Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Holographic grating relaxation technique for soft matter science

The holographic grating relaxation technique also known as forced Rayleigh scattering consists basically in writing a holographic grating in the specimen of interest and monitoring its diffraction efficiency as a function of time, from which valuable information on mass or heat transfer and photoinduced transformations can be extracted. In a more detailed view, the shape of the relaxation curve and the relaxation rate as a function of the grating period were found to be affected by the architecture of diffusing species (molecular probes) that constitute the grating, as well as that of the environment they diffuse in, thus making it possible to access and study spatial heterogeneity of materials and different modes of e.g., polymer motion. Minimum displacements and spatial domains approachable by the technique are in nanometer range, well below spatial periods of holographic gratings. In the present paper, several cases of holographic relaxation in heterogeneous media and complex motions are exemplified. Nano- to micro-structures or inhomogeneities comparable in spatial scale with holographic gratings manifest themselves in relaxation experiments via non-exponential decay (stepwise or stretched), spatial-period-dependent apparent diffusion coefficient, or unusual dependence of diffusion coefficient on molecular volume of diffusing probes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of elongated bubbles fusing the information from multiple optical probes through a Bayesian inference technique

In this communication, a novel optical technique has been proposed for the reconstruction of the shape of a Taylor bubble using measurements from multiple arrays of optical sensors. The deviation of an optical beam passing through the bubble depends on the contour of bubble surface. A theoretical model of the deviation of a beam during the traverse of a Taylor bubble through it has been developed. Using this model and the time history of the deviation captured by the sensor array, the bubble shape has been reconstructed. The reconstruction has been performed using an inverse algorithm based on Bayesian inference technique and Markov chain Monte Carlo sampling algorithm. The reconstructed nose shape has been compared with the true shape, extracted through image processing of high speed images. Finally, an error analysis has been performed to pinpoint the sources of the errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technique for the comparison of light spectra from natural and laboratory generated lightning current arcs

A technique was developed for the comparison of observed emission spectra from lightning current arcs generated through self-breakdown in air and the use of two types of initiation wire, aluminum bronze and nichrome, against previously published spectra of natural lightning events. A spectrograph system was used in which the wavelength of light emitted by the lightning arc was analyzed to derive elemental interactions. A lightning impulse of up to 100 kA was applied to a two hemispherical tungsten electrode configuration which allowed the effect of the lightning current and lightning arc length to be investigated. A natural lightning reference spectrum was reconstructed from literature, and generated lightning spectra were obtained from self-breakdown across a 14.0 mm air gap and triggered along initiation wires of length up to 72.4 mm. A comparison of the spectra showed that the generated lightning arc induced via self-breakdown produced a very similar spectrum to that of natural lightning, with the addition of only a few lines from the tungsten electrodes. A comparison of the results from the aluminum bronze initiation wire showed several more lines, whereas results from the nichrome initiation wire differed greatly across large parts of the spectrum. This work highlights the potential use for spectrographic techniques in the study of lightning interactions with surrounding media and materials, and in natural phenomena such as recently observed ball lightning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonequilibrium diagrammatic technique for Hubbard Green functions

Here, we introduce diagrammatic technique for Hubbard nonequilibrium Green functions. The formulation is an extension of equilibrium considerations for strongly correlated lattice models to description of current carrying molecular junctions. Within the technique intra-system interactions are taken into account exactly, while molecular coupling to contacts is used as a small parameter in perturbative expansion. We demonstrate the viability of the approach with numerical simulations for a generic junction model of quantum dot coupled to two electron reservoirs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using reduced density matrix techniques to capture static and dynamic correlation in the energy landscape for the decomposition of the CH 2 CH 2 ONO radical and support a non-IRC pathway

The unexpected abundance of HNO in the photodecomposition of the radical 2-nitrosooxy ethyl (CH 2 CH 2 ONO) is investigated through calculations of the potential energy surface by the anti-Hermitian contracted Schrödinger equation (ACSE) approach, which directly generates the 2-electron reduced density matrix. The ACSE, which is able to balance single-reference (dynamic) and multi-reference (static) correlation effects, reveals some subtle correlation effects along the intrinsic reaction coordinate (IRC) en route to NO + oxirane, an IRC which offers a potential bifurcation to the HNO + vinoxy product channel. Here, these effects were not fully captured by either single-reference techniques, such as coupled cluster, or multi-reference techniques, such as second-order multi-reference perturbation theory. These correlation effects reveal small to moderate energy changes in key transition states, which have implications for the reaction mechanism as related to the production of HNO.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing deceleration-phase instabilities in inertial confinement fusion implosions using an “enhanced self-emission” technique at the National Ignition Facility

