Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Durability Testing of a Low‐Temperature Sintering Bi–Si–Zn Oxide Glass Composite Material (GCM) 129 I Waste Form

The capture and safe storage of radiological iodine ( 129 I) from nuclear fuel reprocessing is of concern due to its long half‐life and potential mobility in the environment. The development of durable waste forms in which to store captured iodine requires materials that are both compatible with the iodine capture phases and durable to repository environments. To that end, Sandia is developing a low‐temperature sintering Bi–Si–Zn oxide glass composite material (GCM) waste form and herein presents results of durability testing. Furthermore, durability studies were extended to both the occluded iodine capture material Ag‐Zeolite (Mordenite, MOR) as well as the GCM, synthesized with compositional variations including: amount of Ag flake added, AgI‐MOR particle size in the GCM, and mass loading of I within the AgI‐MOR. Product consistency test (PCT‐B), chemical durability (MCC‐1) tests, and single‐pass flow‐through (SPFT) tests, were performed on both the individual components of the GCM and the completed GCMs. Durability tests indicate low GCM dissolution rates (<10 −3 g/m 2 ·d) across wide variable ranges including: pH, AgI‐MOR loading, I loading, and AgI‐MOR particle size. Results indicate that the Bi–Si–Zn oxide glass matrix sharply limits the release of iodine from the otherwise relatively fast degrading AgI‐MOR getter material. Furthermore, the formation of an amorphous AgI phase during sintering of the GCM results in the limitation of iodine release during waste form degradation. Durability of GCM and release rates approximate those of established nuclear waste glasses, or analogues such as basaltic glass. This suggests that the Bi–Si–Zn GCM is a viable candidate as a repository iodine waste form.

Mowry, Curtis D.↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

OC6 Phase I: Investigating the underprediction of low-frequency hydrodynamic loads and responses of a floating wind turbine

Phase I of the OC6 project is focused on examining why offshore wind design tools underpredict the response (loads/motion) of the OC5-DeepCwind semisubmersible at its surge and pitch natural frequencies. Previous investigations showed that the underprediction was primarily related to nonlinear hydrodynamic loading, so two new validation campaigns were performed to separately examine the different hydrodynamic load components. In this paper, we validate a variety of tools against this new test data, focusing on the ability to accurately model the low-frequency loads on a semisubmersible floater when held fixed under wave excitation and when forced to oscillate in the surge direction. However, it is observed that models providing better load predictions in these two scenarios do not necessarily produce a more accurate motion response in a moored configuration.

17 WIND ENERGY↗

Spallation Neutron Source Cryogenic Test Facility Horizontal Test Apparatus Operation

The Spallation Neutron Source (SNS) has built Superconducting Radio Frequency (SRF) processing and testing facilities to support improvement programs and future upgrades. The Cryogenic Test Facility (CTF) system is capable of delivering liquid helium at 4.5K to different test apparatus in support of SRF testing. This paper describes the final stages of fabrication, commissioning and the initial operation of the Horizontal Test Apparatus (HTA). The HTA allows for cold testing of single jacketed medium-beta or high-beta SRF cavities. Heat loads, capacities, and other performance data collected during operation will be presented. Cavity testing lifecycle for plasma processing research and development will be discussed. System changes to allow for 2K helium operation in the HTA will also be addressed.

Afanador, Ralph↗

DEVELOPMENT OF THE LARGE-BORE POWDER GUN FOR THE NEVADA TEST SITE

Plate-impact experiments on single stage guns provide very planar loading conditions suitable for studying complex phenomena such as phase transitions and material strength, and provide important data useful for constraining and validating predictive models. The objective of the current work was to develop a large-bore (3.5'' or greater) powder gun capable of accelerating projectiles to moderately high velocities (greater than 2.25 km/s) for impact experiments at Nevada Test Site. This gun will span a performance gap between existing gun facilities and provide a means of examining phenomena over a wide range of stresses and time-scales. Advantages of the large-bore gun include the capability to load multiple samples simultaneously, the use of large diameter samples that significantly extend the time duration of the experiment, and minimal tilt (no bow). This new capability required the development of a disposable confinement system that used an explosively driven closure method to prevent contamination from moving up into the gun system. Experimental results for both the gun system and the explosive valve are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technology Solutions Case Study: Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes, Tucson, Arizona and Chico, California

