Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracking errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Multiple symbol partially coherent detection of MPSK

It is shown that by using the known (or estimated) value of carrier tracking loop signal to noise ratio (SNR) in the decision metric, it is possible to improve the error probability performance of a partially coherent multiple phase-shift-keying (MPSK) system relative to that corresponding to the commonly used ideal coherent decision rule. Using a maximum-likeihood approach, an optimum decision metric is derived and shown to take the form of a weighted sum of the ideal coherent decision metric (i.e., correlation) and the noncoherent decision metric which is optimum for differential detection of MPSK. The performance of a receiver based on this optimum decision rule is derived and shown to provide continued improvement with increasing length of observation interval (data symbol sequence length). Unfortunately, increasing the observation length does not eliminate the error floor associated with the finite loop SNR. Nevertheless, in the limit of infinite observation length, the average error probability performance approaches the algebraic sum of the error floor and the performance of ideal coherent detection, i.e., at any error probability above the error floor, there is no degradation due to the partial coherence. It is shown that this limiting behavior is virtually achievable with practical size observation lengths. Furthermore, the performance is quite insensitive to mismatch between the estimate of loop SNR (e.g., obtained from measurement) fed to the decision metric and its true value. These results may be of use in low-cost Earth-orbiting or deep-space missions employing coded modulations.

Simon, M. K.↗

Ice sheet topography from retracked ERS-1 altimetry

An objective of the ERS-1 radar altimeter is to measure the surface topography of the polar ice sheets to a precision on the order of a meter. ERS-1 Waveform Altimeter Product (WAP) data was corrected for several processing errors. A range correction from the WAP waveforms, using the multiparameter retracking algorithm to account for range tracking limitations inherent to radar altimetry, was derived. From crossover analysis, the resulting precision is shown to be about 2.1 m in ocean mode and 2.2 m in ice mode. A topography map, produced with 23 days of corrected data, shows details of the western part of west Antarctic ice sheet and part of the Ross ice shelf including ice divides, ice stream boundaries, and ice shelf grounding lines.

Zwally, H. Jay↗

Evaluation of the TOPEX/POSEIDON altimeter system over the Great Lakes

The TOPEX/POSEIDON altimeter measurment system is evaluated for the first 46 repeat cycles (September 23, 1992-December 23, 1992) using tracks over the Great Lakes. The temporal variations in lake level are removed from the altimeter measurements using in-situ lake level measurements, thus permitting the performance of the altimeter system to be assessed. For the NASA altimeter, the root-mean-square (RMS) scatter of the residuals is 3.95 cm using all the tracks over the lakes. However, some of the scatter in this result is probably due to lake tides or seiche, which can amount to a few centimeters amplitude near the ends of the lakes. When the seven best tracks are used, which cross the center of the lakes where tides/seiche effects are minimal, the RMS error is included to either 2.9 or 3.0 cm, depending on whether the Centre National d'Etudes Spatiales (CNES) or NASA orbit is used. This places an upper limit on the error budget of the altimeter system, excluding ocean tides and inverse barometer effect. There are several short-period variations in the residuals. The most pronounced is a 55-day period, with a 1-cm amplitude, which we believe is (at least in part) due to orbit error. When the model-derived wet tropospheric correction is substituted for the TOPEX microwave radiometer correction, the RMS error increases significantly, possibly resulting in an annual cycle of a few centimeters. Evaluation of the ionospheric correction indicates that the dual-frequency correction provides an average improvement of 0.85 cm over the Doppler orbitography and radiopositioning integrated by satellite (DORIS) correction. Although there are insufficient data to directly assess the CNES altimeter, the relative bias between the altimeters is estimated to be either -14.3 or -15.6 cm (NASA altimeter measuring short), depending on whether the DORIS or dual-frequency ionospheric correction is applied to the NASA altimeter.

