Simulation of magnetic island dynamics under resonant magnetic perturbation with the TEAR code and validation of the results on T-10 tokamak data

Simulation of the magnetic island evolution under Resonant Magnetic Perturbation (RMP) in rotating T-10 tokamak plasma is presented with intent of TEAR code experimental validation. In the T-10 experiment chosen for simulation, the RMP consists of a stationary error field, a magnetic field of the eddy current in the resistive vacuum vessel and magnetic field of the externally applied controlled halo current in the plasma scrape-off layer (SOL). The halo-current loop consists of a rail limiter, plasma SOL, vacuum vessel, and external part of the circuit. Effects of plasma resistivity, viscosity, and RMP are taken into account in the TEAR code based on the two-fluid MHD approximation. Radial distribution of the magnetic flux perturbation is calculated with account of the externally applied RMP. A good agreement is obtained between the simulation results and experimental data for the cases of preprogrammed and feedback-controlled halo current in the plasma SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On modeling of integrated communication and control systems

The mathematical modeling scheme proposed by Ray and Halevi (1988) for integrated communication and control systems is considered analytically, with an emphasis on the effect of introducing varying and distributed time delays to account for asynchronous time-division multiplexing in the communication part of the system. Ray and Halevi applied a state-transition concept to transform the original continuous-time model into a discrete-time model; the same approach was used by Kalman and Bertram (1959) to model various types of sampled data systems which are not subject to induced delays. The relationship between the two modeling schemes is explored, and it is shown that, although the Kalman-Bertram method has the advantage of a unified approach, it becomes inconvenient when varying delays appear in the control loop.

Liou, Luen-Woei↗

Identification of aircraft stability and control derivatives in the presence of turbulence

A maximum likelihood estimator for a linear system with state and observation noise is developed to determine stability and control derivatives from flight data obtained in the presence of turbulence. The formulation for the longitudinal short-period mode is presented briefly, including a special case that greatly simplifies the problem if the measurement noise on one signal is negligible. The effectiveness and accuracy of the technique are assessed by applying it first to simulated flight data, in which the true parameter values and state noise are known, then to actual flight data obtained in turbulence. The results are compared with data obtained in smooth air and with wind-tunnel data. The complete maximum likelihood estimator, which accounts for both state and observation noise, is shown to give the most accurate estimate of the stability and control derivatives from flight data obtained in turbulence. It is superior to the techniques that ignores state noise and to the simplified method that neglects the measurement noise on the angle-of-attack signal.

Iliff, K. W.↗

Inspection Report "Personal Property Management at Lawrence Livermore National Laboratory"

The Department of Energy's (DOE's) Lawrence Livermore National Laboratory (Livermore) is a premier research and development institution for science and technology supporting the core mission of national security. According to Livermore, as of November 2008 the Laboratory managed 64,933 items of Government personal property valued at about $1 billion. At the beginning of Fiscal Year 2008, Livermore reported 249 DOE property items valued at about $1.3 million that were missing, unaccounted for, or stolen during Fiscal Year 2007. Livermore centrally tracks property utilizing the Sunflower Assets system (Sunflower), which reflects the cradle to grave history of each property item. Changes in the custodianship and/or location of a property item must be timely reported by the custodian to the respective property center representative for updating in Sunflower. In Fiscal Year 2008, over 2,000 individuals were terminated as a result of workforce reduction at Livermore, of which about 750 received a final notification of termination on the same day that they were required to depart the facility. All of these terminations potentially necessitated updates to the property database, but the involuntary terminations had the potential to pose particular challenges because of the immediacy of individuals departures. The objective of our inspection was to evaluate the adequacy of Livermore's internal controls over Government property. Based upon the results of our preliminary field work, we particularly focused on personal property assigned to terminated individuals and stolen laptop computers. We concluded that Livermore's internal controls over property could be improved, which could help to reduce the number of missing, unaccounted for, or stolen property items. Specifically, we found that: (1) The location and/or custodian of approximately 18 percent of the property items in our sample, which was drawn from the property assigned to individuals terminated on short notice in 2008, was inaccurately reflected in Sunflower. The data in this system is relied upon for tracking purposes, so inaccurate entries could increase the probability of property not being located during inventories and, thus, being reported as 'lost' or 'missing'. We believe that providing formal training to property custodians, which was not being done at the time of our inspection, could help improve this situation. (2) Some property custodians were not adequately protecting their Government laptop computers when taking them offsite, and they were not held accountable for the subsequent theft of the laptops. We made several recommendations to management intended to improve property controls at Livermore.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Bench-Scale Electrochemical System for Generation of CO and Syn-Gas

