Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BUSINESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Sandia National Laboratories, California Chemical Management Program Annual Report

The annual program report provides detailed information about all aspects of the Sandia National Laboratories, California (SNL/CA) Chemical Management Program. It functions as supporting documentation to the SNL/CA Environmental Management System Program Manual. This program annual report describes the activities undertaken during the calender past year, and activities planned in future years to implement the Chemical Management Program, one of six programs that supports environmental management at SNL/CA. SNL/CA is responsible for tracking chemicals (chemical and biological materials), providing Material Safety Data Sheets (MSDS) and for regulatory compliance reporting according to a variety of chemical regulations. The principal regulations for chemical tracking are the Emergency Planning Community Right-to-Know Act (EPCRA) and the California Right-to-Know regulations. The regulations, the Hazard Communication/Lab Standard of the Occupational Safety and Health Administration (OSHA) are also key to the CM Program. The CM Program is also responsible for supporting chemical safety and information requirements for a variety of Integrated Enabling Services (IMS) programs primarily the Industrial Hygiene, Waste Management, Fire Protection, Air Quality, Emergency Management, Environmental Monitoring and Pollution Prevention programs. The principal program tool is the Chemical Information System (CIS). The system contains two key elements: the MSDS library and the chemical container-tracking database that is readily accessible to all Members of the Sandia Workforce. The primary goal of the CM Program is to ensure safe and effective chemical management at Sandia/CA. This is done by efficiently collecting and managing chemical information for our customers who include Line, regulators, DOE and ES and H programs to ensure compliance with regulations and to streamline customer business processes that require chemical information.

54 ENVIRONMENTAL SCIENCES↗

Energy Implications of Retrofitting Retail Sector Rooftop Units With Stepped Speed and Variable-Speed Functionality

Commercial retailers understand that retrofitting constant-speed RTU fan motors with stepped- or variable-speed alternatives could save significant energy in most U.S. climate zones. However, they lack supporting data, both real-world and simulation based, on the cost effectiveness and climate zone-specific energy savings associated with this measure. Thus, building managers and engineers havebeen unable to present a compelling business case for fan motor upgrades to upper management. This study uses whole-building energy simulation to estimate the energy impact of this type of measure so retailers can determine its economic feasibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Navajo Hopi Land Commission Renewable Energy Development Project (NREP)

The Navajo Hopi Land Commission Office (NHLCO), a Navajo Nation executive branch agency has conducted activities to determine capacity-building, institution-building, outreach and management activities to initiate the development of large-scale renewable energy - 100 megawatt (MW) or larger - generating projects on land in Northwestern New Mexico in the first year of a multi-year program. The Navajo Hopi Land Commission Renewable Energy Development Project (NREP) is a one year program that will develop and market a strategic business plan; form multi-agency and public-private project partnerships; compile site-specific solar, wind and infrastructure data; and develop and use project communication and marketing tools to support outreach efforts targeting the public, vendors, investors and government audiences.

