Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

High Resolution Photoelectron Spectroscopy of the Acetyl Anion

High-resolution photoelectron spectra of cryogenically cooled acetyl anions (CH 3 CO - ) obtained using slow photoelectron velocity-map imaging are reported. The high resolution of the photoelectron spectrum yields a refined electron affinity of 0.4352 ± 0.0012 eV for the acetyl radical as well as the observation of a new vibronic structure that is assigned based on ab initio calculations. Three vibrational frequencies of the neutral radical are measured to be 1047 ± 3 cm -1 (ν 6 ), 834 ± 2 cm -1 (ν 7 ), and 471 ± 1 cm -1 (ν 8 ). Here this work represents the first experimental measurement of the ν 6 frequency of the neutral. The measured electron affinity is used to calculate a refined value of 1641.35 ± 0.42 kJ mol -1 for the gas-phase acidity of acetaldehyde. Analysis of the photoelectron angular distributions provides insight into the character of the highest occupied molecular orbital of the anion, revealing a molecular orbital with strong d-character. Additionally, details of a new centroiding algorithm based on finite differences, which has the potential to decrease data acquisition times by an order of magnitude at no cost to accuracy, are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional echocardiographic planimetry of maximal regurgitant orifice area in myxomatous mitral regurgitation: intraoperative comparison with proximal flow convergence

OBJECTIVES: We sought to validate direct planimetry of mitral regurgitant orifice area from three-dimensional echocardiographic reconstructions. BACKGROUND: Regurgitant orifice area (ROA) is an important measure of the severity of mitral regurgitation (MR) that up to now has been calculated from hemodynamic data rather than measured directly. We hypothesized that improved spatial resolution of the mitral valve (MV) with three-dimensional (3D) echo might allow accurate planimetry of ROA. METHODS: We reconstructed the MV using 3D echo with 3 degrees rotational acquisitions (TomTec) using a transesophageal (TEE) multiplane probe in 15 patients undergoing MV repair (age 59 +/- 11 years). One observer reconstructed the prolapsing mitral leaflet in a left atrial plane parallel to the ROA and planimetered the two-dimensional (2D) projection of the maximal ROA. A second observer, blinded to the results of the first, calculated maximal ROA using the proximal convergence method defined as maximal flow rate (2pi(r2)va, where r is the radius of a color alias contour with velocity va) divided by regurgitant peak velocity (obtained by continuous wave [CW] Doppler) and corrected as necessary for proximal flow constraint. RESULTS: Maximal ROA was 0.79 +/- 0.39 (mean +/- SD) cm2 by 3D and 0.86 +/- 0.42 cm2 by proximal convergence (p = NS). Maximal ROA by 3D echo (y) was highly correlated with the corresponding flow measurement (x) (y = 0.87x + 0.03, r = 0.95, p < 0.001) with close agreement seen (AROA (y - x) = 0.07 +/- 0.12 cm2). CONCLUSIONS: 3D echo imaging of the MV allows direct visualization and planimetry of the ROA in patients with severe MR with good agreement to flow-based proximal convergence measurements.

NASA Discipline Cardiopulmonary↗

NASA Tech Briefs, March 2007

Topics include: Advanced Systems for Monitoring Underwater Sounds; Wireless Data-Acquisition System for Testing Rocket Engines; Processing Raw HST Data With Up-to-Date Calibration Data; Mobile Collection and Automated Interpretation of EEG Data; System for Secure Integration of Aviation Data; Servomotor and Controller Having Large Dynamic Range; Digital Multicasting of Multiple Audio Streams; Translator for Optimizing Fluid-Handling Components; AIRSAR Web-Based Data Processing; Pattern Matcher for Trees Constructed From Lists; Reducing a Knowledge-Base Search Space When Data Are Missing; Ground-Based Correction of Remote-Sensing Spectral Imagery; State-Chart Autocoder; Pointing History Engine for the Spitzer Space Telescope; Low-Friction, High-Stiffness Joint for Uniaxial Load Cell; Magnet-Based System for Docking of Miniature Spacecraft; Electromechanically Actuated Valve for Controlling Flow Rate; Plumbing Fixture for a Microfluidic Cartridge; Camera Mount for a Head-Up Display; Core-Cutoff Tool; Recirculation of Laser Power in an Atomic Fountain; Simplified Generation of High-Angular-Momentum Light Beams; Imaging Spectrometer on a Chip; Interferometric Quantum-Nondemolition Single-Photon Detectors; Ring-Down Spectroscopy for Characterizing a CW Raman Laser; Complex Type-II Interband Cascade MQW Photodetectors; Single-Point Access to Data Distributed on Many Processors; Estimating Dust and Water Ice Content of the Martian Atmosphere From THEMIS Data; Computing a Stability Spectrum by Use of the HHT; Theoretical Studies of Routes to Synthesis of Tetrahedral N4; Estimation Filter for Alignment of the Spitzer Space Telescope; Antenna for Measuring Electric Fields Within the Inner Heliosphere; Improved High-Voltage Gas Isolator for Ion Thruster; and Hybrid Mobile Communication Networks for Planetary Exploration.