A bench-scale system for the electrochemical reduction of CO2 has been developed which produces CO and H2 (syn-gas) mixtures. The system is equipped with a gas-diffusion electrode which partially alleviates some of the mass-transport issues associated with CO2 delivery to the cathode. The positive effect of temperature was discovered where at 70°C a reduction in cell voltage of 1.57 V (compared to ambient) was observed at 70 mA cm-2. Controlling the flow of CO2 made it possible to maintain set H2:CO ratios with CO accounting for 25-90% of the product and H2 accounting for 10-75%. The cell, after an initial stabilization period of 40 min, displays reproducible, stable behavior. The current cell design brings the current densities for CO2 reduction closer to what is currently achieved in industrial alkaline electrolysis cells. This report discusses the electrolyte, electrode materials and variables which have been found to be significant in the production of CO and syn-gas mixtures.

08 HYDROGEN↗

Ultralow Thermal Conductivity and High-Temperature Thermoelectric Performance in n-Type K 2.5 Bi 8.5 Se 14

We studied the narrow band-gap (0.55 eV) semiconductor K 2.5 Bi 8.5 Se 14 as a potential thermoelectric material for power generation. Samples of polycrystalline K 2.5 Bi 8.5 Se 14 prepared by spark plasma sintering exhibit exceptionally low lattice thermal conductivities (κ lat ) of 0.57-0.33 W m -1 K -1 in the temperature range of 300-873 K. The physical origin of such low κ lat in K 2.5 Bi 8.5 Se 14 is related to the strong anharmonicity and low phonon velocity caused by its complex low symmetry, large unit cell crystal structure, and mixed occupancy of Bi and K atoms in the lattice. High-resolution scanning transmission electron microscopy studies and microanalysis indicate that the K 2.5 Bi 8.5 Se 14 sample is a single phase without intergrowth of the structurally related K 2 Bi 8 Se 13 phase. The undoped material exhibits an n-type character and a figure-of-merit (ZT) value of 0.67 at 873 K. Electronic band structure calculations indicate that K 2.5 Bi 8.5 Se 14 is an indirect band-gap semiconductor with multiple conduction bands close to the Fermi level. Phonon dispersion calculations suggest that K 2.5 Bi 8.5 Se 14 has low phonon velocities and large Grüneisen parameters that can account for the observed ultralow κ lat . The degree of n-type doping can be controlled by introducing Se deficiencies in the structure, providing a simple route to increase the ZT to ~1 at 873 K.

36 MATERIALS SCIENCE↗

The origin of oxygen in oxide thin films: Role of the substrate

During the growth of oxide thin films by pulsed laser deposition, a strong oxygen substrate-to-film transfer has been experimentally observed for SrTiO{sub 3} and LaAlO{sub 3} thin films epitaxially grown on {sup 18}O exchanged SrTiO{sub 3} and LaAlO{sub 3} substrates by secondary ion mass spectrometry depth profiling. This oxygen transfer effect can seriously change the respective thin film properties. Taking the oxygen substrate contribution to the overall oxygen balance into account, original ways to design material properties of oxide thin films can be envisioned like a controlled charge carrier doping of SrTiO{sub 3} thin films.