14 SOLAR ENERGY↗

Elk Valley Rancheria Energy Efficiency and Alternatives Analysis

The Elk Valley Rancheria, California ('Tribe') is a federally recognized Indian tribe located in Del Norte County, California, in the northwestern corner of California. The Tribe, its members and Tribal enterprises are challenged by increasing energy costs and undeveloped local energy resources. The Tribe currently lacks an energy program. The Tribal government lacked sufficient information to make informed decisions about potential renewable energy resources, energy alternatives and other energy management issues. To meet this challenge efficiently, the Tribe contracted with Frank Zaino and Associates, Inc. to help become more energy self-sufficient, by reducing their energy costs and promoting energy alternatives that stimulate economic development. Frank Zaino & Associates, Inc. provided a high level economic screening analysis based on anticipated electric and natural gas rates. This was in an effort to determine which alternative energy system will performed at a higher level so the Tribe could reduce their energy model by 30% from alternative fuel sources. The feasibility study will identify suitable energy alternatives and conservation methods that will benefit the Tribe and tribal community through important reductions in cost. The lessons learned from these conservation efforts will yield knowledge that will serve a wider goal of executing energy efficiency measures and practices in Tribal residences and business facilities. Pacific Power is the provider of electrical power to the four properties under review at $ 0.08 per Kilowatt-hour (KWH). This is a very low energy cost compared to alternative energy sources. The Tribe used baseline audits to assess current and historic energy usage at four Rancheria owned facilities. Past electric and gas billing statements were retained for review for the four buildings that will be audited. A comparative assessment of the various energy usages will determine the demand, forecast future need and identify the differences in energy costs, narrowing the focus of the work and defining its scope. The Tribe's peak demand periods will help determine the scope of need for alternative energy sources. The Tribe's Energy Efficiency and Alternatives Analysis report included several system investigations which include fuel cells, wind turbines, solar panels, hydro electric, ground source heat pumps, bio mass, cogeneration & energy conservation and implementation for the existing properties. The energy analysis included site visits to collect and analyze historical energy usage and cost. The analysis also included the study of the building systems for the Elk Valley Casino, Elk Valley Rancheria administration complex, United Indian Health Service/Small Community Center complex and the Tribal Gaming Commission Offices. The analysis involved identifying modifications, performing an engineering economic analysis, preparation of a rank ordered list of modifications and preparation of a report to provide recommendations and actions for the Tribe to implement.

03 NATURAL GAS↗

Recovery Act: A Measurement -- Management Technology for Improving Energy Efficiency in Data Centers and Telecommunication Facilities (Final Technical Report)

Data center (DC) electricity use is increasing at an annual rate of over 20% and presents a concern for the Information Technology (IT) industry, governments, and the society. A large fraction of the energy use is consumed by the compressor cooling to maintain the recommended operating conditions for IT equipment. The most common way to improve the DC efficiency is achieved by optimally provisioning the cooling power to match the global heat dissipation in the DC. However, at a more granular level, the large range of heat densities of today's IT equipment makes the task of provisioning cooling power optimized to the level of individual computer room air conditioning (CRAC) units much more challenging. Distributed sensing within a DC enables the development of new strategies to improve energy efficiency, such as hot spot elimination through targeted cooling, matching power consumption at rack level with workload schedule, and minimizing power losses. The scope of Measurement and Management Technologies (MMT) is to develop a software tool and the underlying sensing technology to provide critical decision support and control for DC and telecommunication facilities (TF) operations. A key aspect of MMT technology is integration of modeling tools to understand how changes in one operational parameter affect the overall DC response. It is demonstrated that reduced ordered models for DC can generate, in less than 2 seconds computational time, a three dimensional thermal model in a 50 kft 2 DC. This rapid modeling enables real time visualization of the DC conditions and enables "0what if" scenarios simulations to characterize response to "disturbances". One such example is thermal zone modeling that matches the cooling power to the heat generated at a local level by identifying DC zones cooled by a specific CRAC. Turning off a CRAC unit can be simulated to understand how the other CRAC utilization changes and how server temperature responds. Several new sensing technologies were added to the existing MMT platform: (1) air contamination (corrosion) sensors, (2) power monitoring, and (3) a wireless environmental sensing network. All three technologies are built on cost effective sensing solutions that increase the density of sensing points and enable high resolution mapping of DCs. The wireless sensing solution enables Air Conditioning Unit (ACU) control while the corrosion sensor enables air side economization and can quantify the risk of IT equipment failure due to air contamination. Validation data for six test sites demonstrate that leveraging MMT energy efficiency solutions combined with industry best practices results in an average of 20% reduction in cooling energy, without major infrastructure upgrades. As an illustration of the unique MMT capabilities, a data center infrastructure efficiency (DCIE) of 87% (industry best operation) was achieved. The technology is commercialized through IBM System and Technology Lab Services that offers MMT as a solution to improve DC energy efficiency. Estimation indicates that deploying MMT in existing DCs can results in an 8 billion kWh savings and projection indicates that constant adoption of MMT can results in obtainable savings of 44 billion kWh in 2035. Negotiations are under way with business partners to commercialize/license the ACU control technology and the new sensor solutions (corrosion and power sensing) to enable third party vendors and developers to leverage the energy efficiency solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Introduction to Risk with a Focus on Design Diversity in the Stockpile

