Techniques for containing error propagation in compression/decompression schemes

Data compression has the potential for increasing the risk of data loss. It can also cause bit error propagation, resulting in catastrophic failures. There are a number of approaches possible for containing error propagation due to data compression: (1) data retransmission; (2) data interpolation; (3) error containment; and (4) error correction. The most fruitful techniques will be ones where error containment and error correction are integrated with data compression to provide optimal performance for both. The error containment characteristics of existing compression schemes should be analyzed for their behavior under different data and error conditions. The error tolerance requirements of different data sets need to be understood, so guidelines can then be developed for matching error requirements to suitable compression algorithms.

Kobler, Ben↗

The maturing of the quality improvement paradigm in the SEL

The Software Engineering Laboratory uses a paradigm for improving the software process and product, called the quality improvement paradigm. This paradigm has evolved over the past 18 years, along with our software development processes and product. Since 1976, when we first began the SEL, we have learned a great deal about improving the software process and product, making a great many mistakes along the way. Quality improvement paradigm, as it is currently defined, can be broken up into six steps: characterize the current project and its environment with respect to the appropriate models and metrics; set the quantifiable goals for successful project performance and improvement; choose the appropriate process model and supporting methods and tools for this project; execute the processes, construct the products, and collect, validate, and analyze the data to provide real-time feedback for corrective action; analyze the data to evaluate the current practices, determine problems, record findings, and make recommendations for future project improvements; and package the experience gained in the form of updated and refined models and other forms of structured knowledge gained from this and prior projects and save it in an experience base to be reused on future projects.

Basili, Victor R.↗

Testing Different Methods for Estimating Uncertainties on Rietveld Refined Parameters Using SrRietveld

The advent of fast computing allows more computationally expensive, though possibly more accurate, approaches for estimating uncertainties on Rietveld refined parameters. Here we compare three such methods, using two different refinement programs, FullProf and GSAS. This is facilitated by the use of a new Rietveld refinement package, SrRietveld, that provides Python wrappers for FullProf and GSAS. The refined values on the parameters from two different refinement engines match each other very well. The uncertainty estimates determined using the different methods are also consistent, though FullProf and GSAS estimate the parameter uncertainties slightly differently from each other, which is discussed. More importantly, we find that the refined results are very sensitive to the statistical weights used in the least squares equation. Different weights, for example from uncertain or incorrectly propagated random errors on the data, lead to significantly different refined values. This means that uncertainty estimates on refined parameters should be increased when the random errors on the data are not well known, as for example in many cases where area detectors are used, and care should be taken to propagate errors correctly in any data preprocessing such as normalization by a smoothed spectrum. The computationally expensive bootstrap error estimation methods are facilitated by the use of SrRietveld, but are not required in most cases though may be useful in some cases, for example if the random errors on the data are not well known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MEASURING CLAS12 D(E, E′Π±) CROSS SECTIONS FOR E4NU

Neutrino experiments need neutrino event generators such as GENIE to simulate neutrinonucleus (¿A) interactions in order to measure neutrino oscillations. We need eA data to validate GENIE. GENIE d(e, e') cross sections do not match data in the pion production region. Further analysis of this region can help constrain GENIE models. The goal of this project was to compare 4.244 GeV CLAS12 d(e, e'p±) cross sections to GENIE predictions. We analyzed data from the Fall 2019 run period of Run Group B (RG-B). We applied particle identification, fiducial, and vertex cuts on electron and charged pion candidates. We compared the measured data with events generated with GENIE and another generator called onepigen. We used onepigen to simulate single charged pion production and to calculate radiative corrections for the data. We submitted GENIE and onepigen events to the GEant4 Monte-Carlo (GEMC) simulation of CLAS12 and applied the same cuts we used on the data. We plotted cross sections as functions of W and binned the events in Q2, ¿pq, and Pp. We used 2D (Q2), 3D (Q2 with ¿pq or Pp), and 4D (Q2, ¿pq, and Pp) binning schemes. We found GENIE describes d(e, e'p±) cross sections better than expected. GENIE describes the data remarkably well in the 2D bins and some 3D and 4D bins. There are many discrepancies between GENIE and data in the other 3D and 4D bins. The results show that, relative to data, GENIE cross sections increase as Q2 increases, decrease as Pp increases, and fit best at low ¿pq. These results will help guide improvements to GENIE in order to reduce the systematic uncertainties in neutrino-oscillation experiments.

