At least 1,333 records · Page 74

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Laser altimetry measurements from aircraft and spacecraft

The techniques involved in the design and application of laser altimeter instruments are reviewed, including a description of the instrument subsystems required for the range and waveform measurements. Laser pulse transmitters based on the relatively novel technology of diode-pumped solid-state lasers are considered. Various factors affecting laser altimeter instrument performance are discussed. These include the receiver signal-to-noise ratio, atmospheric propagation, and altimeter platform effects. Some examples of laser altimeter data are presented to illustrate the variety of possible instrument applications.

Bufton, Jack L.↗

A Characterization Of Alcohol Fuel Vapor For Wavelength Modulation Spectroscopy Applied To Microgravity Flame Spread

A diode laser diagnostic is being developed for use in an ongoing investigation of flame spread in microgravity at NASA Glenn Research Center. Flame spread rates through non-homogenous gas mixtures are significantly different in a microgravity environment because of buoyancy and possibly hydrostatic pressure effects. These effects contribute to the fuel vapor concentration ahead of the flame being altered so that flame spread is more rapid in microgravity. This paper describes spectral transmission measurements made through mixtures of alcohol, water vapor, and nitrogen in a gas cell that was designed and built to allow measurements at temperatures up to 500 C. The alcohols considered are methanol, ethanol, and n-propanol. The basic technique of wavelength modulation spectroscopy for gas species measurements in microgravity was developed by Silver et al. For this technique to be applicable, one must carefully choose the spectral features over which the diode laser is modulated to provide good sensitivity and minimize interference from other molecular lines such as those in water. Because the methanol spectrum was not known with sufficient resolution in the wavelength region of interest, our first task was to perform high-resolution transmission measurements with an FTIR spectrometer for methanol vapor in nitrogen, followed recently by ethanol and n-propanol. A computer program was written to generate synthesized data to mimic that expected from the experiment using the laser diode, and results from that simulation are also presented.

Kulis, Michael J.↗

SU-F-T-326: Diode Array Transmission Detector Systems Evaluation

Purpose: A new transmission detector, Delta4 Discover, developed by Scandidos (Uppsala, Sweden) was evaluated for external photon beam verification and quality assurance. The device is an array of 4040 diodes designed to be mounted on the linac accessory tray to measure photon field shape, position and fluence during patient treatment. Interfractional measurements are compared to a baseline measurement made during delivery quality assurance. The aim of this work is to evaluate the stability of the device and its effect on the shape and magnitude of the treatment beam. Methods: Beam profiles, percent depth dose, and beam attenuation was measured for 6, 10, and 15 MV photon beams with and without the device in place for 1×1 and 30×30 cm2 fields. Changes in profile and percent depth dose was quantified to evaluate the need to recommission the treatment beam, or account for the device with a tray factor. The stability of the radiation measurements was evaluated by measuring the deviation of each diode measurement during repeated prostate VMAT treatment delivery. Results: Photon beam profiles changed by < 1.25% in the nonpenumbra regions of the 30×30 cm2 beam. Percent depth dose curves show a 5–7% increased dose at depths < 2.5cm, but agreed within 1% at depths > 2.5cm. This indicates increased skin dose, similar to the use of a physical beam wedge. The device attenuated 6, 10, and 15 MV photon beams by 1.71±0.02%, 1.36±0.03%, and 1.17±0.03%, respectively. The diode array reproduced dosimetric measurements within 0.5% standard deviation for repeated prostate VMAT measurement. Conclusion: The device demonstrated stabile radiation measurements, while not changing the treatment beam shape in a clinically significantly manner. Use of this device can be accounted for with a tray factor, as opposed to recommissioning the treatment beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical, optical, and material characterizations of blue InGaN light emitting diodes submitted to reverse-bias stress in water vapor condition

In this paper, we investigate degradation of InGaN/GaN light emitting diodes (LEDs) under reverse-bias operations in water vapor and dry air. To examine failure origins, electrical characterizations including current-voltage, breakdown current profiles, optical measurement, and multiple material analyses were performed. Our findings indicate that the diffusion of indium atoms in water vapor can expedite degradation. Investigation of reverse-bias stress can help provide insight into the effects of water vapor on LEDs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗

Effect of active-region “volume” on the radiative properties of laser heterostructures with radiation output through the substrate

The radiative properties of InGaAs/GaAs/InGaP laser structures with radiation output through the substrate depending on the number of quantum wells in the active region and laser diodes on their basis are investigated. It is established that the presence of six–eight quantum wells in the active region is optimum from the viewpoint of observable values of the threshold current and the output optical power of lasers.