Source record↗

Hydra Rendezvous and Docking Sensor

The U.S. technology to support a CEV AR&D activity is mature and was developed by NASA and supporting industry during an extensive research and development program conducted during the 1990's and early 2000 time frame at the Marshall Space Flight Center. Development and demonstration of a rendezvous/docking sensor was identified early in the AR&D Program as the critical enabling technology that allows automated proxin~ity operations and docking. A first generation rendezvous/docking sensor, the Video Guidance Sensor (VGS) was developed and successfully flown on STS 87 and again on STS 95, proving the concept of a video-based sensor. Advances in both video and signal processing technologies and the lessons learned from the two successful flight experiments provided a baseline for the development of a new generation of video based rendezvous/docking sensor. The Advanced Video Guidance Sensor (AVGS) has greatly increased performance and additional capability for longer-range operation. A Demonstration Automatic Rendezvous Technology (DART) flight experiment was flown in April 2005 using AVGS as the primary proximity operations sensor. Because of the absence of a docking mechanism on the target satellite, this mission did not demonstrate the ability of the sensor to co~ltrold ocking. Mission results indicate that the rendezvous sensor operated successfully in "spot mode" (2 km acquisition of the target, bearing data only) but was never commanded to "acquire and track" the docking target. Parts obsolescence issues prevent the construction of current design AVGS units to support the NASA Exploration initiative. This flight proven AR&D technology is being modularized and upgraded with additional capabilities through the Hydra project at the Marshall Space Flight Center. Hydra brings a unique engineering approach and sensor architecture to the table, to solve the continuing issues of parts obsolescence and multiple sensor integration. This paper presents an approach to sensor hardware trades, to address the needs of future vehicles that may rendezvous and dock with the International Space Station (ISS). It will also discuss approaches for upgrading AVGS to address parts obsolescence, and concepts for modularizing the sensor to provide configuration flexibility for multiple vehicle applications. Options for complementary sensors to be integrated into the multi-head Hydra system will also be presented. Complementary sensor options include ULTOR, a digital image correlator system that could provide relative six-degree-of-freedom information independently from AVGS, and time-of-flight sensors, which determine the range between vehicles by timing pulses that travel from the sensor to the target and back. Common targets and integrated targets, suitable for use with the multi-sensor options in Hydra, will also be addressed.

Roe, Fred↗

Concurrent-scene/alternate-pattern analysis for robust video-based docking systems

A typical docking target employs a three-point design of retroreflective tape, one at each endpoint of the center-line, and one on the tip of the central post. Scenes, sensed via laser diode illumination, produce pictures with spots corresponding to desired reflection from the retroreflectors and other reflections. Control corrections for each axis of the vehicle can then be properly applied if the desired spots are accurately tracked. However, initial acquisition of these three spots (detection and identification problem) are non-trivial under a severe noise environment. Signal-to-noise enhancement, accomplished by subtracting the non-illuminated scene from the target scene illuminated by laser diodes, can not eliminate every false spot. Hence, minimization of docking failures due to target mistracking would suggest needed inclusion of added processing features pertaining to target locations. In this paper, we present a concurrent processing scheme for a modified docking target scene which could lead to a perfect docking system. Since the non-illuminated target scene is already available, adding another feature to the three-point design by marking two non-reflective lines, one between the two end-points and one from the tip of the central post to the center-line, would allow this line feature to be picked-up only when capturing the background scene (sensor data without laser illumination). Therefore, instead of performing the image subtraction to generate a picture with a high signal-to-noise ratio, a processed line-image based on the robust line detection technique (Hough transform) can be used to fuse with the actively sensed three-point target image to deduce the true locations of the docking target. This dual-channel confirmation scheme is necessary if a fail-safe system is to be realized from both the sensing and processing point-of-views. Detailed algorithms and preliminary results are presented.

