Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Risk-Reduction Autonomy Implementation to Enable NASA Artemis Missions

To achieve NASA’s Artemis program mission objectives a high level of autonomy that is ubiquitous throughout the systems that are being developed will be necessary. The autonomous systems of Artemis will require a distributed autonomy capability, with autonomous systems organized functionally in a hierarchical architecture, where systems at higher levels of the hierarchy have authority over systems at lower levels. The challenge of developing autonomy technologies and Concepts of Operations (ConOps) for Artemis has been undertaken by the NASA Gateway Working Group. This group has developed requirements, architectures, ConOps, and interface control documents (ICDs), in the context of a hierarchical distributed architecture that includes the following: a Vehicle System Manager (VSM) that autonomously manages the entire Gateway; Module System Managers (MSMs) that autonomously manage each module; and System Managers (SMs) that autonomously manage systems within a module (i.e. ECLSS). A substantially high level of autonomy needs to be achieved by each element of the hierarchy (VSM, MSM, SM) to meet requirements for uncrewed operations; this includes conditions that will have minimal and/or delayed ground intervention (i.e. requirements for sustainability for months of operation without crew or ground support). To advance an implementation of this autonomy design (Gateway Autonomy Design – GAD), a collaboration was established between the Autonomous Systems Laboratory (ASL) at NASA Stennis Space Center and Lockheed Martin. The objectives of this partnership were the following: (1) to implement autonomy at the VSM, MSM, and SM levels; (2) to implement communications among a VSM, 2 MSMs, ORION (a visiting vehicle somewhat equivalent to a module) and 1 SM (a power system), and (3) test autonomous operations with representative use cases. A SM backed by a high-fidelity simulation was created to facilitate demonstrations of use cases that originated in a system of a module. Communication between the VSM and MSMs was implemented according to Concepts of Operations and Interface Control Documents (ICDs). Demonstrations were conducted to address nominal and off-nominal operations and multi-module interactions with the VSM. Additionally, user interfaces were created to provide awareness about ongoing processes and results while enhancing the demonstration. Demonstrations included the following use cases: (1) Orion as visiting vehicle registers with VSM; (2) VSM reschedules a module’s timelines when another module’s MSM task fails; and (3) a module’s Power System Manager (PSM) demonstration that included component failure diagnostics, tracing component failure to effected components, which in turn, reports failure information up to the VSM for acknowledgement and display. This paper will describe the detailed technology and autonomous systems developed, and the integrated multi-module demonstrations conducted. Also, challenges that must be met to fully implement the GAD defined by Gateway will be addressed.

Fernando Figueroa↗

SRG110 Stirling Generator Dynamic Simulator Vibration Test Results and Analysis Correlation

The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Stirling Radioisotope Generator (SRG110) for use as a power system for space science missions. The launch environment enveloping potential missions results in a random input spectrum that is significantly higher than historical radioisotope power system (RPS) launch levels and is a challenge for designers. Analysis presented in prior work predicted that tailoring the compliance at the generator-spacecraft interface reduced the dynamic response of the system thereby allowing higher launch load input levels and expanding the range of potential generator missions. To confirm analytical predictions, a dynamic simulator representing the generator structure, Stirling convertors and heat sources were designed and built for testing with and without a compliant interface. Finite element analysis was performed to guide the generator simulator and compliant interface design so that test modes and frequencies were representative of the SRG110 generator. This paper presents the dynamic simulator design, the test setup and methodology, test article modes and frequencies and dynamic responses, and post-test analysis results. With the compliant interface, component responses to an input environment exceeding the SRG110 qualification level spectrum were all within design allowables. Post-test analysis included finite element model tuning to match test frequencies and random response analysis using the test input spectrum. Analytical results were in good overall agreement with the test results and confirmed previous predictions that the SRG110 power system may be considered for a broad range of potential missions, including those with demanding launch environments.

