Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Image processing with cellular nonlinear networks implemented on field-programmable gate arrays for real-time applications in nuclear fusion

In the past years cameras have become increasingly common tools in scientific applications. They are now quite systematically used in magnetic confinement fusion, to the point that infrared imaging is starting to be used systematically for real-time machine protection in major devices. However, in order to guarantee that the control system can always react rapidly in case of critical situations, the time required for the processing of the images must be as predictable as possible. The approach described in this paper combines the new computational paradigm of cellular nonlinear networks (CNNs) with field-programmable gate arrays and has been tested in an application for the detection of hot spots on the plasma facing components in JET. The developed system is able to perform real-time hot spot recognition, by processing the image stream captured by JET wide angle infrared camera, with the guarantee that computational time is constant and deterministic. The statistical results obtained from a quite extensive set of examples show that this solution approximates very well an ad hoc serial software algorithm, with no false or missed alarms and an almost perfect overlapping of alarm intervals. The computational time can be reduced to a millisecond time scale for 8 bit 496x560-sized images. Moreover, in our implementation, the computational time, besides being deterministic, is practically independent of the number of iterations performed by the CNN - unlike software CNN implementations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hardened gated x-ray imaging diagnostic for inertial confinement fusion experiments at the National Ignition Facility

A gated x-ray detector is under development for use at the National Ignition Facility that is intended to provide plasma emission images in the presence of neutron yields up to 10{sup 15} expected during inertial confinement fusion experiments with layered cryogenic targets. These images are expected to provide valuable time-resolved measurements of core and fuel symmetries. Additional capabilities of this instrument will include the ability to make spatially resolved electron temperature measurements. A description of this instrument and its operation is given with emphasis on features that differentiate it from previous designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring symmetry of implosions in cryogenic Hohlraums at the NIF using gated x-ray detectors (invited)

Ignition of imploding inertial confinement capsules requires, among other things, controlling the symmetry with high accuracy and fidelity. We have used gated x-ray imaging, with 10 {mu}m and 70 ps resolution, to detect the x-ray emission from the imploded core of symmetry capsules at the National Ignition Facility. The measurements are used to characterize the time dependent symmetry and the x-ray bang time of the implosion from two orthogonal directions. These measurements were one of the primary diagnostics used to tune the parameters of the laser and Hohlraum to vary the symmetry and x-ray bang time of the implosion of cryogenically cooled ignition scale deuterium/helium filled plastic capsules. Here, we will report on the successful measurements performed with up to 1.2 MJ of laser energy in a fully integrated cryogenics gas-filled ignition-scale Hohlraum and capsule illuminated with 192 smoothed laser beams. We will describe the technique, the accuracy of the technique, and the results of the variation in symmetry with tuning parameters, and explain how that set was used to predictably tune the implosion symmetry as the laser energy, the laser cone wavelength separation, and the Hohlraum size were increased to ignition scales. We will also describe how to apply that technique to cryogenically layered tritium-hydrogen-deuterium capsules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution core-level photoemission study of CF{sub 4}-treated Gd{sub 2}O{sub 3}(Ga{sub 2}O{sub 3}) gate dielectric on Ge probed by synchrotron radiation

High-resolution core-level photoemission analysis using synchrotron radiation was used to investigate the superior electrical performance of aGa{sub 2}O{sub 3}(Gd{sub 2}O{sub 3}) gate dielectric on Ge(001) after CF{sub 4} treatment. Prior to the treatment, a thin germanate-like oxide layer that formed at the interface prevented Ge from diffusing to the surface. The Ge surface retained a small amount of buckled dimers from the as-grown sample. The buckled dimers were quickly removed by CF{sub 4} plasma treatment followed by an annealing process, resulting in a more uniform interface than that of the as-grown sample. The detailed interfacial electronic structure for the untreated and treated samples are presented.

