Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONFIGURATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Magnetic Reconnection on Dayside Crustal Magnetic Fields at Mars: MAVEN Observations

The identification of magnetic reconnection on the dayside of Mars has been elusive owing to the lack of comprehensive plasma and field measurements. Here we present direct measurements of dayside in situ reconnection signatures by the comprehensive particles and fields package on board the Mars Atmosphere and Volatile EvolutioN (MAVEN) spacecraft over strong crustal magnetic fields in the southern hemisphere of Mars. During a crossing of a bifurcated current sheet consisting of northward and southward magnetic fields, MAVEN recorded (i) ionospheric photoelectrons trapped on closed magneticfield lines, (ii) Hall magnetic fields and a nonzero normal field with polarity consistent with a crossing northward of the X line, and (iii) northward Alfvenic ion jets. Dayside magnetic reconnection on crustal magnetic fields could control the global configuration and topology of the Martian magnetosphere and alter the ion escape pattern from the dayside ionosphere.

Magnetic↗

GN&C Sequencing for Orion Rendezvous, Proximity Operations, and Docking

As part of the Artemis program to return humans to the lunar surface, the National Aeronautics and Space Administration is planning to use the Orion Multi- Purpose Crew Vehicle to transport crew to a small orbital platform called Gate- way in cislunar space. To facilitate this activity, Orion is required to perform Rendezvous, Proximity Operations, and Docking (RPOD) with both the Gate- way and the launch vehicle upper stage. The Orion spacecraft uses sequencing in the form of Phases, Segments, Activities, and Modes (PSAM) to configure Guidance, Navigation, & Control (GN&C) software during each portion of the mission. Significant updates to Orion PSAM definitions are required for RPOD. This paper describes the process of defining these new sequencing elements, implementing them in prototype flight software, and testing them in an integrated simulation environment. First, requirements are specified to determine the nominal and off-nominal sequencing behavior necessary to complete the mission. These requirements also specify which software functions should be fully autonomous and which functions require manual interactions from crew or ground operators. Next, the RPOD concept of operations is defined with detailed events listed in a mission timeline. Third, a state machine diagram is developed to show all PSAM states, including all possible transitions between them. After this, the PSAM states and transitions are entered into a sequencing software emulator and parameter values and modes are defined for GN&C software elements. Finally, the PSAM architecture is tested within an integrated simulation environment by connecting it with prototypes of relevant GN&C flight software elements and with detailed vehicle models. After the sequencing design has been finalized and tested, it is implemented in flight software.

Schulte, Peter Z.↗

Systems and methods for deactivating a matrix converter

Systems and methods are provided for deactivating a matrix conversion module. An electrical system comprises an alternating current (AC) interface, a matrix conversion module coupled to the AC interface, an inductive element coupled between the AC interface and the matrix conversion module, and a control module. The control module is coupled to the matrix conversion module, and in response to a shutdown condition, the control module is configured to operate the matrix conversion module to deactivate the first conversion module when a magnitude of a current through the inductive element is less than a threshold value.

30 DIRECT ENERGY CONVERSION↗

Systems and methods for reducing transient voltage spikes in matrix converters

Systems and methods are provided for delivering energy using an energy conversion module that includes one or more switching elements. An exemplary electrical system comprises a DC interface, an AC interface, an isolation module, a first conversion module between the DC interface and the isolation module, and a second conversion module between the AC interface and the isolation module. A control module is configured to operate the first conversion module to provide an injection current to the second conversion module to reduce a magnitude of a current through a switching element of the second conversion module before opening the switching element.

30 DIRECT ENERGY CONVERSION↗

Coordinated garbage collection for raid array of solid state disks

An optimized redundant array of solid state devices may include an array of one or more optimized solid-state devices and a controller coupled to the solid-state devices for managing the solid-state devices. The controller may be configured to globally coordinate the garbage collection activities of each of said optimized solid-state devices, for instance, to minimize the degraded performance time and increase the optimal performance time of the entire array of devices.