Lewandowski, Edward J.↗

Integrating Analytical Solutions and U-Net Model for Predicting Groundwater Contaminant Plumes in Pump-and-Treat Systems

Pump-and-treat (P&T) is a common technique for groundwater remediation involving the extraction and treatment of contaminated water above ground. Optimizing the design and operation of the P&T well network is essential for maximizing the system’s effectiveness and efficiency. However, this optimization often necessitates many model evaluations, leading to computationally demanding tasks. This study introduces a novel approach that integrates analytical solutions for groundwater dynamics with the U-Net (Ronneberger et al., 2015) deep learning framework to predict groundwater contaminant plume migration under dynamic pumping conditions. By incorporating the Thiem equation (Thiem, 1906) into the input preprocessing, the U-Net model transforms sparse well data into a continuous spatial field that captures the hydraulic impacts of pumping activities. This integration enables the model to leverage both deep learning capabilities and classical physics-based groundwater theories, enhancing prediction accuracy and computational efficiency. These advancements can facilitate rapid, large-scale evaluations of P&T optimization simulations, allowing for timely and effective decision-making in well placement and system management. We demonstrate the model's robust performance across both simplified transient 2D models and a more complex 3D heterogeneous site model at the 200 West P&T facility at the Hanford Site. The U-Net-based model offers substantial computational advantages, reducing simulation times significantly compared to full physics-based models and providing a powerful tool for rapid site evaluation and P&T system optimization, such as evaluating alternative P&T well network designs. Our findings highlight the potential of advanced machine learning models to significantly enhance the efficiency and sustainability of groundwater remediation efforts, offering a novel application of U-Net architecture in environmental science.

Pump-and-treat↗

Oak Ridge National Laboratory's Strategic Research and Development Insights for Digital Twins

Oak Ridge National Laboratory (ORNL) is pleased to provide our response to the NITRD RFI on Digital Twins Research and Development. Digital twins are virtual representations of physical systems, leveraging real-time data to simulate and predict behaviors. ORNL is advancing digital twin technology across various disciplines, including neutron scattering, networking, science ecosystems, supercomputing, secure facilities, mobility technologies, materials design and discovery, power systems, fusion reactors, biological sciences, and earth observation. These efforts aim to enhance scientific research, operational efficiency, and decision-making processes. ORNL facilities, such as the High Flux Isotope Reactor (HFIR), Grid-C, Spallation Neutron Source (SNS), and Oak Ridge Leadership Computing Facility (OLCF), provide the infrastructure to develop and demonstrate these digital twin technologies. In this document, we lay out key challenges, research gaps, and future opportunities based on our experience with digital twins that aim to serve as useful contributions towards a National Digital Twins R&D Strategic Plan. In the remaining document, we address nine of the thirteen topic areas specified in the RFI.

97 MATHEMATICS AND COMPUTING↗

Ensemble Learning Based Convex Approximation of Three-Phase Power Flow

Though the convex optimization has been widely used in power systems, it still cannot guarantee to yield a tight (accurate) solution to some problems. To mitigate this issue, this paper proposes an ensemble learning based convex approximation for alternating current (AC) power flow equations that differs from the existing convex relaxations. The proposed approach is based on three-phase quadratic power flow equations in rectangular coordinates. To develop this data-driven convex approximation of power flows, the polynomial regression (PR) is first deployed as a basic learner to fit convex relationships between the independent and dependent variables. Then, ensemble learning algorithms such as gradient boosting (GB) and bagging are introduced to combine learners to boost model performance. Based on the learned convex approximation of power flow, optimal power flow (OPF) is formulated as a convex quadratic programming problem. The simulation results on IEEE standard cases of both balanced and unbalanced systems show that, in the context of solving OPF, the proposed data-driven convex approximation outperforms the conventional semi-definite programming (SDP) relaxation in both accuracy and computational efficiency, especially in the cases that the conventional SDP relaxation fails

Convex approximation↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3, full-scale power plant development

A 25 cell stack of the 13 inch x 23 inch cell size (about 4kW) remains on test after 6000 hours, using simulated reformate fuel. A similar stack was previously shut down after 7000 hours on load. These tests were carried out for the purpose of assessing the durability of fuel cell stack components developed through the end of 1983. In light of the favorable results obtained, a 25kW stack that will contain 175 cells of the same size is being constructed using the same technology base. The components for the 25kW stack have been completed. A methanol steam reformer with a design output equivalent to 50kW has been constructed to serve as a hydrogen generator for the 25kW stack. This reformer and the balance of the fuel processing sub system are currently being tested and debugged. The stack technology development program focused on cost reduction in bipolar plates, nonmetallic cooling plates, and current collecting plates; more stable cathode catalyst support materials; more corrosion resistant metal hardware; and shutdown/start up tolerance.

