Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Pulse-modulated dual-gas control subsystem for space cabin atmosphere

An atmosphere control subsystem (ACS) was developed for use in a closed manned cabin, such as the Space Shuttle Orbiter. This subsystem uses the Perkin Elmer mass spectrometer for continuous measurement of major atmospheric constituents (H2, H2O, N2, O2, and CO2). The O2 and N2 analog signals are used as inputs to the controller, which produces a pulse-frequency-modulated output to operate the N2 gas admission solenoid valve and an on-off signal to operate the O2 valve. The proportional controller characteristic results in improved control accuracy as compared with previously used on-off controllers having significant dead-band. A 60-day evaluation test was performed on the ACS during which operation was measured at various values of control setpoint and simulated cabin leakage.

Jackson, J. K.↗

Preliminary design of a Primary Loop Pump Assembly (PLPA), using electromagnetic pumps

A preliminary design study of flight-type dc conduction-permanent magnetic, ac helical induction, and ac linear induction pumps for circulating 883 K (1130 F) NaK at 9.1 kg/sec (20 lb/sec) is described. Various electromagnetic pump geometrics are evaluated against hydraulic performance, and the effects of multiple windings and numbers of pumps per assembly on overall reliability were determined. The methods used in the electrical-hydraulic, stress, and thermal analysis are discussed, and the high temperature electrical materials selected for the application are listed.

Moss, T. A.↗

Is the red arc a good indicator of ionosphere-magnetosphere conditions

Weak red arcs were observed on the two consecutive nights of July 12-13 and July 13-14, 1969, at Richland, Washington, whereas no red arcs were detectable on the nights preceding and following the observations. Satellite (Ogo 6) data of electron temperature and density, low-frequency ac electric field, and suprathermal electron flux corresponding to the conjugate region of Richland show no significant variations during these days. The data show elevated electron temperatures and enhanced low-frequency ac noise levels at the expected red arc position in the neighborhood of the density trough, as indicated by previous observations. The data appear to indicate that the optical criterion of red arc occurrence would lead to the conclusion of significantly different ionosphere-magnetosphere conditions during these four nights, whereas the more detailed in situ data show that the conditions were very similar.

Nagy, A. F.↗

Performance characteristics of the U.VA. superconducting wind tunnel balance

Initial operational characteristics of a wind tunnel electromagnetic balance utilizing superconducting coils are reported. Both dc and ac superconducting coils are used for balancing and measuring 3-component aerodynamic forces on simple models in Mach 3, room temperature flow. Liquid helium boil-off measurements corresponding to a wide range of operating conditions are presented together with results of systematic ac losses scaling experiments using various pancake coils wound with superconducting tape. This unique prototype facility is primarily for studying the practical feasibility of using superconducting magnetic suspension techniques for aerodynamic testing and accumulating the knowledge and expertise required for extrapolating these techniques to large-scale facilities.

Humphris, R. R.↗

Solar electric propulsion thrust beam interactive effects

Interactive effects between ion engine thrust beams and an SEP spacecraft and its science payload have been examined. AC electric contamination from thrust beam potential fluctuations of both 'common mode' and 'point-to-point' forms has been evaluated. Quenching of point-to-point E-fields by both thrust ion and charge exchange ion plasmas is expected. Reduction methods for AC electric contamination from common mode thrust beam potential fluctuations have been developed. Charged particle contamination of ambient space and plasma wave contamination may result from density magnitude and spatial extent of charge exchange plasma plumes. Reduction methods for cone of directions of high angle charge exchange ions have been examined.

Sellen, J. M., Jr.↗

VLF-emissions from ring current electrons. An interpretation of the band of missing emissions

VLF-emissions associated with the enhancement of ring current electrons during magnetic storms and substorms which were detected by the equatorially orbiting S-A satellite (Explorer 45) are described. The emissions observed near the geomagnetic equator consist of essentially two frequency regimes, i.e., one above the electron gyrofrequency, f sub H at the equator and the other below f sub H. This is indicated as a part of the wide-band data obtained during the main phase of the December 17, 1971 magnetic storm. The upper figure is the ac-magnetic field data measured by the search-coil magnetometer with the upper cutoff of 3kHz and the lower figure is the ac-electric field data obtained by the electric field sensor with the upper cutoff of 10kHz. These figures show the time sequence of the observed emissions along the inbound orbit (No. 101) of the satellite as f sub H changes approximately from 3 kHz at 20 UT to 6 kHz at 21 UT. The emissions above f sub H are electrostatic mode, which peak near the frequencies of (n + 1/2) f sub H where n is positive integer, and sometimes emissions up to n = 10 are observed. The emissions below f sub H are whistler mode, which have a conspicuous gap along exactly half electron gyrofrequency, f sub H/2.

Maeda, K.↗

The development of a portable cardiac ultrasonoscope

This paper describes a new, portable, battery powered echocardioscope developed at the NASA-Ames Research Center in cooperation with the Stanford University School of Medicine. This instrument has three major advantages over existing equipment. First, it is compact and light weight for easy portability. Second, its DC operation makes it safer to use in remote settings where AC power is unavailable or in intensive care and neonatal units where AC instruments could present electrical hazards for the patient. Third, its design and packaging should enable it to sell for several thousand dollars less than presently marketed ultrasonoscopes. The cooperative development of this instrument, its principles of operation, and the significance of its unique features are presented.

Schmidt, G.↗

Mass spectrometer has wide angular acceptance

Higher mass resolution is achieved by replacing conventional mass/velocity spectrometers with system of planar ac-modulated grids. System gives focusing for all angles of incidence. Ac-modulation and detection scheme minimizes sensitivity to light and other types of radiation.

