Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variance estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Neural network denoising of x-ray images from high-energy-density experiments

Noise is a consistent problem for x-ray transmission images of High-Energy-Density (HED) experiments because it can significantly affect the accuracy of inferring quantitative physical properties from these images. We consider experiments that use x-ray area backlighting to image a thin layer of opaque material within a physics package to observe its hydrodynamic evolution. The spatial variance of the x-ray transmission across the system due to changing opacity serves as an analog for measuring density in this evolving layer. The noise in these images adds nonphysical variations in measured intensity, which can significantly reduce the accuracy of our inferred densities, particularly at small spatial scales. Denoising these images is thus necessary to improve our quantitative analysis, but any denoising method also affects the underlying information in the image. In this paper, we present a method for denoising HED x-ray images via a deep convolutional neural network model with a modified DenseNet architecture. In our denoising framework, we estimate the noise present in the real (data) images of interest and apply the inferred noise distribution to a set of natural images. These synthetic noisy images are then used to train a neural network model to recognize and remove noise of that character. We show that our trained denoiser network significantly reduces the noise in our experimental images while retaining important physical features.

47 OTHER INSTRUMENTATION↗

Analysis of fractal dimensions of rat bones from film and digital images

OBJECTIVES: (1) To compare the effect of two different intra-oral image receptors on estimates of fractal dimension; and (2) to determine the variations in fractal dimensions between the femur, tibia and humerus of the rat and between their proximal, middle and distal regions. METHODS: The left femur, tibia and humerus from 24 4-6-month-old Sprague-Dawley rats were radiographed using intra-oral film and a charge-coupled device (CCD). Films were digitized at a pixel density comparable to the CCD using a flat-bed scanner. Square regions of interest were selected from proximal, middle, and distal regions of each bone. Fractal dimensions were estimated from the slope of regression lines fitted to plots of log power against log spatial frequency. RESULTS: The fractal dimensions estimates from digitized films were significantly greater than those produced from the CCD (P=0.0008). Estimated fractal dimensions of three types of bone were not significantly different (P=0.0544); however, the three regions of bones were significantly different (P=0.0239). The fractal dimensions estimated from radiographs of the proximal and distal regions of the bones were lower than comparable estimates obtained from the middle region. CONCLUSIONS: Different types of image receptors significantly affect estimates of fractal dimension. There was no difference in the fractal dimensions of the different bones but the three regions differed significantly.

NASA Discipline Musculoskeletal↗

Thinking outside the box: effects of modes larger than the survey on matter power spectrum covariance

Accurate power spectrum (or correlation function) covariance matrices are a crucial requirement for cosmological parameter estimation from large scale structure surveys. In order to minimize reliance on computationally expensive mock catalogs, it is important to have a solid analytic understanding of the different components that make up a covariance matrix. Considering the matter power spectrum covariance matrix, it has recently been found that there is a potentially dominant effect on mildly non-linear scales due to power in modes of size equal to and larger than the survey volume. This beat coupling effect has been derived analytically in perturbation theory and while it has been tested with simulations, some questions remain unanswered. Moreover, there is an additional effect of these large modes, which has so far not been included in analytic studies, namely the effect on the estimated average density which enters the power spectrum estimate. In this article, we work out analytic, perturbation theory based expressions including both the beat coupling and this local average effect and we show that while, when isolated, beat coupling indeed causes large excess covariance in agreement with the literature, in a realistic scenario this is compensated almost entirely by the local average effect, leaving only ∼ 10% of the excess. We test our analytic expressions by comparison to a suite of large N-body simulations, using both full simulation boxes and subboxes thereof to study cases without beat coupling, with beat coupling and with both beat coupling and the local average effect. For the variances, we find excellent agreement with the analytic expressions for k < 0.2 hMpc{sup −1} at z = 0.5, while the correlation coefficients agree to beyond k = 0.4 hMpc{sup −1}. As expected, the range of agreement increases towards higher redshift and decreases slightly towards z = 0. We finish by including the large-mode effects in a full covariance matrix description for arbitrary survey geometry and confirming its validity using simulations. This may be useful as a stepping stone towards building an actual galaxy (or other tracer's) power spectrum covariance matrix.

