Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Intercell Power Transformer for Power Balancing of Polyphase Wireless Power Transfer Systems

Polyphase wireless power transfer (PWPT) systems experience receiver side imbalances in misaligned conditions. This paper proposes a method for power balancing in PWPT systems, specifically addressing the challenges caused by receivers coil unequal coupling. An intercell power transformer (IPT) is introduced at the receiver side to mitigate the effects of coil mismatch. Simulations of the PWPT system incorporating IPT demonstrate its effectiveness in enhancing power distribution. For voltage-fed rectifiers (VFR), the IPT increases the conduction angle, resulting in higher output power. In current- fed rectifiers (CFR), the IPT promotes uniform power sharing among rectifiers, thereby reducing electrical stress on semiconductor devices and passive components. Simulation results indicate that, under coil misalignment, the IPT improves output power by approximately 49% for VFRs and 44% for CFRs compared to conventional PWPT systems without IPT.

Wojda, Rafal [ORNL] (ORCID:0000000286609268)↗

Effects of a Parallel Electric Field and the Geomagnetic Field in the Topside Ionosphere on Auroral and Photoelectron Energy Distributions

The consequences of electric field acceleration and an inhomogencous magnetic field on auroral electron energy distributions in the topside ionosphere are investigated. The one- dimensional, steady state electron transport equation includes elastic and inelastic collisions, an inhomogencous magnetic field, and a field-aligned electric field. The case of a self-consistent polarization electric field is considered first. The self-consistent field is derived by solving the continuity equation for all ions of importance, including diffusion of 0(+) and H(+), and the electron and ion energy equations to derive the electron and ion temperatures. The system of coupled electron transport, continuity, and energy equations is solved numerically. Recognizing observations of parallel electric fields of larger magnitude than the baseline case of the polarization field, the effect of two model fields on the electron distribution function in investigated. In one case the field is increased from the polarization field magnitude at 300 km to a maximum at the upper boundary of 800 km, and in another case a uniform field is added to the polarization field. Substantial perturbations of the low energy portion of the electron flux are produced: an upward directed electric field accelerates the downward directed flux of low-energy secondary electrons and decelerates the upward directed component. Above about 400 km the inhomogencous magnetic field produces anisotropies in the angular distribution of the electron flux. The effects of the perturbed energy distributions on auroral spectral emission features are noted.

Min, Q.-L.↗

Using concentrating-solar-power plants as economic carbon-free capacity resources

Deep decarbonization of electricity systems raises concerns about the need for generating capacity that can maintain reliable energy supply. Given this concern, we explore the ability of concentrating-solar-power plants with thermal energy storage to provide a carbon-free source of such capacity. We develop an approach to assessing the capacity contribution of concentrating-solar-power plants that considers future systems. Such considerations are important, because of potential differences in net-load patterns compared to today (e.g., due to higher renewable-energy penetrations). Using historical data spanning an 18-year period, we demonstrate that concentrating-solar-power plants with thermal energy storage can provide this necessary capacity with little impact on their financial viability. We examine the impact of myopic decisions and imperfect foresight of future system conditions on the operation of concentrating-solar-power plants and the resultant impact on their capacity contributions. We find that imperfect foresight can have limited impacts on such a use of concentrating-solar-power plants, so long as proper forecasting techniques are developed and used. Overall, our work shows that concentrating-solar-power plants with thermal energy storage may have a role to play in delivering reliable electricity supply in a decarbonized energy system.

14 SOLAR ENERGY↗

Effects of a parallel electric field and the geomagnetic field in the topside ionosphere on auroral and photoelectron energy distributions

The consequences of electric field acceleration and an inhomogeneous magnetic field on auroral electron energy distributions in the topside ionosphere are investigated. The one-dimensional, steady state electron transport equation includes elastic and inelastic collisions, an inhomogeneous magnetic field, and a field-aligned electric field. The case of a self-consistent polarization electric field is considered first. The self-consistent field is derived by solving the continuity equation for all ions of importance, including diffusion of O(+) and H(+), and the electron and ion energy equations to derive the electron and ion temperatures. The system of coupled electron transport, continuity, and energy equations is solved numerically. Recognizing observations of parallel electric fields of larger magnitude than the baseline case of the polarization field, the effect of two model fields on the electron distribution function is investigated. In one case the field is increased from the polarization field magnitude at 300 km to a maximum at the upper boundary of 800 km, and in another case a uniform field is added to the polarization field. Substantial perturbations of the low energy portion of the electron flux are produced: an upward directed electric field accelerates the downward directed flux of low-energy secondary electrons and decelerates the upward directed component. Above about 400 km the inhomogeneous magnetic field produces anisotropies in the angular distribution of the electron flux. The effects of the perturbed energy distributions on auroral spectral emission features are noted.

