Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Measurements of the thermal plasma environment of the Space Shuttle

The paper presents some initial results on measurements of the thermal plasma environment obtained by a spherical retarding potential analyzer and a Langmuir probe flown on (STS-3) as part of the NASA Office of Space Science-1 payload in March 1982. One of the major effects observed is a higher degree of turbulence in the ambient plasma compared to what is observed from similar instruments flown on unmanned satellites. In addition we see the temperature of the thermal electrons elevated to values of 4000-5000 K. Associated with elevated electron temperatures are regions of enhanced plasma density resulting from the appearance of high densities of molecular ions. The thermal plasma data also show clear effects of an induced V x B.L potential at the location of the probes which matches that produced by an L vector linking the probes to the engine nozzles; thereby establishing the prime return current location on the Orbiter. The final observations discussed are the pronounced and complex wake effects resulting both from the main structure of the Orbiter and from the complex shapes of appendages attached to the Orbiter.

Raitt, W. J.↗

TIA Software User's Manual

This user's manual describes the installation and operation of TIA, the Thermal-Imaging acquisition and processing Application, developed by the Nondestructive Evaluation Sciences Branch at NASA Langley Research Center, Hampton, Virginia. TIA is a user friendly graphical interface application for the Macintosh 2 and higher series computers. The software has been developed to interface with the Perceptics/Westinghouse Pixelpipe(TM) and PixelStore(TM) NuBus cards and the GW Instruments MacADIOS(TM) input-output (I/O) card for the Macintosh for imaging thermal data. The software is also capable of performing generic image-processing functions.

Cramer, K. Elliott↗

Micro-Vibration Measurements on Thermally Loaded Multi-Layer Insulation Samples in Vacuum

Some scientific missions require to an extreme extent the absence of any on-board microvibration. Recent projects dedicated to measuring the Earth's gravity field and modeling the geoid with extremely high accuracy are examples. Their missions demand for extremely low micro-vibration environment on orbit for: (1) Not disturbing the measurement of earth gravity effects with the installed gradiometer or (2) Even not damaging the very high sensitive instruments. Based on evidence from ongoing missions multi-layer insulation (MLI) type thermal control blankets have been identified as a structural element of spacecrafts which might deform under temperature variations being caused by varying solar irradiation in orbit. Any such deformation exerts tiny forces which may cause small reactions resulting in micro-vibrations, in particular by exciting the spacecraft eigenmodes. The principle of the test set-up for the micro-vibration test was as follows. A real side wall panel of the spacecraft (size about 0.25 m2) was low-frequency suspended in a thermal vacuum chamber. On the one side of this panel, the MLI samples were fixed by using the standard methods. In front of the MLI, an IR-rig was installed which provided actively controlled IR-radiation power of about 6 kW/m2 in order to heat the MLI surface. The cooling was passive using the shroud temperature at a chamber pressure <1E-5mbar. The resulting micro-vibrations due to MLI motion in the heating and the cooling phase were measured via seismic accelerometers which were rigidly mounted to the panel. Video recording was used to correlate micro-vibration events to any visual MLI motion. Different MLI sample types were subjected to various thermal cycles in a temperature range between -60 C to +80 C. In this paper, the experience on these micro-vibration measurements will be presented and the conclusions for future applications will be discussed

Deutsch, Georg↗

Computational Fluid Dynamics (CFD) Analysis Of Optical Payload For Lasercomm Science (OPALS) sealed enclosure module

Computational Fluid Dynamics (CFD) using the commercial CFD package CFDesign has been performed at NASA Jet Propulsion Laboratory (JPL) California Institute of Technology (Caltech) in support of the Phaeton Early Career Hire Program's Optical Payload for Lasercomm Science (OPALS) mission. The OPALS project is one which involves an International Space Station payload that will be using forced convection cooling in a hermetically sealed enclosure at 1 atm of air to cool "off-the-shelf" vendor electronics. The CFD analysis was used to characterize the thermal and fluid flow environment within a complicated labyrinth of electronics boards, fans, instrumentation, harnessing, ductwork and heat exchanger fins. The paradigm of iteratively using CAD/CAE tools and CFD was followed in order to determine the optimum flow geometry and heat sink configuration to yield operational convective film coefficients and temperature survivability limits for the electronics payload. Results from this current CFD analysis and correlation of the CFD model against thermal test data will be presented. Lessons learned and coupled thermal / flow modeling strategies will be shared in this paper.

