Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An FEM-Based Peridynamic Model for Failure Analysis of Unidirectional Fiber-Reinforced Laminates

To predict the mixed damage modes of unidirectional fiber-reinforced polymer (FRP) laminates under dynamic loading, an FEM-based peridynamic model is introduced in this paper. Based on its geometric structure and material composition, a long fiber lamina is considered a transversely isotropic medium as a result of homogenization at the meso-scale. The laminated structure is modeled by stacking surface mesh layers with arbitrary fiber angles along the thickness direction. The peridynamic bonds between Gauss points connect the separated elements. These bonds are classified as inner-layer bonds and inter-layer bonds. To represent the anisotropy of a laminate, the micro-elastic modulus of the inner-layer and inter-layer bonds is calculated from the anisotropic engineering material constants separately. To capture complex failure behaviors of laminate structures, an empirical damage model is proposed for the tension/ compression breakage of peridynamic bonds. This damage model can control the in-plane and delamination failure process. Finally, benchmark tests are conducted to validate the elastic response of laminates under dynamic loading. In terms of damage analysis, the proposed model can capture the complex damage modes and resistive force of laminate structures.

36 MATERIALS SCIENCE↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and characterization of dextran/zein hybrid electrospun fibers with tailored properties for controlled release of curcumin

Abstract BACKGROUND In recent years, there has been considerable interest in the use of biopolymer electrospun nanofibers for various food applications due to the biocompatibility, biodegradability, and high loading capacity. Herein, we fabricated and characterized novel hybrid electrospun fibers from dextran (50%, w/v ) and zein (0–30%, w/v ) solutions, and the effects of various zein concentrations on the properties of the hybrid electrospun fibers were investigated. RESULTS When zein was added at low concentrations (5% and 10%), dextran and zein showed poor miscibility, as reflected by significantly decreased viscosity of the solutions, and the poor mechanical properties of the derived fiber membranes. When zein was added at medium concentrations (15–25%), hydrogen bonds were formed between dextran and zein molecules, as indicated by the red shift of Fourier‐transform infrared bands and β‐sheet to α‐helix structural transformations. The fiber membranes electrospun from a solution with 25% zein showed the most hydrophobic surface, with a water contact angle of 116.9°. The homogenous dispersion of dextran and zein resulted in improved mechanical properties for fibers electrospun from a solution with 30% zein. Curcumin encapsulating dextran/zein electrospun fibers exhibited effective radical scavenging activity and ferric reducing power, along with the desired controlled release behavior for curcumin delivery. CONCLUSION Food grade dextran/zein hybrid electrospun fibers demonstrated tunable properties, and appear to be promising as delivery systems for bioactive and edible antimicrobial food packaging. © 2021 Society of Chemical Industry.

Luo, Shiyuan↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pt Particles on a Dynamic TiO 2 Support in Near-Ambient Conditions−Disentangling Size, Pressure, and Support Effects

Platinum particles on reducible oxides are known to form complex and highly dynamic catalyst systems at elevated pressures and temperatures, often adopting active structures that differ from those found at room temperature and under ultrahigh vacuum (UHV). Here, we study the oxidation and structural evolution of subnanometer Pt clusters and nanoparticles supported on rutile TiO 2 (110) across an oxygen pressure range from UHV to 0.1 mbar, using near-ambient pressure X-ray photoelectron spectroscopy (NAP-XPS), scanning tunneling microscopy (STM) under UHV and NAP conditions, and low-energy ion scattering (LEIS). Our results reveal distinct differences in oxidation behavior and thermal stability between Pt nanoparticles and clusters, which are further modulated by the support stoichiometry and oxygen pressure. Small Pt clusters become oxidized even at room temperature but are susceptible to accelerated sintering in 0.1 mbar O 2 at elevated temperatures. In contrast, well-crystallized Pt nanoparticles on near-stoichiometric TiO 2 show weaker oxidation. On a reduced, defective TiO 2 support, Pt instead quickly becomes deeply buried by new titania layers, which are formed during support reoxidation. This process appears to result primarily from interactions of the support with the gas phase, unlike the classical, selflimited encapsulation that is induced by the strong metal−support interaction (SMSI). Finally, we address the full complexity of real catalysts in a direct side-by-side comparison of the single-crystalline model system with a Pt-loaded TiO 2 powder catalyst (P25). We conclude that the stoichiometry of the model supports must be carefully chosen and controlled to accurately reproduce the expected state of powder supports during redox reactions.

metal nanoparticles↗

Impact of wake steering on loads of downstream wind turbines at an above-rated condition

