Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “projects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Static spherically symmetric solutions to modified Horava-Lifshitz gravity with a projectability condition

In this paper we seek static spherically symmetric solutions of Horava-Lifshitz-like gravity with the projectability condition. We consider the most general form of gravity action without detailed balance, and require the spacetime metric to respect the projectability condition. We find that for any value of {lambda}, the solutions of topology RxM{sub 3} may exist, where R is the time direction and M{sub 3} is a three-dimensional maximally symmetric space depending on the value of cosmological constant and the potential of the action. Besides, in the UV region where {lambda}{ne}1, we find Minkowski or de Sitter spacetime as the solution, while in the IR region where {lambda}=1, we prove that (dS-)Schwarzschild solution is the only nontrivial solution. We also notice that the other static spherically symmetric solutions found in the literature do not satisfy the projectability condition and are not the solutions we get. Our study shows that in Horava-Lifshitz gravity with the projectability condition, there is no novel correction to Einstein's general relativity in solar system tests.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical metrics and projective equivalence

Trajectories of light rays in a static spacetime are described by unparametrized geodesics of the Riemannian optical metric associated with the Lorentzian spacetime metric. We investigate the uniqueness of this structure and demonstrate that two different observers, moving relative to one another, who both see the Universe as static may determine the geometry of the light rays differently. More specifically, we classify Lorentzian metrics admitting more than one hyper-surface orthogonal timelike Killing vector and analyze the projective equivalence of the resulting optical metrics. These metrics are shown to be projectively equivalent up to diffeomorphism if the static Killing vectors generate a group SL(2,R), but not projectively equivalent in general. We also consider the cosmological C metrics in Einstein-Maxwell theory and demonstrate that optical metrics corresponding to different values of the cosmological constant are projectively equivalent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shifting Left for Machine Learning: An Empirical Study of Security Weaknesses in Supervised Learning-based Projects

Context: Supervised learning-based projects (SLPs), i.e., software projects that use supervised learning algorithms, such as decision trees are useful for performing classification-related tasks. Yet, security weaknesses, such as the use of hard-coded passwords in SLPs, can make SLPs susceptible to security attacks. A characterization of security weaknesses in SLPs can help practitioners understand the security weaknesses that are frequent in SLPs and adopt adequate mitigation strategies. Objective: The goal of this paper is to help practitioners se-curely develop supervised learning-based projects by conducting an empirical study of security weaknesses in supervised learning-based projects. Methodology: We conduct an empirical study by quantifying the frequency of security weaknesses in 278 open source SLPs. Results: We identify 22 types of security weaknesses that occur in SLPs. We observe ‘use of potentially dangerous function’ to be the most frequently occurring security weakness in SLPs. Of the identified 3,964 security weaknesses, 23.79 % and 40.49 % respectively, appear for source code files used to train and test models. We also observe evidence of co-location, e.g., instances of command injection co-locates with instances of potentially dangerous function. Conclusion: Based on our findings, we advocate for a shift left approach for SLP development with security-focused code reviews, and application of security static analysis.

Bhuiyan, Farzana Ahamed↗

Performance Portability in the Exascale Computing Project: Exploration Through a Panel Series

Performance portability is a critical issue for the Exascale Computing Project (ECP) because of nontrivial architectural differences between machines available today and those expected at exascale. Many ECP project teams are working toward performance portability, and would expect to benefit from sharing lessons learned, identifying gaps, and discovering opportunities for partnerships. To facilitate this communication, the IDEAS-ECP project partnered with the three focus areas of ECP (application development, software technology, and hardware and integration), and Department of Energy computing facilities, to lead a series of panel discussions on performance portability. The panels were organized around broadly common themes of algorithmic and data locality challenges. In this article, we describe the panel series, its objectives, and perspectives from the various areas of the project. Finally, we also discuss use cases that are distinctive, as well as conclusions drawn from the collective experience of the participants.

97 MATHEMATICS AND COMPUTING↗

Utility-Scale Lithium-Ion Storage Cost Projections for Use in Capacity Expansion Models

This work presents U.S. utility-scale battery storage cost projections for use in capacity expansion models. We create battery cost projections based on a survey of literature cost projections of battery packs and balance of system costs, with a focus on lithium-ion batteries. Low, mid, and high cost trajectories are created for the overnight capital costs and the operating and maintenance costs. We then demonstrate the impact of these cost projections in the Regional Energy Deployment System (ReEDS) capacity expansion model. We find that under reference scenario conditions, lower battery costs can lead to increased penetration of variable renewable energy, with solar photovoltaics (PV) seeing the largest increase. We also find that additional storage can reduce renewable energy curtailment, although that comes at the expense of additional storage losses.