36 MATERIALS SCIENCE↗

Effect of polarization field on mean free path of phonons in indium nitride

The effect of built-in-polarization field on mean free path of acoustic phonons in bulk wurtzite indium nitride (InN) has been theoretically investigated. The elastic constant of the material gets modified due to the existence of polarization field. As a result velocity and Debye frequency of phonons get enhanced. The various scattering rates of phonons are suppressed by the effect of polarization field, which implies an enhanced combined relaxation time. Thus phonons travel freely for a longer distance between two successive scatterings. This would enhance the thermal transport properties of the material when built-in-polarization field taken into account. Hence by the application of electric field the transport properties of such materials can be controlled as and when desired.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First-principles calculations reveal controlling principles for carrier mobilities in semiconductors

It has long been believed that carrier mobilities in semiconductors can be calculated by Fermi s golden rule (Born approximation). Phenomenological models for scattering amplitudes are typically used for engineering- level device modeling. Here we introduce a parameter-free, first-principles approach based on complex- wavevector energy bands that does not invoke the Born approximation. We show that phonon-limited mobility is controlled by low-resistivity percolation paths and that in ionized-impurity scattering one must account for the effect of the screening charge, which cancels most of the Coulomb tail.Finally, calculated electron mobilities in silicon are in agreement with experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extended families of critical and stationary droplets for nonequilibrium phase transitions in spatially discrete bistable systems

Bistable nonequilibrium systems are realized in catalytic reaction-diffusion processes, biological transport and regulation, spatial epidemics, etc. Behavior in spatially continuous formulations, described at the mean-field level by reaction-diffusion type equations (RDEs), often mimics that of classic equilibrium van der Waals type systems. When accounting for noise, similarities include a discontinuous phase transition at some value, p eq , of a control parameter, p , with metastability and hysteresis around p eq . For each p , there is a unique critical droplet of the more stable phase embedded in the less stable or metastable phase which is stationary (neither shrinking nor growing), and with size diverging as p → p eq . Spatially discrete analogs of these mean-field formulations, described by lattice differential equations (LDEs), are more appropriate for some applications, but have received less attention. It is recognized that LDEs can exhibit richer behavior than RDEs, specifically propagation failure for planar interphases separating distinct phases. Herein, we show that this feature, together with an orientation dependence of planar interface propagation also deriving from spatial discreteness, results in the occurrence of entire families of stationary droplets. The extent of these families increases approaching the transition and can be infinite if propagation failure is realized. In addition, there can exist a regime of generic two-phase coexistence where arbitrarily large droplets of either phase always shrink. Such rich behavior is qualitatively distinct from that for classic nucleation in equilibrium and spatially continuous nonequilibrium systems.

97 MATHEMATICS AND COMPUTING↗

Six Machine-Learning Methods for Predicting Hospital-Stay Duration for Patients with Sepsis: A Comparative Study

Sepsis is a life-threatening medical condition that, if not treated promptly, can result in tissue damage, organ failure, and death. According to the Centers for Disease Control, about 270,000 individuals die of sepsis in the US each year. Further, sepsis expenditures accounted for 13% of total US hospital costs in 2013, totaling more than $24 billion. Our project objectives were to determine if Machine Learning algorithms could reliably predict hospital stay duration for patients with sepsis. The data set we used has been de-identified and is freely available through the BupaR package. The data includes 1050 cases, 15214 events, and 16 types of actions related to sepsis patient care. First, we used process mining to determine how long each patient was in the hospital. Using BupaR’s functions, we created several process model graphs. These process models depict the movement of patients at a hospital and provide duration data for each patent case. Second, we identified outlier data and created two dataset versions: one with and one without outliers. We then applied the following analysis methods: Linear Regression, Random Forest, K-Nearest Neighbors, Neural Networks, XGBoost, and lightGBM. We compared the model validations for the six machine learning models using the same data-splitting method. We found that the XGBoost model had the best prediction accuracy of 73.9 percent for cases with outliers, and 79 percent for cases without outliers. We also found that the lightGBM model had the lowest mean absolute error between prediction and actual duration in days with 3.66 days for the case with outliers, and 2.4 days for the case without outliers. These two models outperformed the other four models. This work will be enhanced in the future by exploring new prediction algorithms and comparing them with the results of this study.

