Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Luminosity enhancement in relativistic jets and altered luminosity functions for beamed objects

Due to relativistic effects, the observed emission from relativistic jets is quite different from the rest frame emission. Systematic differences between the observed and intrinsic intensities of sources in which jet phenomena are occurring are discussed. Assuming that jets have a power law luminosity function of a slope B, the observed luminosity distribution as a function of the velocity of the jet, the spectral index of the rest frame emission, and the range of angles of the jets relative to our line of sight are calculated. The results is well-approximated by two power laws, the higher luminosity end having the original power law index X and the lower luminosity end having a flattened exponent independent of B and only slightly greater than 1. A model consisting of beamed emission from a jet and unbeamed emission from a stationary central component is investigated. The luminosity functions for these two-component sources are calculated for two ranges of angles. For sources in which beaming is important, the luminosity function is much flatter. Because of this, the relative numbers of ""beamed'' and ""unbeamed'' sources detected on the sky depend strongly on the luminosity at which the comparison is made.

Urry, C. M.↗

Luminosity enhancement in relativistic jets and altered luminosity functions for beamed objects

Due to relativistic effects, the observed emission from relativistic jets is quite different from the rest frame emission. Systematic differences between the observed and intrinsic intensities of sources in which jet phenomena are occurring are discussed. Assuming that jets have a power law luminosity function of a slope B, the observed luminosity distribution as a function of the velocity of the jet, the spectral index of the rest frame emission, and the range of angles of the jets relative to our line of sight are calculated. The results is well-approximated by two power laws, the higher luminosity end having the original power law index X and the lower luminosity end having a flattened exponent independent of B and only slightly greater than 1. A model consisting of beamed emission from a jet and unbeamed emission from a stationary central component is investigated. The luminosity functions for these two-component sources are calculated for two ranges of angles. For sources in which beaming is important, the luminosity function is much flatter. Because of this, the relative numbers of 'beamed' and 'unbeamed' sources detected on the sky depend strongly on the luminosity at which the comparison is made. Previously announced in STAR as N84-12889

Urry, C. M.↗

Harmonic response of cylindrical and toroidal shells to an internal acoustic field. I - Theory. II - Results

In the first part of the present work concerning the coupled elastic and acoustic response of a system of cylindrical and toroidal shells enclosing an acoustic medium, the theoretical model for the cylindrical and toroidal segments' elastodynamics incorporates an elastic simulation based on transfer matrices, while the acoustic simulation adapts Green's function and curved surface elements. The coupled response is determined by the equilibrium of the acoustic pressure and internal elastic reactions of the shell, and compatibility between acoustic and elastic accelerations at the shell-fluid interface. The second part of this work obtains and discusses numerical results based on the theory for the cases of shell configurations having a plane of symmetry, as well as asymmetric ones. The inadequacy of beam theory in modeling the response of short, thin shell configurations at frequencies above the fundamental elastic resonance is demonstrated.

El-Raheb, M.↗

Laser Beam Propagation Through Inhomogeneous Media with Shock-Like Profiles: Modeling and Computing

Wave propagation in inhomogeneous media has been studied for such diverse applications as propagation of radiowaves in atmosphere, light propagation through thin films and in inhomogeneous waveguides, flow visualization, and others. In recent years an increased interest has been developed in wave propagation through shocks in supersonic flows. Results of experiments conducted in the past few years has shown such interesting phenomena as a laser beam splitting and spreading. The paper describes a model constructed to propagate a laser beam through shock-like inhomogeneous media. Numerical techniques are presented to compute the beam through such media. The results of computation are presented, discussed, and compared with experimental data.

