Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apparatus and method for heating a material in a transparent ampoule

An improved process for heating a material within a fused silica ampoule by radiation through the wall of the ampoule, while simultaneously passing a cooling gas around the ampoule is described. The radiation passes through a screen of fused silica so as to remove those components capable of directly heating the silica, therby increasing the temperature of the material within the ampoule above the strain point of the ampoule, while maintaining the exterior of the ampoule cool enough to prevent rupturing the amp.

Holland, L. R.↗

Sensitization of Tumor to {sup 212}Pb Radioimmunotherapy by Gemcitabine Involves Initial Abrogation of G2 Arrest and Blocked DNA Damage Repair by Interference With Rad51

Purpose: To elucidate the mechanism of the therapeutic efficacy of targeted α-particle radiation therapy using {sup 212}Pb-TCMC-trastuzumab together with gemcitabine for treatment of disseminated peritoneal cancers. Methods and Materials: Mice bearing human colon cancer LS-174T intraperitoneal xenografts were pretreated with gemcitabine, followed by {sup 212}Pb-TCMC-trastuzumab and compared with controls. Results: Treatment with {sup 212}Pb-TCMC-trastuzumab increased the apoptotic rate in the S-phase-arrested tumors induced by gemcitabine at earlier time points (6 to 24 hours). {sup 212}Pb-TCMC-trastuzumab after gemcitabine pretreatment abrogated G2/M arrest at the same time points, which may be associated with the inhibition of Chk1 phosphorylation and, in turn, cell cycle perturbation, resulting in apoptosis. {sup 212}Pb-TCMC-trastuzumab treatment after gemcitabine pretreatment caused depression of DNA synthesis, DNA double-strand breaks, accumulation of unrepaired DNA, and down-regulation of Rad51 protein, indicating that DNA damage repair was blocked. In addition, modification in the chromatin structure of p21 may be associated with transcriptionally repressed chromatin states, indicating that the open structure was delayed at earlier time points. Conclusion: These findings suggest that the cell-killing efficacy of {sup 212}Pb-TCMC-trastuzumab after gemcitabine pretreatment may be associated with abrogation of the G2/M checkpoint, inhibition of DNA damage repair, and chromatin remodeling.

60 APPLIED LIFE SCIENCES↗

Accurate Gene Expression-Based Biodosimetry Using a Minimal Set of Human Gene Transcripts

Purpose: Rapid and reliable methods for conducting biological dosimetry are a necessity in the event of a large-scale nuclear event. Conventional biodosimetry methods lack the speed, portability, ease of use, and low cost required for triaging numerous victims. Here we address this need by showing that polymerase chain reaction (PCR) on a small number of gene transcripts can provide accurate and rapid dosimetry. The low cost and relative ease of PCR compared with existing dosimetry methods suggest that this approach may be useful in mass-casualty triage situations. Methods and Materials: Human peripheral blood from 60 adult donors was acutely exposed to cobalt-60 gamma rays at doses of 0 (control) to 10 Gy. mRNA expression levels of 121 selected genes were obtained 0.5, 1, and 2 days after exposure by reverse-transcriptase real-time PCR. Optimal dosimetry at each time point was obtained by stepwise regression of dose received against individual gene transcript expression levels. Results: Only 3 to 4 different gene transcripts, ASTN2, CDKN1A, GDF15, and ATM, are needed to explain ≥0.87 of the variance (R{sup 2}). Receiver-operator characteristics, a measure of sensitivity and specificity, of 0.98 for these statistical models were achieved at each time point. Conclusions: The actual and predicted radiation doses agree very closely up to 6 Gy. Dosimetry at 8 and 10 Gy shows some effect of saturation, thereby slightly diminishing the ability to quantify higher exposures. Analyses of these gene transcripts may be advantageous for use in a field-portable device designed to assess exposures in mass casualty situations or in clinical radiation emergencies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emulation of radiation transport in 3D stochastic media using 1D planar Monte Carlo stochastic media radiation transport algorithms