Computational Fluid Dynamics (CFD)↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Improved Blackbody Temperature Sensors for a Vacuum Furnace

Some improvements have been made in the design and fabrication of blackbody sensors (BBSs) used to measure the temperature of a heater core in a vacuum furnace. Each BBS consists of a ring of thermally conductive, high-melting-temperature material with two tantalum-sheathed thermocouples attached at diametrically opposite points. The name "blackbody sensor" reflects the basic principle of operation. Heat is transferred between the ring and the furnace heater core primarily by blackbody radiation, heat is conducted through the ring to the thermocouples, and the temperature of the ring (and, hence, the temperature of the heater core) is measured by use of the thermocouples. Two main requirements have guided the development of these BBSs: (1) The rings should have as high an emissivity as possible in order to maximize the heat-transfer rate and thereby maximize temperature-monitoring performance and (2) the thermocouples must be joined to the rings in such a way as to ensure long-term, reliable intimate thermal contact. The problem of fabricating a BBS to satisfy these requirements is complicated by an application-specific prohibition against overheating and thereby damaging nearby instrumentation leads through the use of conventional furnace brazing or any other technique that involves heating the entire BBS and its surroundings. The problem is further complicated by another application-specific prohibition against damaging the thin tantalum thermocouple sheaths through the use of conventional welding to join the thermocouples to the ring. The first BBS rings were made of graphite. The tantalum-sheathed thermocouples were attached to the graphite rings by use of high-temperature graphite cements. The ring/thermocouple bonds thus formed were found to be weak and unreliable, and so graphite rings and graphite cements were abandoned. Now, each BBS ring is made from one of two materials: either tantalum or a molybdenum/titanium/zirconium alloy. The tantalum-sheathed thermocouples are bonded to the ring by laser brazing. The primary advantage of laser brazing over furnace brazing is that in laser brazing, it is possible to form a brazed connection locally, without heating nearby parts to the flow temperature of the brazing material. Hence, it is possible to comply with the prohibition against overheating nearby instrumentation leads. Also, in laser brazing, unlike in furnace brazing, it is possible to exert control over the thermal energy to such a high degree that it becomes possible to braze the thermocouples to the ring without burning through the thin tantalum sheaths on the thermocouples. The brazing material used in the laser brazing process is a titanium-boron paste. This brazing material can withstand use at temperatures up to about 1,400 C. In thermal-cycling tests performed thus far, no debonding between the rings and thermocouples has been observed. Emissivity coatings about 0.001 in. (.0.025 mm) thick applied to the interior surfaces of the rings have been found to improve the performance of the BBS sensors by raising the apparent emissivities of the rings. In thermal-cycling tests, the coatings were found to adhere well to the rings.

