Advanced high temperature instrumentation for hot section research applications

Programs to develop research instrumentation for use in turbine engine hot sections are described. These programs were initiated to provide improved measurements capability as support for a multidisciplinary effort to establish technology leading to improved hot section durability. Specific measurement systems described here include heat flux sensors, a dynamic gas temperature measuring system, laser anemometry for hot section applications, an optical system for viewing the interior of a combustor during operation, thin film sensors for surface temperature and strain measurements, and high temperature strain measuring systems. The paper will describe the state of development of these sensors and measuring systems and, in some cases, will show examples of measurements made with this instrumentation. The paper covers work done at the NASA Lewis Research Center and at various contract and grant facilities.

Englund, D. R.↗

Advanced high temperature instrument for hot section research applications

Programs to develop research instrumentation for use in turbine engine hot sections are described. These programs were initiated to provide improved measurements capability as support for a multidisciplinary effort to establish technology leading to improved hot section durability. Specific measurement systems described here include heat flux sensors, a dynamic gas temperature measuring systems, laser anemometry for hot section applications, an optical system for viewing the interior of a combustor during operation. Thin film sensors for surface temperature and strain measurements, and high temperature strain measuring systems. The paper will describe the state of development of these sensors and measuring systems and, i n some cases, will show examples of measurements made with this instrumentation. The paper covers work done a t the NASA Lewis Research Center and at various contract and grant facilities.

D R Englund↗

Beam rider for an Articulated Robot Manipulator (ARM) accurate positioning of long flexible manipulators

Laser beam positioning and beam rider modules were incorporated into the long hollow flexible segment of an articulated robot manipulator (ARM). Using a single laser beam, the system determined the position of the distal ARM endtip, with millimetric precision, in six degrees of freedom, at distances of up to 10 meters. Preliminary designs, using space rated technology for the critical systems, of a two segmented physical ARM, with a single and a dual degree of freedom articulation, were developed, prototyped, and tested. To control the positioning of the physical ARM, an indirect adaptive controller, which used the mismatch between the position of the laser beam under static and dynamic conditions, was devised. To predict the behavior of the system and test the concept, a computer simulation model was constructed. A hierarchical artificially intelligent real time ADA operating system program structure was created. The software was designed for implementation on a dedicated VME bus based Intel 80386 administered parallel processing multi-tasking computer system.

Malachowski, M. J.↗

Research Lasers and Air Traffic Safety: Issues, Concerns and Responsibilities of the Research Community

The subject of outdoor use of lasers relative to air traffic has become a diverse and dynamic topic. During the past several decades, the use of lasers in outdoor research activities have increased significantly. Increases in the outdoor use of lasers and increases in air traffic densities have changed the levels of risk involved. To date there have been no documented incidents of air traffic interference from research lasers; however, incidents involving display lasers have shown a marked increase. As a result of the national response to these incidents, new concerns over lasers have arisen. Through the efforts of the SAE G-10T Laser Safety Hazards Subcommittee and the ANSI Z136.6 development committee, potential detrimental effects to air traffic beyond the traditional eye damage concerns have been identified. An increased emphasis from the Federal Aviation Administration (FAA), the Center for Devices and Radiological Hazards (CDRH), and the National Transportation Safety Board (NTSB) along with increased concern by the public have resulted in focused scrutiny of potential hazards presented by lasers. The research community needs to rethink the traditional methods of risk evaluation and application of protective measures. The best current approach to assure adequate protection of air traffic is the application of viable hazard and risk analysis and the use of validated protective measures. Standards making efforts and regulatory development must be supported by the research community to assure that reasonable measures are developed. Without input, standards and regulations can be developed that are not compatible with the needs of the research community. Finally, support is needed for the continued development and validation of protective measures.