36 MATERIALS SCIENCE↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Annual Conference on Nuclear and Space Radiation Effects, 14th, College of William and Mary, Williamsburg, Va., July 12-15, 1977, Proceedings

Topics related to processing and hardness assurance are considered, taking into account the radiation hardening of CMOS technologies, technological advances in the manufacture of radiation-hardened CMOS integrated circuits, CMOS hardness assurance through process controls and optimized design procedures, the application of operational amplifiers to hardened systems, a hard off-the-shelf SG1524 pulse width modulator, and the gamma-induced voltage breakdown anomaly in a Schottky diode. Basic mechanisms are examined, giving attention to chemical and structural aspects of the irradiation behavior of SiO2 films on silicon, experimental observations of the chemistry of the SiO2/Si interface, leakage current phenomena in irradiated SOS devices, the avalanche injection of holes into SiO2, the low-temperature radiation response of Al2O3 gate insulators, and neutron damage mechanisms in silicon at 10 K. Other subjects discussed are related to radiation effects in devices and circuits, space radiation effects, and aspects of simulation, energy deposition, and dosimetry.

Stahl, R. H.↗

Photoluminescent properties and Judd–Ofelt analysis of novel Na0.5Sr0.25NbO3: Eu3+ red phosphor with high quantum efficiency

Highlights: • The Na{sub 0.5}Sr{sub 0.25}NbO{sub 3}: Eu{sup 3+} phosphor with high quantum efficiency has been successfully synthesized by using a molten salt synthesis method. • The effect of the crystal field surrounding the Eu{sup 3+} ions on the luminescent performance was analyzed by the Judd–Ofelt theory. • Photoluminescent properties of Na{sub 0.5}Sr{sub 0.25}NbO{sub 3}: Eu{sup 3+} phosphor were investigated for the first time. - Abstract: We report on a novel Na{sub 0.5}Sr{sub 0.25}NbO{sub 3}: Eu{sup 3+} phosphor fabricated by a molten salt synthesis method with the potential application in white light-emitting diodes (WLEDs) as a red phosphor. The crystal structure, morphology, emission/excitation spectra, as well as decay curves were characterized with X-ray diffraction, Scanning Electron Microscope and photoluminescence spectrometer, respectively. Concentration quenching occurred when the concentration of Eu{sup 3+} was beyond 5 mol% due to the dipole-dipole interaction by nonradiative energy transfer. Besides, the effect of the crystal field surrounding the Eu{sup 3+} ions on the luminescent performance under 396 nm and 466 nm excitions has been investigated by the Judd–Ofelt theory. The result indicated that the quantum efficiency of the phosphor was 62.65% excited by 466 nm, which was superior to 41.43% excited by 396 nm. The optimal sample’s CIE coordinates were (0.6471, 0.3504) with the color purity of 97%, showing a potential application in (WLEDs) illumination field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A device adaptive inflow boundary condition for Wigner equations of quantum transport

In this paper, an improved inflow boundary condition is proposed for Wigner equations in simulating a resonant tunneling diode (RTD), which takes into consideration the band structure of the device. The original Frensley inflow boundary condition prescribes the Wigner distribution function at the device boundary to be the semi-classical Fermi–Dirac distribution for free electrons in the device contacts without considering the effect of the quantum interaction inside the quantum device. The proposed device adaptive inflow boundary condition includes this effect by assigning the Wigner distribution to the value obtained from the Wigner transform of wave functions inside the device at zero external bias voltage, thus including the dominant effect on the electron distribution in the contacts due to the device internal band energy profile. Numerical results on computing the electron density inside the RTD under various incident waves and non-zero bias conditions show much improvement by the new boundary condition over the traditional Frensley inflow boundary condition.