High-mode perturbations and low-mode asymmetries were measured in the deceleration phase of indirectly-driven, deuterium gas filled inertial confinement fusion (ICF) capsule implosions at convergence ratios of 10 to 15, using a new “enhanced emission” technique at the National Ignition Facility (NIF) [E. M. Campbell, R. Cauble, and B. A. Remington, AIP Conf. Proc. 429, 3 (1998)]. In these experiments, a high spatial resolution Kirkpatrick-Baez microscope was used to image the x-ray emission from the inner surface of a high-density-carbon (HDC) capsule’s shell. Use of a high atomic number dopant in the shell enabled time-resolved observations of shell perturbations penetrating into the hot spot. This allowed the effects of the perturbations and asymmetries on degrading neutron yield to be directly measured. In particular, mix induced radiation losses of ~400 J from the hot spot resulted in a neutron yield reduction of a factor of ~2. In a subsequent experiment with a significantly increased level of short-mode initial perturbations, shown through the enhanced imaging technique to be highly organized radially, the neutron yield dropped an additional factor of ~2.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of the foil-on-hohlraum technique for the magnetic recoil spectrometer for time-resolved neutron measurements at the National Ignition Facility

The next-generation Magnetic Recoil Spectrometer, called MRSt, will provide time-resolved measurements of the deuterium-tritium-neutron spectrum from inertial confinement fusion implosions at the National Ignition Facility. These measurements will provide critical information about the time evolution of the fuel assembly, hot-spot formation, and nuclear burn. The absolute neutron spectrum in the energy range of 12-16 MeV will be measured with high accuracy (~5%), unprecedented energy resolution (~100 keV) and, for the first time ever, time resolution (~20 ps). Crucial to the design of the system is a CD conversion foil for the production of recoil deuterons positioned as close to the implosion as possible. The foil-on-hohlraum technique has been demonstrated by placing a 1-mm-diameter, 40-μm-thick CD foil on the hohlraum diagnostic band along the line-of-sight of the current time-integrated MRS system, which measured the recoil deuterons. In addition to providing validation of the foil-on-hohlraum technique for the MRSt design, substantial improvement of the MRS energy resolution was demonstrated.

42 ENGINEERING↗

Use of a non-collinear wave mixing technique to image internal microscale damage in concrete

This research demonstrates the feasibility of using a non-collinear wave mixing technique to image internal microscale damage throughout the interior volume of a relatively large (28 cm thick) concrete component. By exploiting the underlying mechanics of nonlinear wave mixing, it is possible to mix two incident waves with frequencies low enough to propagate without being scattered by the inherently heterogenous, concrete microstructure, while still being sensitive to damage features with length scales well below these incident wavelengths. For this study, scanning and imaging is accomplished by manually adjusting the locations of the two incident waves, while a knowledge of the wave speeds in concrete plus synchronization identifies the location of the mixing zone—the specific volume of concrete being imaged. The viability of the proposed technique is demonstrated by examining a concrete prism specimen with known, embedded internal microscale damage.

Kim, Jin-Yeon (ORCID:0000000255180032)↗

Machine learning-aided line intensity ratio technique applied to deuterium plasmas

It has been demonstrated that the electron density, n e , and temperature, T e , are successfully evaluated from He I line intensity ratios coupled with machine learning (ML). In this paper, the ML-aided line intensity ratio technique is applied to deuterium (D) plasmas with 0.031 < n e (10 18 m –3 ) < 0.67 and 2.3 < T e (eV) < 5.1 in the PISCES-A linear plasma device. Two line intensity ratios, D α /D γ and D α /D β , are used to develop a predictive model for n e and T e separately. Reasonable agreement of both ne and Te with those from single Langmuir probe measurements is obtained at n e > 0.1 × 10 18 m –3 . Addition of the D 2 /D α intensity ratio, where the D 2 band emission intensity is integrated in a wavelength range of λ ~ 557.4–643.0 nm, is found to improve the prediction of, in particular, n e , and T e . It is also confirmed that the technique works for D plasmas with 0.067 < n e (10 18 m –3 ) < 6.1 and 0.8 < T e (eV) < 15 in another linear plasma device, PISCES-RF. The two training datasets from PISCES-A and PISCES-RF are combined, and unified predictive models for n e and T e give reasonable agreement with probe measurements in both devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics↗

Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technique of pulsed optical pumping and pulsed excitation of microwave resonances using the Ramsey scheme in a {sup 87}Rb cell with a buffer gas

A laboratory prototype of a compact quantum frequency standard based on a rubidium vapour cell with pulsed laser pumping is developed. With significantly smaller overall dimensions (a volume of ∼10 L and a mass of ∼10 kg), the frequency standard is expected to have the short-term instability comparable with that of the commercial passive hydrogen masers and even the laboratory fountain-type atomic clocks based on cold atoms. The advantages of the technique of pulsed optical pumping and pulsed excitation of microwave resonances over the traditional techniques of double radio-optical resonance detection are substantiated. The results of the experimental study of pulsed optical pumping of a rubidium cell with a mixture of buffer Ar – Ne gases implemented at the VNIIFTRI are presented, the Ramsey resonances are obtained, and the process of optimising the contrast of the central resonance peak is described. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative analysis of 2D spatio-temporal visualisation techniques for the pulsed THz-radiation field using an electro-optic crystal