Farmer, Jeff↗

Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System

As shown by the Phoenix Mars Lander's Thermal and Electrical Conductivity Probe (TECP), contact measurements of thermal conductivity and diffusivity (using a modified flux-plate or line-source heat-pulse method) are constrained by a number of factors. Robotic resources must be used to place the probe, making them unavailable for other operations for the duration of the measurement. The range of placement is also limited by mobility, particularly in the case of a lander. Placement is also subject to irregularities in contact quality, resulting in non-repeatable heat transfer to the material under test. Most important from a scientific perspective, the varieties of materials which can be measured are limited to unconsolidated or weakly-cohesive regolith materials, rocks, and ices being too hard for nominal insertion strengths. Accurately measuring thermal properties in the laboratory requires significant experimental finesse, involving sample preparation, controlled and repeatable procedures, and, practically, instrumentation much more voluminous than the sample being tested (heater plates, insulation, temperature sensors). Remote measurements (infrared images from orbiting spacecraft) can reveal composite properties like thermal inertia, but suffer both from a large footprint (low spatial resolution) and convolution of the thermal properties of a potentially layered medium. In situ measurement techniques (the Phoenix TECP is the only robotic measurement of thermal properties to date) suffer from problems of placement range, placement quality, occupation of robotic resources, and the ability to only measure materials of low mechanical strength. A spacecraft needs the ability to perform a non-contact thermal properties measurement in situ. Essential components include low power consumption, leveraging of existing or highly-developed flight technologies, and mechanical simplicity. This new in situ method, by virtue of its being non-contact, bypasses all of these problems. The use of photons to both excite and measure the thermal response of any surface material to a high resolution (estimated footprint = 10 square centimeters) is a generational leap in physical properties measurements. The proposed method consists of spot-heating the surface of a material with a low (less than 1 W) power laser. This produces a moderate (5-10 K) temperature increase in the material.

Hudson, Troy L.↗

Uses of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.

Source record↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Evaluation of Aqua MODIS and S-NPP VIIRS Thermal Emissive Bands Calibration Stability Using Dome-C

Establishing the calibration consistency between satellite measurements is an essential step in the implementation of a long-term global monitoring plan, which often leads to sensor calibration improvements. The Suomi National Polar-Orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) is a polar-orbiting Earth remote sensing instrument built with a strong Moderate Resolution Imaging Spectroradiometer (MODIS) heritage. The center wavelengths of all VIIRS thermal emissive bands (TEBs) match well with those of MODIS with the exception of VIIRS TEB M15 (10.7μm). Previous work from the MODIS Characterization Support Team (MCST) at the NASA/GSFC used specific Earth surface targets to track the long-term consistency,stability, and relative bias between the two MODIS instruments onboard the Terra and Aqua satellites. Using similar methodologies, this paper evaluates the TEB calibration consistency between the MODIS instruments and S-NPP VIIRS over Dome Concordia (Dome-C). The Dome-C site is uniformly snow-covered and the atmospheric effects are small in the surrounding area. Near-surface air temperature measurements from an Automatic Weather Station (AWS) are used as a reference to track each sensor’s calibration stability and determine the relative bias between the MODIS and VIIRS instruments. The results of this study provide a quantitative assessment of the S-NPP VIIRS TEB mission-long performance.

MODIS↗

Mechanical cooler-to-Dewar interfacing in a long-lifetime, hybrid stored cryogen system

The means for making efficient use of mechanical coolers to limit the parasitic heating into the Dewar are addressed. Thermal efficiency is achieved by minimizing the parasitic heating and thermal impedance of the cooler-to-Dewar interface within the mechanical constraints. The important issues related to compatibility with the instrument system are also briefly discussed. Parasitic heating from the nonoperating (reserved or failed) cooler pair can be reduced with an active thermal switch that isolates the cooler cold tips from the cold finger. An analysis was performed to determine the optimal switch-operating characteristics for this application. Requirements associated with the use of the coolers, analyses performed, and the interface design concept are discussed.

Hopkins, R. A.↗

Experimental results of Hooper's gravity-electromagnetic coupling concept

Experiments were conducted to test assertions from Patent 3,610,971, by W.J. Hooper that self-canceling electromagnetic coils can reduce the weight of objects placed underneath. No weight changes were observed within the detectability of the instrumentation. More careful examination of the patent and other reports from Hooper led to the conclusion that Hooper may have misinterpreted thermal effects as his 'Motional Field' effects. There is a possibility that the claimed effects are below the detection thresholds of the instrumentation used for these tests.

