Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Analysis of shockless dynamic compression data on solids to multi-megabar pressures: Application to tantalum

Magnetically-driven, planar shockless-compression experiments to multi-megabar pressures were performed on tantalum samples using a stripline target geometry. Free-surface velocity waveforms were measured in 15 cases; nine of these in a dual-sample configuration with two samples of different thicknesses on opposing electrodes, and six in a single-sample configuration with a bare electrode opposite the sample. Details are given on the application of inverse Lagrangian analysis (ILA) to these data, including potential sources of error. The most significant source of systematic error, particularly for single-sample experiments, was found to arise from the pulse-shape dependent free-surface reflected wave interactions with the deviatoric-stress response of tantalum. This could cause local, possibly temporary, unloading of material from a ramp compressed state, and thus multi-value response in wave speed that invalidates the free-surface to in-material velocity mapping step of ILA. By averaging all 15 data sets, a final result for the principal quasi-isentrope of tantalum in stress-strain was obtained to a peak longitudinal stress of 330 GPa with conservative uncertainty bounds of ±4.5% in stress. The result agrees well with a tabular equation of state developed at Los Alamos National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionospheric calibration for single frequency altimeter measurements

This study is a preliminary analysis of the effectiveness (in terms of altimeter calibration accuracy) of various ionosphere models and the Global Positioning System (GPS) to calibrate single frequency altimeter height measurements for ionospheric path delay. In particular, the research focused on ingesting GPS Total Electron Content (TEC) data into the physical Parameterized Real-Time Ionospheric Specification Model (PRISM), which estimates the composition of the ionosphere using independent empirical and physical models and has the capability of adjusting to additional ionospheric measurements. Two types of GPS data were used to adjust the PRISM model: GPS receiver station data mapped from line-of-sight observations to the vertical at the point of interest and a grid map (generated at the Jet Propulsion Laboratory) of GPS derived TEC in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by the International Reference Ionosphere (IRI-90), a climatological (monthly mean) model of the ionosphere, were compared to TOPEX dual-frequency TEC measurements (considered as truth) for a number of TOPEX sub-satellite tracks. For a 13.6 GHz altimeter, a Total Electron Content (TEC) of 1 TECU 10(exp 16) electrons/sq m corresponds to approximately 0.218 centimeters of range delay. A maximum expected TEC (at solar maximum or during solar storms) of 10(exp 18) electrons/sq m will create 22 centimeters of range delay. Compared with the TOPEX data, the PRISM predictions were generally accurate within the TECU when the sub-satellite track of interest passed within 300 to 400 km of the GPS TEC data or when the track passed through a night-time ionosphere. If neither was the case, in particular if the track passed through a local noon ionosphere, the PRISM values differed by more than 10 TECU and by as much as 40 TECU. The IRI-90 model, with no current ability to unseat GPS data, predicted TEC to a slightly higher error of 12 TECU. The performance of PRISM is very promising for predicting TEC and will prove useful for calibrating single frequency altimeter height measurements for ionospheric path delay. When adjusted to the GPS line-of-sight data the PRISM URSI empirical model predicted TEC over a day's period to within a global error of 8.60 TECU rms during a nighttime ionosphere and 9.74 TECU rms during the day. When adjusted to the GPS derived TEC grid, the PRISM parametrized model predicted TEC to within an error of 8.47 TECU rms for a nighttime ionosphere and 12.83 TECU rms during the day. However, the grid cannot be considered globally due to the lack of sufficient numbers of GPS stations and large latitude gaps in GPS data. It is the opinion of the authors that using the PRISM model and adjusting to the global sun-fixed TEC grid regenerated with a localized weighted interpolation offers the best possibility of meeting the 10 TECU global rms (or 2 cm at 13.6 GHz) ionosphere range correction accuracy requirement of TOPEX/Poseidon and should be the subject of further study. However, it is clear that the anticipated requirement of 34 TECU global rms for TOPEX/Poseidon Follow-On (corresponding to the TOPEX/Poseidon performance) can not be met with any realizable combination of existing models and data assimilation schemes.

