Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Radiation-induced DNA damage and the relative biological effectiveness of 18 F-FDG in wild-type mice

Clinically, the most commonly used positron emission tomography (PET) radiotracer is the glucose analog 2-[ 18 F] fluoro-2-deoxy-d-glucose ( 18 F-FDG), however little research has been conducted on the biological effects of 18 F-FDG injections. The induction and repair of DNA damage and the relative biological effectiveness (RBE) of radiation from 18 F-FDG relative to 662 keV γ-rays were investigated. The study also assessed whether low-dose radiation exposure from 18 F-FDG was capable of inducing an adaptive response. DNA damage to the bone marrow erythroblast population was measured using micronucleus formation and lymphocyte γH2A.X levels. To test the RBE of 18 F-FDG, mice were injected with a range of activities of 18 F-FDG (0–14.80 MBq) or irradiated with Cs-137 γ-rays (0–100 mGy). The adaptive response was investigated 24 h after the 18 F-FDG injection by 1 Gy in vivo challenge doses for micronucleated reticulocyte (MN-RET) formation or 1, 2 and 4 Gy in vitro challenges doses for γH2A.X formation. A significant increase in MN-RET formation above controls occurred following injection activities of 3.70, 7.40 or 14.80 MBq (P < 0.001) which correspond to bone marrow doses of ~35, 75 and 150 mGy, respectively. Per unit dose, the Cs-137 radiation exposure induced significantly more damage than the 18 F-FDG injections (RBE = 0.79 ± 0.04). A 20% reduction in γH2A.X fluorescence was observed in mice injected with a prior adapting low dose of 14.80 MBq 18 F-FDG relative to controls (P < 0.019). A 0.74 MBq 18 F-FDG injection, which gives mice a dose approximately equal to a typical human PET scan, did not cause a significant increase in DNA damage nor did it generate an adaptive response. Typical 18 F-FDG injection activities used in small animal imaging (14.80 MBq) resulted in a decrease in DNA damage, as measured by γH2A.X formation, below spontaneous levels observed in control mice. Lastly, the 18 F-FDG RBE was <1.0, indicating that the mixed radiation quality and/or low dose rate from PET scans is less damaging than equivalent doses of gamma radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-41: Regularized PCA Can Model Treatment-Related Changes in Head and Neck Patients Using Daily CBCTs

Purpose: To use daily cone beam CTs (CBCTs) to develop regularized principal component analysis (PCA) models of anatomical changes in head and neck (H&N) patients, to guide replanning decisions in adaptive radiation therapy (ART). Methods: Known deformations were applied to planning CT (pCT) images of 10 H&N patients to model several different systematic anatomical changes. A Pinnacle plugin was used to interpolate systematic changes over 35 fractions, generating a set of 35 synthetic CTs for each patient. Deformation vector fields (DVFs) were acquired between the pCT and synthetic CTs and random fraction-to-fraction changes were superimposed on the DVFs. Standard non-regularized and regularized patient-specific PCA models were built using the DVFs. The ability of PCA to extract the known deformations was quantified. PCA models were also generated from clinical CBCTs, for which the deformations and DVFs were not known. It was hypothesized that resulting eigenvectors/eigenfunctions with largest eigenvalues represent the major anatomical deformations during the course of treatment. Results: As demonstrated with quantitative results in the supporting document regularized PCA is more successful than standard PCA at capturing systematic changes early in the treatment. Regularized PCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes. To be successful at guiding ART, regularized PCA should be coupled with models of when anatomical changes occur: early, late or throughout the treatment course. Conclusion: The leading eigenvector/eigenfunction from the both PCA approaches can tentatively be identified as a major systematic change during radiotherapy course when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the regularized PCA approach appears to be more reliable at capturing systematic changes, enabling dosimetric consequences to be projected once trends are established early in the treatment course. This work is supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

An ALMA and MagAO Study of the Substellar Companion GQ Lup B

Multi-wavelength observations provide a complementary view of the formation of young, directly imaged planet-mass companions. We report the ALMA 1.3 mm and Magellan adaptive optics Hα, i{sup ′}, z{sup ′}, and Y {sub S} observations of the GQ Lup system, a classical T Tauri star with a 10--40 M{sub Jup} substellar companion at ∼110 au projected separation. We estimate the accretion rates for both components from the observed Hα fluxes. In our ∼0.″05 resolution ALMA map, we resolve GQ Lup A’s disk in the dust continuum, but no signal is found from the companion. The disk is compact, with a radius of ∼22 au, a dust mass of ∼6 M {sub ⊕}, an inclination angle of ∼56°, and a very flat surface density profile indicative of a radial variation in dust grain sizes. No gaps or inner cavity are found in the disk, so there is unlikely a massive inner companion to scatter GQ Lup B outward. Thus, GQ Lup B might have formed in situ via disk fragmentation or prestellar core collapse. We also show that GQ Lup A’s disk is misaligned with its spin axis, and possibly with GQ Lup B’s orbit. Our analysis on the tidal truncation radius of GQ Lup A’s disk suggests that GQ Lup B’s orbit might have a low eccentricity.