Nessler, Phillip J., Jr.↗

Application of Three-Component PIV to a Hovering Rotor Wake

The key to accurate predictions of rotorcraft aerodynamics, acoustics, and dynamics lies in the accurate representation of the rotor wake. The vortical wake computed by rotorcraft CFD analyses typically suffer from numerical dissipation before the first blade passage. With some a priori knowledge of the wake trajectory, grid points can be concentrated along the trajectory to minimize the dissipation. Comprehensive rotorcraft analyses based on lifting-line theory rely on classical vortex models and/or semi-empirical information about the tip vortex structure. Until the location, size, and strength of the trailed tip vortex can be measured over a range of wake ages, the analyses will continue to be adjusted on a trial and error basis in order to correctly predict blade airloads, acoustics, dynamics, and performance. Using the laser light sheet technique, tip vortex location can be acquired in a straightforward manner. Measuring wake velocities and vortex core size, however, has been difficult and tedious using point-measurement techniques such as laser velocimetry. Recently, the Particle Image Velocimetry (PIV) technique has proven to be an efficient method for acquiring velocity measurements over relatively large areas and volumes of a rotor wake. The work reported to date, however, has been restricted to 2-component velocity measurements of the rotor wake. Three-component velocity measurements of a hovering rotor wake were acquired at NASA Ames Research Center in May 1999. This experiment represents a major step toward understanding the detailed structure of a rotor wake. This paper will focus primarily on the experimental technique used in acquiring this data. The accuracy and limitations of the current technique will also be discussed. Representative velocity field measurements will be included.

Yamauchi, Gloria K.↗

The GEODYN Precision Orbit Determination Software

GEODYN-II is NASA’s state-of-the-art geodetic parameter estimation and precision orbit determination (POD) system, developed at Goddard Space Flight Center and maintained within the Geodesy and Geophysics Laboratory. GEODYN supports POD and geodetic parameter estimation for both Earth orbiting and planetary/planetary body missions. It implements a comprehensive set of high-fidelity force models for integrating satellite orbits. GEODYN supports approximately 100 measurement types, including support for Global Navigation Satellite System (GNSS), Satellite Laser Ranging (SLR), Doppler Orbitography and Radio positioning Integrated by Satellite (DORIS), Very Long Base Interferometry (VLBI), landmark (camera data), landmark crossovers, radar and laser direct altimeter ranging, and dynamic altimetry crossovers.

Joseph B Nicholas↗

Using strong electromagnetic fields to control x-ray processes.

Exploration of a new ultrafast-ultrasmall frontier in atomic and molecular physics has begun. Not only is is possible to control outer-shell electron dynamics with intense ultrafast optical lasers, but now control of inner-shell processes has become possible by combining intense infrared/optical lasers with tunable sources of X-ray radiation. This marriage of strong-field laser and X-ray physics has led to the discovery of methods to control reversibly resonant X-ray absorption in atoms and molecules on ultrafast timescales. Using a strong optical dressing field, resonant X-ray absorption in atoms can be markedly suppressed, yielding an example of electromagnetically induced transparency for x rays. Resonant X-ray absorption can also be controlled in molecules using strong non-resonant, polarized laser fields to align the framework of a molecule, and therefore its unoccupied molecular orbitals to which resonant absorption occurs. At higher laser intensities, ultrafast field ionization produces an irreversible change in X-ray absorption. Finally, the advent of X-ray free electron lasers enables first exploration of non-linear X-ray processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Insights into the laser-assisted photoelectric effect from solid-state surfaces

Photoemission from a solid surface provides a wealth of information about its electronic structure and dynamic evolution. Ultrafast pump-probe experiments offer real-time access to photon-surface interactions and the resulting electron dynamics. Here, we present a femtosecond time-resolved photoelectron spectroscopy study of laser-assisted photoemission (LAPE) from two different metal surfaces, tungsten and platinum. Utilizing synchronized IR laser and x-ray pulses, photoelectron sideband generation up to the sixth order is observed. A significant material-dependent variation of the LAPE response has not been predicted by previous theoretical models, to the best of our knowledge. The observed phenomena are semiquantitatively reproduced by considering distinct dynamic dielectric responses of the two materials. In conclusion, these findings provide a deeper understanding of the LAPE process and insights into the dynamic interplay between optical laser fields and metal surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The construction of a highly transportable laser ranging station

The technology of the transportable Laser Ranging Station (TLRS) used in crustal dynamics studies was examined. The TLRS used a single photoelectron beam of limited energy density returned from the Laser Geodynamic Satellite (LAGEOS). Calibration was accomplished by the diversion of a small portion of the outgoing beam attenuated to the same level as the satellite return. Timing for the system was based on a self calibrating Ortec TD811, 100 picosec time interval device. The system was contained in a modified, single chassis recreational vehicle that allowed rapid deployment. The TLRS system was only airmobile on the largest transport aircraft. A 30 cm simple plano/concave transfer lens telescope aided in beam direction. The TLRS system fulfills the need for an accurate method of obtaining range measurements to the LAGEOS satellite incorporated in a mobile, air transportable, and economical configuration.