A subset of stochastic media radiation transport problems involves those in which radiation is incident on a thin slab of stochastic material. Particle tracking in 3D for such problems is expensive, and 1D planar models lack accuracy because they only allow the material to change in one dimension. Therefore, we propose dimensional emulation, which through a slight modification allows existing 1D planar geometry stochastic media radiation transport models to reproduce results from the equivalent 3D models by allowing the material to change in all three dimensions, reproducing the fidelity of the 3D model for the low computational cost of the 1D planar model. In this work, we apply dimensional emulation to three Monte Carlo stochastic media radiation transport models: Chord Length Sampling (CLS), the Local Realization Preserving method (LRP), and a variant of Conditional Point Sampling (CoPS). For a common Markovian benchmark set, the 3D emulation variants of these algorithms are numerically verified to reproduce the results of the 3D variants within statistics while running 1.3 to 2 times faster in the implementation within Sandia National Laboratories open-source research code PlaybookMC. The 3D emulation variants are also shown to yield a 72%–92% reduction in error for the thin slab problems in comparison to the 1D benchmark. As a result, the 3D emulation variant of CLS and CoPS-1 are shown to reproduce 3D CLS results that were used to approximate results for a 3D spherical inclusion geometry benchmark set.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-propagating high-temperature synthesis for compound thermoelectrics and new criterion for combustion processing

The existing methods of synthesis of thermoelectric (TE) materials remain constrained to multi-step processes that are time and energy intensive. Here we demonstrate that essentially all compound thermoelectrics can be synthesized in a single-phase form at a minimal cost and on the timescale of seconds using a combustion process called self-propagating high-temperature synthesis. We illustrate this method on Cu2Se and summarize key reaction parameters for other materials. We propose a new empirically based criterion for sustainability of the combustion reaction, where the adiabatic temperature that represents the maximum temperature to which the reacting compact is raised as the combustion wave passes through, must be high enough to melt the lower melting point component. Our work opens a new avenue for ultra-fast, low-cost, large-scale production of TE materials, and provides new insights into combustion process, which greatly broaden the scope of materials that can be successfully synthesized by this technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved high temperature radiation damage tolerance in a three-phase ceramic with heterointerfaces

Abstract Radiation damage tolerance for a variety of ceramics at high temperatures depends on the material’s resistance to nucleation and growth of extended defects. Such processes are prevalent in ceramics employed for space, nuclear fission/fusion and nuclear waste environments. This report shows that random heterointerfaces in materials with sub-micron grains can act as highly efficient sinks for point defects compared to grain boundaries in single-phase materials. The concentration of dislocation loops in a radiation damage-prone phase (Al 2 O 3 ) is significantly reduced when Al 2 O 3 is a component of a composite system as opposed to a single-phase system. These results present a novel method for designing exceptionally radiation damage tolerant ceramics at high temperatures with a stable grain size, without requiring extensive interfacial engineering or production of nanocrystalline materials.

36 MATERIALS SCIENCE↗

N-derived signals in the x-ray photoelectron spectra of N-doped anatase TiO{sub 2}

The plasma-assisted molecular beam epitaxial anatase TiO{sub 2-x}N{sub x} (x<0.3) films were chosen to investigate the N-derived variation in the x-ray photoelectron spectroscopy (XPS). With increasing nitrogen concentration, the small chemical shift and the shoulder of the main peak emerge in the N 1s, O 1s, or Ti 2p{sub 3/2} core level spectra. In combination with the experimental results obtained from x-ray diffraction and atomic force microscopy, the variations in the spectra could be ascribed to the microstructural distortion. This distortion, induced by the N{sup 3-} substitution for lattice O{sup 2-}, could slightly decrease the average ionicity of the Ti-O (or N) bonds. In addition, the other N 1s features (at 399.8 and 401.8 eV) and the oxygen vacancy are also discussed. For the N-doped TiO{sub 2}, this work introduces a correlation between the microstructural properties and the XPS signals.

36 MATERIALS SCIENCE↗

Postdeposition annealing induced transition from hexagonal Pr{sub 2}O{sub 3} to cubic PrO{sub 2} films on Si(111)

Films of hexagonal praseodymium sesquioxide (h-Pr{sub 2}O{sub 3}) were deposited on Si(111) by molecular beam epitaxy and thereafter annealed in 1 atm oxygen at different temperatures, ranging from 100 to 700 deg. C. The films of the samples annealed at 300 deg. C or more were transformed to PrO{sub 2} with B-oriented Fm3m structure, while films annealed at lower temperatures kept the hexagonal structure. The films are composed of PrO{sub 2} and PrO{sub 2-d}elta species, which coexist laterally and are tetragonally distorted due to the interaction at the interface between oxide film and Si substrate. Compared to PrO{sub 2}, PrO{sub 2-d}elta has the same cubic structure but with oxygen vacancies. The oxygen vacancies are partly ordered and increase the vertical lattice constant of the film, whereas the lateral lattice constant is almost identical for both species and on all samples. The latter lattice constant matches the lattice constant of the originally crystallized hexagonal praseodymium sesquioxide. That means that no long range reordering of the praseodymium atoms takes place during the phase transformation.

