Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Condition Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Welch Method and Bootstrapping Applied to Subcritical Gamma Noise

We measured the prompt neutron decay constant 𝛼 of the CROCUS zero-power reactor at the Swiss Federal Institute of Technology Lausanne using cross-power spectral density (CPSD) analysis of gamma-gamma correlations from two trans-stilbene organic scintillators positioned near the reactor core. We measured critical and subcritical states, with water levels ranging from 960 mm (critical) to 800 mm (𝜌=−1.4 $ subcritical). Our analysis used the Welch method, dividing signal segments for fast Fourier transform (FFT) frequency analysis and applying bootstrapping uncertainty quantification that uses Welch-defined segments. Results demonstrated a clear increase in the measured 𝛼 as reactor reactivity decreased, distinguishing critical from subcritical conditions. At the 960-mm critical level, 𝛼 was estimated at 155.9 ± 0.7 s −1 , and for the 800-mm subcritical level, 𝛼 increased significantly to 367.3 ± 6.9 s –1 . A linear regression of subcritical states yielded a critical estimate of 154.0 ± 3.1 s –1 , aligning with the static 𝛼 estimate at critical. The bootstrapping method produced normally distributed 𝛼 estimates, confirming data consistency. The gamma CPSD 𝛼 estimates clearly distinguish reactor states and improve monitoring of zero-power reactors. The future deployment of modular and microreactors as potential candidates for noise analysis is demonstrated in CROCUS, particularly zero-power mock-ups of new designs. The improvement of noise analysis in the subcritical domain from this work will support experimental data for reactor deployment and procedure.

CROCUS↗

Numerical Simulation of Biogenic Fluid Catalytic Cracking (BFCC) Regenerators at Different Scales with MFIX-Exa

Catalytic Fast Pyrolysis (CFP) is a process that converts biomass into liquid intermediates suitable for transportation fuels by rapidly heating it in the presence of a catalyst, aiming to produce stable oils with reduced oxygen content. During CFP, the catalyst can become deactivated by the accumulation of coke, a carbon-rich deposit formed from the decomposition of biomass components. Unlike in petroleum refining, regenerating coked catalysts from biomass pyrolysis requires specific approaches due to the different chemical nature of the coke formed. An experimental technique, Temperature Programmed Oxidation (TPO), was used to study the de-coking process by gradually increasing temperature while monitoring the production of CO and CO2, which provides data for kinetic modeling. Utilizing data from TPO experiments, coke combustion kinetic model was developed to describe the rate of coke removal at different temperatures, allowing for simulation of regeneration processes. Then kinetic model is integrated into MFIX-Exa for the simulation of Biogenic Fluid Catalytic Cracker (BFCC) regenerator at different scales, enabling analysis of catalyst flow, temperature distribution, and regeneration efficiency under various operating conditions.

biogenic fluid catalytic cracking↗

Demonstration of the surveillance test article for an advanced reactor surveillance test program

Operational environments in generation IV reactors involve corrosive and irradiative conditions at elevated temperatures. Typical reactor operations consist of transients which impose cyclic loads on reactor components. These cyclic loads, combined with corrosive and irradiative environments, result in synergistic degradation of component materials. However, limited data exists on the coupled damage effects on materials for reactor environments. While the surrogate material surveillance concept has been used in light water reactors to assess irradiation damage, existing material surveillance technologies are not suitable for in-situ monitoring of coupled material degradation. The materials surveillance program focuses on material degradation management and the estimation of remaining life of reactor components through surveillance test articles. This paper presents the design and analysis methodology of a bi-metal surveillance test article, which uses difference in thermal expansion coefficient between two metals to induce in-situ cyclic loads. This report presents the work conducted in FY 25, to test the surveillance test article in air and salt environments. These test specimens were evaluated after thermal cycle exposure and remaining life is measured through creep test.

36 - MATERIALS SCIENCE↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

"Designing, simulating, and performing the 100-AV field test for the CIRCLES consortium: Methodology and Implementation of the Largest mobile traffic control experiment to date"

Previous controlled experiments on single-lane ring roads have shown that a single partially autonomous vehicle (AV) can effectively mitigate traffic waves. This naturally prompts the question of how these findings can be generalized to field operational, high-density traffic conditions. To address this question, the Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing (CIRCLES) Consortium conducted MegaVanderTest (MVT), a live traffic control experiment involving 100 vehicles near Nashville, TN, USA. This article is a tutorial for developing analytical and simulation-based tools essential for designing and executing a live traffic control experiment like the MVT. It presents an overview of the proposed roadmap and various procedures used in designing, monitoring, and conducting the MVT, which is the largest mobile traffic control experiment at the time. The design process is aimed at evaluating the impact of the CIRCLES AVs on surrounding traffic. The article discusses the agent-based traffic simulation framework created for this evaluation. A novel methodological framework is introduced to calibrate this microsimulation, aiming to accurately capture traffic dynamics and assess the impact of adding 100 vehicles to existing traffic. The calibration model's effectiveness is verified using data from a six-mile section of Nashville's I-24 highway. The results indicate that the proposed model establishes an effective feedback loop between the optimizer and the simulator, thereby calibrating flow and speed with different spatiotemporal characteristics to minimize the error between simulated and real-world data. Finally, We simulate AVs in multiple scenarios to assess their effect on traffic congestion. This evaluation validates the AV routes, thereby contributing to the execution of a safe and successful live traffic control experiment via AVs.