97 MATHEMATICS AND COMPUTING↗

Colloidal cobalt-doped ZnO nanoparticles by microwave-assisted synthesis and their utilization in thin composite layers with MEH-PPV as an electroluminescent material for polymer light emitting diodes

In this study, Co x Zn 1-x O (x = 0.01, 0.05 and 0.1) nanoparticles were prepared by microwave-assisted polyol method from zinc acetate dihydrate and Co(II) acetylacetonate. The reactions were performed in diethylene glycol (DEG) at 250 °C with the use of oleic acid as a surfactant. Resulting nanoparticle (ca. 10 nm) precipitates were washed with methanol and dried or kept as colloidal solutions redispersed in toluene. Colloidal solutions were mixed with the Poly [2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV) polymer to produce thin nanocomposite layers with specific optoelectronic properties. The electronic structure in terms of density of states (DOS) of MEH-PPV and MEH-PPV/nanocomposite layers was investigated by recently proposed energy resolved electrochemical impedance spectroscopy method. The MEH-PPV polymer and its nanocomposites with ZnO or Co x Zn 1-x O nanoparticles were used as thin active layers in polymer light emitting diodes (PLED). The nanocomposite layers exhibited optoelectronic properties which were found to be beneficial as the active layer in PLEDs, exhibiting an order of magnitude enhancement in electroluminescence intensity. Finally, a pronounced effect on the opening bias voltage of final devices with Co x Zn 1-x O nanoparticles was also observed.

36 MATERIALS SCIENCE↗

Two Mechanisms Limiting the Emitted Electron Current from a Cathode to an Anode

It is known that the current of emitted electrons flowing through a plasma can saturate upon formation of a potential well adjacent to the cathode (the “space charge effect”). Here, we demonstrate another saturation mechanism that will often set a more restrictive limit on the global current. When “backflow saturation” occurs, the cathode sheath weakens to allow emitted electrons that already entered the plasma to backflow to the cathode. This effect could not be captured by studies modelling the cathode sheath by itself because its origin is coupled to processes in the interior plasma and anode sheath. By modeling a full plasma diode, we show that depending on conditions the global current can be limited in four ways; by backflow alone, by space charge alone, by both mechanisms in a stable cooperative form, or by both in a competing oscillatory form. Published by the American Physical Society 2025

Laboratory plasma↗

Mechanism of dislocation-governed charge transport in schottky diodes based on gallium nitride

A mechanism of charge transport in Au-TiB{sub x}-n-GaN Schottky diodes with a space charge region considerably exceeding the de Broglie wavelength in GaN is studied. Analysis of temperature dependences of current-voltage (I-V) characteristics of forward-biased Schottky barriers showed that, in the temperature range 80-380 K, the charge transport is performed by tunneling along dislocations intersecting the space charge region. Estimation of dislocation density {rho} by the I-V characteristics, in accordance with a model of tunneling along the dislocation line, gives the value {rho} {approx} 1.7 x 10{sup 7} cm{sup -2}, which is close in magnitude to the dislocation density measured by X-ray diffractometry.

36 MATERIALS SCIENCE↗

Fault localization and analysis in semiconductor devices with optical-feedback infrared confocal microscopy

We report on a cost-effective optical setup for characterizing light-emitting semiconductor devices with optical-feedback confocal infrared microscopy and optical beam-induced resistance change.We utilize the focused beam from an infrared laser diode to induce local thermal resistance changes across the surface of a biased integrated circuit (IC) sample. Variations in the multiple current paths are mapped by scanning the IC across the focused beam. The high-contrast current maps allow accurate differentiation of the functional and defective sites, or the isolation of the surface-emittingp-i-n devices in the IC. Optical beam-induced current (OBIC) is not generated since the incident beam energy is lower than the bandgap energy of the p-i-n device. Inhomogeneous current distributions in the IC become apparent without the strong OBIC background. They are located at a diffraction-limited resolution by referencing the current maps against the confocal reflectance image that is simultaneously acquired via optical-feedback detection. Our technique permits the accurate identification of metal and semiconductor sites as well as the classification of different metallic structures according to thickness, composition, or spatial inhomogeneity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epitaxial Growth Development: CRADA Final Report

The purpose of this CRADA is to assist Trumpf Photonics in developing a procedure to grow ZnSe epilayers on the (110) facets of AlGaAs/InGaAs laser diodes that will provide high degrees of electronic passivation and performance reliability. Work will be divided into four tasks: 1) characterization of material growth at Trumpf Photonics, 2) development of a highly effective AlGaAs facet cleaning procedure at NREL, 3) development of a ZnSe epitaxy procedure at NREL, and 4) transfer of the procedures developed at NREL to the Trumpf Photonics site. This CRADA is designed to last 3 years total.

36 MATERIALS SCIENCE↗