25 ENERGY STORAGE↗

Progress of the PV Technology Incubator Project Towards an Enhanced U.S. Manufacturing Base

In this paper, we report on the major accomplishments of the U.S. Department of Energy's (DOE) Solar Energy Technologies Program (SETP) Photovoltaic (PV) Technology Incubator project. The Incubator project facilitates a company's transition from developing a solar cell or PV module prototype to pilot- and large-scale U.S. manufacturing. The project targets small businesses that have demonstrated proof-of-concept devices or processes in the laboratory. Their success supports U.S. Secretary of Energy Steven Chu's SunShot Initiative, which seeks to achieve PV technologies that are cost-competitive without subsidies at large scale with fossil-based energy sources by the end of this decade. The Incubator Project has enhanced U.S. PV manufacturing capacity and created more than 1200 clean energy jobs, resulting in an increase in American economic competitiveness. The investment raised to date by these PV Incubator companies as a result of DOE's $ 59 million investment total nearly $ 1.3 billion.

14 SOLAR ENERGY↗

IAM-FIRE: a Climate Emulator–Based Framework to Project Wildfire Impacts and Risks for Integrated Assessment Models

Most Integrated Assessment Models (IAMs) underrepresent dynamic feedbacks from climate-driven disturbances such as wildfires, potentially overestimating the permanence of land-based carbon sinks. In particular, representing the impacts of forest fires is becoming increasingly important, as these are expected to intensify in the coming years. We introduce IAM-FIRE (Integrated Assessment Model – Fire Impacts & Risks Emulator), a novel framework that enables the projection of wildfire burned area (BA) and carbon emissions (CE) directly from IAM outputs. IAM-FIRE combines a spatial climate emulator, land-use downscaling, vegetation productivity modelling, and an empirical fire model to generate global annual wildfire impacts for arbitrary socioeconomic and emissions scenarios at 0.5° resolution for the period 2020–2100. Calibrated against GFEDv5 observations and using inputs from the Global Change Analysis Model (GCAM), we report projections BA and CE derived from IAM-FIRE for four scenarios: SSP1-2.6, SSP2-4.5, SSP3-6.6 and SSP5-7.6. The model reproduces historical global trends for total BA, including the observed global decline since the early 2000s, and for forest BA. Projected fire trajectories differ strongly among scenarios: total BA range from declines under SSP1-2.6 (-3.36 Mha yr-1) to increases under SSP3-6.6 (+1.6 Mha yr-1). Corresponding total CE show a similar divergence ranging from -15 to +10.6 TgC yr-1. Socioeconomic development exerts a dominant suppressing effect on wildfire impacts while climate change and CO2-driven increases in vegetation productivity amplify fire risk, particularly under high-emissions pathways. Compared with CMIP6 fire-enabled Earth System Models, IAM-FIRE exhibits greater sensitivity to radiative forcing and a stronger role for human-driven fire suppression, highlighting substantial structural uncertainties in future fire projections. By providing a computationally efficient and internally consistent approach to represent wildfire impacts within IAMs, IAM-FIRE enables systematic exploration of fire–climate–land feedbacks and supports improved assessments of mitigation permanence and climate risks in future integrated scenarios.

