Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BTO Market Success Report 2015–2020

This report highlights 28 BTO-supported, technology-oriented research and development (R&D) projects that resulted in the launch of a commercial product, focusing on identifying new technologies or commercialization updates between 2015 and 2020, where the product remained on the market as of March 2021. The report also includes a listing of the full 45 commercial products supported by BTO as well as a listing of 101 lighting components that benefited from BTO support and were commercialized and integrated into finished lighting products during the same timeframe.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Ocean Thermal Energy Conversion (OTEC) Systems for Powering Safety Monitoring Systems of Offshore Oil and Gas Operations. OESI 2.0 M-1 T-1-P1.1 – Objective 1 Interim Report: Summary of Offshore Oil and Gas Well Monitoring Systems and Process Power Requirements

This report is part of a comprehensive research initiative aimed at evaluating the technoeconomic feasibility of deploying greenhouse gas (GHG) emissions monitoring systems powered by small-scale renewable energy sources on the U.S. Outer Continental Shelf (OCS). The study has three primary objectives: summarizing available GHG monitoring systems for the OCS, modeling a renewable marine energy source (specifically ocean thermal energy conversion, or OTEC), and modeling the collocation of OTEC power sources with offshore oil and gas activities to offset power demand.

02 PETROLEUM↗

Electric Grid Visualization: Hourly Renewable Generation, Load, Unserved Load, and Locational Marginal Prices during a Heatwave

Visualization of hourly solar and wind generation, load, unserved load, and locational marginal energy prices in the western United States during a July 22-28 heatwave event in 2018, 2058, and 2098. In addition to hourly time series data of each of the parameters, choropleth maps showing the hourly value for each balancing authority are provided.

Climate Change↗

Accuracy of hourly energy predictions for demand flexibility applications

Decarbonization goals in the United States electricity sector are increasing the levels of renewable energy generation in the electricity supply system, and are driving increased attention to building electrification, which will increase the magnitude and shift the timing of the electricity system peak. These changes are motivating new approaches to coordinate building electricity demand with low-carbon renewable generation, elevating the importance of demand flexibility (DF) in buildings and the need to quantify the temporal impacts of DF. In this paper, we first characterize the hourly predictive accuracy of six commonly used baseline models in an application context of quantifying building-level load shift. Our analysis revealed insights such as hours of the day (afternoons), periods of the week (weekends), and seasons (summer) that were predicted with more accuracy than other time periods. In addition, the analysis showed tendencies toward overprediction or underprediction of load. Secondly, we provide the first published investigation of baseline erosion from repeated dispatch of building load shifting. We observed that as the baseline period is pushed back further from the prediction day, the distribution of errors across baseline model predictions increases, with notable inflection points near the three-week erosion point for two of the three models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Economic Viability of Direct Current Fast Charging Infrastructure Investments for Electric Vehicles in the United States

As the global transportation sector increasingly adopts electric vehicles, the demand for advanced and accessible charging infrastructure is rising. In addition to at-home electric vehicle (EV) charging, there is a growing need for the swift development of commercial direct current fast charging (DCFC) stations to meet on-the-go EV charging demands. While government funds are available to support the expansion of the EV charging network in the United States, the establishment of a robust nationwide EV charging infrastructure requires significant private sector investment. This study was conducted to assess the economic feasibility of various business models for fast charging stations in the U.S. using two case studies and exploring different operational strategies including sole ownership and collaborative ventures with public and private entities. The results indicate that based on the current adoption and utilization rates in the U.S., the business model involving an owner-operator collaborating with a public partner ensures profitability and protects the investment in DCFC stations from financial losses. The study also highlights that demand charges and electricity retail prices are the factors that affect the profitability of a DCFC station.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bioenergy Technologies in Long-Run Climate Change Mitigation: Results from the EMF-33 Study