Kaufman, A.↗

Integration of a Microturbine Power Conversion Unit in MAGNET

The Microreactor Agile Non-nuclear Experimental Testbed (MAGNET) facility is being constructed at Idaho National Laboratory’s (INL’s) Energy Systems Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will accommodate various types of test articles representative of different microreactor designs. A power conversion unit (PCU) simulator loop was proposed to use the rejected heat from the test article and mimic the thermal hydraulic conditions (e.g., temperature, pressure and flow rate) that would be experienced if an actual Brayton cycle PCU was attached. However, due to the high-estimated cost of the PCU simulator and the availability of a turbogenerator used for previous testing at Sandia National Laboratories, the PCU simulator design was abandoned in favor of integrating an actual PCU into MAGNET. A commercial Capstone C30 was modified by Sandia to use external electrical heating, rather than combustion heating, to provide a power output from 1 to ~30 kWe. The C30 has a single-stage centrifugal combustor, a static radial heat exchanger, and a radial inflow turbine arranged on a single shaft with a high-speed alternator. Since the operating temperature and energy transfer per unit working fluid mass are comparable, the MAGNET PCU will provide researchers with the ability to evaluate the test article heat transfer under representative operating conditions with the transient system behavior associated with a closed Brayton cycle PCU. This report examines the integration of a modified commercial Capstone C30 turbogenerator into MAGNET, outlines a proposed set of tests, and describes future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental system for drilling simulated lunar rock in ultrahigh vacuum

An experimental apparatus designed for studying drillability of hard volcanic rock in a simulated lunar vacuum of 5 x 10 to the minus 10th power torr is described. The engineering techniques used to provide suitable drilling torque inside the ultrahigh vacuum chamber while excluding all hydrocarbon are detailed. Totally unlubricated bearings and gears were used to better approximate the true lunar surface conditions within the ultrahigh vacuum system. The drilling system has a starting torque of 30 in-lb with an unloaded running torque of 4 in-lb. Nominal torque increase during drilling is 4.5 in-lb or a total drilling torque of 8.5 in-lb with a 100-lb load on the drill bit at 210 rpm. The research shows conclusively that it is possible to design operational equipment for moderate loads operating under UHV conditions without the use of sealed bearings or any need of lubricants whatsoever.

Roepke, W. W.↗

Autonomous Power Controller for the NASA Gateway

Intelligent autonomous control of a spacecraft is an enabling technology that must be developed for deep space human exploration. NASA's current long term human space platform, the International Space Station which is in Low Earth Orbit, is in almost continuous communication with ground based mission control. This allows near real-time operation of all the vehicle core systems, including power, from the ground. As the focus shifts from Low Earth Orbit to deep space, challenges associated with communication time-lag and bandwidth limitations beyond geosynchronous orbit do not permit this type of ground based operation. These communication limitations motivate autonomous vehicle operations, including the vehicle subsystems such as power. This presentation will describe the ongoing development of an Autonomous Power Control (APC) system that can be used for a deep space exploration spacecraft. This work extends previous work on developing an autonomous power control which includes developing a control architecture for deep space vehicles, the use of software agents, and constructing a control simulation lab for demonstrating this capability. This presentation will begin with a discussion of the representative future power architectures that will be required for deep space exploration vehicles. The presentation then will describe how the power controller will integrate with the vehicle followed with a discussion of the autonomous power controller. Next it will describe the test setup used to evaluate the performance of the system and lastly show some of the test results. To develop the type of controller envisioned, it will be necessary to employ a detailed real-time simulation to evaluate its performance and ultimately verify its functionality.