Ameli, Mostafa↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Annual Status Report (FY 2020): Performance Assessment for the Environmental Restoration Disposal Facility

DOE O 435.1 and DOE M 435.1-1 require that a determination of continued adequacy of the performance assessment (PA) (CP-60089), composite analysis, and disposal authorization statement (DAS) be made annually, and these guidelines must be used to consider the results of data collection and analysis from research, field studies, and monitoring as well as provide the need to update any radioactive waste management basis documents. Beginning in 1996, the Environmental Restoration Disposal Facility (ERDF) started accepting low-level radioactive, hazardous, and mixed wastes generated during cleanup activities at the Hanford Site. ERDF is composed of a series of cells or disposal areas and can accommodate future design expansions as needed. Currently, there are 10 cells. During this reporting period (fiscal year 2020, which extended from October 1, 2019, through September 30, 2020), approximately 3.39E+04 U.S. tons (3.07E+04 metric tons) of waste was disposed at ERDF. From ERDF inception through September 30, 2020, approximately 18.5 million U.S. tons of waste has been disposed at ERDF, which equates to the consumption of approximately 88% of the disposal volume. As a condition of the DAS, disposal operations within ERDF must be in accordance with the waste acceptance criteria (ERDF-00011) that provide specific radionuclide disposal limits, waste form restrictions, and descriptions of acceptable waste packages in compliance with DOE M 435.1-1 requirements. The ERDF waste acceptance criteria stipulate that waste destined for disposal at ERDF be controlled based on source, physical form, and contaminant concentration and activity levels. There have been no changes to the physical configuration of ERDF or to the waste forms (source, physical form, etc.). No new Unreviewed Disposal Question Screenings or Evaluations have been generated during this reporting period. Therefore, there are no noted impacts to the PA, composite analysis, DAS, or radioactive waste management basis documents resulting from the evaluations and screenings. Sum of fraction analysis shows that the disposed inventory meets both the concentration and inventory threshold requirements. A sum of fractions value is computed for ERDF sensitive radionuclides contributing to the all pathways and air pathway inventory limits. Computed values were 8.85E-02 and 1.78E-01, respectively. The disposed waste inventory remained well under the PA imposed limits. Required monitoring was satisfactorily completed during the fiscal year reporting period (fiscal year 2020). Compliance with performance objectives were met as each of the reported values were well below the established limit. Overall, there are no substantive changes to primary PA assumptions nor changes to the PA analysis conclusion; therefore, compliance with DOE O 435.1 and the DAS is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Kilometer-Scale Hydrologic Exchange Flows in a Gravel Bed River Corridor and Their Implications to Solute Migration

In this work, a well-characterized field site along a major river corridor was used to investigate the dynamic pathways and impacts of subsurface hydrogeologic structures on kilometer-scale hydrologic exchange flows between river water and groundwater. A aqueous uranium (U aq ) plume exists at the site that discharges to the Columbia River. We performed temporally intensive monitoring of specific conductance (SpC) and U aq concentrations within the plume at increasing distances from the river shoreline and at locations both within and outside a presumed subsurface pathway of lateral hydrologic exchange. Specific conductance and U aq were utilized as in-situ tracers of hydrologic exchange and associated groundwater-surface water mixing. Monitoring data was collected for an approximate two year period during which seasonal river elevations varied by more than 2 m causing distinct events of river water intrusion and retreat from the near-shore aquifer, and large temporal variations in well-water analyte concentrations. Statistical clustering analysis was applied to identify well groupings exhibiting common time series behaviors. PFLOTRAN was implemented within a modeling domain of 3.3 x 1.9 km with dynamic flow boundary conditions and accurate subsurface topography for the basal aquitard underlying the aquifer. In-silico calculations of river water tracer behavior were performed to assess predominant flow directions and velocities influenced by river stage variations and variable aquitard topography, and their collective influences on SpC and U aq concentrations. We demonstrate complicated multidirectional flow behaviors at the kilometer scale resulting from hydrologic exchange and subsurface structure that influence plume dynamics and determine the overall system behavior.