Adamovsky, Grigory↗

Confirmation of a Low {alpha}/{beta} Ratio for Prostate Cancer Treated by External Beam Radiation Therapy Alone Using a Post-Treatment Repeated-Measures Model for PSA Dynamics

Purpose: To estimate the {alpha}/{beta} ratio of prostate cancer treated with external beam radiation only by use of a model of long-term prostate-specific antigen (PSA) dynamics. Methods and Materials: Repeated measures of PSA from 5,093 patients from 6 institutions treated for localized prostate cancer by external beam radiation therapy (EBRT) without planned androgen deprivation were analyzed. A biphasic linear mixed model described the post-treatment evolution of PSA, rather than a conventional model of time to biochemical recurrence. The model was adjusted for standard prognostic factors (T stage, initial PSA level, and Gleason score) and cohort-specific effects. The radiation dose fractionation effect was estimated from the long-term rate of rise of PSA level. Results: Adjusted for other factors, total dose of EBRT and sum of squared doses per fraction were associated with long-term rate of change of PSA level (p = 0.0017 and p = 0.0003, respectively), an increase of each being associated with a lower rate of rise. The {alpha}/{beta} ratio was estimated at 1.55 Gy (95% confidence band, 0.46-4.52 Gy). This estimate was robust to adjustment of the linear mixed model. Conclusions: By analysis of a large EBRT-only cohort along with a method that uses all the repeated measures of PSA after the end of treatment, a low and precise {alpha}/{beta} was estimated. These data support the use of hypofractionation at fractional doses up to 2.8 Gy but cannot presently be assumed to accurately represent higher doses per fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct drive: Simulations and results from the National Ignition Facility

Direct-drive implosion physics is being investigated at the National Ignition Facility. The primary goal of the experiments is twofold: to validate modeling related to implosion velocity and to estimate the magnitude of hot-electron preheat. Implosion experiments indicate that the energetics is well-modeled when cross-beam energy transfer (CBET) is included in the simulation and an overall multiplier to the CBET gain factor is employed; time-resolved scattered light and scattered-light spectra display the correct trends. Trajectories from backlit images are well modeled, although those from measured self-emission images indicate increased shell thickness and reduced shell density relative to simulations. Sensitivity analyses indicate that the most likely cause for the density reduction is nonuniformity growth seeded by laser imprint and not laser-energy coupling. Hot-electron preheat is at tolerable levels in the ongoing experiments, although it is expected to increase after the mitigation of CBET. Future work will include continued model validation, imprint measurements, and mitigation of CBET and hot-electron preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Flexure-Based Mechanism for Precision Adjustment of National Ignition Facility Target Shrouds in Three Rotational Degrees of Freedom

This study presents the design of a flexure-based mount allowing adjustment in three rotational degrees of freedom (DOFs) through high-precision set-screw actuators. The requirements of the application called for small but controlled angular adjustments for mounting a cantilevered beam. The proposed design is based on an array of parallel beams to provide sufficiently high stiffness in the translational directions while allowing angular adjustment through the actuators. A simplified physical model in combination with standard beam theory was applied to estimate the deflection profile and maximum stresses in the beams. A finite element model was built to calculate the stresses and beam profiles for scenarios in which the flexure is simultaneously actuated in more than one DOF.

3 DOF↗

Symmetry tuning via controlled crossed-beam energy transfer on the National Ignition Facility

The hohlraum energetics experimental campaign started in the summer of 2009 on the national Ignition Facility (NIF) (cf. N. Meezan et al., Phys. Plasmas, this issue). These experiments have demonstrated controlled crossed-beam transfer as an efficient and robust tool to tune the implosion symmetry of ignition capsules. A new linear model calculating crossed-beam energy transfer between cones of beams on the NIF has been developed. The model has been applied to the emulator targets shot for the National Ignition Campaign in 2009. These targets have no lip liner at the laser entrance holes, which reduces the amount of energy transfer between laser beams and requires a larger wavelength separation between the cones of laser beams in order to achieve the best symmetry (with no net transfer between the inner and outer cones). A good agreement is found between the calculations and measurements; remaining discrepancies can be explained by a 10% error in modeling the flow at the laser entrance hole of ignitions hohlraums.

42 ENGINEERING↗

Transformer ratio improvement for beam based plasma accelerators

Increasing the transformer ratio of wakefield accelerating systems improves the viability of present novel accelerating schemes. The use of asymmetric bunches to improve the transformer ratio of beam based plasma systems has been proposed for some time[1, 2] but suffered from lack appropriate beam creation systems. Recently these impediments have been overcome [3, 4] and the ability now exists to create bunches with current profiles shaped to overcome the symmetric beam limit of R {<=} 2. We present here work towards experiments designed to measure the transformer ratio of such beams, including theoretical models and simulations using VORPAL (a 3D capable PIC code) [5]. Specifically we discuss projects to be carried out in the quasi-nonlinear regime [6] at the UCLA Neptune Laboratory and the Accelerator Test Facility at Brookhaven National Lab.

