Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Performance-Aligned LLMs for Generating Fast HPC Code

Optimizing scientific software is a difficult task because codebases are often large and complex, and performance can depend upon several factors including the algorithm, its implementation, and hardware among others. Causes of poor performance can originate from disparate sources and be difficult to diagnose. Recent years have seen a multitude of work that use large language models (LLMs) to assist in software development tasks. However, these tools are trained to model the distribution of code as text, and are not specifically designed to understand performance aspects of code. In this work, we introduce a reinforcement learning based methodology to align the outputs of code LLMs with performance. This allows us to build upon the current code modeling capabilities of LLMs and extend them to generate better performing code. Here, we demonstrate that our fine-tuned model improves the expected speedup of generated code over base models for a set of benchmark tasks from 0.9 to 1.6 for serial code and 1.9 to 4.5 for OpenMP parallel code.

Computer science↗

Advanced truck and bus radial materials for fuel efficiencies (Final Report)

PPG Industries, Inc. and Bridgestone Americas Tire Operations (BATO) propose to develop a novel surface-modified silica technology and demonstrate 4-6% improved fuel efficiency of Truck and Bus Radial (TBR) tires built from the technology. The proposed fuel efficiency increase will be achieved while maintaining or improving tear strength and tread wear. During rubber mixing, distributing silica in the rubber matrix is a challenge. This is because silica has a very polar surface, while rubbers have little polarity. It was hypothesized that surface treatments could cover part of the surface by hydrophobic groups, and reduce the surface polarity, thus helping to wet the silica with rubber during mixing and improving silica dispersion. During the project, the effect of different silica surface treatments on the surface energy of silica were determined, and related to the silica dispersion in rubber compounds. The results demonstrated that reducing the surface energy of silica samples improved dispersion in rubber compounds. Also, the preference for silica to migrate to the different phases in polymer blends was determined. The studies performed in binary polymer blends showed that carbon black has a preference to distribute in the different polymer phases in the order: SBR>BR~NR. Commercially available silica samples (treated and untreated) showed a preference in the order of SBR>NR>BR. Finally, the silica prototypes showed a preference in the order SBR=NR>BR. The knowledge gained regarding dispersion of treated silicas in rubber compounds was used to perform a series of studies to develop a silica – rubber compound combination with optimum performance for TBR treads. Initially, two silica prototypes (BXR-990 and BXR-991) were developed and used for a tire build at BATO’s tire plant in Warren County, TN. Results were evaluated and further silica and compound optimization was performed, prior to a final tire build. Manufacturing of the final silica prototype (BXR-1006) for the final tire build was performed at the PPG Silicas Pilot Plant in Monroeville, PA. Afterwards, experimental tires with silica-filled treads and control tires with carbon black-filled treads were built at BATO’s Warren County tire plant. The experimental TBR tires with silica-filled treads achieved the project goals for lab performance indicators, tread hardness and tear strength. The tires showed a 2.2% improvement in fuel efficiency compared to the control tires. While this improvement is lower than the 4% goal set initially, the improvement is significant and there are indicators that up to a 5% improvement in fuel efficiency could be achieved. This is supported by the confirmation of the validity of the fuel efficiency indicators made at the beginning of the project, and by the improvement in hysteresis and rolling resistance from tires built earlier in the project. The experimental tires produced using the BXR-990 silica prototype showed 47% improvement in tan δ at 60°C and 16% improvement in rolling resistance. Based on the results obtained, it is valid to estimate that the tires built with BXR-990 could provide around a 5% improvement in fuel efficiency, should we perform a fuel efficiency test. Tire wear for the experimental tires was 31% worse than for the control tires with the carbon black-filled tread compound. Other tools and further analysis of factors affecting wear are necessary to be evaluated to produce a silica tire with wear comparable to carbon black. Experimental and control tires were provided to the DOE for independent testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Versatile Compressor Modeling using Approximation Techniques for Alternative Refrigerants Evaluation