Morris, Charles S.↗

Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography

Previous studies have shown that small intraventricular pressure gradients (IVPG) are important for efficient filling of the left ventricle (LV) and as a sensitive marker for ischemia. Unfortunately, there has previously been no way of measuring these noninvasively, severely limiting their research and clinical utility. Color Doppler M-mode (CMM) echocardiography provides a spatiotemporal velocity distribution along the inflow tract throughout diastole, which we hypothesized would allow direct estimation of IVPG by using the Euler equation. Digital CMM images, obtained simultaneously with intracardiac pressure waveforms in six dogs, were processed by numerical differentiation for the Euler equation, then integrated to estimate IVPG and the total (left atrial to left ventricular apex) pressure drop. CMM-derived estimates agreed well with invasive measurements (IVPG: y = 0.87x + 0.22, r = 0.96, P < 0.001, standard error of the estimate = 0.35 mmHg). Quantitative processing of CMM data allows accurate estimation of IVPG and tracking of changes induced by beta-adrenergic stimulation. This novel approach provides unique information on LV filling dynamics in an entirely noninvasive way that has previously not been available for assessment of diastolic filling and function.

Non-NASA Center↗

Hurricane Forecasts with a Global Mesoscale-resolving Model on the NASA Columbia Supercomputer Preliminary Simulations of Hurricane Katrina (2005)

It is known that the General Circulation Models (GCMs) have sufficient resolution to accurately simulate hurricane near-eye structure and intensity. To overcome this limitation, the mesoscale-resolving finite-element GCM (fvGCM) has been experimentally deployed on the NASA Columbia supercomputer, and its performance is evaluated choosing hurricane Katrina as an example in this study. On late August 2005 Katrina underwent two stages of rapid intensification and became the sixth most intense hurricane in the Atlantic. Six 5-day simulations of Katrina at both 0.25 deg and 0.125 deg show comparable track forecasts, but the 0,125 deg runs provide much better intensity forecasts, producing center pressure with errors of only +/- 12 hPa. The 0.125 deg simulates better near-eye wind distributions and a more realistic average intensification rate. A convection parameterization (CP) is one of the major limitations in a GCM, the 0.125 deg run with CP disabled produces very encouraging results.

Shen, B.-W.↗

Programmable Oscillator

A programmable oscillator is a frequency synthesizer with an output phase that tracks an arbitrary function. An offset, phase-locked loop circuit is used in combination with an error control feedback loop to precisely control the output phase of the oscillator. To down-convert the received signal, several stages of mixing may be employed with the compensation for the time-base distortion of the carrier occurring at any one of those stages. In the Goldstone Solar System Radar (GSSR), the compensation occurs in the mixing from an intermediate frequency (IF), whose value is dependent on the station and band, to a common IF used in the final stage of down-conversion to baseband. The programmable oscillator (PO) is used in the final stage of down-conversion to generate the IF, along with a time-varying phase component that matches the time-base distortion of the carrier, thus removing it from the final down-converted signal.

Quirk, Kevin J.↗

Jason-1 and Jason-2 POD Using GPS

The Jason-2 satellite, launched in June 2008, is the latest follow-on to the successful Jason-1 altimetry satellite mission launched in December 7, 2001. Both, Jason-2 and Jason-1 are equipped with a GPS dual-frequency receiver, a laser retroreflector array, and a DORIS receiver for precise orbit determination (POD). A series of dynamic and reduced-dynamic Jason-2 orbits computed at NASA GSFC, based on GPS-only data and the std0905 standards, have been completed till cy74through cycle 74 using the IGS05 framework. These orbits, now publicly available, have been shown to agree radially at 1 cm RMS with the GSFC std0905 SLR/DORIS orbits and in comparison with orbits produced by JPL, ESA and CNES. In this paper, we describe the implementation of the IGS08 and repro1 framework for the Jason-2 and Jason-1 GPS POD processing with the NASA GSFC GEODYN software. . In our updated GPS POD, ambiguity fixing and updated time variable and static gravity fields. We also evaluate the implementation of non-tidal and degree-1 loading displacement as forward modeling to the tracking stations. Reduced-dynamic versus dynamic orbit differences are used to characterize the remaining force model errors and TRF instability. In particular, we assess their consistency radially and the stability of the altimeter satellite reference frame in the North/South direction as a proxy to assess the consistency of the reference frame.

