Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reflectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Reflection type skin friction meter

A housing block is provided having an upper surface conforming to the test surface of a model or aircraft. An oil film is supplied upstream of a transparent wedge window located in this upper surface by an oil pump system located external to the housing block. A light source located within the housing block supplies a light beam which passes through this transparent window and is reflected back through the transparent window by the upper surface of the oil film to a photo-sensitive position sensor located within the housing. This position sensor allows the slope history of the oil film caused by and aerodynamic flow to be determined. The skin friction is determined from this slope history. Internally located mirrors augment and sensitize the reflected beam as necessary before reaching the position sensor. In addition, a filter may be provided before this sensor to filter the beam.

Bandyopadhyay, Promode R.↗

Fiber optic microphone having a pressure sensing reflective membrane and a voltage source for calibration purpose

A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a back plate for damping membrane motion. The back plate further provides a means for on-line calibration of the microphone.

Zuckerwar, Allan J.↗

Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.

Cromwell, B. K.↗

Angle-dependent Green's functions for relativistic Compton reflection

Using analytic methods, we derived the first-order Green's functions, in terms of the observing angle, for the reflected spectra after a single Compton scattering of relativistic photons by a plane-parallel semiinfinite medium of cold electrons. We also calculated the total Green's functions for incident photons of 511 keV, using Monte Carlo methods. We show that both the first-order and total Green's functions have strong angular dependences and that the first-order Green's functions play a dominant role in determining the properties of the total reflected spectra.

Hua, Xin-Min↗

Prairie grassland bidirectional reflectances measured by different instruments at the FIFE site

Land surface reflectance measurements were obtained during the First ISLSCP Field Experiment (FIFE) field campaigns utilizing a variety of airborne and ground-based spectral radiometers. To study the validity of the assumption that the values obtained by the several different teams and instruments were interchangeable, the surface radiation measurement teams converged on a common site for one day during the fifth intensive field campaign in 1989. The bidirectional reflectances from the various instruments were basically found to be comparable.

Deering, D. W.↗

Biophysical properties affecting vegetative canopy reflectance and absorbed photosynthetically active radiation at the FIFE site

Leaves of the dominant grass species of the ISCLP FIFE site reflect and transmit radiation in a like manner to other healthy green leaves. Visible reflectance factors (RFs) and transmittance factors (TFs) were less for older leaves than younger leaves except during senescence, when RF and TF values were greater. NIR-RF values increased and TF values decreased with leaf age, with the reverse occurring as the leaf went through senescence.

Walter-Shea, E. A.↗

Reflectance stability analysis of Spectralon diffuse calibration panels

The Multi-angle Imaging SpectroRadiometer (MISR) plans to use deployable diffuse reflectance panels to provide periodic radiometric calibrations of its nine cameras while in-flight. Near-Lambertian reflectance characteristics are desirable to facilitate flat-field camera intercomparisons. Also required is panel spatial and spectral uniformity, and stability with time. Spectralon, a commercially available polytetrafluoroethylene (PTFE) compound, has been baselined in the MISR design. To assess the suitability of this material, a series of degradation tests were planned and implemented. These included UV vacuum exposure and proton bombardment tests which simulated the exposure levels to be encountered during the mission life. Proton levels are now considered too low to be of concern, but UV vacuum tests demonstrate sensitivity to material contamination. Material investigations have concluded that hydrocarbons are present in the bulk of the material, and that plastic packaging materials can introduce additional surface-layer contamination. It is found however, that these unwanted elements can be eliminated through vacuum pumping at elevated temperatures. Exposure to a UV source, while in vacuum, is again planned for a set of targets which have been vacuum baked. This will assess the stability of the pure PTFE form.

Bruegge, Carol J.↗

Clouds as calibration targets for AVHRR reflected-solar channels - Results from a two-year study at NOAA/NESDIS

NOAA-11 Advanced Very High Resolution Radiometer (AVHRR) and associated ground-based data have been collected at NOAA/NESDIS, on a daily basis and for 600 days, using five stations within the continental United States in the NOAA solar radiation (SOLRAD) monitoring network. The data have been filtered to include only uniformly overcast conditions and analyzed along the lines described by Paris and Justus (1988). Results from this first long-term pilot operational application of the method are presented. The method is potentially useful for establishing yearly-averaged trends in the radiometric gain of AVHRR Channels. The relatively small data base examined here suggests a precision in the 600 day mean gain of 5 percent or worse, with a significant part of this uncertainty being driven by poor knowlege of the bidirectional reflectance properties of clouds. The results suggest that the method in its present formulation has insufficient precision to be used as a primary method for the measurement of in-orbit gains of reflected-solar radiometers aboard polar orbiting satellites. Intrinsic limitations to the precision and time resolution of the method are discussed, and suggestions are offered for improving the precision of future results.

Abel, Peter↗

General probability-matched relations between radar reflectivity and rain rate

An improved method for transforming radar-observed reflectivities Ze into rain rate R is presented. The method is based on a formulation of a Ze-R function constrained such that (1) the radar-retrieved pdf of R and all of its moments are identical to those determined from the gauges over a sufficiently large domain, and (2) the fraction of the time that it is raining above a low but still has an accurately measurable rain intensity is identical for both the radar and for simultaneous measurements of collocated gauges on average. Data measured by a 1.65-deg beamwidth C-band radar and 22 gauges located in the vicinity of Darwin, Australia, are used. The resultant Ze-R functions show a strong range dependence, especially for the rain regimes characterized by strong reflectivity gradients and substantial attenuation. The application of these novel Ze-R functions to the radar data produces excellent matches to the gauge measurements without any systematic bias.