36 MATERIALS SCIENCE↗

Deep levels induced by reactive ion etching in n- and p-type 4H-SiC

In this study, the authors investigate deep levels, which are induced by reactive ion etching (RIE) of n-type/p-type 4H-SiC, by deep level transient spectroscopy (DLTS). The capacitance of a Schottky contact fabricated on as-etched p-type SiC is abnormally small due to compensation or deactivation of acceptors extending to a depth of {approx}14 {mu}m, which is nearly equal to the epilayer thickness. The value of the capacitance can recover to that of a Schottky contact on as-grown samples after annealing at 1000 deg. C. However, various kinds of defects, IN2 (E{sub C}-0.30 eV), EN (E{sub C}-1.6 eV), IP1 (E{sub V}+0.30 eV), IP2 (E{sub V}+0.39 eV), IP4 (HK0: E{sub V}+0.72 eV), IP5 (E{sub V}+0.85 eV), IP7 (E{sub V}+1.3 eV), and EP (E{sub V}+1.4 eV), remain at a high concentration (average of total defect concentration in the region ranging from 0.3 {mu}m to 1.0 {mu}m:{approx}5x10{sup 14} cm{sup -3}) even after annealing at 1000 deg. C. The concentration of all these defects generated by RIE, except for the IP4 (HK0) center, remarkably decreases by thermal oxidation. In addition, the HK0 center can also be reduced significantly by a subsequent annealing at 1400 deg. C in Ar.

36 MATERIALS SCIENCE↗

Epitaxial EuO thin films on GaAs

We demonstrate the epitaxial growth of EuO on GaAs by reactive molecular beam epitaxy. Thin films are grown in an adsorption-controlled regime with the aid of an MgO diffusion barrier. Despite the large lattice mismatch, it is shown that EuO grows well on MgO(001) with excellent magnetic properties. Epitaxy on GaAs is cube-on-cube and longitudinal magneto-optic Kerr effect measurements demonstrate a large Kerr rotation of 0.57 deg., a significant remanent magnetization, and a Curie temperature of 69 K.

36 MATERIALS SCIENCE↗

Major deep levels with the same microstructures observed in n-type 4H-SiC and 6H-SiC

Major deep levels observed in as-grown and irradiated n-type 4H-SiC and 6H-SiC epilayers have been investigated. After low-energy electron irradiation, by which only carbon atoms are displaced, five traps, EH1 (E{sub C}-0.36 eV), Z{sub 1}/Z{sub 2} (E{sub C}-0.65 eV), EH3 (E{sub C}-0.79 eV), EH5 (E{sub C}-1.0 eV), and EH6/7 (E{sub C}-1.48 eV), were detected in 4H-SiC and four traps, E{sub 1}/E{sub 2} (E{sub C}-0.45 eV), RD{sub 5} (E{sub C}-0.57 eV), ES (E{sub C}-0.80 eV), and R (E{sub C}-1.25 eV), were detected in 6H-SiC. The Z{sub 1}/Z{sub 2}, EH6/7 centers in 4H-SiC and the E{sub 1}/E{sub 2}, R centers in 6H-SiC exhibit common features as follows: their generation rates by the e{sup -}-irradiation were almost the same each other, their concentrations were not changed by heat treatments up to 1500 deg. C, and they showed very similar annealing behaviors at elevated temperatures. Furthermore, these defect centers were almost eliminated by thermal oxidation. Taking account of the observed results and the energy positions, the authors suggest that the Z{sub 1}/Z{sub 2} center in 4H-SiC corresponds to the E{sub 1}/E{sub 2} center in 6H-SiC, and the EH6/7 center in 4H-SiC to the R center in 6H-SiC, respectively. Since the concentrations of these four centers are almost the same for as-grown, electron-irradiated, annealed, and oxidized samples, these centers will contain a common intrinsic defect, most likely carbon vacancy. The authors also observed similar correspondence for other thermally unstable traps in 4H-SiC and 6H-SiC.