Melachroinos, Stavros↗

Assessment of ICESat-2’s Horizontal Accuracy Using Precisely Surveyed Terrains in McMurdo Dry Valleys, Antarctica

This article presents an assessment of the horizontal accuracy and precision of the laser altimetry observations collected by NASA’s Ice, Cloud, and Land Elevation Satellite-2 (ICESat-2) mission. We selected the terrain-matching method to determine the position of laser altimeter profiles within a precisely known surface, represented by a digital elevation model (DEM). We took this classical approach a step further, approximated the DEM by planar surfaces, and calculated the optimal position of the laser profile by minimizing the square sum of the elevation differences between reference DEMs and ICESat-2 profiles. We found the highly accurate DEMs of the McMurdo Dry Valleys (DV), Antarctica, ideal for this research because of their stable landscape and rugged topography. We computed the 3-D shift parameters of 379 different laser altimeter profiles along two reference ground tracks collected within the first two years of the mission. Analyzing these results revealed a total geolocation error (mean +1 σ ) of 4.93 m for version 3 and 4.66 m for version 4 data. These numbers are the averages of the six beams, expressed as mean +1 σ and lie well within the mission requirement of 6.5 m.

calibration↗

On-line monitoring for turbine bypass system based on real-time simulation - 108

Faults may occur in nuclear power plants, but it is difficult for operators to recognize the situation and take effective measures quickly. However, on-line monitoring may help operators to detect the abnormalities so that the safety of nuclear power plants will be improved. As Turbine Bypass System runs during transient processes, quantitative simulation model is utilized for on-line monitoring. In addition, analyzing for residual errors of simulated and corresponding measured values are done by principle component analysis. Under normal operation, the methodology allows real-time tracking to set dynamic thresholds. While a failure occurs, faults can be detected. Simulation analysis show the effectiveness and accuracy of this methodology. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Are wide pre-main-sequence binaries coeval?

We have observed a sample of 39 wide (projected separations 400-6000 AU) pre-main-sequence binary pairs spectroscopically and with optical and near-infrared images. The observations enable us to place 26 of the pairs in an H-R diagram and to determine masses and ages of the primary and secondary according to three sets of pre-main-sequence evolutionary tracks. In two-thirds of the cases the primary and secondary lie along the same isochrone to within the observational errors. However, real age differences appear for about one-third of our sample pairs-there is no set of nonintersecting theoretical isochrones that can make the primary and secondary have the same age for all pairs in our sample. In the cases where there are significant age differences between the component stars, the less massive star is usually younger than the more massive star. There is no correlation of the age differences with the presence or absence of accretion disks around the young stars. Hence, while disk accretion may affect the evolutionary tracks of the pre-main-sequence stars H-R diagram, we see no clear evidence of this effect among the pairs in our sample. The age differences also do not depend systematically on the apparent separation, the mass ratio, or the ages of stars.

Hartigan, Patrick↗

A hybrid approach to estimate the complex motions of clouds in sky images

Tracking the motion of clouds is essential to forecasting the weather and to predicting the short-term solar energy generation. Existing techniques mainly fall into two categories: variational optical flow, and block matching. In this article, we summarize recent advances in estimating cloud motion using ground-based sky imagers and quantitatively evaluate state-of-the-art approaches. Then we propose a hybrid tracking framework to incorporate the strength of both block matching and optical flow models. To validate the accuracy of the proposed approach, we introduce a series of synthetic images to simulate the cloud movement and deformation, and thereafter comprehensively compare our hybrid approach with several representative tracking algorithms over both simulated and real images collected from various sites/imagers. The results show that our hybrid approach outperforms state-of-the-art models by reducing at least 30% motion estimation errors compared with the ground-truth motions in most of simulated image sequences. Furthermore, our hybrid model demonstrates its superior efficiency in several real cloud image datasets by lowering at least 15% Mean Absolute Error (MAE) between predicted images and ground-truth images.