Chen, Lingtao↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗

Understanding the Critical Parameters of the PAMS Mandrel Fabrication Process

As a part of an effort to continually better the roundness and roughness of ablator capsules, we looked at improving the same for the poly(alphamethylstyrene) or PAMS mandrels used to make the plastic capsules. The importance of this work is based on the fact that the surface properties of the mandrels set the lower limit for the ultimate attributes of the ablator capsule. These mandrels are made using an elegant double-emulsion process that uses the isotropic forces brought about by hydrostatic pressure and interfacial tension to seek sphericity. This paper describes the reasoning that led to investigating the so-called curing process where a solid PAMS shell is generated from a solution phase for achieving this goal. Using modeling to account for the mass transfer of the fluorobenzene solvent phase, we demonstrate that it is the control of the conditions through the percolation point of the system that leads to better mandrels. These concepts were implemented into the fabrication process to demonstrate significant improvements of the roundness of the mandrels.

36 MATERIALS SCIENCE↗

Estimating the Contributions to Human Error Probability from the Convolution of the Distribution of Time Available and Time Required

As part of their duties, Human Reliability Analysis must often evaluate if crews in nuclear power plants (NPPs) can complete tasks associated with a human-failure event within time limits. For example, the time required in NPP scenarios is determined by systematic and structured walkthroughs, feasibility studies, recorded times from training exercises, and interviews with experienced operators and experts. Typically, a point estimate is derived for the estimate (mean, maximum, or 95th percentile of time required). Using point-estimate values can mask the risk associated with variability among crews, plant conditions and set-up, environmental conditions, and other impact factors under which these actions are executed. While point estimates for time required and time available have served the industry well, without considering the uncertainty they could lead to biased understanding about the risk. The Integrated Human Event Analysis System - General Methodology (IDHEAS-G) model (developed by the US Nuclear Regulatory Commission, NRC) for human error probability calculates human error probability by summing two probabilities: insufficient time and cognitive error. As such, the model takes a more holistic approach by considering the full distributions for time required and time available to calculate the human error probability because the time available to complete the task is insufficient. In this study, we expand on the work of the NRC and discuss methods for estimating these time considerations. For example, for the time required, the impact of Performance Influencing Factors (PIFs) on the distribution was divided into impacts that are aleatory in nature, such as crew-to-crew variability, and those that are epistemic (i.e., the PIFs). Starting with the factors that introduce aleatory uncertainty, a first-order distribution was developed from a large set of time required (i.e., NPP task completion times) data for the range of operator actions that occur in the NPP control room under simulated accident conditions. The first-order distribution can then be adjusted to account for epistemic uncertainty using research associated with the impact of applicable PIFs on the time required. We also develop guidance for analysts to address the probability distributions for the time available. The guidance we developed on how to estimate time required and time available distributions is based on the identification of pertinent research and data, data analyses, and expert knowledge elicitation.

human error probability, human performance, time e↗

Variation in carbon and nitrogen concentrations among peatland categories at the global scale

