Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Reliable and Efficient Electrochemical Recovery of O 2 from Metabolic CO 2 at the International Space Station (ISS)

Maximum O 2 recovery from metabolic carbon dioxide (CO 2 ) is desired for future long-duration missions beyond Low Earth Orbit (LEO). The O 2 recovery for the Environmental Control and Life Support System (ECLSS) at the International Space Station (ISS), presently limited to 50% (Sabatier), must be highly reliable and efficient and recover a minimum of 75% oxygen (O 2 ) from metabolic CO 2 . An alternative technology development effort currently underway at NASA Marshall Space Flight Center (MSFC) via a Microfluidic Electrochemical Reactor (MFECR) approach has the potential to increase O 2 recovery significantly and reduce the complexity of the ECLSS O 2 recovery at the ISS as it would replace three pieces, the CO 2 Reduction Assembly (CRA) (Sabatier reactor), the Oxygen Generation Assembly (OGA), and the Plasma Pyrolysis Assembly (PPA). The MFECR's electrochemical process generates ethylene (C 2 H 4 ) and carbon moxide (CO) instead of methane (CH 4 ) (Sabatier) as a byproduct, eliminating the need for further dehydrogenation through the PPA. As in the OGA, the MFECR's electrochemical process generates O 2 and hydrogen (H 2 ) from the water electrolysis process. MSFC and the University of Texas in Arlington (UTA) have jointly designed and fabricated an MFECR's single cell that operates at ambient conditions and utilizes a proprietary catalysis highly selective on reducing CO 2 to C 2 H 4 and CO at the cathode. This MFECR's single cell consists of gas diffusion layers at the cathode and anode for respective intake of CO 2 and output of O 2 from the catalytic layer. This approach is expected to substantially improve the ISS ECLSS sustainability and reduce power and weight requirements as the MFECR would replace three units currently installed in the ISS. In this paper, the authors discuss the outcome of preliminary tests, the current development, and the evaluation efforts on different alternatives for the cathode and the anode configurations, the setup of the MFECR at an engineering development unit (EDU) scale, and the O 2 recovery performance, and evaluation efforts on different alternatives on not only the configuration and setup of the MFECR at an Engineering Design Unit (EDU) scale but also the selection of component materials.

Jesus A Dominguez↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Developing Autonomous Technologies for Biological Missions to Deep Space

In upcoming biological missions beyond low Earth orbit (LEO), the use of autonomous instrumentation will allow scientists to perform a variety of experiments, including the characterization of the response to different space environments (Moon, Mars, interplanetary space) using biological models like microbes, plants, organoids, and tissue chips. BioSentinel is an ongoing deep space mission, currently at over 50 million kilometers from Earth and the first instrument developed to perform biological experiments beyond LEO. Even though the primary objective of this CubeSat mission was to investigate the effects of the deep space radiation environment on budding yeast, the spacecraft bus (i.e., all the subsystems that support the biological payload like power, thermal, data telemetry, navigation, etc.) can accommodate a variety of biological (and physical) experiments and model organisms. LEIA, an upcoming CLPS mission to the lunar surface, uses a microfluidic and optical instrument based on BioSentinel to study the effects of the lunar environment on different cellular processes and on bioproduction of antioxidants. A new series of science mission concepts are being proposed to be accommodated into platforms like BioSentinel. These missions will investigate the response of a variety of organisms to the deep space environment, including but not limited to single-cell eukaryotes, cyanobacteria, plants (including crops), organoids, and tissue chips. In addition to optical absorbance measurements like the ones performed in BioSentinel (and LEIA), we are investigating the use of fluorescence detection, microscopy, sequencing devices, etc. Thus, instruments like the ones proposed here can be adapted to a variety of platforms like free-flyers, deployable payloads, landers, rovers, and the lunar Gateway. These technologies can be used as steppingstones for establishing a sustained human presence on the Moon and in deep space while providing knowledge for the development of potential countermeasures.