Schreiner, William S.↗

A sixth order Mehrstellen scheme with an application to the Method of Local Corrections for the 3D Poisson equation

We present a sixth order finite difference scheme for Poisson’s equation when discretized with the compact 27-point stencil based on Mehrstellen corrections of the forcing function term f. Our approach results in a sixth order accurate solution error as opposed to a fourth-order error imposed by the classical Mehrstellen correction for the 19-point and 27-point stencils. The present study is a continuation of former work of Spotz and Carey (1996) on compact finite difference schemes for Poisson’s equation where sixth order convergence may be obtained under the assumption that the fourth order derivatives of f are determined analytically. Specifically, we show that sixth order convergence can still be attained when only values of f at grid points are available. The sixth order Mehrstellen scheme is further coupled with a Method of Local Corrections (MLC) 3D Poisson solver improving to sixth order accuracy the results reported in Kavouklis and Colella (2019). The MLC test case considered involves an adaptive grid that comprises 7.5 billion cells.

97 MATHEMATICS AND COMPUTING↗

Examination of L-Band Brightness Temperature Forecasts in the SMAP Level-4 Soil Moisture Analysis

The NASA Soil Moisture Active Passive (SMAP) mission [4] has been providing L-band (1.4 GHz) passive microwave brightness temperature (Tb) observations since April 2015. By assimilating the Tb observations into the NASA Catchment land surface model [5] using a spatially distributed ensemble Kalman filter, the NASA Global Modeling and Assimilation Office generates the SMAP Level-4 Soil Moisture (L4_SM) product, which provides global, 3-hourly, 9-km resolution estimates of surface (0-5 cm) and root-zone (0-100 cm) soil moisture with ~2.5-day latency for use in research and applications [6]. The L4_SM product also includes estimates of soil temperature, land surface fluxes, and assimilation diagnostics such as the model forecast and observed Tb values [7]. The output from the L4_SM system is routinely monitored by the L4_SM team. Such monitoring provides valuable information; instances of unusually large Tb observation-minus-forecast (O-F) residuals can indicate events during which soil moisture conditions are poorly described in the land modeling system [7,8]. For example, repeated occurrences of very large Tb O-F values in central Australia were traced back to deficiencies in the gauge-based precipitation product used in the land modeling system through L4_SM Version 5; this discovery prompted the use, beginning in Version 6, of satellite- and gauge-based precipitation observations outside of North America [9]. Recently, a statistical analysis of the Tb O-F residuals revealed systematic errors in the “tau-omega” L-band radiative transfer model that converts the land-model simulated soil moisture and temperature into the forecast Tb prior to the L4_SM analysis. The L4_SM analysis is built on the ensemble Kalman filter and assumes unbiased forecast errors. The presence of systematic Tb forecast errors could thus adversely impact the quality of the analyzed soil moisture. In this paper, we examine the Tb O-F residuals of the latest Version 7 L4_SM data (Science Version ID Vv7030 and Vv7032) [10,11,12]. In the L4_SM Version 7 algorithm, key parameters of the L-band radiative transfer model, including soil roughness, scattering albedo, and a (seasonally varying) climatology of vegetation opacity, are obtained from the SMAP Level-2 Radiometer retrieval product (Version 5) [1]. Additionally, we also use ground measurements of surface soil moisture and soil temperature from the SMAP core validation sites as in situ reference of soil conditions [2,3]. As part of the L4_SM system calibration, the seasonally-varying bias between the model forecast Tb and the observed values is removed prior to the assimilation of the SMAP Tb observations [7]. That is, the L4_SM system is designed to only correct errors in synoptic-scale and interannual variations from the long-term mean seasonal cycle while maintaining the model’s (potentially erroneous) climatology. The Tb O-F residuals examined here are thus computed using SMAP Tb observations after they are rescaled to the mean seasonal cycle of Tb from the modeling system without SMAP data assimilation. Consequently, the long-term average of the Tb O-F residuals has a global mean of only 0.13 K and locally small values, ranging from -1 to 3 K. Despite the small time-average values of the Tb O-F residuals, the model forecast Tb was nevertheless found to exhibit undesirable systematic errors. At some locations, the time-average Tb O-F values strongly depend on surface soil moisture (SM). At the Yanco SMAP core validation site, for example, the Tb O-F residuals typically range from 5 to 15 K under dry soil moisture conditions (SM < 0.15 m3 m-3) yet are predominantly negative under wet soil moisture conditions (SM > 0.25 m3 m-3), with values ranging from 0 to -40 K. This results in soil moisture analysis increments that persistently make the soil drier under dry SM conditions and persistently make the soil wetter under wet SM conditions, suggesting an error in the dynamic range of the simulated Tb, soil moisture or soil temperature. In this paper, we describe the higher-order systematic Tb forecast errors in more detail, examine their impact on the L4_SM product quality, and explore potential avenues to further improve the L4_SM algorithm.