Wake steering strategies often seek to gain power at the expense of increased fatigue loads. Here, we investigate the feasibility of applying wake steering at an above-rated condition. In such a condition, the farm is operating at rated power, and thus, increased power output is not the goal. Instead, wake steering is considered in the context of load reduction. We perform a sweep of wind directions and yaw misalignment angles, ranging from negative to positive values. This approach allows us to obtain trends and identify asymmetries in turbine response for symmetric scenarios. We use a wind farm consisting of five aligned IEA Wind 15-MW reference wind turbines, and analyze trends related to the blade-root, low-speed shaft, and tower-base moments, both in terms of standard deviation and damage equivalent loads. We show that for any given fixed wind direction, the turbines can be yawed such that the fatigue loads are reduced. Reductions of up to 5% (depending on the component) in terms of standard deviation and damage equivalent loads can be achieved by negatively yawing the turbine. A negative yaw misalignment has shown to be the direction of larger improvements. Such results contrast those found for below-rated conditions, where a positive yaw misalignment is typically preferred. However, since load reduction is not uniform across all component loads, more study and consideration is required before operational recommendations can be made.

17 WIND ENERGY↗

Biomechanical Analysis of Multilevel Posterior Cervical Spinal Fusion Constructs

Study Design: Controlled Laboratory Study Objective: To compare multilevel posterior cervical fusion (PCF) constructs stopping at C7, T1, and T2 under cyclic load to determine the range of motion (ROM) between the lowest instrumented level and lowest instrumented-adjacent level (LIV-1). Summary of Background Data: PCF is a mainstay of treatment for various cervical spine conditions. The transition between the flexible cervical spine and rigid thoracic spine can lead to construct failure at the cervicothoracic junction. There is little evidence to determine the most appropriate level at which to stop a multilevel PCF. Methods: Fifteen human cadaveric cervicothoracic spines were randomly assigned to 1 of 3 treatment groups: PCF stopping at C7, T1, or T2. Specimens were tested in their native state, following a simulated PCF, and after cyclic loading. Specimens were loaded in flexion-extension), lateral bending, and axial rotation. Three-dimensional kinematics were recorded to evaluate ROM. Results: The C7 group had greater flexion-extension motion than the T1 and T2 groups following instrumentation (10.17±0.83 degree vs. 2.77±1.66 degree and 1.06±0.55 degree, P <0.001), and after cyclic loading (10.42±2.30 degree vs. 2.47±0.64 degree and 1.99±1.23 degree, P <0.001). There was no significant difference between the T1 and T2 groups. The C7 group had greater lateral bending ROM than both thoracic groups after instrumentation (8.81±3.44 degree vs. 3.51±2.52 degree, P =0.013 and 1.99±1.99 degree, P =0.003) and after cyclic loading. The C7 group had greater axial rotation motion than the thoracic groups (4.46±2.27 degree vs. 1.26±0.69 degree, P =0.010; and 0.73±0.74 degree, P =0.003) following cyclic loading. Conclusion: Motion at the cervicothoracic junction is significantly greater when a multilevel PCF stops at C7 rather than T1 or T2. This is likely attributable to the transition from a flexible cervical spine to a rigid thoracic spine. Although this does not account for in vivo fusion, surgeons should consider extending multilevel PCF constructs to T1 when feasible. Level of Evidence: Not applicable.

Neurosciences & Neurology↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Caldera_Grid

Caldera Grid is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. Caldera Grid is a co-simulation framework implemented using Hierarchical Engine for Large scale Infrastructure Co-Simulation (HELICS). The framework facilitates the co-simulation of EV charging and Smart Charge Management (SCM) strategies in Caldera Infrastructure Charge Model (ICM) with distribution level grid models in OpenDSS. Vehicle energy needs and charge session requirements generated using Caldera Charge Decision Module (CDM) are fed in as input to Caldera Grid. The EV charging models in Caldera ICM simulates both the uncontrolled charging loads as well as loads modified by the SCM strategies to develop distributed load profiles for each grid node hosting an Electric Vehicle Supply Equipment (EVSE) – also known as chargers. These loads were simulated in OpenDSS alongside existing distribution feeder loads. Each of these models are co-simulated in a HELICS federate. The HELICS co-simulation framework facilitates communication and synchronization between the federates. By co-simulating EV loads and distribution feeder loads, Caldera Grid can assess the potential grid impacts of EV charging on distribution feeders under various grid conditions. A control strategy federate is implemented with an interface where control strategies based on feedback from EV charging status and grid conditions can be developed and implemented. The platform can also support multiple control strategies in a single co-simulation.