97 MATHEMATICS AND COMPUTING↗

High-frequency matrix converter with square wave input

A device for producing an alternating current output voltage from a high-frequency, square-wave input voltage comprising, high-frequency, square-wave input a matrix converter and a control system. The matrix converter comprises a plurality of electrical switches. The high-frequency input and the matrix converter are electrically connected to each other. The control system is connected to each switch of the matrix converter. The control system is electrically connected to the input of the matrix converter. The control system is configured to operate each electrical switch of the matrix converter converting a high-frequency, square-wave input voltage across the first input port of the matrix converter and the second input port of the matrix converter to an alternating current output voltage at the output of the matrix converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ACCELEROMETERS IN FLOW FIELDS: A STRUCTURAL ANALYSIS OF THE CHOPPED DUMMY INPILE TUBE

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s2 in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electron spin-based information shuttling for a computer system

A silicon metal-oxide semiconductor device transports a spin-polarized single electron. An array of silicon quantum dot electrodes is arranged atop a silicon dioxide layer of a silicon metal-oxide semiconductor. The array comprises at least a first electrode and a second electrode adjacent to the first electrode. A transport control logic for individually controls a voltage applied to the electrodes. The transport control logic is configured to gradually decrease a voltage at the first electrode while gradually increasing a voltage at the second electrode. Localization of the single electron is adiabatically transferred from the first electrode to the second electrode while maintaining a desired energy gap between a ground state and a first excited state of the single electron.

Gamble, IV, John King↗

Flexible and Scalable Data-Acquisition Using the artdaq Toolkit

The Real-Time Systems Engineering Department of the Scientific Computing Division at Fermilab is developing a flexible, scalable, and powerful data-acquisition (DAQ) toolkit which serves the needs of experiments from bench-top hardware tests to large high-energy physics experiments. The toolkit provides data transport and event building capabilities with the option for experimenters to inject art analysis code at key points in the DAQ for filtering or monitoring. The toolkit also provides configuration management, run control, and low-level hardware communication utilities. Firmware blocks for several commercial data acquisition boards are provided, allowing experimenters to approach the DAQ from a high level. A fully-functional DAQ "solution" of the toolkit is provided in otsdaq, sacrificing some flexibility in favor of being ready-to-use. artdaq is being used for several current and upcoming experiments, and will continue to be refined and expanded for use in the next generation of neutrino and muon experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Analysis of the nuclear measurement program for an optimized BR2 core configuration

This paper presents the analysis of the results of the Nuclear Measurement Program (NMP) executed during the shut-down of cycle 05/2012 of the BR2 reactor. The aim of the NMP was to determine the properties of a reactor core load with a new configuration of the control rods and to evaluate/verify the predicted numerical results by MCNPX. The methods used for the interpretation of the measurement results include combinations of an analytical method for determination of the axial relative control rod efficiency and least square techniques. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Systems and methods for online power management for hybrid powertrains

At least some embodiments of the present disclosure are directed to systems and methods of online power management for hybrid powertrains. In some embodiments, the hybrid powertrain control system is configured to conduct a brake-thermal-efficiency (BTE) estimation procedure when the powertrain is in operation by operating the hybrid powertrain at a plurality of speeds for a plurality of designated power levels and select certain BTE operating conditions to update the power management.

Gosala, Dheeraj B.↗

Systems and methods for satellite movement

A satellite includes a plurality of thrusters disposed about the satellite, each of the plurality of thrusters having a minimum thruster firing time, and a control circuit connected to the plurality of thrusters. The control circuit is configured to identify violations of the minimum thruster firing time in a non-compliant thruster firing pattern selected to achieve a specified movement, generate a plurality of compliant thruster firing patterns by replacing each of the violations of the non-compliant thruster firing pattern by zero and a minimum time in different combinations, select a compliant thruster firing pattern from the plurality of compliant thruster firing patterns to produce a satellite movement that is within a predetermined range of the specified movement, and cause the plurality of thrusters to fire according to the compliant thruster firing pattern.

Cheng, Haifei↗

Accelerometers in flow fields: a structural analysis of the chopped dummy in-pile tube

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s{sup 2} in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design. (authors)

42 ENGINEERING↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

Bus repeater and bit injector for MIL-STD-1553/1760 communications bus

A fault insertion device (FID) comprises a transceiver and an FPGA. The transceiver receives signals from a MIL-STD-1553/1760 communications bus. The FPGA evaluates the signals received from the communications bus against a set of rules stored by the FPGA. Based upon the set of rules, the FPGA can selectively modify messages received from the communications bus prior to transmission to a remote terminal or a bus controller that is configured to communicate on the communications bus.

Krein, Jason P.↗