36 MATERIALS SCIENCE↗

On the mobility and contact resistance evaluation for transistors based on MoS{sub 2} or two-dimensional semiconducting atomic crystals

Contact resistance (R{sub c}) can substantially obscure the extracted mobility based on standard transconductance or two-point conductance measurements of field-effect devices especially for low density of states materials such as MoS{sub 2} or similar atomic crystals. Currently, there exists a pressing need for a routine technique that can decouple mobility extraction from R{sub c}. By combining experiments and analysis, we show that the Y-function method offers a robust route for evaluating the low-field mobility, threshold voltage and R{sub c} even when the contact is a Schottky-barrier as is common in two-dimensional transistors. In addition, an independent modified transfer length method evaluation corroborates the Y-function analysis.

36 MATERIALS SCIENCE↗

Measurement of crack length in width tapered beam experiments

The width tapered beam method for measuring fracture toughness has been contemplated for use in measuring the adhesion of photovoltaic materials, is promoted by it being a viable method for use directly on modules rather than to engineered test specimens. However, precise determination of crack length is often difficult as failure often involves tendril formation, cavitation voids, and other plastic deformation at the crack front in addition to obfuscation by opaque materials. Because fracture energy varies as the square of crack length, imprecise crack tip length results in large measurement uncertainties. In this work, we develop a method to estimate the crack tip length using the relationship between the applied force and the displacement of the load frame. The crack tip is determined for every data point and can be defined from a calibration curve related to the amount of energy put into the beam, or from a theoretically idealized estimation. Once a calibration curve is set up and the equations programmed, the fracture energy as a function of position on the newly formed crack interface can be accurately estimated. The test additionally provides much easier analysis and insight into the joint failure through more precise knowledge of fracture toughness at each de-bonded area.

42 ENGINEERING↗

Effect of current injection into thin-film Josephson junctions

New thin-film Josephson junctions have recently been tested in which the current injected into one of the junction banks governs Josephson phenomena. One thus can continuously manage the phase distribution at the junction by changing the injected current. Our method of calculating the distribution of injected currents is also proposed for a half-infinite thin-film strip with source-sink points at arbitrary positions at the film edges. The strip width W is assumed small relative to Λ=2λ 2 /d;λ is the bulk London penetration depth of the film material and d is the film thickness.

42 ENGINEERING↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct determination of mode-projected electron-phonon coupling in the time domain

Ultrafast spectroscopies have become an important tool for elucidating the microscopic description and dynamical properties of quantum materials. In particular, by tracking the dynamics of nonthermal electrons, a material’s dominant scattering processes can be revealed. In this paper, we present a method for extracting the electron-phonon coupling strength in the time domain, using time- and angle-resolved photoemission spectroscopy (TR-ARPES). This method is demonstrated in graphite, where we investigate the dynamics of photoinjected electrons at the $\overline{K}$ point, detecting quantized energy-loss processes that correspond to the emission of strongly coupled optical phonons. We show that the observed characteristic time scale for spectral weight transfer mediated by phonon-scattering processes allows for the direct quantitative extraction of electron-phonon matrix elements for specific modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated Process Model Utilization and Development for Inertial Fusion Energy

This CRADA between LLNS and Longview Fusion Energy Systems utilized a modernized LLNL Integrated Process Model (IPM) to assess technoeconomic viability and power plant configurations for Inertial Fusion Energy (IFE). During the collaboration period, a streamlined IPM model was produced by LLNL, which consolidated a combination of 3 models under one file. Additionally, obsolete parameters were removed and parameters available for trade space analysis were organized in a user-friendly fashion on the front interface. Gain scaling curves were discussed and analyzed in the framework of the IPM. Additional updates were made to account for cost scaling to today's dollars using an average inflation rate. Heat transfer material costing was updated using a ground up approach with public vendor data. Further levelized cost of electricity (LCOE) methods and models were discussed and reviewed for applicability to the IPM. Prior published literature on optical scaling was also discussed. Moreover, as part of this CRADA, the Participant developed a fusion technology development roadmap and point designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