Source record↗

Shock initiation of nano-Al/Teflon: High dynamic range pyrometry measurements

In this paper, laser-launched flyer plates (25 μm thick Cu) were used to impact-initiate reactive materials consisting of 40 nm Al particles embedded in Teflon AF polymer (Al/Teflon) on sapphire substrates at a stoichiometric concentration (2.3:1 Teflon:Al), as well as one-half and one-fourth that concentration. A high dynamic range emission spectrometer was used to time and spectrally resolve the emitted light and to determine graybody temperature histories with nanosecond time resolution. At 0.5 km s -1 , first light emission was observed from Teflon, but at 0.6 km s -1 , the emission from Al/Teflon became much more intense, so we assigned the impact threshold for Al/Teflon reactions to be 0.6 (±0.1) km s -1 . The flyer plates produced a 7 ns duration steady shock drive. Emission from shocked Al/Teflon above threshold consisted of two bursts. At the higher impact velocities, the first burst started 15 ns after impact, peaked at 25 ns, and persisted for 75 ns. The second burst started at a few hundred nanoseconds and lasted until 2 μs. The 15 ns start time was exactly the time the flyer plate velocity dropped to zero after impact with sapphire. The first burst was associated with shock-triggered reactions and the second, occurring at ambient pressure, was associated with combustion of leftover material that did not react during shock. The emission spectrum was found to be a good fit to a graybody at all times, allowing temperature histories to be extracted. At 25 ns, the temperature at 0.7 km s -1 and the one-fourth Al load was 3800 K. Those temperatures increased significantly with impact velocity, up to 4600 K, but did not increase as much with Al load. A steady combustion process at 2800 (±100) K was observed in the microsecond range. Finally, the minimal dependence on Al loading indicates that these peak temperatures arise primarily from Al nanoparticles reacting almost independently, since the presence of nearby heat sources had little influence on the peak temperatures.

36 MATERIALS SCIENCE↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment of asymmetric-top molecules using multiple-pulse trains

We theoretically analyze the effectiveness of multiple-pulse laser alignment methods for asymmetric-top molecules. As an example, we choose SO{sub 2} and investigate the alignment dynamics induced by two different sequences, each consisting of four identical laser pulses. Each sequence differs only in the time delay between the pulses. Equally spaced pulses matching the alignment revival of the symmetrized SO{sub 2} rotor model are exploited in the first sequence. The pulse separations in the second sequence are short compared to the rotation dynamics of the molecule and monotonically increase the degree of alignment until the maximum alignment is reached. We point out the significant differences between the alignment dynamics of SO{sub 2} treated as an asymmetric-top and a symmetric-top rotor, respectively. We also explain why the fast sequence of laser pulses creates considerably stronger one-dimensional molecular alignment for asymmetric-top molecules. In addition, we show that multiple-pulse trains with elliptically polarized pulses do not enhance one-dimensional alignment or create three-dimensional alignment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear fusion of deuterons with light nuclei driven by Coulomb explosion of nanodroplets

Theoretical-computational studies of table-top laser-driven nuclear fusion of high energy (up to 15 MeV) deuterons with {sup 7}Li, {sup 6}Li, T, and D demonstrate the attainment of high fusion yields. The reaction design constitutes a source of Coulomb exploding deuterium nanodroplets driven by an ultraintense, near-infrared, femtosecond Gaussian laser pulse (peak intensity 2 Multiplication-Sign 10{sup 18}-5 Multiplication-Sign 10{sup 19} W cm{sup -2}) and a solid, hollow cylindrical target containing the second reagent. The exploding nanodroplets source is characterized by the deuteron kinetic energies, their number, and the laser energy absorbed by a nanodroplet. These were computed by scaled electron and ion dynamics simulations, which account for intra-nanodroplet laser intensity attenuation and relativistic effects. The fusion yields Y are determined by the number of the source deuterons and by the reaction probability. When laser intensity attenuation is weak within a single nanodroplet and throughout the nanodroplets assembly, Y exhibits a power law increase with increasing the nanodroplet size. Y is maximized for the nanodroplet size and laser intensity corresponding to the 'transition' between the weak and the strong intensity attenuation domains. The dependence of Y on the laser pulse energy W scales as W{sup 2} for weak assembly intensity attenuation, and as W for strong assembly intensity attenuation. This reaction design attains the highest table-top fusion efficiencies (up to 4 Multiplication-Sign 10{sup 9} J{sup -1} per laser pulse) obtained up to date.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The locking and unlocking thresholds for tearing modes in a cylindrical tokamak

