Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupoles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Application of Doppler-shift attenuation method to the de-excitation {gamma} rays from the in-flight {sup 12}Be beam

The B(E2; {down_arrow}) value of the neutron-rich nucleus {sup 12}Be has been determined through the measurement of the lifetime of the first 2{sup +} state using a modified Doppler-shift attenuation method (DSAM). The first excited state was produced by the inelastic scattering of the intermediate energy {sup 12}Be beam off a thick gold target, which played two roles, to excite the beam and to decrease the velocity. The lifetime has been determined to be 2.5{+-}0.7(stat){+-}0.3(syst) ps, which gives a B(E2) value of 5.0{+-}1.3{+-}0.5 in Weisskopf units. The result shows a large quadrupole strength in the ground state transition. The B(E2) value together with the deformation length measured by proton inelastic scattering yields a neutron quadrupole matrix element two times larger than those for {sup 14}C and {sup 16}O.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of metal nanocluster ion source based on dc magnetron plasma sputtering at room temperature

A simple and cost effective nanocluster ion source for the deposition of size selected metal nanocluster has been developed based on the dc magnetron discharge (including pulsed dc discharge). The most important and interesting feature of this cluster source is that it is working at room temperature, cooled by chilled water during the experiment. There is no extraction unit in this device and the cluster streams flow only due to the pressure gradient from source chamber to substrate via quadrupole mass filter. It has provision of multiple substrate holders in the deposition chamber, which can be controlled manually. The facility consists of quadrupole mass filter (QMF 200), which can select masses in the range of 2-125 000 atoms depending on the target materials, with a constant mass resolution (M/{Delta}M{approx}25). The dc magnetron discharge at a power of about 130 W with Ar as feed/buffer gas was used to produce the Cu nanocluster in an aggregation tube and deposited on Si (100) wafer temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A simple dual polarity dual nanoelectrospray ionization source for ion/ion reactions

A continuously operated dual polarity dual nanoelectrospray ionization source has been constructed and tested. A commercial quadrupole ion trap mass spectrometer was modified to accumulate and trap ions of opposite charge. All changes to the commercial three-dimensional quadrupole ion trap have been made external to the instrument outside of the vacuum system. Few hardware modifications were required because the two emitters send ion beams through the same transmission guides. Computer controlled source voltage polarities are switched quickly and efficiently to transmit one of two continuously generated ion beams. With customized software, this design has proved simple to implement and to operate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Twin-Helix Channel for Parametric-Resonance Ionization Cooling

Parametric-resonance Ionization Cooling (PIC)[1-3] is envisioned as the final 6D cooling stage of a high-luminosity muon collider. Implementing PIC imposes stringent constraints on the cooling channel's magnetic optics design. This paper presents a linear optics solution compatible with PIC. Our solution consists of a superposition of two opposite-helicity equal-period and equal-strength helical dipole harmonics and a straight normal quadrupole. We demonstrate that such a system can be adjusted to meet all of the PIC linear optics requirements while retaining large acceptance.

43 PARTICLE ACCELERATORS↗

In situ calibration of rotating sensor coils for magnet testing

An in situ procedure for calibrating equivalent magnetic area and rotation radius of rotating coils is proposed for testing accelerator magnets shorter than the measuring coil. The procedure exploits measurements of magnetic field and mechanical displacement inside a reference quadrupole magnet. In a quadrupole field, an offset between the magnet and coil rotation axes gives rise to a dipole component in the field series expansion. The measurements of the focusing strength, the displacement, and the resulting dipole term allow the equivalent area and radius of the coil to be determined analytically. The procedure improves the accuracy of coils with large geometrical irregularities in the winding. This is essential for short magnets where the coil dimensions constrain the measurement accuracy. Experimental results on different coils measuring small-aperture permanent magnets are shown.

42 ENGINEERING↗

A polyvalent harmonic coil testing method for small-aperture magnets

A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-resolution multi-slit phase space measurement technique for low-emittance beams

Precise measurement of transverse phase space of a high-brightness electron beamis of fundamental importance in modern accelerators and free-electron lasers. Often, the transverse phase space of a high-brightness, space-charge-dominated electron beam is measured using a multi-slit method. In this method, a transverse mask (slit/pepperpot) samples the beaminto a set of beamlets, which are then analyzed on to a screen downstream. The resolution in this method is limited by the type of screen used which is typically around 20 {mu}m for a high-sensitivity Yttrium Aluminum Garnet screen. Accurate measurement of sub-micron transverse emittance using this method would require a long drift space between the multi-slit mask and observation screen. In this paper, we explore a variation of the technique that incorporates quadrupole magnets between the multi-slit mask and the screen. It is shown that this arrangement can improve the resolution of the transverse-phase-space measurement with in a short footprint.