54 ENVIRONMENTAL SCIENCES↗

Capturing in-field root system dynamics with RootTracker

Abstract Optimizing root system architecture offers a promising approach to developing stress tolerant cultivars in the face of climate change, as root systems are critical for water and nutrient uptake as well as mechanical stability. However, breeding for optimal root system architecture has been hindered by the difficulty in measuring root growth in the field. Here, we describe the RootTracker, a technology that employs impedance touch sensors to monitor in-field root growth over time. Configured in a cylindrical, window shutter-like fashion around a planted seed, 264 electrodes are individually charged multiple times over the course of an experiment. Signature changes in the measured capacitance and resistance readings indicate when a root has touched or grown close to an electrode. Using the RootTracker, we have measured root system dynamics of commercial maize (Zea mays) hybrids growing in both typical Midwest field conditions and under different irrigation regimes. We observed rapid responses of root growth to water deficits and found evidence for a “priming response” in which an early water deficit causes more and deeper roots to grow at later time periods. Genotypic variation among hybrid maize lines in their root growth in response to drought indicated a potential to breed for root systems adapted for different environments. Thus, the RootTracker is able to capture changes in root growth over time in response to environmental perturbations.

Aguilar, Jeffrey J.↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EPCAPE-Dalhousie Field Campaign Report

This project supported the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), which aimed to characterize the extent, radiative properties, aerosol interactions, and precipitation of stratocumulus clouds in the Eastern Pacific coastal region of La Jolla, California. Given the frequent anthropogenic aerosols emitted into this region, characterization of this important coastal cloud region and the aerosol impact on the cloud characteristics will improve the understanding of aerosol indirect effects and its representation in global climate models. This specific project deployed the fog droplet monitor (FM-120, Droplet Measurement Technologies) at the Scripps Institution of Oceanography’s Mt. Soledad site from 16 February 2023 to 15 February 2024. This instrument measured droplet number size spectra between 2 and 50 microns, from which droplet number concentration, liquid water content, and effective diameter were calculated. These measurements will be used to characterize the seasonal variability of clouds at Mt. Soledad and investigate differences in cloud properties under regional polluted and clean marine conditions. The collected data will soon be posted as part of the digital collection for EPCAPE data hosted by the University of California, San Diego (Russell et al. 2023).

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation of Elastodynamic Nonlinear Response of Dry Intact, Fractured and Saturated Rock

Nonlinear elastodynamic response of fractured rocks carries crucial information on fracture features that can be exploited to forecast flow properties, friction constitutive behavior and poromechanical response. Well-controlled laboratory experiments are designed to measure the nonlinear elastodynamic response of Westerly granite in three states: dry intact, dry fractured and saturated fractured. We study the effect of fracturing and saturation in modifying the elastodynamic response of the rock. Each sample is tested at a normal stress level of 15 MPa. We measure the elastodynamic response of an intact L-shaped sample of Westerly Granite subjected to normal stress oscillations of prescribed amplitudes (0.2–1 MPa) and frequencies (0.1, 1, 10 Hz). Ultrasonic waves transmitted across the sample are used to monitor the evolution of wave velocity before, during and after dynamic stressing. Furthermore, the nonlinearity of the elastodynamic response is measured in terms of: (1) the offset in normalized wave velocity; (2) the amplitude of wave velocity fluctuation during the oscillations; and (3) recovery rate of the wave velocity post-oscillation. We observe that the three nonlinearity parameters show a similar trend. Irrespective of the parameter, the nonlinearity measures higher for sample in dry-intact condition than that for dry-fractured and the saturated-fractured sample exhibits smaller nonlinearity than the dry-fractured sample. As expected, the saturated sample exhibits less nonlinearity than the dry intact and fractured samples due to the presence of interstitial fluid and the resulting increased interface stiffness. Conversely, the dry intact rock shows a higher nonlinearity than the dry fractured. We use numerical simulations to show that the presence of fracture significantly alters the strain distribution across the bulk of the sample and only the contacting asperities are highly strained, thus resulting in a decrease in the measured elastodynamic nonlinearity.

58 GEOSCIENCES↗

Transfer learning for probabilistic localization of hidden cracks in concrete structures

Abstract The utility of discriminative supervised learning models built using multiple training-data sources is investigated for hidden crack localization in concrete. Feed-forward neural network (FFNN) is chosen as the model architecture, and transfer learning is used to assimilate the information obtained from different sources (computational physics simulations and laboratory experiments). The labeled training data consists of values of a damage index and the known locations of hidden cracks. The classification models need to learn how the presence of damage (hidden cracks) affects the damage index at different sensors for different test conditions. To this end, diagnostic FFNN models are built by sequentially adding and training new hidden layers to assimilate labeled information from computer models (different model geometries, test conditions, crack lengths, crack locations) and laboratory experiments on a plain cement slab. These transfer learning-based models are then used to localize damage in concrete specimens that reflect real-world conditions (i.e., specimens with steel reinforcement and randomly distributed aggregate). The actual damage state in these specimens is determined by extracting cores and performing petrographic studies on the extracted cores. The damage probability estimated by transfer learning-based models is compared with the petrographic damage rating index (DRI) to identify the most suitable approach to train the diagnostic models. The transfer learning-based diagnostic methodology shows promise and could be used in various structural health monitoring applications, where sufficient labeled data are typically not available from a single data source.

Miele, S.↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