Udomkesmalee, Suraphol↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

On-Orbit Performance & Operation of the Attitude & Pointing Control Subsystems on ASTERIA

The Arcsecond Space Telescope Enabling Research in Astrophysics (ASTERIA) is a 6U CubeSat that was deployed from the International Space Station on 20 November 2017. The underlying goal of the mission is to image and perform photometry on bright, nearby stars and possibly detect transiting exoplanets orbiting these stars. As a technology demonstration with an eye to enable this science, the payload must be pointed with a stability of 5 arcseconds RMS over 20-minute observations and a repeatability of 1 arcsecond RMS across multiple observations. A two-stage control system was employed to achieve these pointing requirements: reaction wheels control the attitude of the spacecraft bus while a piezo stage translates the focal plane array to control the pointing of the payload. This paper will present on-orbit results that demonstrate a pointing stability of 0.5 arcsecond RMS over 20 minutes and a pointing repeatability of 1 milliarcsecond RMS from observation to observation, the best pointing of a CubeSat to date. In addition, this paper will discuss the pointing achieved by the attitude control subsystem alone, pointing issues due to temporarily bright pixels, hot pixels, and reaction wheel speed reversals or zero crossings, the deployment and Sun acquisition phase, momentum management issues arising from a large residual dipole, and some of the anomalies encountered with the attitude control subsystem.

Pong, Christopher M.↗

Design of a Low-Cost, Submersible, Digital Holographic Microscope for in Situ Microbial Imaging

The methodologies for studying marine microbiology typically consist of utilizing instrumentation within a laboratory. This typically requires extracting a sample from its place of origin prior to examination, which may be days after collection. Oftentimes, the solution is to bring the lab to the ocean, which may be costly and provide further limitations for a sterile and stable laboratory environment. Here we present a low-cost, submersible, digital holographic microscope (DHM) designed to image marine microorganisms (such as bacteria and plankton) in their natural underwater environment. Our instrument eliminates the need to transport samples and allows for instantaneous data collection of microbes in-situ. The DHM achieves sub-micron spatial resolution and is paired with artificial intelligence for the detection and tracking of specimens to reduce the overall collected data. This instrument also aims to reduce the cost of manufacturing and field expenses relative to marine microbiological research. “Off the shelf” components were selected in the design process of this instrument which allows us to achieve precise results without sacrificing data quality. The DHM itself costs under one thousand dollars and features a low-cost high-resolution camera, the Arducam MT9J001. Included in the design were five main subsystems: optical, mechanical, electrical, power, and machine learning. Our on board computer and artificial intelligence consist of a Raspberry Pi 4 (8 Gb) and Google Coral USB Tensorflow accelerator. Instrument testing has successfully proven our abilities of data acquisition for at least two hours in depths of at least forty meters below sea level. Additionally, our artificial intelligence system is currently capable of tracking up to ten areas of interest in a fraction of a second with over ninety percent confidence via the neural net driven by the tensor cores on the Google Coral. Furthermore, we have demonstrated the versatility of our instrument by mounting it on an ocean-going ROV, the BlueRov2 by BlueRobotics. Our tests on the BlueRov2 exemplified the cost-effective nature of a submersible and reusable instrument that can be implemented in moderate environments and on most vessels.

Wallace, James Kent↗

Remote Sensing of Seasonal Leaf Area Index Across the Oregon Transect

Remotely sensed data acquired from four remote-sensing instruments on three different aircraft platforms over a transect of coniferous forest stands in Oregon were analyzed with respect to seasonal leaf area index (LAI). Data from the four instruments were corrected for the varying seasonal and geographic atmospheric conditions present along the transect. Strong logarithmic relationships were observed between seasonal maximum and minimum LAI and the simple ratio (SR) (near infrared/red reflectance) calculated from the broad-spectral-band Thematic Mapper Simulator (TMS), as well as from the narrow-spectral-band Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), the Compact Airborne Spectrographic Imager (CASI), and a Spectron SE590 spectro-radiometer (R(exp 2) = 0.82-0.97). The TMS SR reached an asymptote at an LAI of approx. 7-8. However, the SE590 and the CASI SR continued to increase up to the maximum LAI of 10.6. The variability of the relationship between the AVIRIS SR and LAI increased at stands with LAIs greater than 7, making a trend in the AVIRIS SR-LAI relationship at LAIs greater than 7 difficult to discern. The SRs of the coniferous forest stands measured by the narrow-spectral-band instruments were higher than they were from the broad-spectral-band TMS. This is attributed partially to the integration of the TMS over a broad wavelength region in the red and more strongly to calibration differences between the sensors. Seasonal TMS SR trends for four time periods for some of the stands deviated from the expected seasonal LAI trends, possibly because of smoke and very low sun angles during some of the acquisition periods. However, the expected SR differences for the seasonal minimum and maximum LAI were observed for all of the sensors for nearly all of the forest stands. This study, demonstrates that remotely, sensed data from both broad- and narrow spectral band instruments can provide estimates of LAI for use in forest ecosystems simulation models to estimate evapotranspiration, photosynthesis, canopy turnover, and net primary production over large areas.