Bioenergy is expected to play an important role in long-run climate change mitigation strategies as highlighted by many integrated assessment model (IAM) scenarios. These scenarios, however, also show a very wide range of results, with uncertainty about bioenergy conversion technology deployment and biomass feedstock supply. To date, the underlying differences in model assumptions and parameters for the range of results have not been conveyed. Here we explore the models and results of the 33rd study of the Stanford Energy Modeling Forum to elucidate and explore bioenergy technology specifications and constraints that underlie projected bioenergy outcomes. We first develop and report consistent bioenergy technology characterizations and modeling details. We evaluate the bioenergy technology specifications through a series of analyses—comparison with the literature, model intercomparison, and an assessment of bioenergy technology projected deployments. We find that bioenergy technology coverage and characterization varies substantially across models, spanning different conversion routes, carbon capture and storage opportunities, and technology deployment constraints. Still, the range of technology specification assumptions is largely in line with bottom-up engineering estimates. We then find that variation in bioenergy deployment across models cannot be understood from technology costs alone. Important additional determinants include biomass feedstock costs, the availability and costs of alternative mitigation options in and across end-uses, the availability of carbon dioxide removal possibilities, the speed with which large scale changes in the makeup of energy conversion facilities and integration can take place, and the relative demand for different energy services.

bioenergy↗

Dislocation line tension model to improve understanding of the effects of hydrogen on the deformation of structural materials

Decarbonization efforts highlight hydrogen as an attractive alternative to fossil fuels, but its tendency to embrittle structural metals demands careful consideration when designing hydrogen infrastructure. Moreover, the mechanisms by which hydrogen degrades these materials are still being elucidated. The current work develops new computational tools to quantify the different contributions of hydrogen to the energy barrier of cross-slip, a key deformation mechanism. Novel features are implemented to a line tension model, which include the use of non-singular dislocation interactions, character-dependent dislocation energies and simulations of the constriction configurations. A new molecular dynamics technique is developed to calculate the interaction energy between the partials of a dissociated dislocation via fixing the centers of mass of the regions below and above the Shockley partials and performing time-averaged calculations. Hydrogen is found to impact the stacking fault width of dislocations in different ways depending on their characters: it decreases for dislocations with a character θ > 30°, remains unchanged for θ = 30° and increases for θ < 30°. The latter regime is a newly identified mechanism by which hydrogen inhibits cross-slip. Moreover, formation of nano-hydrides is predicted to occur around screw dislocations for high hydrogen concentrations, a phenomenon previously identified only in dislocations with an edge component. If nano-hydrides develop, their influence extending the equilibrium stacking fault width and increasing both the constriction and cross-slip energy barriers dominate over all other hydrogen contributions. The theory and tools developed will pave the way towards a comprehensive understanding of hydrogen-dislocation interactions in structural metals.

08 HYDROGEN↗

Modeling Contact Angle vs. Temperature for the Quartz-Water-Decane System

Innovative approaches are needed to improve the efficiency of oil recovery technologies to meet the growing demands of fossil-fuel based energy consumption. Enhanced oil recovery (EOR) methods such as low-salinity waterflooding and chemically tuned waterflooding aim to optimize the reservoir’s wetting properties, detaching oil globules from rock surfaces and allowing easier oil flow through pore throats. This wetting behavior is commonly quantified by contact angle measurements of the rock-oil-brine interface, which have been thoroughly investigated and theorized for many systems at ambient temperatures and pressures. However, few studies exist for extending contact angle theories away from ambient conditions. In this paper, we model the contact angles of a quartz-water-decane system at elevated temperatures using the surface tension component (STC) approach. Temperature-dependent van der Waals [Lifshitz-van der Waals (LW)] interactions and hydrogen-bonding (acid-base) interactions were calculated and are incorporated into the model for the quartz-water-decane interface. Additionally, the Hough and White procedure was used to create temperature-dependent dielectric functions of quartz, water, and normal decane for calculations of Hamaker coefficients. Hamaker coefficients calculated this way are highly linear with temperature and agree well with Israelachvili’s approximation. The acid-base interactions likely contribute the most to system wettability changes. Resulting contact angles of the quartz-water-decane system shift from water-wet (16°) to slightly water-wet (57.4°) as temperature increases. The model was also successfully verified for the quartz-air-water system. Our results can be used in future studies to determine optimal injected water compositions for specific rock-oil-brine and other systems with consideration of reservoir temperature.