79 ASTRONOMY AND ASTROPHYSICS↗

Geographical representation of radial orbit perturbations due to ocean tides: Implications for satellite altimetry

In analogy to the geographical representation of the zeroth-order radial orbit perturbations due to the static geopotential, similar relationships have been derived for radial orbit perturbations due to the ocean tides. At each location these perturbations are seen to be coherent with the tide height variations. The study of this singularity is of obvious importance to the estimation of ocean tides from satellite altimeter data. We derive analytical expressions for the sensitivity of altimeter derived ocean tide models to the ocean tide force model induced errors in the orbits of the altimeter satellite. In particular, we focus on characterizing and quantifying the nonresonant tidal orbit perturbations, which cannot be adjusted into the empirical accelerations or radial perturbation adjustments commonly used during orbit determination and in altimeter data processing. As an illustration of the utility of this technique, we study the differences between a TOPEX/POSEIDON-derived ocean tide model and the Cartwright and Ray 1991 Geosat model. This analysis shows that nearly 60% of the variance of this difference for M(sub 2) can be explained by the Geosat radial orbit eror due to the omission of coefficients from the GEM-T2 background ocean tide model. For O(sub 1), K(sub 1), S(sub 2), and K(sub 2) the orbital effects account for approximately 10 to 40% of the variances of these differences. The utility of this technique to assessment of the ocean tide induced errors in the TOPEX/POSEIDON-derived tide models is also discussed.

Bettadpur, Srinivas V.↗

Uncertainty of Passive Imager Cloud Optical Property Retrievals to Instrument Radiometry and Model Assumptions: Examples from MODIS

The optical and microphysical structure of clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS on the NASA EOS Terra and Aqua platforms, simultaneous global-daily 1 km retrievals of cloud optical thickness (COT) and effective particle radius (CER) are provided, as well as the derived water path (WP). The cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate retrieval datasets for various two-channel retrievals, typically a VISNIR channel paired with a 1.6, 2.1, and 3.7 m spectral channel. The MOD06 forward model is derived from on a homogeneous plane-parallel cloud. In Collection 5 processing (completed in 2007 with a modified Collection 5.1 completed in 2010), pixel-level retrieval uncertainties were calculated for the following non-3-D error sources: radiometry, surface spectral albedo, and atmospheric corrections associated with model analysis uncertainties (water vapor only). The latter error source includes error correlation across the retrieval spectral channels. Estimates of uncertainty in 1 aggregated (Level-3) means were also provided assuming unity correlation between error sources for all pixels in a grid for a single day, and zero correlation of error sources from one day to the next. I n Collection 6 (expected to begin in late summer 2013) we expanded the uncertainty analysis to include: (a) scene-dependent calibration uncertainty that depends on new band and detector-specific Level 1B uncertainties, (b) new model error sources derived from the look-up tables which includes sensitivities associated with wind direction over the ocean and uncertainties in liquid water and ice effective variance, (c) thermal emission uncertainties in the 3.7 m band associated with cloud and surface temperatures that are needed to extract reflected solar radiation from the total radiance signal, (d) uncertainty in the solar spectral irradiance at 3.7 m, and (e) addition of stratospheric ozone uncertainty in visible atmospheric corrections. A summary of the approach and example Collection 6 results will be shown.