43 PARTICLE ACCELERATORS↗

Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging from 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.

36 MATERIALS SCIENCE↗

Magnetic properties of Nd-Ga-Fe{sub bal}-Nb-B alloy

Here, we have synthesized Nd-Ga-Fe{sub bal}-Nb-B alloy by strip casting method. The crystalline and magnetic properties of sample were investigated with x-ray diffractometer (XRD), vibrating sample magnetometer (VSM), and Mössbauer spectrometer. The XRD pattern was analyzed with the Rietveld refinement method, indicating a tetragonal structure and the space group of P4{sub 2}/mnm. The temperature dependence of zero-field cooled (ZFC) magnetization curve was measured under applied field at temperature ranging from 4.2 to 740 K. From the ZFC curve, Curie temperature and spin reorientation temperature are determined to be 615 K and 130 K, respectively. Also, Mössbauer spectra were measured at various temperatures ranging from 4.2 to 620 K. Each spectrum was fitted with 6-sextets for Fe site (8j{sub 1}, 8j{sub 2}, 16k{sub 1}, 16k{sub 2}, 4c, and 4e), and magnetic hyperfine field, Isomer shift, electric quadrupole shift, and area ratio values were obtained from the fit. We observed the change in slope of magnetic hyperfine field and electric quadrupole shift at 130 K while the Curie temperature was determined to be 615 K from the measurement of zero velocity counter, agreeing with the values obtained from VSM measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomically precise (catalytic) particles synthesized by a novel cluster deposition instrument

We report a new high vacuum instrument which is dedicated to the preparation of well-defined clusters supported on model and technologically relevant supports for catalytic and materials investigations. The instrument is based on deposition of size selected metallic cluster ions that are produced by a high flux magnetron cluster source. The throughput of the apparatus is maximized by collecting and focusing ions utilizing a conical octupole ion guide and a linear ion guide. The size selection is achieved by a quadrupole mass filter. The new design of the sample holder provides for the preparation of multiple samples on supports of various sizes and shapes in one session. After cluster deposition onto the support of interest, samples will be taken out of the chamber for a variety of testing and characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The interaction of 193 nm excimer laser radiation with single-crystal zinc oxide: Generation of long lived highly excited particles with evidence of Zn Rydberg formation

In past studies, we have observed copious emissions of ionic and atomic Zn from single-crystal ZnO accompanying irradiation of single-crystal ZnO with 193-nm excimer laser irradiation at fluences below the onset of optical breakdown. The Zn{sup +} and ground state Zn° are studied using time-of-flight techniques and are mass selected using a quadrupole mass spectrometer. Simultaneously, we have observed emitted particles that are detectable with a Channeltron electron multiplier but cannot be mass selected. It is a reasonable hypothesis that these particles correspond to a neutral atom or molecule in highly excited long lived states. We provide strong evidence that they correspond to high lying Rydberg states of atomic Zn. We propose a production mechanism involving laser excitation via a two photon resonance excitation of Zn°.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A microscopic explanation of the isotonic multiplet at N=90

The shape phase transition from spherical to soft deformed at N=88-90 was observed long ago. After the prediction of the X(5) symmetry, for which analytical solution of the nuclear Hamiltonian is given [1], good examples of X(5) nuclei were identified in the N=90 isotones of Nd, Sm, Gd and Dy, in the recent works. The N=90 isotones have almost the similar deformed level structure, forming the isotonic multiplet in Z=50-66, N=82-104 quadrant. This is explained microscopically in terms of the Nilsson level diagram. Using the Dynamic Pairing-Plus-Quadrupole model of Kumar-Baranger, the quadrupole deformation and the occupancies of the neutrons and protons in these nuclei have been calculated, which support the formation of N=88, 90 isotonic multiplets. The existence of F-spin multiplets in Z=66-82, N=82-104 quadrant, identified in earlier works on the Interacting Boson Model, is also explained in our study.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing white light luminescence in Dy{sup 3+}-doped Lu{sub 3}Ga{sub 5}O{sub 12} nano-garnets

