Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

Controlling the delocalization-localization transition of light via electromagnetically induced transparency

We propose a scheme to realize a transition from delocalization to localization of light waves via electromagnetically induced transparency. The system we suggested is a resonant cold atomic ensemble having N configuration, with a control field consisting of two pairs of laser beams with different cross angles, which produce an electromagnetically induced quasiperiodic waveguide (EIQPW) for the propagation of a signal field. By appropriately tuning the incommensurate rate or relative modulation strength between the two pairs of control-field components, the signal field can exhibit the delocalization-localization transition as it transports inside the atomic ensemble. The delocalization-localization transition point is determined and the propagation property of the signal field is studied in detail. Our work provides a way of realizing wave localization via atomic coherence, which is quite different from the conventional, off-resonant mechanism-based Aubry-Andre model, and the great controllability of the EIQPW also allows an easy manipulation of the delocalization-localization transition.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observing a light dark matter beam with neutrino experiments

We consider the sensitivity of fixed-target neutrino experiments at the luminosity frontier to light stable states, such as those present in models of MeV-scale dark matter. To ensure the correct thermal relic abundance, such states must annihilate via light mediators, which in turn provide an access portal for direct production in colliders or fixed targets. Indeed, this framework endows the neutrino beams produced at fixed-target facilities with a companion 'dark matter beam', which may be detected via an excess of elastic scattering events off electrons or nuclei in the (near-)detector. We study the high-luminosity proton fixed-target experiments at LSND and MiniBooNE, and determine that the ensuing sensitivity to light dark matter generally surpasses that of other direct probes. For scenarios with a kinetically-mixed U(1){sup '} vector mediator of mass m{sub V}, we find that a large volume of parameter space is excluded for m{sub DM}{approx}1-5 MeV, covering vector masses 2m{sub DM} < or approx. m{sub V} < or approx. m{sub {eta}} and a range of kinetic mixing parameters reaching as low as {kappa}{approx}10{sup -5}. The corresponding MeV-scale dark matter scenarios motivated by an explanation of the galactic 511 keV line are thus strongly constrained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Current understanding and issues on electron beam injection in space

The status of the physics understanding involved in electron beam injection in space is reviewed. The paper examines our understanding of beam plasma interactions and their associated wave and energized particle spectra of the processes involved in the beam plasma discharge, and of the vehicle charge neutralization. 'Strawman' models are presented for comparison with experimental observations.

Papadopoulos, K.↗

Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams

Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51{+-}0.15 and 13.9{+-}0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20{+-}4% at 6 MV to 13{+-}4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degree sign at 6 MV and 1.8 deg. at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 deg. at 6 MV and 0.1 deg. at 18 MV. A method of determining source characteristics without mechanical modification of the treatment head, and therefore feasible in clinics, is presented. The energies and spectral widths determined using this method agree with those determined with only the exit window in the beam path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The CEBAF e{sup +} Footprint

The Continuous Electron Beam Accelerator Facility (CEBAF) at the Jefferson Laboratory (JLAB) is capable of accelerating e{sup -} to 6 GeV in energy. Presently CEBAF is being upgraded to a maximum energy of 12 GeV. In addition to e{sup -} scattering, the user community has expressed interest in performing e{sup +} scattering experiments with the upgraded CEBAF accelerator. This paper describes the existing and planned CEBAF accelerator complex, possible e{sup +} production locations and the expected e{sup +} beam qualities. Possibilities for production of e{sup +} at the JLAB free electron laser (FEL) is also briefly described.

43 PARTICLE ACCELERATORS↗

Persistent photoconductivity and photo-responsible defect in 30 MeV-electron irradiated single crystal ZnO

Persistent photoconductivity (PPC) in 30-MeV electron irradiated ZnO single crystals is studied by excitation using light emitting diodes (LEDs) with various wavelengths. The decay transient of the photoconductivity shows relaxation times in the range of a few ten days for the illumination at 90 K and a few hours at room temperature. An electron paramagnetic resonance (EPR) signal with g-value = 2.005 appears after illumination of blue LED, suggesting the transfer from the artificially introduced oxygen vacancy of 2+ charge state to the metastable + charge state. Once generated, the metastable state does not immediately decay into the 2+ charge state because of energetic barriers of approx190 meV, supporting the mechanism of PPC proposed by Van de Walle.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dielectric Studies on Swift Heavy Ions and Electron Irradiated Organic Single Crystal

Single crystals of 1-(4-methylphenyl)-3-(4,N,N-dimethylamino phenyl)-2-propen-1-one were irradiated with 72 MeV swift heavy ions of C-12 with different fluencies 5x10{sup 11}, 1x10{sup 12} and electrons with energy 8 MeV for a dose of 2.25 kGy. The changes in the dielectric properties of these crystals have been studied. The study shows that the dielectric constant increases first and then decreases with the increase of fluence. This variation has been discussed and possible explanations are given. The variation of dielectric loss and the ac conductivity indicates that there is some structural modification within the crystal due to irradiation. The electron irradiation induced ionic polarizibility within the crystal along the electron path, which is reflected in increase in dielectric constant and hence the conductivity.