Rolf Reichle↗

Modal Correction Method For Dynamically Induced Errors In Wind-Tunnel Model Attitude Measurements

This paper describes a method for correcting the dynamically induced bias errors in wind tunnel model attitude measurements using measured modal properties of the model system. At NASA Langley Research Center, the predominant instrumentation used to measure model attitude is a servo-accelerometer device that senses the model attitude with respect to the local vertical. Under smooth wind tunnel operating conditions, this inertial device can measure the model attitude with an accuracy of 0.01 degree. During wind tunnel tests when the model is responding at high dynamic amplitudes, the inertial device also senses the centrifugal acceleration associated with model vibration. This centrifugal acceleration results in a bias error in the model attitude measurement. A study of the response of a cantilevered model system to a simulated dynamic environment shows significant bias error in the model attitude measurement can occur and is vibration mode and amplitude dependent. For each vibration mode contributing to the bias error, the error is estimated from the measured modal properties and tangential accelerations at the model attitude device. Linear superposition is used to combine the bias estimates for individual modes to determine the overall bias error as a function of time. The modal correction model predicts the bias error to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment.

Buehrle, R. D.↗

Deuterium in the Local Interstellar Medium: Its Cosmological Significance

We report on our ongoing program to measure the deuterium/hydrogen (D/H) ratio and interstellar gas properties along many lines of sight through the local interstellar medium using the HST Goddard High-Resolution Spectrograph. For the line of sight towards Capella (12.5 pc) we had previously found D/H = 1.65(+0.07, -0.18) x 10(exp -5), T = 7000 K, and turbulent velocity 1.66 km/s. These quantities were determined by modeling the interstellar hydrogen and deuterium Lyman alpha lines and the resonance lines of Fe II and Mg II against the background stellar emission-line profiles. We now report on our preliminary analysis of these spectral lines for the line of sight toward Procyon (3.5 pc). We find that D/H = 1.40 +/- 0.05 x 10(exp -5) (+/- 3 sigma) photometric random errors only), which is lower than but perhaps consistent with the value of D/H derived for the Capella line of sight when the systematic errors associated with the uncertain intrinsic Procyon emission line are included. Further analysis of this and other lines of sight are planned to determine whether the D/H ratio varies within the local interstellar medium. We infer the primordial value of D/H from Galactic evolution models and comment on the derived baryon density of the Universe.

Linsky, Jeffrey L.↗

Constraint energy minimizing generalized multiscale finite element method for multi-continuum Richards equations

In fluid flow simulation, the multi-continuum model is a useful strategy. When the heterogeneity and contrast of coefficients are high, the system becomes multiscale, and some kinds of reduced order methods are demanded. Combining these techniques with nonlinearity, we will consider in this paper a dual-continuum model which is generalized as a multi-continuum model for a coupled system of nonlinear Richards equations as unsaturated flows, in complex heterogeneous fractured porous media; and we will solve it by a novel multiscale approach utilizing the constraint energy minimizing generalized multiscale finite element method (CEM-GMsFEM). In particular, such a nonlinear system will be discretized in time and then linearized by Picard iteration (whose global convergence is proved theoretically). Subsequently, we tackle the resulting linearized equations by the CEM-GMsFEM and obtain proper offline multiscale basis functions to span the multiscale space (which contains the pressure solution). More specifically, we first introduce two new sources of samples, and the GMsFEM is used over each coarse block to build local auxiliary multiscale basis functions via solving local spectral problems, that are crucial for detecting high-contrast channels. Second, per oversampled coarse region, local multiscale basis functions are created through the CEM as constrainedly minimizing an energy functional. Various numerical tests for our approach reveal that the error converges with the coarse-grid size and that only few oversampling layers as well as basis functions are needed.

97 MATHEMATICS AND COMPUTING↗

GRAVITATIONAL POTENTIAL ENVIRONMENT OF GALAXIES. I. SIMULATION

We extend the concept of galaxy environment from the local galaxy number density to the gravitational potential and its functions like the shear tensor. For this purpose, we examine whether or not one can make an accurate estimation of the gravitational potential from an observational sample which is finite in volume, biased due to galaxy biasing, and subject to redshift space distortion. Dark halos in a {Lambda}CDM simulation are used in this test. We find that one needs to stay away from the sample boundaries by more than 30 h {sup -1} Mpc to reduce the error within 20% of the rms values of the potential or the shear tensor. The error due to the galaxy biasing can be significantly reduced by using the galaxy mass density field instead of the galaxy number density field. The error caused by the redshift space distortion can be effectively removed by correcting galaxy positions for the peculiar velocity effects. We inspect the dependence of dark matter halo properties on four environmental parameters: local density, gravitational potential, and the ellipticity, and prolateness of the shear tensor. We find that the local density has the strongest correlation with halo properties. This is evident that the internal physical properties of dark halos are mainly controlled by small-scale physics. In high-density regions dark halos are on average more massive and spherical and have higher spin parameter and velocity dispersion. We also study the relation between the environmental parameters and the subtypes of dark halos. The spin parameter of satellite halos depends only weakly on the local density for all mass ranges studied, while that of isolated or central halos depends more sensitively on the local density. The gravitational potential and the shear tensor have weaker correlations with halo properties, but have environmental information independent of the local density.