The maintenance and security of nuclear weapons in the stockpile involves decisions based on risk analysis and quantitative measures of risk. Risk is a factor in all decisions, a particularly important factor in decisions of a large scale. One example of high-risk decisions we will discuss is the risk involved in design diversity within the stockpile of nuclear weapons arsenal. Risk is defined as 'possibility of loss or injury' and the 'degree of probability of such loss' (Kaplan and Garrick 12). To introduce the risk involved with maintaining the weapons stockpile we will draw a parallel to the design and maintenance of Southwest Airlines fleet of Boeing 737 planes. The clear benefits for cost savings in maintenance of having a uniform fleet are what historically drove Southwest to have only Boeing 737s in their fleet. Less money and resources are need for maintenance, training, and materials. Naturally, risk accompanies those benefits. A defect in a part of the plane indicates a potential defect in that same part in all the planes of the fleet. As a result, safety, business, and credibility are at risk. How much variety or diversity does the fleet need to mitigate that risk? With that question in mind, a balance is needed to accommodate the different risks and benefits of the situation. In a similar way, risk is analyzed for the design and maintenance of nuclear weapons in the stockpile. In conclusion, risk must be as low as possible when it comes to the nuclear weapons stockpile. Design and care to keep the stockpile healthy involves all aspects of risk management. Design diversity is a method that helps to mitigate risk, and to help balance options in stockpile stewardship.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

VCAT: Visual Crosswalk Analysis Tool [Slides]

VCAT is a knowledge modeling and analysis tool. It was synthesized from ideas in functional analysis, business process modeling, and complex network science. VCAT discovers synergies by analyzing natural language descriptions. Specifically, it creates visual analytic perspectives that capture intended organization structures, then overlays the serendipitous relationships that point to potential synergies within an organization or across multiple organizations.

97 MATHEMATICS AND COMPUTING↗

Small Buildings = Big Opportunity for Energy Savings [Fact Sheet]

This fact sheet describes the Small Buildings and Small Portfolios roadmap, which outlines approaches and strategic priorities for the U.S. Department of Energy's Building Technologies Office to pursue over the next three to five years that will support the implementation of high-potential energy efficiency opportunities for small business and building owners and operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Systems of the Future: A 21st Century Power Partnership Thought Leadership Report

This report summarizes key forces driving transformation in the power sector around the world, presents a framework for evaluating decisions regarding extent and pace of change, and defines pathways for transformation. Powerful trends in technology, policy environments, financing, and business models are driving change in power sectors globally. In light of these trends, the question is no longer whether power systems will be transformed, but rather how these transformations will occur. Three approaches to policy and technology decision-making can guide these transformations: adaptive, reconstructive, and evolutionary. Within these approaches, we explore the five pathways that have emerged as viable models for power system transformation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Meeting Summary of Kitchen Cabinet on Financial Due Diligence to Reduce Proliferation Risks

The U.S. Department of Energy’s Pacific Northwest National Laboratory convened the Kitchen Cabinet (KC) to facilitate a candid discussion about the role of financial institutions (FIs) in antiproliferation efforts to reduce nuclear proliferation risks by identifying suspicious business transactions and exports when making lending or insurance decisions. The meeting brought together a group of export control specialists, largely representatives from the Nuclear Suppliers Group (NSG) Participating Governments (PGs) and finance experts representing banks and insurance companies. By assembling a KC of experts, the group could understand what suspicious transactions look like from each other’s perspectives and better inform each of their operations. The goal was to develop red flags FIs could use to identify suspicious proliferation-related transactions and to help governments gain a clearer picture of proliferation using financial information.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Next-Generation Performance-Based Regulation. Volume 1: Introduction - Global Lessons for Success; Volume 2: Primer - Essential Elements of Design and Implementation; Volume 3: Innovative Examples from Around the World