Min, Q.-L.↗

Systems and methods for advanced grid integration of distributed generators and energy resources

A circuit for a smart photovoltaic (PV) inverter system and the smart PV inverter system are described. The circuit includes one or more strings coupled to an electrical load. Each of the one or more strings further includes one or more string members coupled in series, where each of the one or more string members comprises a voltage source and an inverter. The circuit also includes a controller to receive an output from an operator controller and control the strings, where the controller is configured to control the strings by providing a function command to a first string member of each of the one or more strings based on the output from the operator controller. The voltage source may also receive an output from an energy output device. Further, the inverter may be configured to convert the output of energy output device into an energy source of electrical load.

Bhowmik, Shibashis↗

Microgrid Fast Charging Station (MFCS) Design Platform Project (Summary Report)

This report documents the important steps and outcomes of the Microgrid Fast Charging Station (MFCS) Design Platform project, executed by XENDEE Corporation and its testing and validation by Idaho National Laboratory (INL). This final summary report builds on the first summary released on April 30th, 2021 and adds the final results from the Hardware in the Loop (HIL) simulations and tests, which have been completed July 14th 2021. With this report XENDEE Corporation and Idaho National Laboratory conclude the first version of the Microgrid Fast Charging Station (MFCS) Design Platform as well as all related tests and validations for two in-depth case studies for islanded and non-islanded operation. The platform itself utilizes XENDEE’s advanced modeling systems and INL’s HIL system to ensure project viability and technical feasibility. It also intelligently maps all cables, transformers, and distributed technology interactions to anticipate and mitigate problems during peak usage or adverse conditions. Finally, the system is designed to optimize dispatch and generation at each time step of the day allowing the Microgrid to take advantage of energy sales to the utility and best manage the charging of an electrical fleet. This allows operators to reliably build bankable Microgrid systems and to operate them to reach the maximum efficiency even under the dynamic needs of electric vehicle fast charging

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

A Scalable and Distributed Algorithm for Managing Residential Demand Response Programs using Alternating Direction Method of Multipliers (ADMM)

For effective engagement of residential demand-side resources and to ensure efficient operation of distribution networks, we must overcome the challenges of controlling and coordinating residential components and devices at scale. To overcome this challenge, we present a distributed and scalable algorithm with a three-level hierarchical information exchange architecture for managing the residential demand response programs. First, a centralized optimization model is formulated to maximize community social welfare. Then, this centralized model is solved in a distributed manner with alternating direction method of multipliers (ADMM) by decomposing the original problem to utility-level and house-level problems. The information exchange between the different layers is limited to the primary residual (i.e., supply-demand mismatch), Lagrangian multipliers, and the total load of each house to protect each customer’s privacy. Simulation studies are performed on the IEEE 33 bus test system with 605 residential customers. The results demonstrate that the proposed approach can save customers’ electricity bills and reduce the peak load at the utility level without much affecting customers’ comfort and privacy. Finally, a quantitative comparison of the distributed and centralized algorithms shows the scalability advantage of the proposed ADMM-based approach, and it gives benchmarking results with achievable value for future research works.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Can Wholesale Electricity Markets Achieve Resource Adequacy and High Clean Energy Generation Targets in the Presence of Self-Interested Actors?

Wholesale electricity markets are intended to incentivize system generation investments and operations outcomes that meet evolving system needs. In this work, we evaluate the effectiveness of wholesale market structures, rules and policies in achieving system resource adequacy (RA) and clean energy targets in the presence of self-interested generation investors using the Electricity Markets and Investment Suite Agent-based Simulation (EMIS-AS) model. Results highlight that both capacity markets and operating reserve demand curves (ORDCs) can help achieve a reliable system but with different RA compliance timelines and distribution of generation technologies. Structures with capacity markets tend to favor more capital-intensive peaking technologies while reducing wind and solar build-outs due to suppressed energy and clean energy market prices, particularly in the absence of strong clean energy targets. Conversely, ORDCs improve the commitment of available generation units, but this comes at the expense of higher system costs and renewable generation curtailment. We also find that well-calibrated static capacity demand curves can yield similar reliability and total cost compared to capacity market demand curves informed dynamically by resource adequacy while also yielding stable annual capacity prices. Different approaches to formulating ORDC curves can also yield key trade-offs, namely that a more efficient treatment of storage chronology results in lower ORDC curves and prices, yielding less investment and cost but at the expense of reliability. Finally, the effectiveness of wholesale electricity markets in practically achieving very high clean energy generation targets highly depends on the cost-competitiveness of clean energy technologies that can support critical balancing needs across multiple timescales.

capacity expansion↗

A Two-Stage Approach for PV Inverter Engagement in Power Factor Correction and Voltage Regulation

The rapid integration of distributed energy resources, like solar photovoltaics (PVs), can lead to overvolt-age challenges due to reverse power flow and a noticeable decrease in power factor at the substation interface. While existing literature extensively explores utilizing smart inverter capabilities for reactive power flexibility using a volt-var curve (VVC), obtaining time-varying operating points of such curves in real-time is challenging due to computational demands and communication requirements. Similarly, employing optimization-based approaches for reactive power control and active voltage regulation in large-scale distribution feeders is difficult due to the complexity of the problem and the challenges in effectively engaging customer-owned resources. This paper proposes a two-stage strategy to harness smart inverters for reactive power support. The first stage formulates short-term planning by optimally designing VVCs (on a daily or hourly basis) for large-scale solar PVs based on projected system needs and communicating optimal curves to smart inverters in advance. Subsequently, the second stage employs a transactive-based method to involve customer-owned PVs for reactive power support, effectively enhancing overall system performance and addressing real-time demands. In conclusion, the efficacy of this approach will be demonstrated using real-world distribution circuits provided by Vermont Electric Power Company (VELCO) and Vermont Electric Cooperative (VEC).