Fogler, Caleb [Old Dominion Univ., Norfolk, VA (Un↗

Local respiratory motion correction for PET/CT imaging: Application to lung cancer

Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom) and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid deformation model in LRMC led to over an order of magnitude gain in computational efficiency of the correction relative to the application of the deformable model to the whole FOV. Conclusions: The results of this study support the use of LMRC as a flexible and efficient correction approach for respiratory motion effects for single lesions in the thoracic area.

60 APPLIED LIFE SCIENCES↗

Assessments of S-NPP and N20 VIIRS DNB and M bands calibration stability and consistency using a homogeneous ground target

The S-NPP and N20 VIIRS Day-Night band (DNB) and M bands top-of-atmosphere (TOA) radiance and reflectance are calculated and a kernel-driven Bidirectional Reflectance Distribution Function (BRDF) correction model is used to correct the surface and atmosphere combined BRDF influence. Due to degradation in the DNB modulated Relative Spectral Response (RSR), the S-NPP VIIRS observed TOA DNB reflectance indicates a decrease of 1.89% and the SCIAMACHY spectra derived TOA DNB reflectance has a decrease of 1.63% for the past 8.5 years. The N20 VIIRSTOA DNB reflectance decreased 0.50% in the past 2.5 years. The DNB radiance is also compared with the integral of the M bands radiance from M4, M5, and M7. The fitting trends of DNB to the integral of M bands ratios indicate a0.48% decrease for S-NPP VIIRS and 0.14% increase for N20 VIIRS. The N20 VIIRS DNB to integral M bands ratios are closer to 1 than the S-NPP VIIRS data. The BRDF corrected reflectance comparisons show that the N20 VIIRS data is slightly lower than those of S-NPP VIIRS. The averages of the linear fit values of the N20 to S-NPP VIIRS from 2018to 2020 June are -1.97%, -4.99%, -3.36%, and -0.85% for M4, M5, M7, and DNB, respectively. Our results indicate that the S-NPP and N20 VIIRS DNB and M bands calibration have been stable. The cross-sensor differences in DNB and M bands are generally consistent with other independent studies using similar and different approaches.

Libya 4↗

Bias corrections of GOSAT SWIR XCO 2 and XCH 4 with TCCON data and their evaluation using aircraft measurement data

We describe a method for removing systematic biases of column-averaged dry air mole fractions of CO 2 (XCO 2 ) and CH 4 (XCH 4 ) derived from short-wavelength infrared (SWIR) spectra of the Greenhouse gases Observing SATellite (GOSAT). We conduct correlation analyses between the GOSAT biases and simultaneously retrieved auxiliary parameters. We use these correlations to bias correct the GOSAT data, removing these spurious correlations. Data from the Total Carbon Column Observing Network (TCCON) were used as reference values for this regression analysis. To evaluate the effectiveness of this correction method, the uncorrected/corrected GOSAT data were compared to independent XCO 2 and XCH 4 data derived from aircraft measurements taken for the Comprehensive Observation Network for TRace gases by AIrLiner (CONTRAIL) project, the National Oceanic and Atmospheric Administration (NOAA), the US Department of Energy (DOE), the National Institute for Environmental Studies (NIES), the Japan Meteorological Agency (JMA), the HIAPER Pole-to-Pole observations (HIPPO) program, and the GOSAT validation aircraft observation campaign over Japan. These comparisons demonstrate that the empirically derived bias correction improves the agreement between GOSAT XCO 2 /XCH 4 and the aircraft data. Finally, we present spatial distributions and temporal variations of the derived GOSAT biases.

54 ENVIRONMENTAL SCIENCES↗

Snow Crystal Shape and Microwave Scattering

The radiometric calibration of SeaWiFS data includes a correction for the temperature dependence of the individual detector sensitivities. The detector temperature are measured by temperature sensors mounted on instrument focal planes. Processing of the temperature sensor output by an onboard instrument computer introduces a nonlinear response into the temperature data. This paper describes the calibration of the temperature sensor output and the computation of the temperature corrections for the radiometric calibration of the instrument.

Foster, J. L.↗

Dual energy CT: How well can pseudo-monochromatic imaging reduce metal artifacts?