Refrigerants are the life-blood of vapor compression systems that are widely used in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) applications. The HVAC&R community is currently transitioning from main-stream refrigerants that have high Global Warming Potential (GWP) to alternative lower-GWP refrigerants. During this transition, it is important to account for the life cycle climate performance of alternative refrigerants since their performance will be different than that of higher-GWP refrigerants. This requires the evaluation of the system performance with the new refrigerants. Unfortunately, it is extremely difficult to predict the realistic performance of new alternative refrigerants without experimental validation. One of the main challenges in this regard is modeling the compressor performance with high fidelity due to the complex interaction of operating parameters, geometry, boundary conditions, and fluid properties. High fidelity compressor models are computationally expensive and require significant pre-processing to evaluate the performance of alternative refrigerants. This paper presents a new approach to modeling compressor performance when alternative refrigerants are used. The new modeling concept relies on using existing compressor performance to create an approximate model that captures the dependence of compressor performance on key operating parameters and fluid properties. The model can be built using a myriad of approximation techniques. This paper focuses on Kriging-based techniques to develop higher fidelity approximate compressor models. Baseline and at least one alternative refrigerant performance data are used to build the model. The model accuracy was evaluated by comparing the model results with compressor performance data using other refrigerants. Preliminary results show that the approximate model can predict the compressor mass flow rate and power consumption within 5%.

Approximation↗

Large-scale seismic waveform quality metric calculation using Hadoop

Here in this work we investigated the suitability of Hadoop MapReduce and Apache Spark for large-scale computation of seismic waveform quality metrics by comparing their performance with that of a traditional distributed implementation. The Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC) provided 43 terabytes of broadband waveform data of which 5.1 TB of data were processed with the traditional architecture, and the full 43 TB were processed using MapReduce and Spark. Maximum performance of ~0.56 terabytes per hour was achieved using all 5 nodes of the traditional implementation. We noted that I/O dominated processing, and that I/O performance was deteriorating with the addition of the 5th node. Data collected from this experiment provided the baseline against which the Hadoop results were compared. Next, we processed the full 43 TB dataset using both MapReduce and Apache Spark on our 18-node Hadoop cluster. We conducted these experiments multiple times with various subsets of the data so that we could build models to predict performance as a function of dataset size. We found that both MapReduce and Spark significantly outperformed the traditional reference implementation. At a dataset size of 5.1 terabytes, both Spark and MapReduce were about 15 times faster than the reference implementation. Furthermore, our performance models predict that for a dataset of 350 terabytes, Spark running on a 100-node cluster would be about 265 times faster than the reference implementation. We do not expect that the reference implementation deployed on a 100-node cluster would perform significantly better than on the 5-node cluster because the I/O performance cannot be made to scale. Finally, we note that although Big Data technologies clearly provide a way to process seismic waveform datasets in a high-performance and scalable manner, the technology is still rapidly changing, requires a high degree of investment in personnel, and will likely require significant changes in other parts of our infrastructure. Nevertheless, we anticipate that as the technology matures and third-party tool vendors make it easier to manage and operate clusters, Hadoop (or a successor) will play a large role in our seismic data processing.

58 GEOSCIENCES↗

Electronic and Morphological Studies of Conjugated Polymers Incorporating a Disk-Shaped Polycyclic Aromatic Hydrocarbon Unit

As more research findings have shown the correlation between ordering in organic semiconductor thin films and device performance, it is becoming more essential to exercise control of the ordering through structural tuning. Many recent studies have focused on the influence of side chain engineering on polymer packing orientation in thin films. However, the impact of the size and conformation of aromatic surfaces on thin film ordering has not been investigated in great detail. Here we introduce a disk-shaped polycyclic aromatic hydrocarbon building block with a large π surface, namely, thienoazacoronenes (TACs), as a donor monomer for conjugated polymers. Here, a series of medium bandgap conjugated polymers have been synthesized by copolymerizing TAC with electron donating monomers of varying size. The incorporation of the TAC unit in such semiconducting polymers allows a systematic investigation, both experimentally and theoretically, of the relationships between polymer conformation, electronic structure, thin film morphology, and charge transport properties. Field effect transistors based on these polymers have shown good hole mobilities and photoresponses, proving that TAC is a promising building block for high performance optoelectronic materials.