Rosenfeld, Daniel↗

Heating of solar coronal holes by reflected Alfven waves

As a continuation of the work of Moore et al. (1991), who found evidence that coronal holes are heated by Alfven waves that are reflected back down within the coronal holes, this paper shows that to demonstrate this evidence, it is only necessary to consider a subset of the Moore et al. models, namely, those having radial magnetic field. Using these models, it is shown that the Alfven velocity is not constant in the atmosphere of coronal holes, but changes with height (or radius), causing downward reflection of all upward Alfven waves of sufficiently long wavelength (or period).

Moore, R. L.↗

Calibration of the AVHRR visible and near-IR bands by atmospheric scattering, ocean glint and desert reflection

A method for calibrating satellite sensors (such as the AVHRR visible and NIR bands) is proposed by which the sensors are calibrated using well-known physical characteristics of the atmosphere, ocean, and deserts, as well as the digital satellite imagery. The approach, independent of ground support, used the following three phenomena: molecular scattering over the ocean for absolute visible band calibration; ocean glint, to transfer the calibration from the visible band to the NIR band; and desert reflectance to monitor, independently, the stability of the visible and NIR bands. The method was applied to NOAA-7, -9, and -11 sensors. The results of the ocean and the desert calibration methods were found to differ in the brightness range and the spectral response of the radiance source (molecular scattering over the ocean versus the desert reflectance).

Kaufman, Y. J.↗

Instrument design and test results of the new all-reflection spatial heterodyne spectrometer

An all-reflection spatial heterodyne spectrometer (SHS) has been recently developed. The advantages over conventional high-resolution grating spectrometers are that the SHS requires no mechanical scanning, a self-compensating optical design permits easy alignment, and it is much smaller than other spectrometers of comparable resolution. Since all beam-splits and recombinations occur by reflection off of a diffraction grating, the interferometer is capable of operating well into the extreme ultraviolet (EUV) and possibly into the soft X-ray region. A description of the design and the characteristics of the instrument is presented. Also, test results, including sample interferograms as well as their Fourier-transformed spectra, at both visible and UV wavelengths are shown. Finally, we report on future developments and possible applications.

Bush, Brett C.↗

High-reflective multilayers as narrowband VUV filters

A novel coating has been developed for the 120-230 nm wavelength VUV region which yields significantly higher reflectivity over selectable bandwidths and can be used to fabricate high-performance narrowband reflection filters; the spectral properties of such filters are greatly enhanced through their use in tandem. The coating uses a combination of high and low refractive index dielectric pairs. The proper choice of high-low ratio reduces the effects of VUV absorption for high refractive index films whose extinction coefficient is much higher than for a low-index material.

Zukic, Muamer↗

Feasibility study of the use of synchrotron radiation in the calibration of AXAF - Initial reflectivity results

The 1-percent calibration accuracy goal of the Advanced X-ray Astrophysics Facility is being approached by way of an experiment at the National Synchrotron Light Source that will demonstrate the accuracy achievable in reflectance measurements conducted on coated flat mirrors in the 50 eV-12 keV energy range. The coatings will be of commercially produced Au, Ni, and Ir, deposited either by sputtering or by e-beam deposition. Optical constants will be estimated via the reflectance vs. angle-of-incidence method.

Graessle, D. E.↗

The mid-infrared reflectance of mineral mixtures (7-14 microns)

Mid-infrared reflectance spectra were measured (using an interferometer spectrometer with a 4/cm resolution) of a number of mineral mixtures (including quartz-microcline, quartz-hornblende, microcline-albite, microcline-hornblende, albite-hornblende, and albite-augite mixtures containing different proportions of the components, each in the 75-250 micron size range), and the spectra were compared with those of single components. It is shown that the mid-infrared reflectance spectra of particulate mixtures of these minerals combine linearly by volume within a very small error, as long as particles are much larger than the wavelength.

Thomson, Janice L.↗

Probability-matched reflectivity-rainfall relations for a hurricane from aircraft observations

The relation between the distribution of equivalent reflectivity, Z(sub e), measured by an airborne C-band radar and that for rain rate, R, measured concurrently by a disdrometer on the same aircraft in the eyewall and outer bands of Hurricane Anita (1977) was investigated using the probability-matching method (PMM). It was found that the pdf of R is much narrower in the outer rainbands of Hurricane Anita than in the eyewall, and that the mean rain rates are also much smaller. It is shown that the use of PMM provides more realistic relations than the conventional power-law Z-R regression relations based upon scatter-plots of disdrometer measurements, showing higher eyewall reflectivities for the same rain rates at rates in excess of 6.3 mm/h.

Marks, Frank D., Jr.↗

Extraction of soil and vegetation parameters from high resolution bi-directional reflectance spectra

High spectral resolution reflectance spectra were collected over a semi-desert grassland at both dry and wet season periods. Spectral reflectance measurements were made from several viewing angles at both low and high solar zenith angles. A mixture model was used to separate and extract green vegetation from dry/dead vegetation and soil. The extracted vegetation signal varied greatly with view and sun angle variations such that off-nadir viewing and illuminating angles resulted in the highest vegetation loadings. These variations were normalized with cosine functions for both sun and view angle. These results offer a methodology for standardizing multi-temporal and multi-angular satellite measurements of vegetation activity.

Huete, A. R.↗

Ultraviolet stability and contamination analysis of Spectralon diffuse reflectance material

A detailed chemical analysis was carried out on Spectralon, a highly Lambertian, diffuse reflectance material. Results of this investigation unambiguously identified the presence of an organic (hydrocarbon) impurity intrinsic to the commercial material. This impurity could be removed by a vacuum bake-out procedure and was identified as the cause of optical changes (degradation) that occur in the material when exposed to UV light. It was found that when this impurity was removed, the Spectralon material was photochemically stable and maintained its reflectance properties even after extensive solar UV exposure.

Stiegman, Albert E.↗