Sergio R Santa Maria↗

Yeast Strain Development and Hardware Testing in Preparation of a Lunar BioSensor

With Artemis missions underway, it is clear we are going back to the Moon to stay. Before sending Astronauts for long-duration missions, it is crucial to understand the technological and biomedical countermeasures needed to protect them before they get there. We can use knowledge gained from biological CubeSats to guide the next generation of experiments to support human habitation on the Moon. Lunar Explorer Instrument for space biology Applications (LEIA) is NASA’s latest BioSensor, adapted BioSentinel, the only CubeSat to travel Beyond Low Earth Orbit. BioSentinel launched on Artemis I and is currently >50 million kilometers from Earth (as of July 2024). LEIA aims to identify biological responses to the Lunar environment, which unprotected against would pose a threat to astronauts (cancer, cardiovascular disease, neurological impairment). The suite of instruments within LEIA detects Lunar radiation using two on-board radiation sensors (ARES charged particle detector, Mini-Fast Neutron Detector), then monitors real-time biological responses to the Lunar environment via an autonomous microfluidic system, fit with 3-LED emitter and detector boards and the alamarBlue metabolic indicator dye. LEIA will use a genetic approach in addition to synthetic biology to test counter-measure production in space, with the goal to inform and protect astronauts for future Moon missions. We have conducted preliminary tests in preparation for launch to the anticipated South Pole of the Moon, optimizing the biology (strain down-selection, desiccation tolerance, radiation sensitivity) and improving the hardware (including a blue LED to detect the beta-carotene countermeasure product). Our team will discuss these findings in several parts – an overview of the LEIA mission (Mark Settles), adapting flexible CubeSat platforms for deep-space applications (Sergio Santa Maria, Kira Rienecker), developing new technologies to support LEIA ground studies (Chinmayee Govinda Raj), and yeast strain development and hardware testing in preparation for LEIA (presented here).

synthetic biology↗

Lunar Explorer Instrument for space biology Applications (LEIA): An overview of planned science concept of operations

Radiation and reduced gravity pose biological risks to crewed deep space exploration. To better understand deep space radiation biology, the LEIA mission will measure charged particles and fast neutrons as well as yeast growth, metabolic rate, and bioengineered production of carotenoids at the lunar surface. LEIA will be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. The LEIA science concept of operations was developed to isolate radiation and partial gravity from other environmental conditions experienced by the payload. Due to CLPS integration requirements, there will be at least eight months from loading yeast into the payload until activation on the lunar surface. Replicate yeast strains will be loaded in a randomized complete block design to minimize batch differences in desiccation tolerance and positional effects in the microfluidics culture system. Temperature and relative humidity will be controlled throughout integration and flight to maintain yeast viability and to enable measurement of yeast growth parameters within the lunar surface operations timeframe, with the ground control matching environmental conditions where possible. LEIA is co-manifested with the European Space Agency’s PROSPECT mission, which will be operating a drill during yeast growth. Vibration translated through the lunar lander will be mitigated and quantified to account for potential impacts on LEIA optical measurements and yeast growth rate. Total space radiation dose, including the transit exposure from Earth to the Moon, will be measured to obtain more accurate charged particle and fast neutron dose rates on the lunar surface. These radiation data will also yield ground truth radiation dose experienced by the yeast during the mission. Quantifying these environmental factors impacting the LEIA payload will allow more accurate ground control experiments to better isolate the biological responses to radiation and reduced gravity at the lunar surface.

Lunar Surface Mission↗

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen↗

Insulator-based DEP with impedance measurements for analyte detection

Disclosed herein are microfluidic devices for assaying at least one analyte specie in a sample comprising at least one analyte concentration area in a microchannel having insulating structures on or in at least one wall of the microchannel which provide a nonuniform electric field in the presence of an electric field provided by off-chip electrodes; and a pair of passivated sensing electrodes for impedance detection in a detection area. Also disclosed are assay methods and methods of making.

Davalos, Rafael V↗

Microscale fluid transport using optically controlled marangoni effect

Low energy light illumination and either a doped semiconductor surface or a surface-plasmon supporting surface are used in combination for manipulating a fluid on the surface in the absence of any applied electric fields or flow channels. Precise control of fluid flow is achieved by applying focused or tightly collimated low energy light to the surface-fluid interface. In the first embodiment, with an appropriate dopant level in the semiconductor substrate, optically excited charge carriers are made to move to the surface when illuminated. In a second embodiment, with a thin-film noble metal surface on a dispersive substrate, optically excited surface plasmons are created for fluid manipulation. This electrode-less optical control of the Marangoni effect provides re-configurable manipulations of fluid flow, thereby paving the way for reprogrammable microfluidic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Selected applications and processing techniques for LTCC.