Spanner, Michael↗

Subtask 1.5 – CO2 Injection Monitoring with an Optimized Scalable, Automated, Semipermanent Seismic Array

The scalable, automated, semipermanent seismic array (SASSA) method is a flexible and relatively cost-effective surface geophysical method for regular time-lapse monitoring of the movement of injected carbon dioxide (CO2) in a reservoir for CO2 enhanced oil recovery (EOR) or geologic CO2 storage operations. It has the advantages of a low-environmental-footprint while monitoring regions of a reservoir from the surface without the need for a regular grid distribution of receivers. Automated data collection is possible. As only time-lapse amplitude changes at the reservoir level due to CO2 movement within the reservoir are monitored, the turnaround time to deliver results from the SASSA method can be short, without the need for long, time-consuming data-processing workflows. As data is collected and processed, incremental information can be provided to the field operator. The Energy & Environmental Research Center (EERC) conducted a SASSA field test from September 2018 to November 2020 in a portion of the Bell Creek Field in Montana, which implemented new CO2 EOR field activities during the study period. Lessons learned from a proof-of-concept study were incorporated to improve the data quality of the SASSA method and demonstrate the viability of the technology. The EERC implemented several enhancements to improve data quality, including 1) an iterative survey design, which allowed placing the receivers in strategic locations where the movement of the CO2 in the reservoir could be tracked with minimum interference by the cultural noise in the study area; 2) the use of powerful seismic sources in the form of surface orbital vibrators, and 3) data acquisition during optimal periods. History-matched reservoir simulation was performed to predict gas saturation and pressure response induced by CO2 injection in the study area. The results were compared with the SASSA-measured responses to CO2 injection as a partial validation technique. A match between the two methods was observed for most of the SASSA points predicted to have intersected a CO2 saturation change. The validated results provide confidence that the SASSA method can be used independently as a CO2 saturation monitoring technique. As data are collected and processed, incremental information can be provided to the field operator. The critical components of the SASSA workflow for a successful application of the method are the following: Iterative survey design with information about CO2 injection activities from the oilfield operator. A detailed CO2 injection plan is the key driver to select the strategic monitoring location of the SASSA sensors. After this information is incorporated in the initial distribution of sources and receivers in the study area, high-resolution satellite images are used to identify ground locations not affected by cultural noise sources, such as power lines, pipelines/flow lines, or roadways. In the next iteration of the survey design, a scouting trip to the study area is needed to understand more details of the noise sources identified in the previous step and the intensity of the field activities that can also generate noise during the monitoring. Integrating the information from the scouting trip into the survey design to select the optimum source and receiver locations is the final step. Noise attenuation. The variety of noise types during seismic monitoring of an oil field is enormous. Tailored noise characterization and processing at a node-by-node level can enhance the performance and sensitivity of the SASSA technique. Future advancements that could improve the efficiency and application of the SASSA technology include: Gaining a better understanding of the noise field produced by the seismic source to aid the choice of receiver location. Surface noise from the source can overwhelm the small signal changes due to CO2 that the SASSA method measures. Improved data-processing workflow to automatically analyze and adapt to dynamic noise conditions associated with industrial settings. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE- FE0024233.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tailoring spectral properties for entangled photon generation

The linear intensity scaling of entangled two-photon absorption (ETPA) offers a fundamental mechanism to enable nonlinear optical spectroscopy and microscopy under a substantially lower excitation power than is currently feasible. However, the long data acquisition time and low signal-to-noise ratio in reported ETPA-based spectroscopic and microscopic studies prevent its widespread application. To gain the full potential of this novel quantum light approach, it is essential to optimize entangled photon generation for significantly enhanced ETPA responses. Here, we report a new quantum light source by combining entangled photon generation with free-space femtosecond pump-pulse shaping. Here, through measurements of singles and coincidence counts by varying the patterns applied to a spatial light modulator to control the spectral widths of the pump pulses, we reveal strong dependence of the singles and coincidence count rates as well as their ratios on the spectral widths of pump pulses. An optimal spectral width for the highest ratios between the coincidence photon and the signal or idler photon count rates is also determined. Identification of such optimal spectral widths for entangled photon generation in the presence of postgeneration spectral selection makes this quantum light source a promising choice for ETPA-based spectroscopy and imaging.

