Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

LBNF Hadron Absorber: Mechanical Design and Analysis for 2.4MW Operation

Fermilab’s Long-Baseline Neutrino Facility (LBNF) requires an absorber, essentially a large beam dump consisting of actively cooled aluminum and steel blocks, at the end of the decay pipe to stop leftover beam particles and provide radiation protection to people and groundwater. At LBNF’s final beam power of 2.4 MW and assuming the worst case condition of a 204 m long helium filled decay pipe, the absorber is required to handle a heat load of about 750 kW. This results in significant thermal management challenges which have been mitigated by the addition of an aluminum ‘spoiler’ and ‘sculpting’ the central portion of the aluminum core blocks. These thermal effects induce structural stresses which can lead to fatigue and creep considerations. Various accident conditions are considered and safety systems are planned to monitor operation and any accident pulses. Results from these thermal and structural analyses will be presented as well as the mechanical design of the absorber. The design allows each of the core blocks to be remotely removed and replaced if necessary. A shielded remote handling structure is incorporated to hold the hadron monitor when it is removed from the beam.

Hartsell, B.↗

A current modulation in the Gd{sub 2}O{sub 3}/Si/Gd{sub 2}O{sub 3} quantum well structure as a mean to monitor oxygen vacancies

The Gd{sub 2}O{sub 3} layer grown by electron beam evaporation system normally leads to oxygen deficient sites unless the oxygen partial pressure is provided. These oxygen vacancies were monitored through their current modulating effect. This modulation controlled the current within a Si well of the Gd{sub 2}O{sub 3}/Si/Gd{sub 2}O{sub 3} quantum well structure through the migration of the oxygen vacancies. Such behavior were not found in the structure that contains far less oxygen vacancy such as SiO{sub 2}/Si/SiO{sub 2} structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-T-198: Comparison Between a PTW MicroDiamond Dosimeter and a Markus Chamber in a 62 MeV/n Carbon Ion Beam

Purpose: To investigate the linear energy transfer (LET) dependence of a PTW Freiburg microDiamond dosimeter, we compared its response to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Methods: The response of both detectors has been studied as a function of depth in graphite by adding or removing graphite plates in front of the detectors. To account for fluctuations of the beam, we used two setups with different monitor chambers. The depth of the effective point of measurement of both detectors has been converted into a graphite equivalent depth using ICRU Report 73 data. As recommended by IAEA TRS-398, the response of the Markus chamber has been corrected for temperature, pressure, polarity effects and ion recombination. The latter required an additional experiment; to quantify the effect of volume recombination and initial recombination, measurements have been performed at different voltages and different dose rates. Results: As expected, the dominant process leading to ion recombination for carbon ion beam is the initial recombination. At the entrance, the ion recombination correction equals 1.1% and the value is approximately constant in the plateau region. Due to the increase of the LET in the Bragg peak region, we observe a strong increase of the ion recombination correction, up to 6.1% at the distal edge. Comparison between the microDiamond response and the Markus chamber response shows good agreement in the plateau region. However, we observe a 13.6% under response of the microDiamond in the Bragg peak. Conclusion: Increasing between 1% and 6%, the depth dependent ion recombination correction has to be applied to the Markus response. The comparison between the microDiamond and the Markus chamber indicates that there is an under-response of the microDiamond in the vicinity of the Bragg peak due to the increased LET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended fast-ion D-alpha diagnostic on DIII-D

A fast-ion deuterium-alpha (FIDA) diagnostic, first commissioned on DIII-D in 2005, relies on Doppler-shifted light from charge-exchange between beam neutrals and energetic ions. The second generation (2G) system was installed on DIII-D in 2009. Its most obvious improvement is the spatial coverage with 11 active in-beam and three passive off-beam views; the latter allows for simultaneous monitoring of the background signal. Providing extended coverage in fast-ion velocity space, the new views possess a more tangential component with respect to the toroidal field compared to their first generation counterparts. Each viewing chord consists of a bundle of three 1.5 mm core fibers to maximize light gathering. For greater throughput, fast f/1.8 optical components are used throughout. The signal is transmitted via fiber optics to a patch panel, so the user is able to choose the detector. FIDA was originally installed with a spectrometer and charge-coupled device (CCD) camera to monitor the full D{sub {alpha}} spectrum for two spatial views. 2G adds another spectrometer and CCD that monitor the blue-shifted wing for six spatial views at 1 kHz. In addition, a photomultiplier tube and fast digitizer provide wavelength-integrated signals at 1 MHz for eight spatial views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Loss Control and Monitoring Systems for NSLS-Ii

The tunnel shielding design for the NSLS-II will provide adequate protection for beam losses up to 13nC/min or 100% of the maximum top-off injection beam current to be lost in the two periods of the ring around the injection point, while the remainder of the ring is shielded for lower losses of 1.1nC/min or ≤10% of the maximum top-off injected beam current. Additional local shielding of potential loss points in the injection region (e.g. injection septum) will be used to increase the level of loss allowed at these location during 1 Hz injection (i.e. nonTop-off injection). This shielding design will require a system to insure that beam losses don’t exceed these levels for a period of time that could potentially cause levels of radiation outside the shield walls to exceed administrative levels. This Loss Control and Monitoring (LCM) system will provide a level of loss control, loss location measurements and provide alarm indication of the level of beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators and scrapers that will provide limits to the beam miss-steering and control the loss points of the charge, and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications or administrative levels. This will require some new ideas in beam loss detection capability and collimation. The system is not intended to trip interlocks (dumping beam or terminating injection) but only to alarm that higher than normal beam power losses are observed and report where it is occurring. If the alarms conditions are not corrected within a time limit, top-off injection could be slowed down, thereby reducing the beam loss and the radiation it may be producing.