Low Temperature Cofired Ceramic has proven itself in microelectronics, microsystems (including microfluidic systems), sensors, RF features, and various non-electronic applications. We will discuss selected applications and the processing associated with those applications. We will then focus on our recent work in the area of EMI shielding using full tape thickness features (FTTF) and sidewall metallization. The FTTF is very effective in applications with -150 dB isolation requirements, but presents obvious processing difficulties in full-scale fabrication. The FTTF forms a single continuous solid wall around the volume to be shielded by using sequential punching and feature-filling. We discuss the material incompatibilities and manufacturing considerations that need to be addressed for such structures and show preliminary implementations.

36 MATERIALS SCIENCE↗

FISH 'N' Chips : a single cell genomic analyzer for the human microbiome.

Uncultivable microorganisms likely play significant roles in the ecology within the human body, with subtle but important implications for human health. Focusing on the oral microbiome, we are developing a processor for targeted isolation of individual microbial cells, facilitating whole-genome analysis without the need for isolation of pure cultures. The processor consists of three microfluidic modules: identification based on 16S rRNA fluorescence in situ hybridization (FISH), fluorescence-based sorting, and encapsulation of individual selected cells into small droplets for whole genome amplification. We present here a technique for performing microscale FISH and flow cytometry, as a prelude to single cell sorting.

59 BASIC BIOLOGICAL SCIENCES↗

Chip-based in situ hybridization for identification of bacteria from the human microbiome.

The emerging field of metagenomics seeks to assess the genetic diversity of complex mixed populations of bacteria, such as those found at different sites within the human body. A single person's mouth typically harbors up to 100 bacterial species, while surveys of many people have found more than 700 different species, of which {approx}50% have never been cultivated. In typical metagenomics studies, the cells themselves are destroyed in the process of gathering sequence information, and thus the connection between genotype and phenotype is lost. A great deal of sequence information may be generated, but it is impossible to assign any given sequence to a specific cell. We seek non-destructive, culture-independent means of gathering sequence information from selected individual cells from mixed populations. As a first step, we have developed a microfluidic device for concentrating and specifically labeling bacteria from a mixed population. Bacteria are electrophoretically concentrated against a photopolymerized membrane element, and then incubated with a specific fluorescent label, which can include antibodies as well as specific or non-specific nucleic acid stains. Unbound stain is washed away, and the labeled bacteria are released from the membrane. The stained cells can then be observed via epifluorescence microscopy, or counted via flow cytometry. We have tested our device with three representative bacteria from the human microbiome: E. coli (gut, Gram-negative), Lactobacillus acidophilus (mouth, Gram-positive), and Streptococcus mutans (mouth, Gram-positive), with results comparable to off-chip labeling techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Gold nanostructures and methods of use

The invention is drawn to novel nanostructures comprising hollow nanospheres and nanotubes for use as chemical sensors, conduits for fluids, and electronic conductors. The nanostructures can be used in microfluidic devices, for transporting fluids between devices and structures in analytical devices, for conducting electrical currents between devices and structure in analytical devices, and for conducting electrical currents between biological molecules and electronic devices, such as bio-microchips.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Micromanifold assembly

A micromanifold for connecting external capillaries to the inlet and/or outlet ports of a microfluidic device can employ a ferrule/capillary assembly that includes: (a) a ferrule comprising an elongated member and having a bore traversing from a proximal end to a distal end of the member, wherein the bore has an inner surface and wherein the distal end of the ferrule has a tapered, threaded exterior surface, and (b) a capillary that is positioned within the bore wherein the capillary's outer surface is in direct contact with the bore's inner surface. No mating sleeve is required for the one-piece ferrule. Alternatively, the capillaries can be bonded to channels that traverse the manifold and therefore obviate the need for a ferrule.