Purpose: Dual Energy CT (DECT) provides so-called monoenergetic images based on a linear combination of the original polychromatic images. At certain patient-specific energy levels, corresponding to certain patient- and slice-dependent linear combination weights, e.g., E = 160 keV corresponds to α = 1.57, a significant reduction of metal artifacts may be observed. The authors aimed at analyzing the method for its artifact reduction capabilities to identify its limitations. The results are compared with raw data-based processing. Methods: Clinical DECT uses a simplified version of monochromatic imaging by linearly combining the low and the high kV images and by assigning an energy to that linear combination. Those pseudo-monochromatic images can be used by radiologists to obtain images with reduced metal artifacts. The authors analyzed the underlying physics and carried out a series expansion of the polychromatic attenuation equations. The resulting nonlinear terms are responsible for the artifacts, but they are not linearly related between the low and the high kV scan: A linear combination of both images cannot eliminate the nonlinearities, it can only reduce their impact. Scattered radiation yields additional noncanceling nonlinearities. This method is compared to raw data-based artifact correction methods. To quantify the artifact reduction potential of pseudo-monochromatic images, they simulated the FORBILD abdomen phantom with metal implants, and they assessed patient data sets of a clinical dual source CT system (100, 140 kV Sn) containing artifacts induced by a highly concentrated contrast agent bolus and by metal. In each case, they manually selected an optimal α and compared it to a raw data-based material decomposition in case of simulation, to raw data-based material decomposition of inconsistent rays in case of the patient data set containing contrast agent, and to the frequency split normalized metal artifact reduction in case of the metal implant. For each case, the contrast-to-noise ratio (CNR) was assessed. Results: In the simulation, the pseudo-monochromatic images yielded acceptable artifact reduction results. However, the CNR in the artifact-reduced images was more than 60% lower than in the original polychromatic images. In contrast, the raw data-based material decomposition did not significantly reduce the CNR in the virtual monochromatic images. Regarding the patient data with beam hardening artifacts and with metal artifacts from small implants the pseudo-monochromatic method was able to reduce the artifacts, again with the downside of a significant CNR reduction. More intense metal artifacts, e.g., as those caused by an artificial hip joint, could not be suppressed. Conclusions: Pseudo-monochromatic imaging is able to reduce beam hardening, scatter, and metal artifacts in some cases but it cannot remove them. In all cases, the CNR is significantly reduced, thereby rendering the method questionable, unless special post processing algorithms are implemented to restore the high CNR from the original images (e.g., by using a frequency split technique). Raw data-based dual energy decomposition methods should be preferred, in particular, because the CNR penalty is almost negligible.

60 APPLIED LIFE SCIENCES↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

Earth Observing-1 Advanced Land Imager Flight Performance Assessment: Absolute Radiometry and Stability During the First Year

The absolute radiometry of the Advanced Land Imager during the first year on orbit (November 21,2000 - November 21, 2001) is presented. Results derived from solar, lunar, ground truth, and internal reference lamp measurements are presented. An 18% drop in the radiometric response of the Band 1p data since preflight calibration at Lincoln Laboratory is observed using all techniques. This decrease cannot be accounted for by preflight calibration errors, stray light, or contamination of the focal plane. A slight drooping of the VNIR response toward the blue and a 5-12% increase in the Band 5 response is also apparent in all the data. Radiometric response correction factors have been calculated and preflight calibration coefficients have been updated in order to provide +/- 5% agreement between the measured solar, lunar, and ground truth data and the expected values. The radiometric stability of the ALI during the first year of operation is also presented for each spectral band. Internal reference lamp data indicate the focal plane has been stable to within 1% for bands 1p, 1, 2, 5p, 5, 7, pan and 3% for Bands 3,4, 4p since launch. Solar, lunar, and ground truth measurements indicate the optical train and solar diffuser of the instrument has been stable to within 1% since initial measurements on orbit in late December 2000.

Mendenhall, J. A.↗

Using the Saturn V and Titan III Vibroacoustic Databanks for Random Vibration Criteria Development

This is an update to TN D-7159, "Development and Application of Vibroacoustic Structural Data Banks in Predicting Vibration Design and Test Criteria for Rocket Vehicle Structures", which was originally published in 1973. Errors in the original document have been corrected and additional data from the Titan III program have been included. Methods for using the vibroacoustic databanks for vibration test criteria development are shown, as well as all of the data with drawings and pictures of the measurement locations. An Excel spreadsheet with the data included is available from the author.