36 MATERIALS SCIENCE↗

GaSb molecular beam epitaxial growth on p-InP(001) and passivation with in situ deposited Al{sub 2}O{sub 3} gate oxide

The integration of high carrier mobility materials into future CMOS generations is presently being studied in order to increase drive current capability and to decrease power consumption in future generation CMOS devices. If III-V materials are the candidates of choice for n-type channel devices, antimonide-based semiconductors present high hole mobility and could be used for p-type channel devices. In this work we first demonstrate the heteroepitaxy of fully relaxed GaSb epilayers on InP(001) substrates. In a second part, the properties of the Al{sub 2}O{sub 3}/GaSb interface have been studied by in situ deposition of an Al{sub 2}O{sub 3} high-{kappa} gate dielectric. The interface is abrupt without any substantial interfacial layer, and is characterized by high conduction and valence band offsets. Finally, MOS capacitors show well-behaved C-V with relatively low D{sub it} along the bandgap, these results point out an efficient electrical passivation of the Al{sub 2}O{sub 3}/GaSb interface.

36 MATERIALS SCIENCE↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixing Of Mode Symmetries In Top Gated Bilayer And Multilayer Graphene Field Effect Devices

We report Raman study to investigate the influence of stacking on the inversion symmetry breaking in top gated bi- and multi-layer ({approx}10 layers) graphene field effect transistors. The G phonon mode splits into a low frequency (G{sub low}) and a high frequency (G{sub high}) mode in bi- and multi-layer graphene and the two modes show different dependence on doping. The mode splitting is explained in terms of mixing of zone-center in-plane optical phonons representing in-phase and out-of-phase inter-layer atomic motions. Unlike in bilayer graphene, there is no transfer of intensity from G{sub low} to G{sub high} in multilayer graphene. A comparison is made for the bilayer graphene data with the recent theory of Gava et al. [Phys. Rev. B 80, 155422 (2009)].

36 MATERIALS SCIENCE↗

Synergetic effects of double laser pulses for the formation of mild plasma in water: Toward non-gated underwater laser-induced breakdown spectroscopy

We experimentally study the dynamics of the plasma induced by the double-laser-pulse irradiation of solid target in water, and find that an appropriate choice of the pulse energies and pulse interval results in the production of an unprecedentedly mild (low-density) plasma, the emission spectra of which are very narrow even without the time-gated detection. The optimum pulse interval and pulse energies are 15-30 {mu}s and about {approx}1 mJ, respectively, where the latter values are much smaller than those typically employed for this kind of study. In order to clarify the mechanism for the formation of mild plasma we examine the role of the first and second laser pulses, and find that the first pulse produces the cavitation bubble without emission (and hence plasma), and the second pulse induces the mild plasma in the cavitation bubble. These findings may present a new phase of underwater laser-induced breakdown spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-high speed photomultiplier tubes with nanosecond gating for fusion diagnostics

Fusion diagnostics can involve the measurement of ultra-fast optical pulses, often in close temporal proximity. We present a solution for the diagnostics of gamma reaction history and neutron time of flight by using microchannel plate based photomultiplier tubes (PMTs). The time response of the PMTs can be as fast as 100 ps FWHM and with a gain of up to 10{sup 7}. To observe small events in close temporal proximity to much larger signals such as the down-scattered fraction, the response of MCP-PMTs can be gated with an on/off ratio of up to 10{sup 13} in just 2 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A field programmable gate array unit for the diagnosis and control of neoclassical tearing modes on MAST

A real-time system has been developed to trigger both the MAST Thomson scattering (TS) system and the plasma control system on the phase and amplitude of neoclassical tearing modes (NTMs), extending the capabilities of the original system. This triggering system determines the phase and amplitude of a given NTM using magnetic coils at different toroidal locations. Real-time processing of the raw magnetic data occurs on a low cost field programmable gate array (FPGA) based unit which permits triggering of the TS lasers on specific amplitudes and phases of NTM evolution. The MAST plasma control system can receive a separate trigger from the FPGA unit that initiates a vertical shift of the MAST magnetic axis. Such shifts have fully removed m/n= 2/1 NTMs instabilities on a number of MAST discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully integrated InGaAs/InP single-photon detector module with gigahertz sine wave gating

InGaAs/InP single-photon avalanche diodes (SPADs) working in the regime of GHz clock rates are crucial components for the high-speed quantum key distribution (QKD). We have developed for the first time a compact, stable, and user-friendly tabletop InGaAs/InP single-photon detector system operating at a 1.25 GHz gate rate that fully integrates functions for controlling and optimizing SPAD performance. We characterize the key parameters of the detector system and test the long-term stability of the system for continuous operation of 75 h. The detector system can substantially enhance QKD performance and our present work paves the way for practical high-speed QKD applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital optical phase-locked loop for diode lasers based on field programmable gate array