Peatlands account for 15 to 30% of the world’s soil carbon (C) stock and are important controls over global nitrogen (N) cycles. However, C and N concentrations are known to vary among peatlands contributing to the uncertainty of global C inventories, but there are few global studies that relate peatland classification to peat chemistry. We analyzed 436 peat cores sampled in 24 countries across six continents and measured C, N, and organic matter (OM) content at three depths down to 70 cm. Sites were distinguished between northern (387) and tropical (49) peatlands and assigned to one of six distinct broadly recognized peatland categories that vary primarily along a pH gradient. Peat C and N concentrations, OM content, and C:N ratios differed significantly among peatland categories, but few differences in chemistry with depth were found within each category. Across all peatlands C and N concentrations in the 10–20 cm layer, were 440 ± 85.1 g kg -1 and 13.9 ± 7.4 g kg -1 , with an average C:N ratio of 30.1 ± 20.8. Among peatland categories, median C concentrations were highest in bogs, poor fens and tropical swamps (446–532 g kg -1 ) and lowest in intermediate and extremely rich fens (375–414 g kg -1 ). The C:OM ratio in peat was similar across most peatland categories, except in deeper samples from ombrotrophic tropical peat swamps that were higher than other peatlands categories. Peat N concentrations and C:N ratios varied approximately two-fold among peatland categories and N concentrations tended to be higher (and C:N lower) in intermediate fens compared with other peatland types. This study reports on a unique data set and demonstrates that differences in peat C and OM concentrations among broadly classified peatland categories are predictable, which can aid future studies that use land cover assessments to refine global peatland C and N stocks.

59 BASIC BIOLOGICAL SCIENCES↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of Energy Savings Potential from the Use of Demand Control Ventilation Systems in General Office Spaces in California

Demand controlled ventilation (DCV) was evaluated for general office spaces in California. A medium size office building meeting the prescriptive requirements of the 2008 California building energy efficiency standards (CEC 2008) was assumed in the building energy simulations performed with the EnergyPlus program to calculate the DCV energy savings potential in five typical California climates. Three design occupancy densities and two minimum ventilation rates were used as model inputs to cover a broader range of design variations. The assumed values of minimum ventilation rates in offices without DCV, based on two different measurement methods, were 81 and 28 cfm per occupant. These rates are based on the co-author's unpublished analyses of data from EPA's survey of 100 U.S. office buildings. These minimum ventilation rates exceed the 15 to 20 cfm per person required in most ventilation standards for offices. The cost effectiveness of applying DCV in general office spaces was estimated via a life cycle cost analyses that considered system costs and energy cost reductions. The results of the energy modeling indicate that the energy savings potential of DCV is largest in the desert area of California (climate zone 14), followed by Mountains (climate zone 16), Central Valley (climate zone 12), North Coast (climate zone 3), and South Coast (climate zone 6). The results of the life cycle cost analysis show DCV is cost effective for office spaces if the typical minimum ventilation rates without DCV is 81 cfm per person, except at the low design occupancy of 10 people per 1000 ft{sup 2} in climate zones 3 and 6. At the low design occupancy of 10 people per 1000 ft{sup 2}, the greatest DCV life cycle cost savings is a net present value (NPV) of $0.52/ft{sup 2} in climate zone 14, followed by $0.32/ft{sup 2} in climate zone 16 and $0.19/ft{sup 2} in climate zone 12. At the medium design occupancy of 15 people per 1000 ft{sup 2}, the DCV savings are higher with a NPV $0.93/ft{sup 2} in climate zone 14, followed by $0.55/ft{sup 2} in climate zone 16, $0.46/ft{sup 2} in climate zone 12, $0.30/ft{sup 2} in climate zone 3, $0.16/ft{sup 2} in climate zone 3. At the high design occupancy of 20 people per 1000 ft{sup 2}, the DCV savings are even higher with a NPV $1.37/ft{sup 2} in climate zone 14, followed by $0.86/ft{sup 2} in climate zone 16, $0.84/ft{sup 2} in climate zone 3, $0.82/ft{sup 2} in climate zone 12, and $0.65/ft{sup 2} in climate zone 6. DCV was not found to be cost effective if the typical minimum ventilation rate without DCV is 28 cfm per occupant, except at high design occupancy of 20 people per 1000 ft{sup 2} in climate zones 14 and 16. Until the large uncertainties about the base case ventilation rates in offices without DCV are reduced, the case for requiring DCV in general office spaces will be a weak case.