Ferbee, R C.↗

Advancements in the Aerosol Robotic Network (AERONET) Version 3 database – automated near-real-time quality control algorithm with improved cloud screening for Sun photometer aerosol optical depth (AOD) measurements

The Aerosol Robotic Network (AERONET) has provided highly accurate, ground-truth measurements of the aerosol optical depth (AOD) using Cimel Electronique Sun–sky radiometers for more than 25 years. In Version 2 (V2) of the AERONET database, the near-real-time AOD was semiautomatically quality controlled utilizing mainly cloud-screening methodology, while additional AOD data contaminated by clouds or affected by instrument anomalies were removed manually before attaining quality-assured status (Level 2.0). The large growth in the number of AERONET sites over the past 25 years resulted in significant burden to the manual quality control of millions of measurements in a consistent manner. The AERONET Version 3 (V3) algorithm provides fully automatic cloud screening and instrument anomaly quality controls. All of these new algorithm updates apply to near-real-time data as well as post-field-deployment processed data, and AERONET reprocessed the database in 2018. A full algorithm redevelopment provided the opportunity to improve data inputs and corrections such as unique filter-specific temperature characterizations for all visible and near-infrared wavelengths, updated gaseous and water vapor absorption coefficients, and ancillary data sets. The Level 2.0 AOD quality-assured data set is now available within a month after post-field calibration, reducing the lag time from up to several months. Near-real-time estimated uncertainty is determined using data qualified as V3 Level 2.0 AOD and considering the difference between the AOD computed with the pre-field calibration and AOD computed with pre-field and post-field calibration. This assessment provides a near-real-time uncertainty estimate for which average differences of AOD suggest a +0.02 bias and one sigma uncertainty of 0.02, spectrally, but the bias and uncertainty can be significantly larger for specific instrument deployments. Long-term monthly averages analyzed for the entire V3 and V2 databases produced average differences (V3–V2) of +0.002 with a ±0.02 SD (standard deviation), yet monthly averages calculated using time-matched observations in both databases were analyzed to compute an average difference of −0.002 with a ±0.004 SD. The high statistical agreement in multiyear monthly averaged AOD validates the advanced automatic data quality control algorithms and suggests that migrating research to the V3 database will corroborate most V2 research conclusions and likely lead to more accurate results in some cases.

David M. Giles↗

EPCAPE-PT-LANL Measurements: Photoacoustic Extinctometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Photoacoustic Extinctiometer at 870 nm (Droplet Measurement Technology) Header: - AbsorptionNoise_870nm[1/Mm]: Noise level associated with the absorption measurement at 870 nm, expressed in inverse megameters (Mm⁻¹). - Absorption_870nm[1/Mm]: Absorption coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - Extinction_870nm[1/Mm]: Extinction coefficient of aerosols measured at 870 nm, expressing the sum of scattering and absorption by aerosols, in inverse megameters (Mm⁻¹). - Scattering_870nm[1/Mm]: Scattering coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - BackgroundAbsorption_870nm[1/Mm]: Background absorption measurement at 870 nm, used to correct the primary absorption data, expressed in inverse megameters (Mm⁻¹). - BackgroundScattering_870nm[1/Mm]: Background scattering measurement at 870 nm, used to correct the primary scattering data, expressed in inverse megameters (Mm⁻¹). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗

Casual Rerouting of AERONET Sun/Sky Photometers: Toward a New Network of Ground Measurements Dedicated to the Monitoring of Surface Properties?