36 MATERIALS SCIENCE↗

Design of a lens table for a double toroidal electron spectrometer

We report here on the method we developed to build a lens table for a four-element electrostatic transfer lens operated together with a double toroidal electron energy analyzer designed by one of us, and whose original design and further improvements are described in detail in Miron et al. [Rev. Sci. Instrum. 68, 3728 (1997)] and Le Guen et al. [Rev. Sci. Instrum. 73, 3885 (2002)]. Both computer simulations and laboratory instrument tuning were performed in order to build this lens table. The obtained result was tested for a broad range of electron kinetic energies and analyzer pass energies. Based on this new lens table, allowing to easily computer control the spectrometer working conditions, we could routinely achieve an electron energy resolution ranging between 0.6% and 0.8% of the analyzer pass energy, while the electron count rate was also significantly improved. The establishment of such a lens table is of high importance to relieve experimentalists from the tedious laboring of the lens optimization, which was previously necessary prior to any measurement. The described method can be adapted to any type of electron/ion energy analyzer, and will thus be interesting for all experimentalists who own, or plan to build or improve their charged particle energy analyzers.

43 PARTICLE ACCELERATORS↗

New Whole-House Solutions Case Study: Zero Energy Ready Home Multifamily Project: Mutual Housing at Spring Lake

Building cost effective, high performance homes that provide superior comfort, health, and durability is the goal of the Department of Energy's (DOE's) Zero Energy Ready Homes (ZERH) program. This case study describes the development of a 62-unit multifamily community constructed by nonprofit developer Mutual Housing at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project nationwide. Building America team Alliance for Residential Building Innovation worked with Mutual Housing throughout the project. An objective of this project was to gain a highly visible foothold for residential buildings built to the DOE ZERH specification that can be used to encourage participation by other California builders.

ARBI↗

Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders

The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. BSC consulted on the construction of five test houses by three Cold Climate production builders in three separate US cities. BSC worked with the builders to develop a design package tailored to the cost-related impacts for each builder. Therefore, the resulting design packages do vary from builder to builder. BSC provided support through this research project on the design, construction and performance testing of the five test homes. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations on the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: 1. Adding services to the scope of work for various trades, such as HERS Rater, HVAC contractor; 2. Increased material costs related to the checklists, especially the EPA Indoor airPLUS and EPA WaterSense(R) Efficient Hot Water Distribution requirement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Homes and Buildings, Continuum Magazine, Spring 2014 / Issue 6 (Book)

This issue of Continuum focuses on NREL's research to improve the energy efficiency of residential and commercial buildings. Heating, cooling, and lighting our homes and commercial structures account for more than 70% of all electricity used in the United States. That costs homeowners, businesses, and government agencies more than $400 billion annually, about 40% of our nation's total energy costs. Producing that energy contributes almost 40% of our nation's carbon dioxide emissions.By 2030, an estimated 900 billion square feet of new and rebuilt construction will be developed worldwide, providing an unprecedented opportunity to create efficient, sustainable buildings. Increasing the energy performance of our homes alone could potentially eliminate up to 160 million tons of greenhouse gas emissions and lower residential energy bills by $21 billion annually by the end of the decade.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Auditing Tool for Retrofit Building Projects [SWR-11-07]

Building energy auditors regularly use notepads, physical forms, or simple spreadsheets to inventory energy consuming devices in buildings and audit overall performance. Mobile computing devices such as smart phones or tablet computers with camera inputs may be used to automatically capture relevant information and format audit input in a way that streamlines work flows and reduces the likelihood of error. As an example. an auditor could walk through a space holding a mobile device, which automatically identifies and appliances, windows, etc. This information would automatically be added to a mobile database associated with the building for later integration with a larger building audit database. The user experience would require little or no manual input, and could integrate with tools to automate used to automate data collection for building energy modeling.