Cloud Properties Observations↗

Planck 2013 results. XXIII. Isotropy and statistics of the CMB

The two fundamental assumptions of the standard cosmological model-that the initial fluctuations are statistically isotropic and Gaussian-are rigorously tested using maps of the cosmic microwave background (CMB) anisotropy from the Planck satellite. The detailed results are based on studies of four independent estimates of the CMB that are compared to simulations using a fiducial ΛCDM model and incorporating essential aspects of the Planck measurement process. Deviations from isotropy have been found and demonstrated to be robust against component separation algorithm, mask choice, and frequency dependence. Many of these anomalies were previously observed in the WMAP data, and are now confirmed at similar levels of significance (about 3σ). However, we find little evidence of non-Gaussianity, with the exception of a few statistical signatures that seem to be associated with specific anomalies. In particular, we find that the quadrupole-octopole alignment is also connected to a low observed variance in the CMB signal. A power asymmetry is now found to persist on scales corresponding to about &ell; = 600 and can be described in the low-&ell; regime by a phenomenological dipole modulation model. However, any primordial power asymmetry is strongly scale-dependent and does not extend to arbitrarily small angular scales. Finally, it is plausible that some of these features may be reflected in the angular power spectrum of the data, which shows a deficit of power on similar scales. Indeed, when the power spectra of two hemispheres defined by a preferred direction are considered separately, one shows evidence of a deficit in power, while its opposite contains oscillations between odd and even modes that may be related to the parity violation and phase correlations also detected in the data. Although these analyses represent a step forward in building an understanding of the anomalies, a satisfactory explanation based on physically motivated models is still lacking.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical Framework for Identifying and Differentiating Recent Hitchhiking and Severe Bottleneck Effects from Multi-Locus DNA Sequence Data

Hitchhiking and severe bottleneck effects have impact on the dynamics of genetic diversity of a population by inducing homogenization at a single locus and at the genome-wide scale, respectively. As a result, identification and differentiation of the signatures of such events from DNA sequence data at a single locus is challenging. This study develops an analytical framework for identifying and differentiating recent homogenization events at multiple neutral loci in low recombination regions. The dynamics of genetic diversity at a locus after a recent homogenization event is modeled according to the infinite-sites mutation model and the Wright-Fisher model of reproduction with constant population size. In this setting, I derive analytical expressions for the distribution, mean, and variance of the number of polymorphic sites in a random sample of DNA sequences from a locus affected by a recent homogenization event. Based on this framework, three likelihood-ratio based tests are presented for identifying and differentiating recent homogenization events at multiple loci. Lastly, I apply the framework to two data sets. First, I consider human DNA sequences from four non-coding loci on different chromosomes for inferring evolutionary history of modern human populations. The results suggest, in particular, that recent homogenization events at the loci are identifiable when the effective human population size is 50000 or greater in contrast to 10000, and the estimates of the recent homogenization events are agree with the “Out of Africa” hypothesis. Second, I use HIV DNA sequences from HIV-1-infected patients to infer the times of HIV seroconversions. The estimates are contrasted with other estimates derived as the mid-time point between the last HIV-negative and first HIV-positive screening tests. Finally, the results show that significant discrepancies can exist between the estimates.

59 BASIC BIOLOGICAL SCIENCES↗

A data-driven approach to sampling matrix selection for compressive sensing

Sampling is a fundamental aspect of any implementation of compressive sensing. Typically, the choice of sampling method is guided by the reconstruction basis. However, this approach can be problematic with respect to certain hardware constraints and is not responsive to domain-specific context. We propose a method for defining an order for a sampling basis that is optimal with respect to capturing variance in data, thus allowing for meaningful sensing at any desired level of compression. We focus on the Walsh-Hadamard sampling basis for its relevance to hardware constraints, but our approach applies to any sampling basis of interest. We illustrate the effectiveness of our method on the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset, the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset, and a Colorado State University Swiss Ranger depth image dataset. The spectral datasets consist of simulant experiments, including releases of chemicals such as GAA and SF6. We combine our sampling and reconstruction with the adaptive coherence estimator (ACE) and bulk coherence for chemical detection and we incorporate an algorithmic threshold for ACE values to determine the presence or absence of a chemical. We compare results across sampling methods in this context. We have successful chemical detection at a compression rate of 90%. For all three datasets, we compare our sampling approach to standard orderings of sampling basis such as random, sequency, and an analog of sequency that we term `frequency.' In one instance, the peak signal to noise ratio was improved by over 30% across a test set of depth images.

compressive sensing, hyperspectral imaging, Walsh-↗

Quantile-Specific Heritability of Inflammatory and Oxidative Stress Biomarkers Linked to Cardiovascular Disease