This paper presents an innovative method for observing vegetation health at a very high spatial resolution (~5 × 5 cm) and low cost by upgrading an existing Aerosol RObotic NETwork (AERONET) ground station dedicated to the observation of aerosols in the atmosphere. This study evaluates the capability of a sun/sky photometer to perform additional surface reflectance observations. The ground station of Toulouse, France, which belongs to the AERONET sun/sky photometer network, is used for this feasibility study. The experiment was conducted for a 5-year period (between 2016 and 2020). The sun/sky photometer was mounted on a metallic structure at a height of 2.5 m, and the acquisition software was adapted to add a periodical (every hour) ground-observation scenario with the sun/sky photometer observing the surface instead of being inactive. Evaluation is performed by using a classical metric characterizing the vegetation health: the normalized difference vegetation index (NDVI), using as reference the satellite NDVI derived from a Sentinel-2 (S2) sensor at 10 × 10 m resolution. Comparison for the 5-year period showed good agreement between the S2 and sun/sky photometer NDVIs (i.e., bias = 0.004, RMSD = 0.082, and R = 0.882 for a mean value of S2A NDVI around 0.6). Discrepancies could have been due to spatial-representativeness issues (of the ground measurement compared to S2), the differences between spectral bands, and the quality of the atmospheric correction applied on S2 data (accuracy of the sun/sky photometer instrument was better than 0.1%). However, the accuracy of the atmospheric correction applied on S2 data in this station appeared to be of good quality, and no dependence on the presence of aerosols was observed. This first analysis of the potential of the CIMEL CE318 sun/sky photometer to monitor the surface is encouraging. Further analyses need to be carried out to estimate the potential in different AERONET stations. The occasional rerouting of AERONET stations could lead to a complementary network of surface reflectance observations. This would require an update of the software, and eventual adaptations of the measurement platforms to the station environments. The additional cost, based on the existing AERONET network, would be quite limited. These new surface measurements would be interesting for measurements of vegetation health (monitoring of NDVI, and also of other vegetation indices such as the leaf area and chlorophyll indices), for validation and calibration exercise purposes, and possibly to refine various scientific algorithms (i.e., algorithms dedicated to cloud detection or the AERONET aerosol retrieval algorithm itself). CIMEL is ready to include the ground scenario used in this study in all new sun/sky photometers.

Dominique Carrer↗

Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland–Altman analyses revealed proportional bias between prone and supine measurements (SUV{sub peak} and SUV{sub max}) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUV{sub peak} difference (P = 0.78). Conclusions: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.

60 APPLIED LIFE SCIENCES↗

Physics validation studies for muon collider detector background simulations

Within the broad discipline of physics, the study of the fundamental forces of nature and the most basic constituents of the universe belongs to the field of particle physics. While frequently referred to as 'high-energy physics,' or by the acronym 'HEP,' particle physics is not driven just by the quest for ever-greater energies in particle accelerators. Rather, particle physics is seen as having three distinct areas of focus: the cosmic, intensity, and energy frontiers. These three frontiers all provide different, but complementary, views of the basic building blocks of the universe. Currently, the energy frontier is the realm of hadron colliders like the Tevatron at Fermi National Accelerator Laboratory (Fermilab) or the Large Hadron Collider (LHC) at CERN. While the LHC is expected to be adequate for explorations up to 14 TeV for the next decade, the long development lead time for modern colliders necessitates research and development efforts in the present for the next generation of colliders. This paper focuses on one such next-generation machine: a muon collider. Specifically, this paper focuses on Monte Carlo simulations of beam-induced backgrounds vis-a-vis detector region contamination. Initial validation studies of a few muon collider physics background processes using G4beamline have been undertaken and results presented. While these investigations have revealed a number of hurdles to getting G4beamline up to the level of more established simulation suites, such as MARS, the close communication between us, as users, and the G4beamline developer, Tom Roberts, has allowed for rapid implementation of user-desired features. The main example of user-desired feature implementation, as it applies to this project, is Bethe-Heitler muon production. Regarding the neutron interaction issues, we continue to study the specifics of how GEANT4 implements nuclear interactions. The GEANT4 collaboration has been contacted regarding the minor discrepancies in the neutron interaction cross sections for boron. While corrections to the data files themselves are simple to implement and distribute, it is quite possible, however, that coding changes may be required in G4beamline or even in GEANT4 to fully correct nuclear interactions. Regardless, these studies are ongoing and future results will be reflected in updated releases of G4beamline.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new technique for monitoring the water vapor in the atmosphere

In the correction of satellite Doppler data for tropospheric effects the precipitable water vapor (PWV) is inferred at the tracking site. The technique depends on: (1) an ephemeris for the satellite; (2) an analytic model for the refraction range effect that is good to a few centimeters; (3) Doppler data with noise level below 10 centimeters; and (4) a surface pressure/temperature measurement at the tracking site. The PWV is a by product of the computation necessary to correct the Doppler data for tropospheric effects. A formulation of the refraction integral minimizes the necessity for explicit water vapor, temperature and pressure profiles.

Black, H. D.↗