36 MATERIALS SCIENCE↗

Probing Anti-Quark Structure in Proton with Drell-Yan at FNAL

E906/SeaQuest at FNAL is a fixed-target experiment to measure the Drell-Yan process with a 120-GeV proton beam and liquid-hydrogen/deuterium targets. The main purpose of this experiment is to precisely measure the asymmetry of u-bar and d-bar distributions in the proton at an x{sub Bj} range from 0.25 to 0.45. E906/SeaQuest is about to start a beam experiment. The physics capabilities and the current status of the experiment is reported in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-523: On the Radiobiological Impact of Lateral Scatter in Proton Beams

Introduction: In proton therapy, justified concern has been voiced with respect to an increased efficiency in cell kill at the distal end of the Bragg peak. This coupled with range uncertainty is a counter indication to use the Bragg peak to define the border of a treated volume with a critical organ. An alternative is to use the lateral edge of the proton beam, obtaining more robust plans. We investigate the spectral and biological effects of the lateral scatter . Methods: A general purpose Monte Carlo simulation engine (MCNPX 2.7c) installed on a Scientific Linux cluster, calculated the dose deposition spectrum of protons, knock on electrons and generated neutrons for a proton beam with maximal kinetic energy of 200MeV. Around the beam at different positions in the beam direction the spectrum is calculated in concentric rings of thickness 1cm. The deposited dose is converted to a double strand break map using an analytical expression.based on micro dosimetric calculations using a phenomenological Monte Carlo code (MCDS). A strict version of RBE is defined as the ratio of generation of double strand breaks in the different modalities. To generate the reference a Varian linac was modelled in MCNPX and the generated electron dose deposition spectrum was used . Results: On a pristine point source 200MeV beam the RBE before the Bragg peak was of the order of 1.1, increasing to 1.7 right behind the Bragg peak. When using a physically more realistic beam of 10cm diameter the effect was smaller. Both the lateral dose and RBE increased with increasing beam depth, generating a dose deposition with mixed biological effect. Conclusions: The dose deposition in proton beams need to be carefully examined because the biological effect will be different depending on the treatment geometry. Deeply penetrating proton beams generate more biologically effective lateral scatter.

07 ISOTOPE AND RADIATION SOURCES↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Hadron Physics with PANDA at FAIR

The recently established FAIR facility in Darmstadt has a broad program in the field of hadron and nuclear physics utilizing ion beams with unprecedented intensity and accuracy. The PANDA experiment, which is integrated in the HESR storage ring for antiprotons is at the center of the hadron physics program. It includes among others topics like hadron spectroscopy in the charmonium mass region and below, hyperon physics and electromagnetic processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

U.S. advanced and novel accelerator beam test facilities

Demonstrating the viability of Advanced Accelerator Concepts (AAC) relies on experimental validation. Over the last three decades, the U.S. has maintained a portfolio of advanced and novel accelerator test facilities to support research critical to AAC. The facilities have enabled pioneering developments in a wide variety of beam and accelerator physics, including plasma-wakefield and structure-wakefield acceleration. This work provides an overview of the current portfolio of U.S. facilities possessing charged particle drive beams with high energies, on the order of tens of joules per pulse, or drive lasers with high peak powers, on the order of a petawatt, and are actively conducting AAC research.

43 PARTICLE ACCELERATORS↗

US Advanced and Novel Accelerator Beam Test Facilities

Demonstrating the viability of Advanced Accelerator Concepts (AAC) relies on experimental validation. Over the last three decades, the US has maintained a portfolio of advanced and novel accelerator test facilities to support research critical to AAC. The facilities have enabled pioneering developments in a wide variety of beam and accelerator physics, including plasma-wakefeld and structure-wakefeld acceleration. This paper provides an overview of the current portfolio of US facilities possessing charged particle drive beams with high energies, on the order of tens of joules per pulse, or drive lasers with high peak powers, on the order of a petawatt, and are actively conducting AAC research.

Clarke, Christine↗

Physics potential of a long-baseline neutrino oscillation experiment using a J-PARC neutrino beam and Hyper-Kamiokande

Hyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of CP asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams. In this paper, the physics potential of a long baseline neutrino experiment using the Hyper-Kamiokande detector and a neutrino beam from the J-PARC proton synchrotron is presented. The analysis uses the framework and systematic uncertainties derived from the ongoing T2K experiment. With a total exposure of 7.5 MW × 107 sec integrated proton beam power (corresponding to 1.56×1022 protons on target with a 30 GeV proton beam) to a 2.5-degree off-axis neutrino beam, it is expected that the leptonic CP phase δCP can be determined to better than 19 degrees for all possible values of δCP, and CP violation can be established with a statistical significance of more than 3σ (5σ) for 76% (58%) of the δCP parameter space. Using both νe appearance and νμ disappearance data, the expected 1σ uncertainty of sin2θ23 is 0.015(0.006) for sin2θ23=0.5(0.45).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron irradiation induced reduction of the permittivity in chalcogenide glass (As{sub 2}S{sub 3}) thin film

In this paper, we investigate the effect of electron beam irradiation on the dielectric properties of As{sub 2}S{sub 3} chalcogenide glass. By means of low-loss electron energy loss spectroscopy, we derive the permittivity function, its dispersive relation, and calculate the refractive index and absorption coefficients under the constant permeability approximation. The measured and calculated results show a heretofore unseen phenomenon: a reduction in the permittivity of {>=}40%. Consequently a reduction of the refractive index of 20%, hence, suggests a conspicuous change in the optical properties of the material under irradiation with a 300 keV electron beam. The plausible physical phenomena leading to these observations are discussed in terms of the homopolar and heteropolar bond dynamics under high energy absorption. The reported phenomena, exhibited by As{sub 2}S{sub 3}-thin film, can be crucial for the development of photonics integrated circuits using electron beam irradiation method.

36 MATERIALS SCIENCE↗