Rouhette, Theo↗

Background and Reflections on the Life Cycle Assessment Harmonization Project

Despite the ever-growing body of life cycle assessment (LCA) literature on electricity generation technologies, inconsistent methods and assumptions hamper comparison across studies and pooling of published results. Synthesis of the body of previous research is necessary to generate robust results to assess and compare environmental performance of different energy technologies for the benefit of policy makers, managers, investors, and citizens. With funding from the U.S. Department of Energy, the National Renewable Energy Laboratory initiated the LCA Harmonization Project in an effort to rigorously leverage the numerous individual studies to develop collective insights. The goals of this project were to: (1) understand the range of published results of LCAs of electricity generation technologies, (2) reduce the variability in published results that stem from inconsistent methods and assumptions, and (3) clarify the central tendency of published estimates to make the collective results of LCAs available to decision makers in the near term. The LCA Harmonization Project's initial focus was evaluating life cycle greenhouse gas (GHG) emissions from electricity generation technologies. Six articles from this first phase of the project are presented in a special supplemental issue of the Journal of Industrial Ecology on Meta-Analysis of LCA: coal (Whitaker et al. 2012), concentrating solar power (Burkhardt et al. 2012), crystalline silicon photovoltaics (PVs) (Hsu et al. 2012), thin-film PVs (Kim et al. 2012), nuclear (Warner and Heath 2012), and wind (Dolan and Heath 2012). Harmonization is a meta-analytical approach that addresses inconsistency in methods and assumptions of previously published life cycle impact estimates. It has been applied in a rigorous manner to estimates of life cycle GHG emissions from many categories of electricity generation technologies in articles that appear in this special supplemental supplemental issue, reducing the variability and clarifying the central tendency of those estimates in ways useful for decision makers and analysts. Each article took a slightly different approach, demonstrating the flexibility of the harmonization approach. Each article also discusses limitations of the current research, and the state of knowledge and of harmonization, pointing toward a path of extending and improving the meta-analysis of LCAs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Presentation of FP7 matter project: general overview

The 2010-2012 implementation plan of the European Sustainable Nuclear Industrial Initiative (ESNII), prepared in the frame of the Sustainable Nuclear Energy Technology Platform (SNETP), establishes a very tight time schedule for the start of construction of the European Gen IV prototypes; namely the construction of the LFR ETPP (European Technology Pilot Plant) MYRRHA will start in 2014 and that of the SFR Prototype ASTRID will start in 2017. The GEN IV reactors pose new challenges to the designers and scientists in terms of higher operating temperature, higher fuel burn-up, and in some cases more corrosive environment with respect to the present technologies and which impacts the materials performance. In this frame, the MATTER (Materials Testing and Rules) Project starts well targeted R and D activities to perform careful materials studies in GEN IV operational conditions and to find out criteria for the correct use of these materials in relevant reactor applications. Aim of the MATTER Project (that involved 27 partners and will end in 2015) is to complement the materials researches, in the frame of the European Energy Research Alliance (EERA) guidelines, with the implementation of pre-normative rules. The MATTER Project is divided in 3 technical Domains (called DM): DM1 - Development of test and evaluation guidelines for structural materials: to develop/establish best practice guidelines for testing and evaluation procedures, which are aimed to screen and characterize nuclear materials for innovative nuclear systems. DM2 - Pre-normative R and D for Codes and Standards: Pre-normative activities are performed, comprehensive of experiments, to revise and update the design rules (with an EU level consensus) in order to answer to some short term needs of the two projects ASTRID and MYRRHA with respect to the design and the construction of structural components. DM3 - Joint Program Scheme, implementation and Priorities: to optimise the effectiveness and efficiency of the EERA Joint Program on nuclear materials for innovative reactors and to support specific research activities related to fundamental understanding of ODS steels fabrication. ODS steels are considered candidate materials, in the medium-long term, for high fuel burn-up cladding application. After a brief presentation of DM1 and DM3, this paper mainly focuses on description of Pre-normative R and D activities for Codes and Standards (DM2). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation

Purpose: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range. Methods: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure. Results: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively. Conclusions: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of {approx}360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-05: Calculating Tumor Trajectory and Dose-Of-The-Day for Highly Mobile Tumors Using Cone-Beam CT Projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed a method using these projections to determine the trajectory and dose of highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, where the trajectory mimicked a lung tumor with high amplitude (2.4 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each projection. A Gaussian probability density function for tumor position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two methods to improve the accuracy of tumor track reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation, and second, using the Monte Carlo method to sample the estimated Gaussian tumor position distribution. 15 clinically-drawn abdominal/lung CTV volumes were used to evaluate the accuracy of the proposed methods by comparing the known and calculated BB trajectories. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square (RMS) trajectory errors were lower than 5% of marker amplitude. Use of respiratory phase information decreased RMS errors by 30%, and decreased the fraction of large errors (>3 mm) by half. Mean dose to the clinical volumes was calculated with an average error of 0.1% and average absolute error of 0.3%. Dosimetric parameters D90/D95 were determined within 0.5% of maximum dose. Monte-Carlo sampling increased RMS trajectory and dosimetric errors slightly, but prevented over-estimation of dose in trajectories with high noise. Conclusions: Tumor trajectory and dose-of-the-day were accurately calculated using CBCT projections. This technique provides a widely-available method to evaluate highly-mobile tumors, and could facilitate better strategies to mitigate or compensate for motion during SBRT.