Performance-based regulations (PBRs) provide a regulatory framework to connect goals, targets, and measures to utility performance or executive compensation. Well-designed PBRs provide incentives for utility performance, benefiting consumers and utility owners alike. This report considers the role of both PBRs and more discrete performance incentive mechanisms (PIMs) in 21st century power sector transformation. Innovative technologies are transforming the way electricity is generated, delivered, and consumed. PBRs have the potential to realign utility, investor, and consumer incentives and mitigate emerging challenges to the utility business model, renewable integration, and even cyber security.The goals of PBRs in the form of multi-year rate plans are in many respects the same in terms of providing reasonably priced and reliable service to customers. However, today's technologies have changed, and there is more emphasis on clean energy. Thus, the pathways and the potential outcomes are different than they were in the 20th century when centralized generator stations and large infrastructure additions dominated the utility landscape. Given unprecedented changes underway in the electricity sector, PBRs - by specifying expectations of utility performance and outcomes for consumers, while staying agnostic to the exact means of delivery - constitute a form of prescient regulation that harnesses disruption. PBRs are one tool in a broader toolbox in the transition toward flexible regulatory and market structures that rewards utilities that adapt or evolve in reaction to market and technology change. PBRs and PIMs have great value for the electric industry when designed well and can be applied to many different situations. How exactly PBR mechanisms are most effectively enacted will vary based on the utility ownership model, institutional arrangements, and a variety of other local factors. PBRs should be tailored to the needs and goals of each jurisdiction, and perhaps each utility, to most effectively achieve the needs of a 21st century power grid in that jurisdiction. Presented in three volumes, this report highlights the lessons learned from their evolving history, explores essential elements of their design and implementation as well as considerations for how they may be best applied, and examines leading examples of PBRs from the United Kingdom, New York, Denmark, Mexico, and South Africa. The full report, 'Next-Generation Performance Based Regulation - Emphasizing Utility Performance to Unleash Power Sector Innovation,' published in September 2017, can be accessed at https://www.nrel.gov/docs/fy17osti/68512.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Small Wind Electric Systems: A Guide Produced for the Tennessee Valley Authority (Revised) (Brochure)

Small Wind Electric Systems: A Guide Produced for the Tennessee Valley Authority provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and their economics. Topics discussed in the guide include how to make a home more energy efficient, how to choose the correct turbine size, the parts of a wind electric system, how to determine whether enough wind resource exists, how to choose the best site for a turbine, how to connect a system to the utility grid, and whether it's possible to become independent of the utility grid using wind energy. In addition, the cover of the guide contains a regional wind resource map and a list of incentives and contacts for more information.

17 WIND ENERGY↗

Optimizing an Integrated Renewable-Electrolysis System

Hydrogen is a versatile energy carrier that is used in a wide variety of chemical and industrial processes. Producing hydrogen using electrolysis can enable integration of multiple sectors including electricity, heating, and industrial sectors; however, the cost of producing hydrogen from electrolysis remains a challenge for encouraging greater adoption. With growing amounts of renewable generation on the California grid, there is downward pressure on wholesale electricity prices, particularly during the afternoon from photovoltaics (PV). These lower, or even potentially negative prices, challenge the business cases for new and existing PV plants. In addition, as the grid transitions to less flexible generation, there is greater need for system flexibility. To help improve the economics for both solar PV and hydrogen production using electrolyzers, we explore the benefit of combining PV and electrolysis systems. The optimal breakeven hydrogen production cost for six unique market participation configurations is calculated at six candidate locations where PV is already installed. The six market configurations include islanded, separated, retail, net energy metering (NEM), hybrid retail/wholesale and wholesale. Using the Revenue Operation and Device Optimization Model (RODeO) model, the optimal breakeven hydrogen price over the lifetime of the equipment is calculated. The cost includes production, storage, and compression in preparation for gaseous delivery trucks. Revenue streams include the sale of hydrogen, low carbon fuel standard (LCFS) credits, renewable electricity sold to the grid, and Renewable Energy Credits (REC). The costs included are the electricity costs, capital and fixed operation and maintenance cost (FOM) for the electrolyzer, PV, and storage and compression systems as well as taxes and financing costs. In addition, cost reductions are achieved through retail and wholesale rate optimization, by which electricity is purchased at the lowest price and sold, if possible, at the highest price. For all locations, the breakeven hydrogen production cost results show that, in the order of decreasing cost, the system configurations are islanded (highest), separated, NEM, retail, hybrid retail/wholesale, and wholesale (lowest). The resulting system design balances between the capital and maintenance cost components, the operation costs (i.e., electricity costs) and the additional market revenues. The integration of solar PV and electrolysis is shown to provide a mutually beneficial relationship. For PV, integration with electrolysis offers the potential to hedge against wholesale market price volatility, and integration with electrolysis may offer the potential to defer or avoid transmission investment to deliver power to the point-of-use and instead use it on-site. When compared with SMR without considering any renewable hydrogen premiums, this study finds that PV + Electrolysis systems with current costs are likely not competitive; however, with cost reductions for electrolysis equipment consistent with DOE projections, it was found that systems with wholesale market access would be competitive, largely on account of both low capital costs and low-cost electricity. The electrolysis units can provide greater flexibility than is required based on retail rate optimization, so there is an opportunity for a utility or CAISO to increase system flexibility with PV + Electrolysis systems in return for commensurate compensation. In this way, there are potentially several solutions that fall between the hybrid configuration and the wholesale configuration that could provide sufficient compensation for a PV + Electrolysis unit to compete with SMR while also providing greater flexibility to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isobutanol Octane Blending Model with Gasoline: Cooperative Research and Development Final Report, CRADA Number CRD-17-00689