Photon pairs & parametric down-conversion↗

Finding Fast Transients in Real Time Using a Novel Light-curve Analysis Algorithm

The current data acquisition rate of astronomical transient surveys and the promise for significantly higher rates in the next decade necessitate the development of novel approaches to analyze astronomical data sets and promptly detect objects of interest. The Deeper, Wider, Faster (DWF) program is a survey focused on the identification of fast-evolving transients, such as fast radio bursts, gamma-ray bursts, and supernova shock breakouts. It employs multifrequency simultaneous coverage of the same part of the sky over several orders of magnitude. Using the Dark Energy Camera mounted on the 4 m Blanco telescope, DWF captures a 20 s g -band exposure every minute, at a typical seeing of ~1'' and an air mass of ~1.5. These optical data are collected simultaneously with observations conducted over the entire electromagnetic spectrum—from radio to γ -rays—as well as cosmic-ray observations. In this paper, we present a novel real-time light-curve analysis algorithm, designed to detect transients in the DWF optical data; this algorithm functions independently from, or in conjunction with, image subtraction. We present a sample of fast transients detected by our algorithm, as well as a false-positive analysis. Our algorithm is customizable and can be tuned to be sensitive to transients evolving over different timescales and flux ranges.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an Open-source Alloy Selection and Lifetime Assessment Tool for Structural Components in CSP

Lack of sufficient data on high temperature mechanical and corrosion behavior of structural materials is a huge barrier in the technological maturity of current and future Concentrating Solar Power (CSP) technologies. Rapid development and selection of materials cannot be achieved by expensive and time-consuming acquisition of experimental data. The goal of the proposed work is development of an open-source alloy selection and lifetime prediction tool that will integrate validated physics-based models to describe influence of temperature, alloy composition, environment and component geometry (thickness) on mechanical and corrosion behavior of Ni and Fe-based alloys employed in molten salts/sCO 2 heat exchangers. This one-year project leveraged the extensive dataset on the creep\corrosion behavior of candidate materials generated at ORNL through past projects and input from current collaborations with industrial partners. Based on previous experience and the feedback provided by industry (Brayton Energy and Echogen), three candidate materials of interest, Ni-based alloys 740H, 282 and 625 and application-specific operating conditions (max. temperature of 730 °C and stress of 150 MPa) were identified for the heat exchanger. An extensive corrosion and creep dataset was assimilated for the relevant operating conditions and was supported by detailed characterization of about 100 metallographic cross-sections. The corrosion dataset consisted of scanning electron microscopy images (secondary electron and backscatter electron), measured concentration profiles of alloying elements using energy dispersive X-ray spectroscopy (EDS), widths of denuded zones (dissolution of strengthening phases) and depths of attack in molten KCl-MgCl 2 mixtures using image analyses. The creep dataset comprised of creep rupture data and creep strain curves (for 740H and 282). Coupled thermodynamic-kinetic microstructure-based models were employed to predict the stress-corrosion induced compositional and phase evolutions in the alloy during operation under the identified operating conditions. Reduced order models were developed from advanced physics-based models and were integrated in a user-friendly alloy selection tool. The corrosion model was able to predict the time to a critical Cr concentration at the oxide/alloy interface (chemical lifetime) within ±10% (1 standard deviation) of typical statistical variation in corrosion tests and EDS measurement errors (±0.5 wt%). The initial scope of the project was limited to predict creep rupture times (Larson-Miller parameter). Based on the input provided by industry, the mechanical lifetime of the heat exchanger is governed by accumulated creep strains (2%) rather than creep rupture. To be able to predict the times to specific creep strains, a more extensive creep model development was undertaken largely beyond the initial scope of the project. The continuum damage mechanics creep model was able to predict times to 2% creep strain, t 2% with an accuracy of ±500h. Ultimately, a screening protocol for SiC was generated to demonstrate the pathway for integration of one of the currently immature materials from a commercial adoption standpoint in the current material evaluation tool. The modeling tool developed here is accessible to the science community and stakeholders and lays the foundation for methods that will enable a rapid evaluation of optimum materials for CSP applications and reliable prediction of material degradation thereby considerably reducing operational costs, improving reliability and increasing overhaul intervals. However, the complete potential of such a tool to include a wider range of materials and test conditions can only be realized with a more concentrated combined experimental-characterization-computation effort.