79 ASTRONOMY AND ASTROPHYSICS↗

ULTRA-effective labeling of tandem repeats in genomic sequence

In the age of long read sequencing, genomics researchers now have access to accurate repetitive DNA sequence (including satellites) that, due to the limitations of short read-sequencing, could previously be observed only as unmappable fragments. Tools that annotate repetitive sequence are now more important than ever, so that we can better understand newly uncovered repetitive sequences, and also so that we can mitigate errors in bioinformatic software caused by those repetitive sequences. To that end, we introduce the 1.0 release of our tool for identifying and annotating locally repetitive sequence, ULTRA Locates Tandemly Repetitive Areas (ULTRA). ULTRA is fast enough to use as part of an efficient annotation pipeline, produces state-of-the-art reliable coverage of repetitive regions containing many mutations, and provides interpretable statistics and labels for repetitive regions.

59 BASIC BIOLOGICAL SCIENCES↗

Simulating plasma wave propagation on a superconducting quantum chip

Quantum computers may one day enable the efficient simulation of strongly coupled plasmas that lie beyond the reach of classical computation in regimes where quantum effects are important and the scale separation is large. Here, in this article, we take a first step toward efficient simulation of quantum plasmas by demonstrating linear plasma wave propagation on a superconducting quantum chip. Using high-fidelity and highly expressive device-native gates, combined with an error-mitigation technique, we simulate the scattering of laser pulses from inhomogeneous plasmas. Our approach is made feasible by the identification of a suitable local spin model whose excitations mimic plasma waves, and whose circuit implementation requires a lower gate count than other proposed approaches that would require a future fault-tolerant quantum computer. This work opens avenues to study more complicated phenomena that cannot be simulated efficiently on classical computers, such as nonlinear quantum dynamics when strongly coupled plasmas are driven out of equilibrium.

general physics↗

Local entanglability and multipartite entanglement

We introduce a physically motivated classification of pure quantum states describing n qubits. We characterize all multipartite states which can be maximally entangled to local auxiliary systems using controlled operations. A state has this property if and only if one can construct out of it an orthonormal basis by applying independent local unitary operations. This implies that those states can be used to encode locally the maximum amount of n independent bits. Examples of these states are the so-called stabilizer states, which are used for quantum error correction and one-way quantum computing. We give a simple characterization of these states and construct a complete set of commuting unitary observables which characterize the state uniquely. Furthermore we show how these states can be prepared and discuss their applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring the Loschmidt Amplitude for Finite-Energy Properties of the Fermi-Hubbard Model on an Ion-Trap Quantum Computer

Calculating the equilibrium properties of condensed-matter systems is one of the promising applications of near-term quantum computing. Recently, hybrid quantum-classical time-series algorithms have been proposed to efficiently extract these properties from a measurement of the Loschmidt amplitude ⟨ ψ | e − i H ^ t | ψ ⟩ from initial states | ψ ⟩ and a time evolution under the Hamiltonian H ^ up to short times t . In this work, we study the operation of this algorithm on a present-day quantum computer. Specifically, we measure the Loschmidt amplitude for the Fermi-Hubbard model on a 16 -site ladder geometry (32 orbitals) on the Quantinuum H2-1 trapped-ion device. We assess the effect of noise on the Loschmidt amplitude and implement algorithm-specific error-mitigation techniques. By using a thus-motivated error model, we numerically analyze the influence of noise on the full operation of the quantum-classical algorithm by measuring expectation values of local observables at finite energies. Finally, we estimate the resources needed for scaling up the algorithm. Published by the American Physical Society 2024

Physics↗

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.