Purpose: Heritability (h 2 , the proportion of the phenotypic variance attributable to additive genetic effects) is traditionally assumed to be constant throughout the distribution of the phenotype. However, the heritabilities of circulating C-reactive protein, interleukin-6, plasminogen activator inhibitor type-1 (PAI-1), and monocyte chemoattractant protein-1 (MCP-1) concentrations depend upon whether the phenotype is high or low relative to their distributions (quantile-dependent expressivity), which may account for apparent gene–environment interactions. Whether the heritabilities of other inflammatory biomarkers linked to cardiovascular disease are quantile-dependent remain to be determined. Patients and Methods: Quantile-specific offspring-parent (β OP ) and full-sib regression slopes (β FS ) were estimated by applying quantile regression to the age- and sex-adjusted phenotypes of families surveyed as part of the Framingham Heart Study. Quantile-specific heritabilities were calculated as: h 2 =2β OP /(1+r spouse ) and h 2 ={(1+8r spouse β FS ) 0.5 – 1}/(2r spouse ). Results: Heritability (h 2 ± SE) of lipoprotein-associated phospholipase A2 (Lp-PLA 2 ) mass concentrations increased from 0.11 ± 0.03 at the 10 th percentile, 0.08 ± 0.03 at the 25 th , 0.12 ± 0.03 at the 50 th , 0.20 ± 0.04 at the 75 th , and 0.26 ± 0.06 at the 90 th percentile, or 0.0023 ± 0.0006 per each one-percent increase in the phenotype distribution (P linear trend = 0.0004). Similarly, h 2 increased 0.0029 ± 0.0011 (P linear trend = 0.01) for sP-selectin, 0.0032 ± 0.0009 (P linear trend = 0.0001) for soluble intercellular adhesion molecule 1 (sICAM-1), and 0.0026 ± 0.0006 for tumor necrosis factor receptor 2 (TNFR2) (P linear trend = 5.0 × 10 -6 ) per each one-percent increase in their distributions when estimated from β OP . Osteoprotegerin and soluble ST2 heritability also increased significantly with increasing percentiles of their distributions when estimated from β FS . Lp-PLA 2 activity, CD40 ligand, TNFα, interleukin-18, and myeloperoxidase heritability showed no significant quantile-dependence. Conclusion: The heritabilities of circulating Lp-PLA 2 -mass, sP-selectin, sICAM-1, TNFR2, osteoprotegerin and soluble ST2 concentrations are quantile-dependent, which may contribute to purported genetic modulations of: 1) sP-selectin’s relationships to venous thrombosis, pulmonary hypertension, type 2 diabetes and atorvastatin treatment; 2) sICAM-I’s relationships to brain abscess and atorvastatin treatment; and 3) Lp-PLA 2 ’s relationships to myocardial infarction and preeclampsia.

60 APPLIED LIFE SCIENCES↗

An Analysis of Future Wind Energy Resources and Cost Uncertainties Across the United States

Wind power is a growing source of energy generation that relies on complex global atmospheric and earth system processes. There has been evidence of reductions in average wind speeds over land in North America since the 1980s, and several models project that average wind speeds will continue to decrease. Concurrently, the cost of wind energy systems in the United States has been decreasing since around 2010, a trend also projected to continue. There is considerable uncertainty in these future projections, with quantitative estimates of future wind resource and system costs varying widely. To study this, we run wind energy models with possible future system costs, turbine designs, and meteorological inputs from multiple downscaled earth system models over the contiguous United States. Changes in mean annual energy production from 2000-2019 to 2040-2059 can be as high as +10% in South Texas or as low as -20% in Iowa. Larger turbines and moderate reductions in system costs can offset the largest projected decreases in wind resource, but much uncertainty remains in the extent to which wind resources will change and to what extent system costs can be reduced. An analysis of variance shows, in several states in the Midwest, uncertainty in future wind resources can influence the cost of wind energy nearly as much as uncertainty in future system costs.