Millis, Marc G.↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

Recent Results From The Nasa Earth Science Terra Mission and Future Possibilities

The NASA Earth Sciences Enterprise has made some remarkable strides in recent times in using developing, implementing, and utilizing spaceborne observations to better understand how the Earth works as a coupled, interactive system of the land, ocean, and atmosphere. Notable examples include the Upper Atmosphere Research (UARS) Satellite, the Topology Ocean Experiment (TOPEX) mission, Landsat-7, SeaWiFS, the Tropical Rainfall Monitoring Mission (TRMM), Quickscatt, the Shuttle Radar Topography Mission (SRTM), and, quite recently, the Terra'/Earth Observing System-1 mission. The Terra mission, for example, represents a major step forward in providing sensors that offer considerable advantages and progress over heritage instruments. The Moderate Resolution Imaging Spectrometer (MODIS), the Multi-angle Imaging SpectroRadiometer (MISR), the Measurements of Pollution in the Troposphere (MOPITT), the Advanced Spaceborne Thermal Emissions and Reflections (ASTER) radiometer, and the Clouds and Earth's Radiant Energy System (CERES) radiometer are the instruments involved. Early indications in March indicate that each of these instruments are working well and will be augmenting data bases from heritage instruments as well as producing new, unprecedented observations of land, ocean, and atmosphere features. Several missions will follow the Terra mission as the Earth Observing mission systems complete development and go into operation. These missions include EOS PM-1/'Aqua', Icesat, Vegetation Canopy Lidar (VCL), Jason/TOPEX Follow-on, the Chemistry mission, etc. As the Earth Observing systems completes its first phase in about 2004 a wealth of data enabling better understanding of the Earth and the management of its resources will have been provided. Considerable thought is beginning to be placed on what advances in technology can be implemented that will enable further advances in the early part of the 21st century; e.g., in the time from of 2020. Concepts such as 'constellation' missions or 'formation flying' with 'sensorcraft', 'sensor webs', autonomous operation of satellites, more on-board processing and delivery to individual users, data synthesis and analysis in real-time, etc. are being considered. With the data now having been and soon to be received plus the very real possibilities of further advances in use and applicability of data the potential for very significant gains in knowledge for Earth studies and applications looks quite high in the next decade or two.

Salomonson, Vincent V.↗

Landsat Instrument Suite (LandIS) Sensor Design for the Landsat 10 Mission

Landsat 10 will be the upcoming mission in the 50+ year Landsat series of Earth observation platforms. The centerpiece of the observatory will be a super-spectral imager known as the Landsat Instrument Suite (LandIS). The sensor will feature 26 spectral channels from the visible through near-, short-wave, and thermal infrared wavelengths with spatial resolutions of 10, 20, and 60 meters on the ground, depending on the band. These enhancements over the legacy Landsat instruments will ensure data continuity with the existing archive and will expand upon the core Landsat capabilities to enable new applications in Earth science. After a competitive procurement, NASA selected the design submitted by the Raytheon Company for the LandIS instrument. The innovative Raytheon instrument concept utilizes an advanced whiskbroom architecture to fulfill the strict radiometric, spatial, and geometric image quality requirements demanded by the Landsat 10 mission and fits within restrictive mass, volume, and power constraints. The instrument will continue the Landsat directive to image all daylit land and near-shore water areas, along with select nighttime imaging. On-board calibration source data will ensure high radiometric and geometric accuracy and stability consistent with previous missions to enable continuity in data products available to users. This paper discusses the driving requirements for LandIS and provides a description of the chosen design and operations concept of the instrument.

Requirements↗

AGC 4 Graphite Specimen Postirradiation Characterization Plan

This characterization plan describes the thermal, physical, and mechanical measurement techniques that will be used to characterize graphite samples being tested in the fourth Advanced Graphite Creep experiment (AGC-4). Instruments, fixtures, and methods are currently in place for both pre and postirradiation material property measurements of bulk density, thermal diffusivity, coefficient of thermal expansion, elastic modulus, and electrical resistivity. Postirradiation testing procedures used to characterize the samples are described and discussed in the plan. Where they exist, American Society for Testing and Materials (ASTM) International testing standards will apply to the tests. Any departure from ASTM International testing standards or the approved laboratory procedures are documented within this characterization plan. Deviations that occur during testing will be documented in data reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