60 APPLIED LIFE SCIENCES↗

Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy

Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r{sub s}) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI{sub SPORT}) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r{sub s} values of contrast to the global gamma passing rates with criteria of 2%/2 mm, 2%/1 mm, and 1%/2 mm were 0.536, 0.473, and 0.718, respectively. The respective values for variance were 0.551, 0.481, and 0.688. In the case of local gamma passing rates, the r{sub s} values of contrast were 0.547, 0.578, and 0.620, respectively, and those of variance were 0.519, 0.527, and 0.569. All of the r{sub s} values in those cases were statistically significant (p < 0.003). In the cases of global and local gamma passing rates, MI{sub SPORT} showed the highest correlations among the conventional modulation indices. For global passing rates, r{sub s} values of MI{sub SPORT} were −0.420, −0.330, and −0.632, respectively, and those for local passing rates were −0.455, −0.490 and −0.502. The values of r{sub s} of contrast, variance, and MI{sub SPORT} with the MLC errors were −0.863, −0.828, and 0.795, respectively, all with statistical significances (p < 0.001). The correlations with statistical significances between variance and dose-volumetric differences were observed more frequently than the others. Conclusions: The contrast (d = 1) and variance (d = 1) calculated from fluence maps of VMAT plans showed considerable correlations with the plan deliverability, indicating their potential use as indicators for assessing the degree of modulation of VMAT plans. Both contrast and variance consistently showed better performance than the conventional modulation indices for VMAT.

60 APPLIED LIFE SCIENCES↗

Optimal Control of a Surge-Mode WEC in Random Waves

The objective of this project was to develop one or more real-time feedback and feed-forward (MPC) control algorithms for an Oscillating Surge Wave Converter (OSWC) developed by RME called SurgeWEC™ that leverages recent innovations in wave energy converter (WEC) control theory to maximize power production in random wave environments. The control algorithms synthesized innovations in dynamic programming and nonlinear wave dynamics using anticipatory wave sensors and localized sensor measurements; e.g. position and velocity of the WEC Power Take Off (PTO), with predictive wave forecasting data. The result was an advanced control system that uses feedback or feed-forward data from an array of sensor channels comprised of both localized and deployed sensors fused into a single decision process that optimally compensates for uncertainties in the system dynamics, wave forecasts, and sensor measurement errors.

16 TIDAL AND WAVE POWER↗

Evaluating simplifications of subsurface process representations for field-scale permafrost hydrology models

Abstract. Permafrost degradation within a warming climate poses a significant environmental threat through both the permafrost carbon feedback and damage to human communities and infrastructure. Understanding this threat relies on better understanding and numerical representation of thermo-hydrological permafrost processes and the subsequent accurate prediction of permafrost dynamics. All models include simplified assumptions, implying a tradeoff between model complexity and prediction accuracy. The main purpose of this work is to investigate this tradeoff when applying the following commonly made assumptions: (1) assuming equal density of ice and liquid water in frozen soil, (2) neglecting the effect of cryosuction in unsaturated freezing soil, and (3) neglecting advective heat transport during soil freezing and thaw. This study designed a set of 62 numerical experiments using the Advanced Terrestrial Simulator (ATS v1.2) to evaluate the effects of these choices on permafrost hydrological outputs, including both integrated and pointwise quantities. Simulations were conducted under different climate conditions and soil properties from three different sites in both column- and hillslope-scale configurations. Results showed that amongst the three physical assumptions, soil cryosuction is the most crucial yet commonly ignored process. Neglecting cryosuction, on average, can cause 10 %–20 % error in predicting evaporation, 50 %–60 % error in discharge, 10 %–30 % error in thaw depth, and 10 %–30 % error in soil temperature at 1 m beneath the surface. The prediction error for subsurface temperature and water saturation is more obvious at hillslope scales due to the presence of lateral flux. By comparison, using equal ice–liquid density has a minor impact on most hydrological metrics of interest but significantly affects soil water saturation with an averaged 5 %–15 % error. Neglecting advective heat transport presents the least error, 5 % or even much lower, in most metrics of interest for a large-scale Arctic tundra system without apparent influence caused by localized groundwater flow, and it can decrease the simulation time at hillslope scales by 40 %–80 %. By challenging these commonly made assumptions, this work provides permafrost hydrology scientists an important context for understanding the underlying physical processes, including allowing modelers to better choose the appropriate process representation for a given modeling experiment.

54 ENVIRONMENTAL SCIENCES↗

Hyperbola-generator for location of aperiodic events

Plotting device, when used in conjunction with three or more detectors and local receiver and recorder, can quickly pinpoint location of any aperiodic event. Operation requires minimal training and is readily adapted to the field. Mechanical error in device prototype is less than or equal to 3 percent.

Paucker, H. R.↗