The purpose of this agreement between the National Renewable Energy Laboratory (NREL) and Gevo, under the DOE Small Business Vouchers Pilot, is to develop a predictive octane blending model for isobutanol and blendstocks for oxygenated blending (BOBs). Validated models of ethanol octane blending effects are currently used in refinery blending models. While it is known that isobutanol increases octane when blended into BOBs, the effect is non-linear, and dependent on hydrocarbon blendstock properties. Because no predictive model currently exists for isobutanol and BOBs, blenders must perform expensive and time-consuming tests to determine the octane effect on each batch of finished fuel. NREL will make basic measurements of research octane number (RON) and motor octane number (MON) of finished gasoline-isobutanol blends prepared in a broad range of BOBs. The key properties and detailed composition of BOBs utilized will be measured by NREL. Using these measured fuel properties, NREL will develop a predictive octane blending model for isobutanol in BOBs that can be used by terminals to further reduce barriers to market penetration of isobutanol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Picking an Open Source License at LLNL: Guidance and Recommendations from the Computing Directorate

Science and innovation are at the core of LLNL’s mission, and open source software is a vehicle by which LLNL innovations reach the scientific community, the nation, and the world. It also serves as a vehicle for building collaborations, publicizing our capabilities, and attracting new employees. Over half of the software produced by LLNL is open source, and open source licenses are the legal tools that allow our software to be used widely. Choosing an appropriate license can be difficult, but it can be even more difficult to change licenses after your software has amassed a significant number of contributors, so it is important understand the potentially subtle implications of your license choice. This document provides a set of recommendations for the busy and uninitiated. They are not set in stone (there are always exceptions). Our goal is to provide default choices that align best with LLNL’s mission, along with a high-level rationale.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Static load test of Arquin-designed CMU wall.

The Arquin Corporation has developed a new method of constructing CMU (concrete masonry unit) walls. This new method uses polymer spacers connected to steel wires that serve as reinforcing as well as means of accurately placing the spacers so that the concrete block can be dry stacked. The hollows of the concrete block used in constructing the wall are then filled with grout. As part of a New Mexico Small Business Assistance Program (NMSBAP), Sandia National Laboratories conducted a series of tests that statically loaded wall segments to compare the Arquin method to a more traditional method of constructing CMU walls. A total of 12 tests were conducted, three with the Arquin method using a W5 reinforcing wire, three with the traditional method of construction using a number 3 rebar as reinforcing, three with the Arquin method using a W2 reinforcing wire, and three with the traditional construction method but without rebar. The results of the tests showed that the walls constructed with the Arquin method and with a W5 reinforcing wire withstood more load than any of the other three types of walls that were tested.

36 MATERIALS SCIENCE↗