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

air conditioning↗

Plug Load Management System Field Study

In 2018, NREL performed a demonstration of the IBIS InteliNetwork(TM) plug load management system, which includes: intelligent socket devices, which plug into existing electrical outlets and collect energy usage information; a gateway, which manages communication between the intelligent sockets and the PLM cloud service; and a PLM network, which is a cloud-based measurement and control network for the entire system. Two retail stores served as the field study sites. The PLM system was found to be effective at reducing plug load energy use, with a projected annual plug load reduction of 11% and 18% at the test locations. Retail staff reported that the hardware was easy to use, but no one used the online data management system, intended to analyze and control the hardware. This PLM solution shows promise as an effective means to monitor, control, and reduce plug load energy use, but the economics of the system need to be improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Oxygen Evolution Reaction Catalysts for Cell Reversal and Start/Stop Tolerance in Fuel Cells

Minute amounts of ruthenium and iridium on platinum nanostructured thin films have been evaluated in an effort to reduce carbon corrosion and Pt dissolution during transient conditions in proton exchange membrane fuel cells. Electrochemical tests showed the catalysts had a remarkable oxygen evolution reaction (OER) activity, even greater than that of bulk, metallic thin films. Stability tests within a fuel cell environment showed that rapid Ru dissolution could be managed with the addition of Ir. Membrane electrode assemblies containing a Ru to Ir atomic ratio of 1:9 were evaluated under startup/shutdown and cell reversal conditions for OER catalyst loadings ranging from 1 to 10 g/cm2. These tests affirmed that electrode potentials can be controlled through the addition of OER catalysts without impacting the oxygen reduction reaction on the cathode or the hydrogen oxidation reaction on the anode. The morphology and chemical structure of the thin OER layers were characterized by scanning transmission electron microscopy and X-ray photoelectron spectroscopy in an effort to establish a correlation between interfacial properties and electrochemical behavior.

Atanasoski, Radoslav↗

Fast Primary Frequency Response using Coordinated DER and Flexible Loads: Framework and Residential-scale Demonstration

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (~8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRIPOLI-4 neutronics calculations for IAEA-CRP benchmark of CEFR start-up tests using new libraries JEFF-3.3 and ENDF/B-VIII

Sodium-cooled Fast Reactors (SFR) are one of the promising Generation IV fast reactors. The China Experimental Fast Reactor (CEFR) is a 65 MWth pool-type SFR with a high neutron leakage core using high enriched uranium oxide fuel. The CEFR start-up tests in 2010 consist of series of neutronics experiments. Essential experimental data are available from the 2018 IAEA-CEFR-CRP benchmark document and useful for the validation of neutron transport codes and nuclear data libraries. The TRIPOLI-4 Monte Carlo transport code is a general-purpose neutronics code using continuous-energy nuclear data libraries. It has a rich validation database covering different computational and experimental benchmark data sets to assure the accuracy and credibility of numerical studies. Previous TRIPOLI-4 SFR core physics calculations used mainly MOX fuels. SFR control rod worth studies with TRIPOLI-4 were mainly on big-size cores. To test the modeling capability of TRIPOLI-4 on fuel loading patterns and on variable control rods positions for SFRs and to check recent nuclear data libraries, it is interesting to investigate the CEFR start-up tests in this work, including core states from subcritical to supercritical, control rods and rod group worth, point kinetics parameters, and radial foil activation measurements. TRIPOLI-4 calculation results using new data libraries JEFF-3.3, ENDF/B-VIII, and those of ENDF/B-VII.1 for different CEFR core states are reported here. By means of different options of TRIPOLI-4, control-rod SAs reactivity worth, point kinetics parameters, and radial {sup 237}Np(n,f) fission rate distribution were successfully evaluated. Both ENDF/B-VIII and JEFF-3.3 nuclear data libraries provided reliable results with a difference of 170 +/- 11 pcm in k{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Introducing CGOLS: The Cholla Galactic Outflow Simulation Suite