Two 2D techniques for visualising the field of pulsed THz radiation (‘shadow’ and ‘interferometric’), which are based on the linear electro-optical effect with application of a ZnTe detector crystal 1 × 1 cm in size, are compared. The noise level and dynamic range for the aforementioned techniques are analysed and their applicability limits are discussed. (thz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent research on inherent molecular structure, physiochemical properties, and bio-functions of food and feed-type Avena sativa oats and processing-induced changes revealed with molecular microspectroscopic techniques

Avena sativa oat is a cereal widely used as human food and livestock feed. However, the low metabolized energy and the rapid rumen degradations of protein and starch have limited the use of A. sativa oat grains. To overcome this disadvantage, new A. sativa oat varieties have been developed. Additionally, heat-related processing has been performed to decrease the degradation rate and improve the absorption of amino acids in the small intestine. The nutritive value is reflected by both chemical composition and inherent molecular structure conformation. However, the traditional wet chemical analysis is not able to detect the inherent molecular structures within an intact tissue. The advanced synchrotron-radiation and globar-based molecular microspectroscopy have been developed recently and applied to study internal molecular structures and the processing induced structure changes in A. sativa oats and reveal how molecular structure changes in relation to nutrient availability. This review aimed to obtain the recent information regarding physiochemical properties, molecular structures, metabolic characteristics of protein, and the heat-induced changes in new A. sativa oat varieties. The use of the advanced vibrational molecular spectroscopy was emphasized, synchrotron- and globar-based (micro)spectroscopy, to reveal the inherent structure of A. sativa oats at cellular and molecular levels and to reveal the heat processing effect on the degradation characteristics and the protein molecular structure in A. sativa oats. The relationship between nutrient availability and protein molecular inherent structure was also presented. Information described in this review gives better insight in the physiochemical properties, molecular structure, and the heat-induced changes in A. sativa oat detected with advanced molecular spectroscopic techniques in combinination with conventional nutrition study techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GeoAI: spatially explicit artificial intelligence techniques for geographic knowledge discovery and beyond

Recent progress in Artificial Intelligence (AI) techniques, the large-scale availability of high-quality data, as well as advances in both hardware and software to efficiently process these data, are transforming a range of fields from computer vision and natural language processing to autonomous driving and healthcare. For example, the availability of high-resolution geographic data and high-performance computing techniques together with deep learning fuel progress in fast and accurate object detection. Recent examples of GeoAI work include the detections of terrain features and densely-distributed building footprints, information extraction from scanned historical maps, semantic classification (e.g. LiDAR point clouds), novel methods for spatial interpolation, and advances in traffic forecasting. Similarly, machine learning and natural language processing are facilitating the extraction of geographic information from unstructured (textual) data, such as news articles and Wikipedia as well as the matching of natural features in multiple gazetteers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Elemental Characterization of Neutron-Irradiated Tungsten Using the GD-OES Technique

In reactor-relevant fusion divertor conditions, tungsten (W) will be used as an armor material due to its excellent thermal properties. It will be exposed to impurities from numerous sources, including ion implantation and mixing, neutron transmutation, low-Z plasma-facing-component (PFC) redeposition and codeposition of deuterium and tritium fuel, and trapped helium bubbles. The impurity plasma material–interaction effects are a concern because they can cause gradual degradation of the material and of plasma performance due to dust formation, fuel retention, and even changes to the thermal and mechanical properties of the W armor. It is crucial to measure the amount of impurities in W, and the glow discharge–optical emission spectroscopy (GD-OES) technique is exceptionally well suited for analysis of irradiated samples. GD-OES can measure a sample’s elemental composition by sputtering the surface of the sample, ionizing the eroded material, and measuring the optical emission of the excited atoms. In order for the GD-OES technique to be applied to neutron-irradiated tungsten samples, a mounting system for miniature samples was designed. The sample mounting and centering procedure was successful in measuring the depth distribution of control W and W alloy sample elemental concentrations. These control depth spectra will be used as elemental references for postirradiated samples. The residence time of surface layers was measured, a comparison of signals from different anodes was completed, and the influence of initial surface roughness or nonuniformity was understood. The depth distribution of an arc-welded W-0.4% rhenium (Re) alloy was measured to have a stable Re signal that was distributed evenly in the W matrix. Here, the methods developed here will allow for quantification of impurities and transmutation amounts in neutron-irradiated W. GD-OES is a powerful tool but requires calibration and careful optimization of the parameters to obtain meaningful results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