Sundarrajan, ManojKumar Cebol↗

Extreme Miller cycle with high intake boost for improved efficiency and emissions in heavy-duty diesel engines

This study experimentally investigates the impact of extreme Miller cycle strategies paired with high intake manifold pressures on the combustion process, emissions, and thermal efficiency of heavy-duty diesel engines. Well-controlled experiments isolating the effect of Miller cycle strategies on the combustion process were conducted at constant engine speed and load (1160 rpm, 1.76 MPa net IMEP) on a single cylinder research engine equipped with a fully-flexible hydraulic valve train system. Late intake valve closing (LIVC) timing strategies were compared to a conventional intake valve profile under either constant cylinder composition, constant engine-out NO x emission, or constant overall turbocharger efficiency (η TC ) to investigate the operating constraints that favor Miller cycle operation over the baseline strategy. Furthermore, utilizing high boost with conventional intake valve closing timing resulted in improved fuel consumption at the expense of sharp increases in peak cylinder pressures, engine-out NO x emissions, and reduced exhaust temperatures. Miller cycle without EGR at constant λ demonstrated LIVC strategies effectively reduce engine-out NO x emissions by up to 35%. However, Miller cycle associated with very aggressive LIVC timings led to fuel consumption penalties due to increased pumping work and exhaust enthalpy. LIVC strategies allowed for increased charge dilution at the baseline NO x constraint of 3.2 g/kWh, resulting in significant fuel consumption benefits over the baseline case without compromising exhaust temperatures or peak cylinder pressures. As Miller cycle implementation was shown to affect the boundary conditions dictating η TC , the LIVC and conventional IVC cases were studied at an equivalent η TC point representative of high boost operation. With high boost, LIVC yielded reduced NO x emissions, reduced peak cylinder pressures, and elevated exhaust temperatures compared to the conventional IVC case without compromising fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance sensitivity to radial power flattening considerations in Nuclear Thermal Propulsion Reactors

Nuclear thermal propulsion is currently being developed for manned Mars and Lunar missions by the National Aeronautics and Space Administration due to its increased specific impulse and significant thrust to reduce the total trip time and cost of deep space missions. To maximize the performance of the engine the exit hydrogen propellant temperature should, ideally, be uniformly distributed among all the fuel elements. Uniform exit temperatures imply that the power must be flattened as much as possible. This paper leverages decoupled neutronic and thermal-hydraulic models to assess the thermal performance and reactivity tradeoffs associated with flattening the radial power distribution by adjusting the fuel kernel loading for each fuel element within the core. The results suggest that a uniform radial power distribution for a single control drum position will not necessarily yield an optimal core design due to the higher variance in power and thus maximum fuel and exit propellant temperature as the control drums rotate out during operation. The results presented here only point to the design characteristics be considered when core-level multi-physics simulations are applied in the context of a specific mission. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

Dynamic Simulation of a Sub-Critical Coal Fired Power Plant

In order to address the demanding operating conditions for remaining coal-fired power plants, a dynamic model and a suite of tools have been developed for studying load cycling and to find optimization opportunities. A sub-critical steam cycle power plant was modeled in a flow-sheet modeling tool, APROS™. The model represented the firing system, economizer, evaporator, superheat, and reheat systems. Four loads from 100% TMCR to 25% TMCR were calibrated and tested such that low-to-high cycling could be studied. The model was run through various load cycles; one of which is presented here. This modeling is a prototype for general use in developing cutting edge controls products and for maximizing economic, low-emissions, and efficient operation of the existing coal power fleet.

Braun, Timothy↗

Grid-Forming and Grid-Following Inverter Comparison of Droop Response

With the increase in penetration of inverter-based resources (IBRs) in the electrical power system, the ability of these devices to provide grid support to the system has become a necessity. With standards previously developed for the interconnection requirements of grid-following inverters (GFLI) (most commonly photovoltaic inverters), it has been well documented how these inverters “should” respond to changes in voltage and frequency. However, with other IBRs such as grid-forming inverters (GFMIs) (used for energy storage systems, standalone systems, and as uninterruptable power supplies) these requirements are either: not yet documented, or require a more in deep analysis. With the increased interest in microgrids, GFMIs that can be paralleled onto a distribution system have become desired. With the proper control schemes, a GFMI can help maintain grid stability through fast response compared to rotating machines. This paper will present an experimental comparison of commercially available GFMI and GFLI ' responses to voltage and frequency deviation, as well as the GFMI operating as a standalone system and subjected to various changes in loads.

Grid Support, Inverter, Droop Control, Volt-VAR, F↗