60 APPLIED LIFE SCIENCES↗

Calculating tumor trajectory and dose-of-the-day using cone-beam CT projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. The authors developed and validated a method which uses these projections to determine the trajectory of and dose to highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, the trajectory of which mimicked a lung tumor with high amplitude (up to 2.5 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each CBCT projection, and a Gaussian probability density function for the absolute BB position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two modifications of the trajectory reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation (Phase), and second, using the Monte Carlo (MC) method to sample the estimated Gaussian tumor position distribution. The accuracies of the proposed methods were evaluated by comparing the known and calculated BB trajectories in phantom-simulated clinical scenarios using abdominal tumor volumes. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square trajectory errors averaged 3.8% ± 1.1% of the marker amplitude. Dosimetric calculations using Phase methods were more accurate, with mean absolute error less than 0.5%, and with error less than 1% in the highest-noise trajectory. MC-based trajectories prevent the overestimation of dose, but when viewed in an absolute sense, add a small amount of dosimetric error (<0.1%). Conclusions: Marker trajectory and target dose-of-the-day were accurately calculated using CBCT projections. This technique provides a method to evaluate highly mobile tumors using ordinary CBCT data, and could facilitate better strategies to mitigate or compensate for motion during stereotactic body radiotherapy.

60 APPLIED LIFE SCIENCES↗

Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Results of the Nuclotron-M project

The main goal of the Nuclotron-M project, approved in 2007, was formulated as follows: modernization of the main accelerator systems for reliable and safe operation of the Nuclotron as a part of the accelerator facility NICA (Nuclotron-based Ion Collider Facility) being constructed at JINR. Demonstration of heavy-ion beam acceleration (with atomic mass number higher than 100) as well as safe and stable operation of the main superconducting system operation at a magnetic field of up to 2 T had been defined as criteria of successful project fulfillment. Another very important issue is performance of stable, long-term beam runs and increase of the accelerated beam intensity. All the main goals of the Nuclotron-M project had been successfully achieved by the end of 2010. In this report we give an overview of the project realization chronology and present the main experimental results obtained at LHEP Nuclotron accelerator facility in the period from 2007 to early 2011.

43 PARTICLE ACCELERATORS↗

Modified Method for Reconstructing the Image from Projections in Magnetic Resonance Tomography

A method for reconstructing the image from projections in magnetic resonance tomography using an excitation pulse with a linear frequency modulation has been considered. The shape of the spin echo envelope coincides with the projection of the spin density onto the direction of the axis along which the magnetic field gradient is applied. The spin echo excitation by a sinc pulse and a pulse with a linear frequency modulation has been simulated. The former pulse excites the required cross section of a 3D object, while the latter pulse has made it possible to form the spin echo envelope, which coincides in shape with the projection of the spin density of nuclei onto the direction of the gradient. The set of the projections onto different directions of the gradient has made it possible to reconstruct the 2D image of a section.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Function Preserving Projection

With function preserving projection (FPP), we aim to address high-dimensional data exploration challenges common in many scientific applications. Instead of preserving the global or local geometric structure of a dataset like traditional dimensionality reduction methods (e.g., principal component analysis, t-stochastic neighborhood embedding), the proposed approach finds a linear projection that reveal interpretable (yet potentially nonlinear) pattern of the properties of interests defined on a highdimensional domain (e.g., simulation yield defined on the input parameter space). The key insight driving FPP is the fact that while non-linear embeddings are difficult to interpret, humans are highly skilled in understanding complex visual patterns. FPP lets users select the complexity of a pattern they consider interpretable, allows to find a joint projection that explains multiple functions, and provides a confidence statistic (akin to a p-value) indicating how salient the resulting pattern is. We demonstrate the efficacy of the proposed method on several synthetic and scientific datasets for both continuous (regression) and discrete (classification) problems of interests and illustrate the scalability of FPP by finding an optimal projection for close to 40 gigabytes in around 10 minutes.

Liu, SHUSEN↗