Here, we present the Cholla Galactic OutfLow Simulations (CGOLS) suite, a set of extremely high resolution global simulations of isolated disk galaxies designed to clarify the nature of multiphase structure in galactic winds. Using the GPU-based code Cholla, we achieve unprecedented resolution in these simulations, modeling galaxies over a 20 kpc region at a constant resolution of 5 pc. The simulations include a feedback model designed to test the effects of different mass- and energy-loading factors on galactic outflows over kiloparsec scales. In addition to describing the simulation methodology in detail, we also present the results from an adiabatic simulation that tests the frequently adopted analytic galactic wind model of Chevalier & Clegg. Our results indicate that the Chevalier & Clegg model is a good fit to nuclear starburst winds in the nonradiative region of parameter space. Finally, we investigate the role of resolution and convergence in large-scale simulations of multiphase galactic winds. While our largest-scale simulations show convergence of observable features like soft X-ray emission, our tests demonstrate that simulations of this kind with resolutions greater than 10 pc are not yet converged, confirming the need for extreme resolution in order to study the structure of winds and their effects on the circumgalactic medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Primary Frequency Response Using Coordinated DER and Flexible Loads: Framework and Residential-Scale Demonstration: Preprint

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (about 8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Macrocrack propagation in concrete specimens under sustained loading: Study of the physical mechanisms

This study presents a series of 4-point bending tests performed to describe the delayed behavior of unreinforced pre-cracked beams under low, moderate and high sustained loading levels. The deflection creep rate, the failure time and the load level were assessed. A linear relation, in a semi-log scale, was found for the deflection creep rate at high load levels. In addition, a linear relation, in a log–log scale, between the secondary deflection creep rate and failure time was observed. Besides, it was shown that the secondary creep deflection rate increases with the sustained loading level and the macrocrack propagation rate when macrocrack propagation occurs during the sustained loading. Physical mechanisms are proposed to explain these results and may be summarized as follows: the delayed behavior of an unreinforced cracked concrete specimen under sustained loading is mainly due to the cracking evolution, thus the creation of microcracks and/or the propagation of a macrocrack.

36 MATERIALS SCIENCE↗

MATRIX 1 RESULTS OF THE FY07 ENHANCED DOE HIGH-LEVEL WASTE MELTER THROUGHPUT STUDIES AT SRNL

High-level waste (HLW) throughput (i.e., the amount of waste processed per unit time) is a function of two critical parameters: waste loading (WL) and melt rate. For the Waste Treatment and Immobilization Plant (WTP) at the Hanford Site and the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), increasing HLW throughput would significantly reduce the overall mission life cycle costs for the Department of Energy (DOE). It has been proposed that a team of glass formulation and processing experts at the Pacific Northwest National Laboratory (PNNL), Savannah River National Laboratory (SRNL), and Vitreous State Laboratory (VSL) at Catholic University of America develop a systematic approach to increase HLW throughput (by increasing WL with minimal or positive impacts on melt rate). Programmatically, this task is aimed at proof-of-principle testing and the development of tools to improve waste loading and melt rate, which will lead to higher waste throughput. The following four specific tasks have been proposed to meet this programmatic objective: (1) Integration and Oversight, (2) Crystal Accumulation Modeling (led by PNNL)/Higher Waste Loading Glasses (led by SRNL), (3) Melt Rate Evaluation and Modeling, and (4) Melter Scale Demonstrations. The details of these tasks can be found in the associated task plan WSRC-STI-2007-00483. The current study is focused on Task 2 (crystal accumulation modeling and higher waste loading glasses) and involves glass formulation and physical property testing by both PNNL and SRNL (as defined in the PNNL and SRNL test plans). The intent of this report is to document the chemical composition and Product Consistency Test (PCT) results and statistical analysis of PNNL's Test Matrix 1 glasses. Note that this document is only a compilation of the data collected by SRNL for PNNL's glasses in support of this task and no conclusions will be drawn.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