17 WIND ENERGY↗

THE LBT BOOeTES FIELD SURVEY. I. THE REST-FRAME ULTRAVIOLET AND NEAR-INFRARED LUMINOSITY FUNCTIONS AND CLUSTERING OF BRIGHT LYMAN BREAK GALAXIES AT Z {approx} 3

We present a deep LBT/LBC U{sub spec}-band imaging survey (9 deg{sup 2}) covering the NOAO Booetes field. A total of 14,485 Lyman break galaxies (LBGs) at z {approx} 3 are selected, which are used to measure the rest-frame UV luminosity function (LF). The large sample size and survey area reduce the LF uncertainties due to Poisson statistics and cosmic variance by {>=}3 compared to previous studies. At the bright end, the LF shows excess power compared to the best-fit Schechter function, which can be attributed to the contribution of z {approx} 3 quasars. We compute the rest-frame near-infrared LF and stellar mass function (SMF) of z {approx} 3 LBGs based on the R-band and [4.5 {mu}m]-band flux relation. We investigate the evolution of the UV LFs and SMFs between z {approx} 7 and z {approx} 3, which supports a rising star formation history in the LBGs. We study the spatial correlation function of two bright LBG samples and estimate their average host halo mass. We find a tight relation between the host halo mass and the galaxy star formation rate (SFR), which follows the trend predicted by the baryonic accretion rate onto the halo, suggesting that the star formation in LBGs is fueled by baryonic accretion through the cosmic web. By comparing the SFRs with the total baryonic accretion rates, we find that cosmic star formation efficiency is about 5%-20% and it does not evolve significantly with redshift, halo mass, or galaxy luminosity.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlated noise in the COBE DMR sky maps

The Cosmic Background Explorer Satellite Differential Radiometer (COBE DMR) sky maps contain low-level correlated noise. We obtain estimates of the amplitude and pattern of the correlated noise from three techniques: angular averages of the covariance matrix, Monte Carlo simulations of two-point correlation functions and direct analysis of the DMR maps. The results from the three methods are mutually consistent. The noise covariance matrix of a DMR sky maps is diagonal to an accuracy of better than 1%. For a given sky pixel, the dominant noise covariance occure with the ring of pixels at an angular separation of 60 deg due to the 60 deg separation of the DMR horns. The mean covariance at 60 deg is 0.45%((sup +0.18)(sub -0.14)) of the mean variance. Additionally, the variance in a given pixel is 0.7% greater than would be expected from a single beam experiment with the same noise properties. Autocorrelation functions suffer from a approximately 1.5 sigma positive bias at 60 deg while cross-correlations have no bias. Published COBE DMR results are not significantly affected by correlated noise.

Lineweaver, C. H.↗

Magnetic field directional discontinuities - Characteristics between 0.46 and 1.0 AU

Based on Mariner 10 data, a statistical survey and an application of the Sonnerup-Cahill variance procedure to a visual identification with 1.2-s averages for time intervals corresponding to the equally spaced heliocentric distances of 1.0, 0.72 and 0.46 AU, are employed to study the characteristics of directional discontinuities (DDs) in the interplanetary magnetic field. Analysis using two methods demonstrated that the ratio of tangential discontinuities (TDs) to rotational discontinuities (RDs) decreased with decreasing radial distance. Decreases in average discontinuity thickness of 41 percent between 1.0 and 0.72 AU, and 56 percent between 1.0 and 0.46 AU, were found for both TDs and RDs, in agreement with Pioneer 10 data between 1 and 5 AU. Normalization of the individual DD thicknesses with respect to the estimated local proton gyroradius (R sub L) gave a nearly constant average thickness at the three locations, 36 + or - 5 R sub L, for both RDs and TDs.