Trivalent dysprosium-doped Lu{sub 3}Ga{sub 5}O{sub 12} nano-garnets have been prepared by sol-gel method and characterized by X-ray powder diffraction, high-resolution transmission electron microscopy, dynamic light scattering, and laser excited spectroscopy. Under a cw 457 nm laser excitation, the white luminescence properties of Lu{sub 3}Ga{sub 5}O{sub 12} nano-garnets have been studied as a function of the optically active Dy{sup 3+} ion concentration and at low temperature. Decay curves for the {sup 4}F{sub 9/2} level of Dy{sup 3+} ion exhibit non-exponential nature for all the Dy{sup 3+} concentrations, which have been well-fitted to a generalized energy transfer model for a quadrupole-quadrupole interaction between Dy{sup 3+} ions without diffusion. From these data, a simple rate-equations model can be applied to predict that intense white luminescence could be obtained from 1.8 mol% Dy{sup 3+} ions-doped nano-garnets, which is in good agreement with experimental results. Chromaticity color coordinates and correlated color temperatures have been determined as a function of temperature and are found to be within the white light region for all Dy{sup 3+} concentrations. These results indicate that 2.0 mol% Dy{sup 3+} ions doped nano-garnet could be useful for white light emitting device applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An ion mobility mass spectrometer for investigating photoisomerization and photodissociation of molecular ions

An ion mobility mass spectrometry apparatus for investigating the photoisomerization and photodissociation of electrosprayed molecular ions in the gas phase is described. The device consists of a drift tube mobility spectrometer, with access for a laser beam that intercepts the drifting ion packet either coaxially or transversely, followed by a quadrupole mass filter. An ion gate halfway along the drift region allows the instrument to be used as a tandem ion mobility spectrometer, enabling mobility selection of ions prior to irradiation, with the photoisomer ions being separated over the second half of the drift tube. The utility of the device is illustrated with photoisomerization and photodissociation action spectra of carbocyanine molecular cations. The mobility resolution of the device for singly charged ions is typically 80 and it has a mass range of 100-440 Da, with the lower limit determined by the drive frequency for the ion funnels, and the upper limit by the quadrupole mass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A look ahead: Status of the SNS external antenna ion source and the new RFQ test stand

The U.S. Spallation Neutron Source (SNS) now operates with ∼1 MW of beam power to target with the near-term goal of delivering 1.4 MW. Plans are being considered to incorporate a second target station into the facility which will require ∼2.8 MW of beam power. Presently, H{sup −} beam pulses (∼1 ms, 60 Hz) are produced by an RF-driven, Cs-enhanced, multi-cusp ion source which injects beam into an RFQ (Radio Frequency Quadrupole) accelerator that, in turn, feeds the SNS Linac. Currently the source/RFQ system delivers ∼35 mA of pulsed current to the linac which is mostly sufficient for 1.4 MW operations while ∼50 mA are needed for the second target station upgrade. This paper provides a look forward for the SNS by providing (i) the present and future SNS source/RFQ beam requirements and our plans to achieve these, (ii) a description and status of the external antenna ion source being developed for the replacement of the current internal antenna ion source, and (iii) a description and status of the newly constructed RFQ test facility.

43 PARTICLE ACCELERATORS↗

The evolution of the ion diffusion region during collisionless magnetic reconnection in a force-free current sheet

Two-dimensional particle-in-cell simulation is performed to investigate magnetic reconnection in a force-free current sheet. The results show that the evolution of the ion diffusion region has two different phases. In the first phase, the electrons flow toward the X line along one pair of separatrices and away from the X line along the other pair of separatrices. Therefore, in the ion diffusion region, a distorted quadrupole structure of the out-of-plane magnetic field is formed, which is similar to that of a typical guide field reconnection in the Harris current sheet. In the second phase, the electrons move toward the X line along the separatrices and then flow away from the X line at the inner side of the separatrices. In the ion diffusion region, the out-of-plane magnetic field exhibits a characteristic quadrupole pattern with a good symmetry, which is similar to that of antiparallel reconnection in the Harris current sheet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam based alignment and its relevance in Indus-2

Initially in the Indus-2 storage ring, the closed orbit distortion (COD) could be best corrected to 1.3 mm rms in the horizontal and 0.43 mm rms in the vertical plane. The strength of the corrector magnets required high values for COD correction. This revealed that offsets in COD readout by the beam position monitors (BPMs) played a role in not achieving a rms COD lower than the above value. Thus, the offset between the electrical center of BPMs and the magnetic center of the nearest quadrupole magnet could be estimated using the beam based alignment (BBA) method. It prefers that the quadrupole magnet is able to be controlled individually and active shunt power supply (ASPS) system was designed for this purpose that works efficiently. This paper describes the methodology of BBA, topology of ASPS and its performance, and COD minimization using the measured BPM offsets. After BBA, the COD could be reduced to 0.45 mm rms and 0.2 mm rms in horizontal and vertical planes, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