extreme/dangerous environment, station-based lifestyle, isolation from outside world, disrupted circadian rhythms, and other psychological aspects make this analog extremely high fidelity for exploration-class space missions (long duration lunar, Mars). NASA, ESA and RSA are currently investigating SAID, with NASA currently operating the Integrated Immune flight study. It is desirable to have a ground analog for SAID validated, so that potential countermeasures might be validated terrestrially prior to during flight. For this presentation, NASA data collected on the winterover 2009 crewmembers, baseline through early deployment will be presented. Through early deployment (approximately 2-3 weeks at Concordia), phenotypic alterations included increased levels of memory T cells, shifts among the CD8+ T cell compartment to a more mature phenotype, and increases in constitutively activated T cells. CD8+/IFNg+ T cell percentages, and T cell blastogenesis functional responses were depressed early deployment as compared to healthy controls. In four compatible subjects, secreted T cell Th1/Th2 cytokines were measured following culture stimulation, and a Th2 shift was observed as compared to controls. Post-winter over frozen sample return will be required to determine if this shift persisted during the winter over period. Additionally, circadian rhythms remained altered compared to baseline, as determined through 5x daily cortisol measurements. Latent viral reactivation will not be determined until frozen sample return occurs.

Sams, Clarence↗

Pulse-Flow Microencapsulation System

The pulse-flow microencapsulation system (PFMS) is an automated system that continuously produces a stream of liquid-filled microcapsules for delivery of therapeutic agents to target tissues. Prior microencapsulation systems have relied on batch processes that involve transfer of batches between different apparatuses for different stages of production followed by sampling for acquisition of quality-control data, including measurements of size. In contrast, the PFMS is a single, microprocessor-controlled system that performs all processing steps, including acquisition of quality-control data. The quality-control data can be used as real-time feedback to ensure the production of large quantities of uniform microcapsules.

Morrison, Dennis R.↗