36 MATERIALS SCIENCE↗

Measurement of the energy distribution of an intense electron beam in an external magnetic field

An energy analyzer device has been developed which utilizes a series of stacked foils and Rogowski current monitors to the measure time resolved current of an intense electron beam. The energy distribution of the electron beam is unfolded from measured current ratios using computer simulations. This device is particularly useful where electron beams are guided by external magnetic fields which may make other electron energy measurement techniques difficult. This technique was used to determine the energy distribution of a 550 keV, 95 kA electron beam as it propagates in the gas mixture of a high power KrF laser. The resulting energy distributions at various depths in the gas are in agreement with three-dimensional particle-in-cell simulations providing confidence in the measurement technique.

43 PARTICLE ACCELERATORS↗

Secondary electron emission from a charged dielectric in the presence of normal and oblique electric fields

The secondary electron emission coefficient was obtained for a FEP-Teflon dielectric charged with monoenergetic electrons normally incident upon the surface of the specimen. Measurements of secondary emission coefficient were done for normal and oblique incidence with different primary beam energies in the presence of normal and oblique electric fields. A collimated probing beam was directed to different points on the surface of the specimen and the released or accumulated charge was monitored using an electrometer. The measured data for different probing beam energies, different impact points and different angles of incidence were plotted vs. impact energy and impact point. Data analyzed by computer simulations to find the potential distribution on the surface of the specimen and the electric field around it, is presented and discussed.

Javidi, B.↗

Independent dose per monitor unit review of eight U.S.A. proton treatment facilities

Purpose: Compare the dose per monitor unit at different proton treatment facilities using three different dosimetry methods. Methods: Measurements of dose per monitor unit were performed by a single group at eight facilities using 11 test beams and up to six different clinical portal treatment sites. These measurements were compared to the facility reported dose per monitor unit values. Results: Agreement between the measured and reported doses was similar using any of the three dosimetry methods. Use of the ICRU 59 N{sub D,w} based method gave results approximately 3% higher than both the ICRU 59 N{sub X} and ICRU 78 (TRS-398) N{sub D,w} based methods. Conclusions: Any single dosimetry method could be used for multi-institution trials with similar conformity between facilities. A multi-institutional trial could support facilities using both the ICRU 59 N{sub X} based and ICRU 78 (TRS-398) N{sub D,w} based methods but use of the ICRU 59 N{sub D,w} based method should not be allowed simultaneously with the other two until the difference is resolved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gas-laser power monitor

Device attaches simply to front of laser housing for continuous monitoring of power output. Monitor is calibrated to read either total output or power generated in test volume. It is fabricated from four black-anodized aluminum parts; crown glass positioned at Brewster angle reflects 0.33 percent of beam onto photodiode calibrated for electrical output proportional to laser power. Unlike conventional calorimeter, monitor does not interrupt laser beams, and fast-response diode allows instantaneous tracking of power fluctuations.

Russ, C. E., Jr.↗

SU-E-T-595: Output Factor Calculation for a Uniform Scanning Proton Therapy System

Purpose: To develop an analytical model that predicts dose output factors for patient treatment fields in a uniform scanning proton therapy system. Methods: A model to predict output factors for patient specific treatment fields was produced based on the methods developed by Kooy et al. (2003). The Kooy model predicts the output factor based on the ratio of the entrance dose under calibration conditions to that for a given range and modulation corrected for the inverse square effect. Field specific output factors were plotted as a function of a single parameter r, where r = (Range-Modulation)/Modulation. The model targeted user range 1 sub-span 3 through user range 2 sup-span 2 of the IBA uniform scanning proton therapy system. The data set included points measured using the 10 cm and 18 cm snout sizes to eliminate stem effects on the monitor unit chambers. The data was fit using equation 15 from Kooy et al. (2003), and the resulting model was tested against measurements that were not included in the original data set. Results: For the range and sub span investigated, 120 data points were tested against the model prediction. The model predicted the output factor within 2% for 96% of the points tested and within 2.5% for 99% of the points tested. All points were within 3% of the predicted values. Conclusion: Monitor units for patient treatment fields with proton ranges that fall within the tested interval can be predicted using a model based on the methods developed at MGH. With further evaluation, it will be possible to model all user ranges and sub-spans of the IBA system. Further testing is also needed to predict output factors using a 25 cm snout which introduces variable scanning pattern sizes and stem effects on the monitor unit chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-213-02: Characterization of the Effect of a New Commercial Transmission Detector On Radiotherapy Beams