02 PETROLEUM↗

Temporal complementarity of marine renewables with wind and solar generation: Implications for GB system benefits

Wave and tidal energy have the potential to provide benefits to power systems with high proportions of stochastic renewable generation. This is particularly applicable with wind and solar photovoltaics, as the offsetting of these renewable resources results in more reliable renewable generation. This study utilises ten metrics to quantify the temporal complementarity and supply-demand balancing requirements of the energy mix in Great Britain, to investigate the potential magnitude of these system benefits. Wave and tidal generation profiles are created using historical resource data and hydrodynamic models. The results show that the inclusion of wave and tidal generation creates a renewable energy mix which is more available under multiple conditions: throughout a year of operation; at times of peak demand; for multiple consecutive hourly time periods; and at times when wind and solar generation are not available. Three regional case studies also show that the inclusion of marine energy allows for improved regional supply-demand matching, reducing instances of energy shortage and excess and potentially relieving transmission congestion at particularly constrained locations within GB. Finally, the implications of these findings are discussed in terms of GB wholesale market operation, system balancing and system security.

16 TIDAL AND WAVE POWER↗

Comparison of temporal resolution selection approaches in energy systems models

Capacity expansion models for the power sector are used to project future decisions over the coming decades by simulating investment and operation decisions for the use of electricity. Due to model performance constraints, these models typically do not explicitly simulate every hour within a year, but instead simulate representative time segments (groups of hours). This paper evaluates different approaches for selecting time segments across three methods: sequential, categorical, and clustering, across a wide range of time-segment quantities, for a total of 204 temporal profiles. To measure the performance of each profile's ability to accurately represent data, the root-mean-square-error of each profile's time segments are compared to the data's original hourly data. The temporal alignment across regions is also measured (i.e., how often windy days align across regions). Different spatial resolutions were applied for a subset of the temporal selection methods to investigate the impact spatial resolution has on performance. This paper provides a framework for measuring the value of different temporal selection methods and of adding more granular data to energy system models. Overall, multi-criteria clustering yields the lowest root-mean-square-error across all datasets evaluated and provides a holistic view of the intertwined relationships between renewable generation and electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

Understanding the Charging Flexibility of Shared Automated Electric Vehicle Fleets

The combined anticipated trends of vehicle sharing (ride-hailing), automated control, and powertrain electrification are poised to disrupt the current paradigm of predominately owner-driven gasoline vehicles with low levels of utilization. Shared, automated, electric vehicle (SAEV) fleets offer the potential for lower cost and emissions and have garnered significant interest among the research community. While promising, unmanaged operation of these fleets may lead to unintended negative consequences. One potentially unintended consequence is a high quantity of SAEVs charging during peak demand hours on the electric grid, potentially increasing the required generation capacity. This research explores the flexibility associated with charging loads demanded by SAEV fleets in response to servicing personal mobility travel demands. Travel demand is synthesized in four major United States metropolitan areas: Detroit, MI; Austin, TX; Washington, DC; and Miami, FL. In each of these four cities, SAEV simulations are performed using local projected electricity prices from the Regional Energy Deployment System (ReEDS) for a handful of supply side scenarios. A coordinated charging model is introduced that seeks to reduce fleet charging costs in response to time-varying electricity prices and increasing shares of personal trip demand served (between 1% and 25% of all metro trips served by the SAEV fleet). Simulation results are presented across various scenarios assuming fleetwide coordination to minimize charging energy costs while constrained by offering adequate mobility service to fleet customers. The results indicate that the SAEV charging load is highly flexible; energy costs were shown to reduce between 13% and 46% across a wide range of simulated scenarios. In addition, these savings were realized without detrimentally impacting the fleet’s ability to service trips.

autonomous vehicle↗

ComStock Measure Documentation: Lighting Control for Load Shedding

This report describes the modeling methodology for a single end-use savings shape measure - lighting control for load shedding - and briefly introduces key results. The lighting control for load shedding measure applies lighting dimming control to reduce the lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then adjusts the lighting dimming level by a percentage reduction from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 2%-7% daily peak demand reduction performance for applicable buildings, and 0.43% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