43 PARTICLE ACCELERATORS↗

SU-F-T-142: An Analytical Model to Correct the Aperture Scattered Dose in Clinical Proton Beams

Purpose: Apertures or collimators are used to laterally shape proton beams in double scattering (DS) delivery and to sharpen the penumbra in pencil beam (PB) delivery. However, aperture-scattered dose is not included in the current dose calculations of treatment planning system (TPS). The purpose of this study is to provide a method to correct the aperture-scattered dose based on an analytical model. Methods: A DS beam with a non-divergent aperture was delivered using a single-room proton machine. Dose profiles were measured with an ion-chamber scanning in water and a 2-D ion chamber matrix with solid-water buildup at various depths. The measured doses were considered as the sum of the non-contaminated dose and the aperture-scattered dose. The non-contaminated dose was calculated by TPS and subtracted from the measured dose. Aperture scattered-dose was modeled as a 1D Gaussian distribution. For 2-D fields, to calculate the scatter-dose from all the edges of aperture, a sum of weighted distance was used in the model based on the distance from calculation point to aperture edge. The gamma index was calculated between the measured and calculated dose with and without scatter correction. Results: For a beam with range of 23 cm and aperture size of 20 cm, the contribution of the scatter horn was ∼8% of the total dose at 4 cm depth and diminished to 0 at 15 cm depth. The amplitude of scatter-dose decreased linearly with the depth increase. The 1D gamma index (2%/2 mm) between the calculated and measured profiles increased from 63% to 98% for 4 cm depth and from 83% to 98% at 13 cm depth. The 2D gamma index (2%/2 mm) at 4 cm depth has improved from 78% to 94%. Conclusion: Using the simple analytical method the discrepancy between the measured and calculated dose has significantly improved.

60 APPLIED LIFE SCIENCES↗

Uniform Decay for Solutions of an Axially Moving Viscoelastic Beam

The paper deals with an axially moving viscoelastic structure modeled as an Euler–Bernoulli beam. The aim is to suppress the transversal displacement (transversal vibrations) that occur during the axial motion of the beam. It is assumed that the beam is moving with a constant axial speed and it is subject to a nonlinear force at the right boundary. We prove that when the axial speed of the beam is smaller than a critical value, the dissipation produced by the viscoelastic material is sufficient to suppress the transversal vibrations. It is shown that the rate of decay of the energy depends on the kernel which arise in the viscoelastic term. We consider a general kernel and notice that solutions cannot decay faster than the kernel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fundamental radiological and geometric performance of two types of proton beam modulated discrete scanning systems

Purpose: The purpose of this investigation was to compare and contrast the measured fundamental properties of two new types of modulated proton scanning systems. This provides a basis for clinical expectations based on the scanned beam quality and a benchmark for computational models. Because the relatively small beam and fast scanning gave challenges to the characterization, a secondary purpose was to develop and apply new approaches where necessary to do so.Methods: The following performances of the proton scanning systems were investigated: beamlet alignment, static in-air beamlet size and shape, scanned in-air penumbra, scanned fluence map accuracy, geometric alignment of scanning system to isocenter, maximum field size, lateral and longitudinal field uniformity of a 1 l cubic uniform field, output stability over time, gantry angle invariance, monitoring system linearity, and reproducibility. A range of detectors was used: film, ionization chambers, lateral multielement and longitudinal multilayer ionization chambers, and a scintillation screen combined with a digital video camera. Characterization of the scanned fluence maps was performed with a software analysis tool.Results: The resulting measurements and analysis indicated that the two types of delivery systems performed within specification for those aspects investigated. The significant differences were observed between the two types of scanning systems where one type exhibits a smaller spot size and associated penumbra than the other. The differential is minimum at maximum energy and increases inversely with decreasing energy. Additionally, the large spot system showed an increase in dose precision to a static target with layer rescanning whereas the small spot system did not.Conclusions: The measured results from the two types of modulated scanning types of system were consistent with their designs under the conditions tested. The most significant difference between the types of system was their proton spot size and associated resolution, factors of magnetic optics, and vacuum length. The need and benefit of mutielement detectors and high-resolution sensors was also shown. The use of a fluence map analytical software tool was particularly effective in characterizing the dynamic proton energy-layer scanning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Altimeter for Flight Simulator

Height of flight-simulator probe above model of terrain measured by automatic laser triangulation system. Airplane simulated by probe that moves over model of terrain. Altitude of airplane scaled from height of probe above model. Height measured by triangulation of laser beam aimed at intersection of model surface with plumb line of probe.