Parker, Andrew↗

BigData Express: Toward Schedulable, Predictable, and High-Performance Data Transfer

Big Data has emerged as a driving force for scientific discoveries. Large scientific instruments (e.g., colliders, and telescopes) generate exponentially increasing volumes of data. To enable scientific discovery, science data must be collected, indexed, archived, shared, and analyzed, typically in a widely distributed, highly collaborative manner. Data transfer is now an essential function for science discoveries, particularly within big data environments. Although significant improvements have been made in the area of bulk data transfer, the currently available data transfer tools and services can not successfully address the high-performance and time-constraint challenges of data transfer required by extreme-scale science applications for the following reasons: disjoint end-to-end data transfer loops, cross-interference between data transfers, and existing data transfer tools and services are oblivious to user requirements (deadline and QoS requirements). Fermilab has been working on the BigData Express project to address these problems. BigData Express seeks to provide a schedulable, predictable, and high-performance data transfer service for big data science. The BigData Express software is being deployed and evaluated at multiple research institutions, which include UMD, StarLight, FNAL, KISTI, KSTAR, SURFnet, Ciena, and other sites. Meanwhile, the BigData Express research team is collaborating with the StarLight International/National Communications Exchange Facility to deploy BigData Express at various research platforms, including Pacific Research Platform, National Research Platform, and Global Research Platform. It is envisioned that we are working toward building a high-performance data transfer federation for big data science.

Lu, Qiming↗

A Method to Test Model Calibration Techniques: Preprint

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method to Test Model Calibration Techniques

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SFRC Measurement Control Summary - FY23 Q3/Q4

Measurements with the Spent Fuel Rod Counter (SFRC) to be performed bi annually include 3 He detector efficiency checks (in both modules) and ion chamber channel tests with a pocket pulser. These measurements will all be performed at TA-35, building 27 where the SFRC is stored. Refer to LA-UR-22-31737 and LA-CP-22-20079 SFRC measurement control documents for a description of additional tests. Note that during this measurement period, counts could not be confirmed for the Si detectors, as an analog pulse to TTL box necessary for the DAQs to communicate with the detectors was still under construction. For this reason, typical measurements at the Calibrated Dose Facility were not performed for the second half of FY23. When these components are finished by the NEN electrical shop, the Si detectors will be implemented into these measurement control checks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

Brewer, Jeffrey C.↗

Next Generation Melter Testing for High Aluminum HLW Glasses (Final Report)

This Final Report describes the initial DuraMelter 100 (DM100) scale testing performed to support the development of next generation advanced joule-heated melters (NG AJHMs). The initial phase of testing investigated the impacts of plenum heaters and the partial drying of melter feed prior to its introduction into the melter. The tests demonstrate the overall impacts and benefits on processing characteristics such as increases in waste processing and glass production rates, and component volatility. The results also provide melting rates for sizing calculations and compatibility of feed and off-gas treatment systems. The tests were performed with a Hanford high level waste (HLW) composition previously processed on both the DM100 melter and the HLW Pilot Melter (DM1200). The simulated waste containing a high concentration of aluminum was originally specified by the Office of River Protection (ORP) for testing at VSL. This waste composition is representative of high-aluminum feeds that will be processed at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and that are expected to challenge waste loading and processing rate objectives. This works builds upon previous work performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) for ORP to increase waste loadings and waste processing rates for high aluminum HLW waste streams by glass formulation optimization, bubbling, and modest increases in melt temperature. The present tests were conducted in response to the Task Plan WP-4.1.4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