Csank, Jeffrey↗

Autonomous Power Control

Intelligent autonomous control of a spacecraft is an enabling technology that must be developed for deep space human exploration. NASA's current long term human space platform, the International Space Station which is in Low Earth Orbit, is in almost continuous communication with ground based mission control. This allows near realtime operation of all the vehicle core systems, including power, from the ground. As the focus shifts from Low Earth Orbit to deep space, challenges associated with communication time-lag and bandwidth limitations beyond geosynchronous orbit do not permit this type of ground based operation. These communication limitations motivate autonomous vehicle operations, including the vehicle subsystems such as power. This presentation will describe the ongoing development of an Autonomous Power Control (APC) system that can be used for a deep space exploration spacecraft. This work extends previous work on developing an autonomous power control which includes developing a control architecture for deep space vehicles, the use of software agents, and constructing a control simulation lab for demonstrating this capability. This presentation will begin with a discussion of the representative future power architectures that will be required for deep space exploration vehicles. The presentation then will describe how the power controller will integrate with the vehicle followed with a discussion of the autonomous power controller. Next it will describe the test setup used to evaluate the performance of the system and lastly show some of the test results. To develop the type of controller envisioned, it will be necessary to employ a detailed real-time simulation to evaluate its performance and ultimately verify its functionality.

Csank, Jeffrey↗

A Distributed Trust Model Simulator for Energy Grid of Things Distributed Energy Resource Management System

The evolution of networks into more distributed, self-reliant nodes has mitigated single-point failures that plagued traditional centralized networks. Applied to power grids, distributed systems can increase the integrity and availability of grid services while also offering a power management solution. However, while distributed networks provide scalability, security, and sustainability compared to centralized networks, their distributed nature makes them harder for anomaly detection and prevention. Incorporating a Distributed Trust Model (DTM) System into an Energy Grid of Things Distributed Energy Resource Management System (EGOT DERMS) allows grid participants to be characterized and their communication to be analyzed for possible attacks. A Trust Model simulator is needed to evaluate and improve the DTM System.Trustworthiness is calculated using a Trust Model. While many trust models exist, most only consider 2-3 matrices to evaluate trust. The TM proposed in this thesis uses a Metric Vector of Trust (MVoT) monitoring 17 parameters when assessing trust. Moreover, unlike standard trust models, the proposed trust model establishes a method to test the trust between various actors within the network and probe the trust model itself. Using a Trust Model Simulator, MVoT calaculations, initial values, and parameters are fine-tuned to achieve high-confidence message classifications and minimize false positives. The DTM System and Trust Mode Simulation Suite allow for distributed trust evaluation with a real-time classification of EGOT DERMS actors, providing additional security for distributed systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.

Polzin, K. A.↗

Simulations of radiatively cooled magnetic reconnection driven by pulsed power

Magnetic reconnection is an important process in astrophysical environments, as it reconfigures magnetic field topology and converts magnetic energy into thermal and kinetic energy. In extreme astrophysical systems, such as black hole coronae and pulsar magnetospheres, radiative cooling modifies the energy partition by radiating away internal energy, which can lead to the radiative collapse of the reconnection layer. In this paper, we perform two- and three-dimensional simulations to model the MARZ (Magnetic Reconnection on Z) experiments, which are designed to access cooling rates in the laboratory necessary to investigate reconnection in a previously unexplored radiatively cooled regime. These simulations are performed in GORGON, an Eulerian two-temperature resistive magnetohydrodynamic code, which models the experimental geometry comprising two exploding wire arrays driven by 20 MA of current on the Z machine (Sandia National Laboratories). Radiative losses are implemented using non-local thermodynamic equilibrium tables computed using the atomic code Spk, and we probe the effects of radiation transport by implementing both a local radiation loss model and P 1/3 multi-group radiation transport. The load produces highly collisional, super-Alfvénic (Alfvén Mach number M A ≈ 1.5), supersonic (Sonic Mach number M S ≈ 4–5) strongly driven plasma flows which generate an elongated reconnection layer (Aspect Ratio L/δ≈100 , Lundquist number S L ≈ 400). The reconnection layer undergoes radiative collapse when the radiative losses exceed the rates of ohmic and compressional heating (cooling rate/hydrodynamic transit rate = τ$^{–1}_{cool}$/τ$^{–1}_{H}$ ≈100); this generates a cold strongly compressed current sheet, leading to an accelerated reconnection rate, consistent with theoretical predictions. Lastly, the current sheet is also unstable to the plasmoid instability, but the magnetic islands are extinguished by strong radiative cooling before ejection from the layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Umbilical Fatigue Analysis for a Wave Energy Converter

Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.