The locking and unlocking thresholds for tearing modes are in general different. In this work, the physics origin for this difference is illustrated from theory analysis, and a numerical procedure is developed to find both locking and unlocking thresholds. In particular, a new scaling law for the unlocking threshold that is valid in both weak and strong rotation regimes has been derived from the lowest amplitude of the RMP (resonant magnetic perturbation) allowed for the locked-mode solution. Above the unlocking threshold, the criterion for the phase-flip instability is extended to identify the entire locked-mode states. Two different regimes of the RMP amplitude in terms of the accessibility of the locked-mode states have been found. In the first regime, the locked-mode state may or may not be accessible depending on the initial conditions of an evolving island. In the second regime, the locked-mode state can always be reached regardless of the initial conditions of the tearing mode. The lowest RMP amplitude for the second regime is determined to be the mode-locking threshold. The different characteristics of the two regimes above the unlocking threshold reveal the underlying physics for the gap between the locking and unlocking thresholds and provide an explanation for the closely related and widely observed hysteresis phenomena in island evolution during the sweeping process of the RMP amplitude up and down across that threshold gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking semiclassical approaches to strong-field QED: Nonlinear Compton scattering in intense laser pulses

The recoil associated with photon emission is key to the dynamics of ultrarelativistic electrons in strong electromagnetic fields, as found in high-intensity laser-matter interactions and astrophysical environments such as neutron star magnetospheres. When the energy of the photon becomes comparable to that of the electron, it is necessary to use quantum electrodynamics (QED) to describe the dynamics accurately. However, computing the appropriate scattering matrix element from strong-field QED is not generally possible due to multiparticle effects and the complex structure of the electromagnetic fields. Therefore, these interactions are treated semiclassically, coupling probabilistic emission events to classical electrodynamics using rates calculated in the locally constant field approximation. Here, we provide comprehensive benchmarking of this approach against the exact QED calculation for nonlinear Compton scattering of electrons in an intense laser pulse. We find agreement at the percentage level between the photon spectra, as well as between the models' predictions of absorption from the background field, for normalized amplitudes a0 > 5. We discuss possible routes towards improved numerical methods and the implications of our results for the study of QED cascades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative melting and healing of B-DNA and Z-DNA by an infrared laser pulse

We explore the use of a fast laser melting simulation approach combined with atomistic molecular dynamics simulations in order to determine the melting and healing responses of B-DNA and Z-DNA dodecamers with the same d(5′-CGCGCGCGCGCG-3′){sub 2} sequence. The frequency of the laser pulse is specifically tuned to disrupt Watson-Crick hydrogen bonds, thus inducing melting of the DNA duplexes. Subsequently, the structures relax and partially refold, depending on the field strength. In addition to the inherent interest of the nonequilibrium melting process, we propose that fast melting by an infrared laser pulse could be used as a technique for a fast comparison of relative stabilities of same-sequence oligonucleotides with different secondary structures with full atomistic detail of the structures and solvent. This could be particularly useful for nonstandard secondary structures involving non-canonical base pairs, mismatches, etc.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design considerations for gallium arsenide pulse compression photoconductive switch

In this paper, we present the physics and design-space exploration of a novel pulse compression photoconductive switch (PCPS) using semi-insulating gallium arsenide (GaAs) operating in the negative differential mobility (NDM) regime of electron transport. We systematically quantify the relationship between the PCPS performance and various design options, including contact separation, laser energy and placement, and trap dynamics. Specifically, we report the full-width at half-maximum and the peak output current generated by the PCPS as a function of applied electrical and optical bias. We discuss the optimal spacing between the electrodes and the distance of the laser spot to the anode to achieve higher electron confinement and superior radio-frequency (RF) metrics. Reducing the laser energy is important to prevent the appearance of secondary peaks due to diffusive transport, but there exists a trade-off between the bandwidth and the maximum current of the PCPS. We also compare the PCPS response with and without trap dynamics and find that the electrostatic screening from the trap-induced space charge is time-independent when the trapping time constant is set larger than the recombination lifetime. Overall, trap dynamics are detrimental to performance, unless the compensation doping scheme to achieve semi-insulating GaAs is carefully selected. Results presented in this paper can be used by experimentalists to fine-tune the PCPS design parameters to meet the specifications of various RF applications. Moreover, our results will provide a strong theoretical basis to the measurements of PCPS devices using GaAs and other NDM materials under investigation.

42 ENGINEERING↗

A global station coordinate solution based upon camera and laser data - GSFC 1973

The results of a determination of the coordinates of about 70 tracking stations are presented. The data were deived with the aid of dynamical techniques from precise reduced optical and laser observations of geodetic satellites. It is attempted to establish a reasonable accuracy estimate through a comparison of the data with other independent solutions. A brief description is given of the independent solutions used as a source of comparison.

Marsh, J. G.↗