14 SOLAR ENERGY↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Fiber-Optic Imaging Probe Developed for Space Used to Detect Diabetes Through the Eye

Approximately 16 million Americans have diabetes mellitus, which can severely impair eyesight by causing cataracts, diabetic retinopathy, and glaucoma. Cataracts are 1.6 times more common in people with diabetes than in those without diabetes, and cataract extraction is the only surgical treatment. In many cases, diabetes-related ocular pathologies go undiagnosed until visual function is compromised. This ongoing pilot project seeks to study the progression of diabetes in a unique animal model by monitoring changes in the lens with a safe, sensitive, dynamic light-scattering probe. Dynamic light scattering (DLS), has the potential to diagnose cataracts at the molecular level. Recently, a new DLS fiber-optic probe was developed at the NASA Glenn Research Center at Lewis Field for noncontact, accurate, and extremely sensitive particle-sizing measurements in fluid dispersions and suspensions (ref. 1). This compact, portable, and rugged probe is free of optical alignment, offers point-and-shoot operation for various online field applications and challenging environments, and yet is extremely flexible in regards to sample container sizes, materials, and shapes. No external vibration isolation and no index matching are required. It can measure particles as small as 1 nm and as large as few micrometers in a wide concentration range from very dilute (waterlike) dispersions to very turbid (milklike) suspensions. It is safe and fast to use, since it only requires very low laser power (10 nW to 3 mW) with very short data acquisition times (2 to 10 sec).

Ansari, Rafat R.↗

The solenoidal large intensity device (SoLID) for JLab 12 GeV

The solenoidal large intensity device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3D momentum space from semi-inclusive deep inelastic scattering, expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS, a precision measurement of J/ψ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.

3D imaging↗

Mutual-information based optimal experimental design for hyperpolarized $$^{13}$$C-pyruvate MRI

Abstract A key parameter of interest recovered from hyperpolarized (HP) MRI measurements is the apparent pyruvate-to-lactate exchange rate, $$k_{{\textrm PL}}$$ k P L , for measuring tumor metabolism. This manuscript presents an information-theory-based optimal experimental design approach that minimizes the uncertainty in the rate parameter, $$k_{{\textrm PL}}$$ k P L , recovered from HP-MRI measurements. Mutual information is employed to measure the information content of the HP measurements with respect to the first-order exchange kinetics of the pyruvate conversion to lactate. Flip angles of the pulse sequence acquisition are optimized with respect to the mutual information. A time-varying flip angle scheme leads to a higher parameter optimization that can further improve the quantitative value of mutual information over a constant flip angle scheme. However, the constant flip angle scheme, 35 and 28 degrees for pyruvate and lactate measurements, leads to an accuracy and precision comparable to the variable flip angle schemes obtained from our method. Combining the comparable performance and practical implementation, optimized pyruvate and lactate flip angles of 35 and 28 degrees, respectively, are recommended.

97 MATHEMATICS AND COMPUTING↗

A Topographical Lidar System for Terrain-Relative Navigation

An imaging lidar system is being developed for use in navigation, relative to the local terrain. This technology will potentially be used for future spacecraft landing on the Moon. Systems like this one could also be used on Earth for diverse purposes, including mapping terrain, navigating aircraft with respect to terrain and military applications. The system has been field-tested aboard a helicopter in the Mojave Desert. When this system was designed, digitizers with sufficient sampling rate (2 GHz) were only available with very limited memory. Also, it was desirable to limit the amount of data to be transferred between the digitizer and the mass storage between individual frames. One of the novelty design features of this system was to design the system around the limited amount of memory of the digitizer. The system is required to operate over an altitude (distance) range from a few meters to approximately 1 km, but for each scan across the full field of view, the digitizer memory is only able to hold data for an altitude range no more than 100 m. Data acquisition methods in support of the limited 100 m wide altitude range are described.

Liebe, Carl Christian↗