50 EE - Wind and Water Power Program - Water (EE-4↗

SPIKE-Dx : A Low-Power High-Throughput Fault Diagnostics Tool using Spiking Neural Networks for Constrained Systems

Diagnostic systems are important for many aerospace systems, which are severely limited in available power, like cubesats or UAVs. Therefore, traditional diagnostics systems cannot be used due to their substantial footprint and constraints. In this paper, we present our very low power diagnostic tool SPIKE-DX to monitor critical systems with constrained computational and energy resources. This is made possible through spiking neural networks (SNNs), which are executable within optimized simulation environments and further implemented on on cutting-edge neuromorphic hardware. Based upon FMEA (Failure Mode and Effect Analysis) framework, Diagnostic Bayesian Networks (DBNs) can be constructed that provide powerful means for diagnostic reasoning. In this paper, we describe such DBNs and a method to automatically translate the DBN into highly structured networks of spiking neurons for execution in SPIKE-DX.

Spiking Neural Networks↗

A Station-hybrid HVDC System Structure and Control Strategies for Cross-seam Power Transmission

Cross-seam high voltage DC (HVDC) transmission in the United States can provide an efficient and flexible bulk power delivery highway between the interconnections. Recent studies have shown significant economic benefits of cross-seam HVDC transmission systems by taking the advantages of load diversity, frequency response, renewable energy diversity, and energy arbitrage in the different interconnections. This paper introduces a station-hybrid system scheme for cross-seam interconnections. Here, the proposed station-hybrid system combines the advantages of line commutated converter (LCC) and voltage source converter (VSC) technologies, thus enabling reliable and flexible bidirectional power flows across the interconnections. Control strategies of the station-hybrid system are investigated with a focus on power flow reversal control under normal operation conditions and grid support control under emergency conditions. The feasibility and effectiveness of the proposed station-hybrid system and corresponding control strategies are verified by simulations in PSCAD/EMTDC.

Station-hybrid system↗

Advanced Stirling Convertor Dual Convertor Controller Testing at NASA Glenn Research Center in the Radioisotope Power Systems System Integration Laboratory

NASA Glenn Research Center (GRC) developed a non-nuclear representation of a Radioisotope Power System (RPS) consisting of a pair of Advanced Stirling Convertors (ASC), a Dual Convertor Controller (DCC) EM (engineering model) 2 & 3, and associated support equipment, which were tested in the Radioisotope Power Systems System Integration Laboratory (RSIL). The DCC was designed by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL) to actively control a pair of Advanced Stirling Convertors (ASC). The first phase of testing included a Dual Advanced Stirling Convertor Simulator (DASCS) which was developed by JHU/APL and simulates the operation and electrical behavior of a pair of ASC's in real time via a combination of hardware and software. RSIL provides insight into the electrical interactions between a representative radioisotope power generator, its associated control schemes, and realistic electric system loads. The first phase of integration testing included the following spacecraft bus configurations: capacitive, battery, and supercapacitor. A load profile, created based on data from several missions, tested the RPS and RSIL ability to maintain operation during load demands above and below the power provided by the RPS. The integration testing also confirmed the DCC's ability to disconnect from the spacecraft when the bus voltage dipped below 22 V or exceeded 36 V. Once operation was verified with the DASCS, the tests were repeated with actual operating ASC's. The goal of this integration testing was to verify operation of the DCC when connected to a spacecraft and to verify the functionality of the newly designed RSIL. The results of these tests are presented in this paper.

systems integration↗