42 ENGINEERING↗

Flow-Solution-Liquid-Solid Growth of Semiconductor Nanowires: A Novel Approach for Controlled Synthesis

Semiconductor nanowires (SC-NWs) have potential applications in diverse technologies from nanoelectronics and photonics to energy harvesting and storage due to their quantum-confined opto-electronic properties coupled with their highly anisotropic shape. Here, we explore new approaches to an important solution-based growth method known as solution-liquid-solid (SLS) growth. In SLS, molecular precursors are reacted in the presence of low-melting metal nanoparticles that serve as molten fluxes to catalyze the growth of the SC-NWs. The mechanism of growth is assumed to be similar to that of vapor-liquid-solid (VLS) growth, with the clear distinctions of being conducted in solution in the presence of coordinating ligands and at relatively lower temperatures (<300 C). The resultant SC-NWs are soluble in common organic solvents and solution processable, offering advantages such as simplified processing, scale-up, ultra-small diameters for quantum-confinement effects, and flexible choice of materials from group III-V to groups II-VI, IV-VI, as well as truly ternary I-III-VI semiconductors as we recently demonstrates. Despite these advantages of SLS growth, VLS offers several clear opportunities not allowed by conventional SLS. Namely, VLS allows sequential addition of precursors for facile synthesis of complex axial heterostructures. In addition, growth proceeds relatively slowly compared to SLS, allowing clear assessments of growth kinetics. In order to retain the materials and processing flexibility afforded by SLS, but add the elements of controlled growth afforded by VLS, we transformed SLS into a flow based method by adapting it to synthesis in a microfluidic system. By this new method - so-called 'flow-SLS' (FSLS) - we have now demonstrated unprecedented fabrication of multi-segmented SC-NWs, e.g., 8-segmented CdSe/ZnSe defined by either compositionally abrupt or alloyed interfaces as a function of growth conditions. In addition, we have studied growth rates as a function of catalyst size/SC-NW diameter and shown for the first time that SLS is governed by Gibbs-Thomson effects. Lastly, from an applications standpoint, we report growth of SC-NWs from a range of substrates, including ITO-coated glass for fabrication of hybrid photovoltaic devices, comparing these to their quasi zero-dimensional quantum-dot counterparts.

36 MATERIALS SCIENCE↗

Multiscale Modeling of Hematologic Disorders

Parasitic infectious diseases and other hereditary hematologic disorders are often associated with major changes in the shape and viscoelastic properties of red blood cells (RBCs). Such changes can disrupt blood flow and even brain perfusion, as in the case of cerebral malaria. Modeling of these hematologic disorders requires a seamless multiscale approach, where blood cells and blood flow in the entire arterial tree are represented accurately using physiologically consistent parameters. In this chapter, we present a computational methodology based on dissipative particle dynamics (DPD) which models RBCs as well as whole blood in health and disease. DPD is a Lagrangian method that can be derived from systematic coarse-graining of molecular dynamics but can scale efficiently up to small arteries and can also be used to model RBCs down to spectrin level. To this end, we present two complementary mathematical models for RBCs and describe a systematic procedure on extracting the relevant input parameters from optical tweezers and microfluidic experiments for single RBCs. We then use these validated RBC models to predict the behavior of whole healthy blood and compare with experimental results. The same procedure is applied to modeling malaria, and results for infected single RBCs and whole blood are presented.

60 APPLIED LIFE SCIENCES↗

Single-molecule mobility in confined and crowded femtoliter chambers

The effects of increased crowding and confinement on the mobility of individual fluorescent molecules were studied using Fluorescence Correlation Spectroscopy (FCS) in a microfluidic device with sealable femtoliter-volume chambers, and compared to three dimensional stochastic Monte Carlo simulations. When crowding and the degree of confinement were increased simultaneously, extended correlation times of fluorescent intensity fluctuations were observed with FCS compared to varying either crowding or confinement alone. Both experimental data and simulation suggest these extended correlation times were due to increased fluorophore adsorption-desorption events at the chamber lid in the presence of crowders. The data in increasingly confined and crowded chambers described here captures some of the salient features of crowding in cell-like environments.

Collier, Pat↗

Dielectrophoresis device and method having nonuniform arrays for manipulating particles

Microfluidic devices according to embodiments of the present invention include an inlet port, an outlet port, and a channel or chamber having a non-uniform array of insulating features on one or more surfaces. Electrodes are provided for generation of a spatially non-uniform electric field across the array. A voltage source, which may be an A.C. and/or a D.C. voltage source may be coupled to the electrodes for the generation of the electric field.

47 OTHER INSTRUMENTATION↗