We have designed and implemented a highly digital optical phase-locked loop (OPLL) for diode lasers in atom interferometry. The three parts of controlling circuit in this OPLL, including phase and frequency detector (PFD), loop filter and proportional integral derivative (PID) controller, are implemented in a single field programmable gate array chip. A structure type compatible with the model MAX9382/MCH12140 is chosen for PFD and pipeline and parallelism technology have been adapted in PID controller. Especially, high speed clock and twisted ring counter have been integrated in the most crucial part, the loop filter. This OPLL has the narrow beat note line width below 1 Hz, residual mean-square phase error of 0.14 rad{sup 2} and transition time of 100 {mu}s under 10 MHz frequency step. A main innovation of this design is the completely digitalization of the whole controlling circuit in OPLL for diode lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma immersion ion implantation for sub-22 nm node devices: FD-SOI and Tri-Gate

Here, we present and discuss the electrical characteristics of fully depleted MOSFET transistors of planar and tridimensional architecture, doped by Plasma Immersion Ion Implantation (PIII) or Beam Line Ion Implantation (BLII). Both techniques delivered similar and satisfactory results in considering the planar architecture. For tri-dimensional Tri-Gate transistors, the results obtained with PIII are superior.

36 MATERIALS SCIENCE↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of ZrN capping layer deposited on ultra-thin high-k Zr-doped yttrium oxide for metal-gate metal–insulator–semiconductor applications

Metal-gate MIS structures with and without ZrN capping layer on high-k Y{sub 2}O{sub 3}:Zr/Y{sub 2}O{sub 3} stack were fabricated. The binding energies and depth profiles were investigated by x-ray photoelectron spectroscopy (XPS). The x-ray diffraction (XRD) patterns were compared. It is found that Ti out-diffusion into Zr-based high-k dielectric becomes lesser with the insertion of ZrN capping layer. The electrical properties of current-voltage (I-V) and capacitance-voltage (C-V) characteristics were measured in the postannealing temperature range of 550–850 °C. According to the defect reaction model, Zr cation vacancies are associated with the concentration of Ti ion by a transition from +3 to +2 states. The amount of Zr cation vacancies is quantified and equal to a half of Ti substitution amount at Zr site. The reduction in cation vacancies at high temperatures can well explain the decrease in ΔV{sub FB} for samples with ZrN layer. In contrast, an excess of Ti outdiffusion will produce the interstitial defects in high-k films without ZrN capping.

36 MATERIALS SCIENCE↗

Influence of plasma-based in-situ surface cleaning procedures on HfO{sub 2}/In{sub 0.53}Ga{sub 0.47}As gate stack properties

We report on the influence of variations in the process parameters of an in-situ surface cleaning procedure, consisting of alternating cycles of nitrogen plasma and trimethylaluminum dosing, on the interface trap density of highly scaled HfO{sub 2} gate dielectrics deposited on n-In{sub 0.53}Ga{sub 0.47}As by atomic layer deposition. We discuss the interface chemistry of stacks resulting from the pre-deposition exposure to nitrogen plasma/trimethylaluminum cycles. Measurements of interface trap densities, interface chemistry, and surface morphology show that variations in the cleaning process have a large effect on nucleation and surface coverage, which in turn are crucial for achieving low interface state densities.

36 MATERIALS SCIENCE↗

Recovery from ultraviolet-induced threshold voltage shift in indium gallium zinc oxide thin film transistors by positive gate bias

The effect of short-duration ultraviolet (UV) exposure on the threshold voltage (V{sub th}) of amorphous indium gallium zinc oxide thin film transistors (TFTs) and its recovery characteristics were investigated. The V{sub th} exhibited a significant negative shift after UV exposure. The V{sub th} instability caused by UV illumination is attributed to the positive charge trapping in the dielectric layer and/or at the channel/dielectric interface. The illuminated devices showed a slow recovery in threshold voltage without external bias. However, an instant recovery can be achieved by the application of positive gate pulses, which is due to the elimination of the positive trapped charges as a result of the presence of a large amount of field-induced electrons in the interface region.

36 MATERIALS SCIENCE↗