Lepping, R. P.↗

Adaptive Antenna Pattern Notching of Interference in Synthetic Aperture Radar Data Using Digital Beamforming

Radio Frequency Interference (RFI) is a growing problem in Synthetic Aperture Radar (SAR)systems as scientific motivations push the radars to lower frequencies and as more wireless services share the frequency spectrum. New, advanced SAR instruments, such as NASA's EcoSAR, DBSAR and DLR's Tandem-L mission, employ a multichannel architecture capable of Digital Beamforming (DBF). Radars with DBF are capable of notching the antenna pattern in specific directions, which can be utilized to suppress RFI on board or in post-processing. A well-researched beamformer for this purpose is the Minimum Variance Distortionless Response (MVDR) Beamformer. However, the number of interferers that can be removed through notching is limited by the number of receive channels. It is therefore essential to adaptively change the antenna pattern notching throughout the image in time and frequency for the best results with a given number of receive channels. In this paper, we present several methods to achieve this notching by making use of the spatial SAR signal distribution in range time, range frequency, azimuth time and azimuth Doppler that is inherent to the SAR imaging geometry. Because this distribution is time-variable and yet predictable, it can be used to improve the angle of arrival estimation of the RFI and the adaptive notching. The presented methods can be applied to a Digital Beamforming (DBF) SAR signal with multiple channels in elevation and/or in azimuth. Simulations show that the proposed methods increase the ability to notch out-of-swath interference from multiple directions and lessen the impact on in-swath interference. The improvement of the interferometric coherence for a single-pass interferogram acquired by NASA's EcoSAR system (capable of DBF in elevation) is demonstrated. The removal of periodic RFI artifacts is achieved.

RFI↗

Requirements on the gain calibration for LiteBIRD polarisation data with blind component separation

The detection of primordial B modes of the cosmic microwave background (CMB) could provide information about the early stages of the Universe's evolution. The faintness of this signal requires exquisite calibration accuracy and control of instrumental systematic effects which otherwise could bias the measurements. In this work, we study the impact of an imperfect relative polarisation gain calibration on the recovered value of the tensor-to-scalar ratio r for the LiteBIRD experiment, through the application of the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. We derive requirements on the relative calibration accuracy of the overall polarisation gain (Δg ν ) for each LiteBIRD frequency channel. Our results show that minimum variance techniques, as NILC, are less sensitive to systematic gain calibration uncertainties compared to a parametric approach, if the latter is not equipped with a proper modelling of these instrumental effects. In this study, the most stringent requirements are found in the channels where the CMB signal is relatively brighter, with the tightest constraints at 166 GHz (Δg ν ≈ 0.16%). This differs from the outcome of an analogous analysis performed with a parametric method, where the tightest requirements are obtained for the foreground-dominated channels. Gain calibration uncertainties, corresponding to the derived requirements, are then simultaneously propagated into all frequency channels. By doing so, we find that the overall impact on estimated r is lower than the total gain systematic budget for LiteBIRD approximately by a factor 5, due to the correlations of the impacts of gain calibration uncertainties in different frequency channels. In order to decouple the systematic effect from the specific choice of the model, we derive the requirements assuming constant spectral parameters for the foreground emission. To assess the robustness of the obtained results against more realistic scenarios, we repeat the analysis assuming sky models of intermediate and high complexity. In these further cases, we adopt an optimised NILC pipeline, called the Multi-Clustering NILC (MC-NILC). We find that the impact of gain calibration uncertainties on r is lower than the LiteBIRD gain systematics budget for the intermediate-complexity sky model. For the high-complexity case, instead, it would be necessary to tighten the requirements by a factor 1.8.

79 ASTRONOMY AND ASTROPHYSICS↗

Inverse sequential procedures for the monitoring of time series

When one or more new values are added to a developing time series, they change its descriptive parameters (mean, variance, trend, coherence). A 'change index (CI)' is developed as a quantitative indicator that the changed parameters remain compatible with the existing 'base' data. CI formulate are derived, in terms of normalized likelihood ratios, for small samples from Poisson, Gaussian, and Chi-Square distributions, and for regression coefficients measuring linear or exponential trends. A substantial parameter change creates a rapid or abrupt CI decrease which persists when the length of the bases is changed. Except for a special Gaussian case, the CI has no simple explicit regions for tests of hypotheses. However, its design ensures that the series sampled need not conform strictly to the distribution form assumed for the parameter estimates. The use of the CI is illustrated with both constructed and observed data samples, processed with a Fortran code 'Sequitor'.

Radok, Uwe↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