Webster, L. D.↗

Photochemical Internalization of Bleomycin Before External-Beam Radiotherapy Improves Locoregional Control in a Human Sarcoma Model

Purpose: The aim of this study was to explore the tumor growth response of the combination photochemical internalization and external-beam radiotherapy. Photochemical internalization is a technology to improve the utilization of therapeutic macromolecules in cancer therapy by photochemical release of endocytosed macromolecules into the cytosol. Methods and Materials: A human sarcoma xenograft TAX-1 was inoculated subcutaneously into nude mice. The photosensitizer AlPcS{sub 2a} and bleomycin were intraperitoneally administrated 48 h and 30 min, respectively, before diode laser light exposure at 670 nm (20 J/cm{sup 2}). Thirty minutes or 7 days after photochemical treatment, the animals were subjected to 4 Gy of ionizing radiation. Results: Using photochemical internalization of bleomycin as an adjunct to ionizing radiation increased the time to progression for the tumors from 17 to 33 days as compared with that observed with photodynamic therapy combined with ionizing radiation as well as for radiochemotherapy with bleomycin. The side effects observed when photochemical internalization of bleomycin was given shortly before ionizing radiation were eliminated by separating the treatment modalities in time. Conclusion: Photochemical internalization of bleomycin combined with ionizing radiation increased the time to progression and showed minimal toxicity and may therefore reduce the total radiation dose necessary to obtain local tumor control while avoiding long-term sequelae from radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Surface electronic structure for various surface preparations of Nb-doped SrTiO{sub 3} (001)

High-resolution angle-resolved photoemission spectroscopy (ARPES) was used to study the surface electronic structure of Nb-doped SrTiO{sub 3} (STO) single crystals prepared using a variety of surface preparations. ARPES measurements show that simple degreasing with subsequent anneal in vacuum is not an adequate surface preparation of STO, rather, preparations consisting of etching with buffered HF or HCl, and to a lesser extent, simple water leaching resulted in surfaces with much less disorder. A non-dispersing, mid-gap state was found ∼800 meV above the top of the valence band for samples which underwent etching. This mid-gap state is not present for vacuum-annealed and water-leached samples, as well as for STO thin films grown using molecular beam epitaxy. Theoretical modeling using density functional theory suggests that this mid-gap state is not related to the SrO- and TiO{sub 2}-terminated surfaces, but rather, is due to a partial hydrogenation of the STO surface that occurs during etching.

36 MATERIALS SCIENCE↗

Dynamics of submicron aerosol droplets in a robust optical trap formed by multiple Bessel beams

In this paper, we model the three-dimensional escape dynamics of single submicron-sized aerosol droplets in optical multiple Bessel beam traps. Trapping in counter-propagating Bessel beams (CPBBs) is compared with a newly proposed quadruple Bessel beam (QBB) trap, which consists of two perpendicularly arranged CPBB traps. Calculations are performed for perfectly and imperfectly aligned traps. Mie-theory and finite-difference time-domain methods are used to calculate the optical forces. The droplet escape kinetics are obtained from the solution of the Langevin equation using a Verlet algorithm. Provided the traps are perfectly aligned, the calculations indicate very long lifetimes for droplets trapped either in the CPBB or in the QBB trap. However, minor misalignments that are hard to control experimentally already severely diminish the stability of the CPBB trap. By contrast, such minor misalignments hardly affect the extended droplet lifetimes in a QBB trap. The QBB trap is found to be a stable, robust optical trap, which should enable the experimental investigation of submicron droplets with radii down to 100 nm. Optical binding between two droplets and its potential role in preventing coagulation when loading a CPBB trap is briefly addressed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