Poudel, Shiva [Pacific Northwest National Laborato↗

Overview of Potential Hazards in Electric Aircraft Charging Infrastructure

With increasing efforts in electrification of Advanced Air Mobility and electric aircraft, there is a growing need to install new infrastructure to support them. This report highlights potential hazards (non exhaustive) that the installation must be aware of and be prepared to mitigate with increased electrical equipment on site. The hazards can be due to natural causes as well as non natural causes. The report aims to provide starting guidelines for awareness of these hazards and to help plan for mitigation of the same.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Automated distribution system management for multichannel space power systems

A NASA sponsored study of space power distribution system technology is in progress to develop an autonomously managed power system (AMPS) for large space power platforms. The multichannel, multikilowatt, utility-type power subsystem proposed presents new survivability requirements and increased subsystem complexity. The computer controls under development for the power management system must optimize the power subsystem performance and minimize the life cycle cost of the platform. A distribution system management philosophy has been formulated which incorporates these constraints. Its implementation using a TI9900 microprocessor and FORTH as the programming language is presented. The approach offers a novel solution to the perplexing problem of determining the optimal combination of loads which should be connected to each power channel for a versatile electrical distribution concept.

Fleck, G. W.↗

Paschen Considerations for High Altitude Airships

Recently, there have been several proposals submitted to funding agencies for long-lived high altitude (about 70,000 feet) airships for communications, surveillance, etc. In order for these airships to remain at altitude, high power, high efficiency, lightweight solar arrays must be used, and high efficiency power management and distribution systems must be employed. The needs for high power and high efficiency imply high voltage systems. However, the air pressure at these extreme altitudes is such that electrical power systems will be near the Paschen discharge minimum over a wide range of electrode separations. In this paper, preliminary calculations are made for acceptable high voltage design practices under ambient, hydrogen and helium gas atmospheres.

Ferguson, D. C.↗

Lunar Reconnaissance Orbiter (LRO) Command and Data Handling Flight Electronics Subsystem

A document describes a high-performance, modular, and state-of-the-art Command and Data Handling (C&DH) system developed for use on the Lunar Reconnaissance Orbiter (LRO) mission. This system implements a complete hardware C&DH subsystem in a single chassis enclosure that includes a processor card, 48 Gbytes of solid-state recorder memory, data buses including MIL-STD-1553B, custom RS-422, SpaceWire, analog collection, switched power services, and interfaces to the Ka-Band and S-Band RF communications systems. The C&DH team capitalized on extensive experience with hardware and software with PCI bus design, SpaceWire networking, Actel FPGA design, digital flight design techniques, and the use of VxWorks for the real-time operating system. The resulting hardware architecture was implemented to meet the LRO mission requirements. The C&DH comprises an enclosure, a backplane, a low-voltage power converter, a single-board computer, a communications interface board, four data storage boards, a housekeeping and digital input/output board, and an analog data acquisition board. The interfaces between the C&DH and the instruments and avionics are connected through a SpaceWire network, a MIL-STD-1553 bus, and a combination of synchronous and asynchronous serial data transfers over RS-422 and LVDS (low-voltage differential-signaling) electrical interfaces. The C&DH acts as the spacecraft data system with an instrument data manager providing all software and internal bus scheduling, ingestion of science data, distribution of commands, and performing science operations in real time.

Nguyen, Quang↗

A Framework to Demonstrate a DNP3 Interface With a CIM-Based Data Integration Platform: Preprint

The contemporary electrical grid is characterized by its complexity and abundance of data. A control-rich environment supported by information and communication technologies within an Advanced Distribution Management System (ADMS) presents a viable and cost-effective option for utility companies aiming to implement advanced real-time analytical schemes for monitoring and remotely controlling distribution feeders. Modular platform-based approaches to distribution operations require a structured framework for acquiring field device measurements, performing analytics, converting the setpoint to the correct protocol, and sending it on the appropriate communications network to the field devices. We present the development and deployment of an application service to integrate an open-source standardsbased platform with an ADMS test bed with field devices using the Distributed Network Protocol (DNP3) for data exchange. The step-by-step procedure for establishing the DNP3-Master service on an open-source distribution platform is outlined, comprehensively explaining the Master setup process. Moreover, sample use case results highlight the capabilities of the DNP3- Master service setup. Results demonstrate the scalability and configurability of the DNP3-Master service, making it adaptable for integration with other relevant applications, thus providing potential opportunities for real-world field trials and real-time assessments.

ADMS↗