Purpose: To evaluate the influence of a new commercial transmission detector on radiotherapy beams of various energies. Methods: A transmission detector designed for online treatment monitoring was characterized on a TrueBeam STx linear accelerator with 6MV, 6FFF, 10MV, and 10FFF beams. Measurements of beam characteristics including percentage depth doses (PDDs), inplane and crossplane off-axis profiles at different depths, transmission factors, and skin dose were acquired at field sizes of 3×3cm, 5×5m, 10×10cm, and 20×20cm at 100cm and 80cm source-to-surface distance (SSD). All measurements were taken with and without the transmission detector in the path of the beam. A CC04 chamber was used for all profile and transmission factor measurements. Skin dose was assessed at 100cm, 90cm, and 80cm SSD and using a variety of detectors (Roos and Markus parallel-plate chambers, and OSLD). Results: The PDDs showed small differences between the unperturbed and perturbed beams for both 100cm and 80cm SSD (≤4mm dmax difference and <1.2% average profile difference). The differences were larger for the flattened beams and at larger field sizes. The off-axis profiles showed similar trends. The penumbras looked similar with and without the transmission detector. Comparisons in the central 80% of the profile showed a maximum average (maximum) profile difference between all field sizes of 0.756% (1.535%) and 0.739% (3.682%) for 100cm and 80cm SSD, respectively. The average measured skin dose at 100cm (80cm) SSD for 10×10cm field size was <4% (<35%) dose increase for all energies. For 20×20cm field size, this value increased to <10% (≤45%). Conclusion: The transmission detector has minimal effect on the clinically relevant radiotherapy beams for IMRT and VMAT (field sizes 10×10cm and less). For larger field sizes, some perturbations are observable which would need to be assessed for clinical impact. The authors of this publication has research support from IBA Dosimetry.

60 APPLIED LIFE SCIENCES↗

Xilinx Kintex-UltraScale Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

This is an independent investigation that evaluates the single event destructive and transient susceptibility of the Xilinx Kintex-UltraScale device. Design/Device susceptibility is determined by monitoring the device under test (DUT) for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) is monitored throughout heavy-ion testing by examining device current. This device does not have embedded mitigation. Hence, user implemented mitigation is investigated using Synopsys mitigation tools.

Single Event Transient (SET)↗

Efficient Generation of Large Number-Path Entanglement Using Only Linear Optics and Feed-Forward

We show how an idealized measurement procedure can condense photons from two modes into one and how, by feeding forward the results of the measurement, it is possible to generate efficiently superposition states commonly called N00N states. For the basic procedure sources of number states leak onto a beam splitter, and the output ports are monitored by photodetectors. We find that detecting a fixed fraction of the input at one output port suffices to direct the remainder to the same port, with high probability, however large the initial state. When instead photons are detected at both ports, macroscopic quantum superposition states are produced. We describe a linear-optical circuit for making the components of such a state orthogonal, and another to convert the output to a N00N state. Our approach scales exponentially better than existing proposals. Important applications include quantum imaging and metrology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulations in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam MC literature. This work has been partially funded by Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

60 APPLIED LIFE SCIENCES↗

Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and {sup 60}Co γ-rays

Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference {sup 60}Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a {sup 60}Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to {sup 60}Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2–40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. Conclusions: The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and {sup 60}Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.

60 APPLIED LIFE SCIENCES↗

Influence of adsorption kinetics on stress evolution in magnetron-sputtered SiO{sub 2} and SiN{sub x} films

An in situ multi-beam optical sensor system was used to monitor and analyze the force per unit width (F/w) and stress evolution during several stages in magnetron-sputtered SiO{sub 2} and SiN{sub x} films. Stress was observed to relieve quickly after interrupt and recover rapidly after growth resumption in both films. Stress relief was reversible in SiO{sub 2} film but partial reversible in SiN{sub x} film. Stress relief results from both physical and chemical adsorption. Stress recovery is caused by physical desorption. And chemical adsorption results in an irreversible stress relief component. No chemical adsorption occurs in SiO{sub 2} film because of the stable chemical structure. The relationship between adsorption kinetics and films' mechanical behavior is revealed.

36 MATERIALS SCIENCE↗

the D0 Luminosity Monitor operations and performance

The D0 Luminosity Monitor (LM) plays a crucial role in D0 physics analyses by providing the normalization for many cross section measurements. The detector consists of two sets of 24 scintillator wedges read out with photomultiplier tubes. The detector is located in the forward regions surrounding the beam pipe, covering a pseudo-rapidity range of 2.7 < |{eta}| < 4.4. The LM is sensitive to a large fraction of the total inelastic cross section and measures the luminosity by counting the number of empty proton-antiproton bunch crossings, using Poisson statistics to extract the instantaneous luminosity. The techniques used to convert the measurements made by the LM into the assessed luminosity will be discussed, as well as the performance and operational details of the detector.

43 PARTICLE ACCELERATORS↗