54 ENVIRONMENTAL SCIENCES↗

A discussion of observation model, error sources and signal size for spaceborne gravitational gradiometry

Various space concepts were discussed during the past 20 years for a global improvement of the knowledge of the earth's gravity field. The concepts reach from high-low and low-low satellite-to-satellite tracking via tethered satellite gradiometers to sophisticated superconducting gradiometers. The purpose is to show that starting from one basic equation three criteria are sufficient to typify the various concepts and define the underlying observation model. Furthermore the different error sources, in particular, the time varying part of self-gravitation, and the expected signal size of all six gravity gradient components shall be discussed.

Rummel, R.↗

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

The identification of the variation of atherosclerosis plaques by invasive and non-invasive methods

Computer-enhanced visualization of coronary arteries and lesions within them is discussed, comparing invasive and noninvasive methods. Trial design factors in computer lesions assessment are briefly discussed, and the use of the computer edge-tracking technique in that assessment is described. The results of a small pilot study conducted on serial cineangiograms of men with premature atherosclerosis are presented. A canine study to determine the feasibility of quantifying atherosclerosis from intravenous carotid angiograms is discussed. Comparative error for arterial and venous injection in the canines is determined, and the mode of processing the films to achieve better visualization is described. The application of the computer edge-tracking technique to an ultrasound image of the human carotid artery is also shown and briefly discussed.

Selzer, R. H.↗

LightForce Photon-Pressure Collision Avoidance: Efficiency Assessment on an Entire Catalogue of Space Debris

The potential to perturb debris orbits using photon pressure from ground-based lasers has been confirmed by independent research teams. Two useful applications of this scheme are protecting space assets from impacts with debris and stabilizing the orbital debris environment, both relying on collision avoidance rather than de-orbiting debris. This paper presents the results of a new assessment method to analyze the efficiency of the concept for collision avoidance. Earlier research concluded that one ground based system consisting of a 10 kW class laser, directed by a 1.5 m telescope with adaptive optics, can prevent a significant fraction of debris-debris collisions in low Earth orbit. That research used in-track displacement to measure efficiency and restricted itself to an analysis of a limited number of objects. As orbit prediction error is dependent on debris object properties, a static displacement threshold should be complemented with another measure to assess the efficiency of the scheme. In this paper we present the results of an approach using probability of collision. Using a least-squares fitting method, we improve the quality of the original TLE catalogue in terms of state and co-state accuracy. We then calculate collision probabilities for all the objects in the catalogue. The conjunctions with the highest risk of collision are then engaged by a simulated network of laser ground stations. After those engagements, the perturbed orbits are used to re-assess the collision probability in a 20 minute window around the original conjunction. We then use different criteria to evaluate the utility of the laser-based collision avoidance scheme and assess the number of base-line ground stations needed to mitigate a significant number of high probability conjunctions. Finally, we also give an account how a laser ground station can be used for both orbit deflection and debris tracking.

laser↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transport of lunar material to the sites of the colonies

An 'existence proof' is attempted for the feasibility of transport of lunar material to colonies in space. Masses of lunar material are accelerated to lunar escape by a tracked magnetically levitated mass driver; aim precision is to 1 km miss distance at L5 per mm/sec velocity error at the lunar surface. Mass driver design and linear synchronous motor drive design are discussed; laser-sensed checkpoints aid in velocity and directional precision. Moon-L5 trajectories are calculated. The design of the L5 construction station, or 'catcher vehicle,' is described; loads are received by chambers operating in a 'Venus flytrap' mode. Further research studies needed to round out the concept are listed explicitly.

Heppenheimer, T. A.↗