Neugebauer, M. M.↗

Design study for LANDSAT D attitude control system

A design and performance evaluation is presented for the LANDSAT D attitude control system (ACS). Control and configuration of the gimballed Ku-band antenna system for communication with the tracking and data relay satellite (TDRS). Control of the solar array drive considered part of the ACS is also addressed.

Iwens, R. P.↗

Photoelectron spectrometer with means for stabilizing sample surface potential

An improved X-ray photoelectron spectrometer is disclosed, which includes circuit means to determine the surface potential of a sample, e.g., an insulator. The circuit means comprise an electron gun, whose potential is modulated at a preselected frequency above and below a selected potential with respect to the spectrometer common potential, e.g., ground. The beam of electrons is directed to the sample surface. The sample's surface potential is offset by an offset power supply with respect to the spectrometer common potential until the ac current which flows through the sample reaches a peak amplitude. A lock-in amplifier is included to measure the ac current in phase with the modulating frequency.

Grunthaner, F. J.↗

The communications industry's requirements and interests

Of interest to the communications industry are the amplitude, waveshape, duration and frequency of lightning-originated voltage surges and transients on the communications network, including the distribution system and AC power supply circuits. The cloud-to-ground lightning discharge and its characteristics are thought to be most meaningful. Of specific interest are peak current, waveshape, number of flashes, strokes per flash, and zone of influence. Accurate and meaningful lightning data at the local level (telephone district office) is necessary for a decision on the appropriate protection level. In addition to lightning, the protection engineer must consider other factors such as: AC induction, switching surges, ground potential rise, soil resistivity, bonding and grounding techniques, shielding and isolation, and exposure of the telephone loop.

Wanaselja, O.↗

Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 1

Electrical characterization and qualification tests were performed on the RCA MWS5001D, 1024 by 1-bit, CMOS, random access memory. Characterization tests were performed on five devices. The tests included functional tests, AC parametric worst case pattern selection test, determination of worst-case transition for setup and hold times and a series of schmoo plots. The qualification tests were performed on 32 devices and included a 2000 hour burn in with electrical tests performed at 0 hours and after 168, 1000, and 2000 hours of burn in. The tests performed included functional tests and AC and DC parametric tests. All of the tests in the characterization phase, with the exception of the worst-case transition test, were performed at ambient temperatures of 25, -55 and 125 C. The worst-case transition test was performed at 25 C. The preburn in electrical tests were performed at 25, -55, and 125 C. All burn in endpoint tests were performed at 25, -40, -55, 85, and 125 C.

Klute, A.↗

Electrical Evaluation of RCA MWS5501D Random Access Memory, Volume 2, Appendix a

The electrical characterization and qualification test results are presented for the RCA MWS5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. The address access time, address readout time, the data hold time, and the data setup time are some of the results surveyed.

Klute, A.↗

Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 3, Appendix B

The electrical characterization and qualification test results are presented for the RCA MWS5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. The test values for the output voltage, average input current, the supply current and the leakage current are presented.

Klute, A.↗

Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 4, Appendix C

The electrical characterization and qualification test results are presented for the RCA MWS5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. Statistical analysis data is supplied along with write pulse width, read cycle time, write cycle time, and chip enable time data.

Klute, A.↗

Electrical Evaluation of RCA MWS5001D Random Access Memory, Volume 5, Appendix D

The electrical characterization and qualification test results are presented for the RCA MWS 5001D random access memory. The tests included functional tests, AC and DC parametric tests, AC parametric worst-case pattern selection test, determination of worst-case transition for setup and hold times, and a series of schmoo plots. Average input high current, worst case input high current, output low current, and data setup time are some of the results presented.

Klute, A.↗

Effects of aeration on formation and localization of the acetyl coenzyme A synthetases of Saccharomyces cerevisiae

Previous studies on the yeast Saccharomyces cerevisiae have shown that two different forms of the enzyme acetyl coenzyme A synthetase (ACS) are present, depending on the conditions under which the cells are grown. The paper evaluates the usefulness of a method designed to assay both synthetases simultaneously in yeast homogenates. The data presented confirm the possibility of simultaneous detection and estimation of the amount of both ACSs of S. cerevisiae in crude homogenates of this strain, making possible the study of physiological factors involved in the formation of these isoenzymes. One important factor for specifying which of the two enzymes is found in these yeast cells is the presence or absence of oxygen in their environment. Aeration not only affects the ratio of the two ACSs but also appears to affect the cellular distribution of these enzymes. Most of the data presented suggest the possibility that the nonaerobic ACS may serve as a precursor to the aerobic form.

Klein, H. P.↗

Prediction of solar induced currents and effects on power transmission systems in central Canada

The auroral-electrojet zone covers three quarters of Manitoba and consequently, solar storms strongly affect transmission lines. Harmonics are generated at transformers due to the saturation of their cores by induced currents, and the level of harmonics produced may cause malfunction of control relays, and yield unacceptable distortions in normal ac waveforms. The expected effects of long ac transmission systems were studied with emphasis on a 500 kv line to be built from Winnipeg to Minneapolis-St. Paul. Spectral analysis of induced current records from Manitoba Hydro's LaVerendrye station and magnetograms from IMS stations in Manitoba were used along with results of Campbell's work on the Alaskan pipeline induction problem (1978) in order to predict periodic and surge currents. It is concluded that the surge currents will produce significant levels of harmonics and corresponding operating problems during magnetic storms.

Goddard, W. R.↗