79 ASTRONOMY AND ASTROPHYSICS↗

Apollo contamination analysis

The Apollo 12 photographic observations of clouds produced by venting liquids into space were reduced and analyzed. The number of Baker-Nunn photographs required that film measurement and data processing be automated, and the microdensitometer was adapted to automatic digital operation. Computer programs were prepared to process the image-density measurements. A substantial selection of Apollo 12 data was processed; both hydrogen and oxygen clouds are represented. Some limited data were obtained from Apollo 13 and 14 missions. During the Apollo 12 data analysis, the theory and models of cloud phenomena were refined because the models were initially applied to inferior oxygen data from earlier missions. The reported observations of water dumps from Apollo 12 are also discussed, along with the use of the oxygen and hydrogen data from Apollo 12 photographs with the cloud models.

Source record↗

Design and fabrication of an experimental image forming light modulator

Image forming light modulator transforms electrical signal representation of two dimensional image into optical transparency. All major assemblies are easily demounted for convenience in adapting modulator to other operating modes with different modulation-media. High-speed vacuum pump is incorporated into modulator housing to help reach required operating pressure.

Shackelford, R. G.↗

Simultaneous observations by television camera and radar

The original image-orthicon equipment used for simultaneous radar and optical observations is described. The adaptations made to enhance its usefulness for meteor observations, and the specialized calibration and photometric procedures developed for this purpose are also described. Some brief comments concerning the use of the secondary electron conduction vidicon are included.

Mccrosky, R. E.↗

LANDSAT-4 MSS interband registration

Interband registration on raw LANDSAT-4 MSS data was measured in the four MSS bands of the Mistassini, Quebec scene (path-row 16-24, June 21, 1983). Statistical comparison between line-pixel locations of uniformly distributed ground control points in the four different bands permitted quantitative measures of the offset over the entire scene. The statistical distribution of the offset measures permitted evaluation of the standard error on the mean values, giving confidence on their precision. Results obtained using a manual ground control point done on a digital image correction system and those obtained using digital band-to-band correlation adapted from a digital stereographic correlation algorithm are tabulated. The pixel misrepresentation values obtained are compared with published NASA figures.

Grieve, G.↗

A methodology to emulate and evaluate a productive virtual workstation

The Advanced Display and Computer Augmented Control (ADCACS) Program at ACT is sponsored by NASA Ames to investigate the broad field of technologies which must be combined to design a 'virtual' workstation for the Space Station Freedom. This program is progressing in several areas and resulted in the definition of requirements for a workstation. A unique combination of technologies at the ACT Laboratory have been networked to effectively create an experimental environment. This experimental environment allows the integration of nonconventional input devices with a high power graphics engine within the framework of an expert system shell which coordinates the heterogeneous inputs with the 'virtual' presentation. The flexibility of the workstation is evolved as experiments are designed and conducted to evaluate the condition descriptions and rule sets of the expert system shell and its effectiveness in driving the graphics engine. Workstation productivity has been defined by the achievable performance in the emulator of the calibrated 'sensitivity' of input devices, the graphics presentation, the possible optical enhancements to achieve a wide field of view color image and the flexibility of conditional descriptions in the expert system shell in adapting to prototype problems.

Krubsack, David↗

A Substellar Companion to Pleiades HII 3441

We find a new substellar companion to the Pleiades member star, Pleiades HII 3441, using the Subaru telescope with adaptive optics. The discovery is made as part of the high-contrast imaging survey to search for planetary-mass and substellar companions in the Pleiades and young moving groups. The companion has a projected separation of 0". 49+/-0". 02 (66+/-2 au) and a mass of 68+/-5M(sub J) based on three observations in the J-, H-, and K(sub s)-bands. The spectral type is estimated to be M7 (approx. 2700 K), and thus no methane absorption is detected in the H band. Our Pleiades observations result in the detection of two substellar companions including one previously reported among 20 observed Pleiades stars, and indicate that the fraction of substellar companions in the Pleiades is about 10.0+26.1 −8.8 %. This is consistent with multiplicity studies of both the Pleiades stars and other open clusters.

Pleiades HII 3441↗

BANYAN. VI. Discovery of a companion at the Brown dwarf/planet-mass limit to a Tucana–horologium M dwarf

We report the discovery of a substellar companion to 2MASS J02192210–3925225, a young M6 γ candidate member of the Tucana–Horologium association (30–40 Myr). This L4 γ companion has been discovered with seeing-limited direct imaging observations; at a 4″ separation (160 AU) and a modest contrast ratio, it joins the very short list of young low-mass companions amenable to study without the aid of adaptive optics, enabling its characterization with a much wider suite of instruments than is possible for companions uncovered by high-contrast imaging surveys. With a model-dependent mass of 12–15 M{sub Jup}, it straddles the boundary between the planet and brown dwarf mass regimes. We present near-infrared spectroscopy of this companion and compare it to various similar objects uncovered in the last few years. The J0219–3925 system falls in a sparsely populated part of the host mass versus mass ratio diagram for binaries; the dearth of known similar companions may be due to observational biases in previous low-mass companion searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of Transport Properties of Woody Biomass Feedstock Particles Before and After Pyrolysis by Numerical Analysis of X-Ray Tomographic Reconstructions

Lignocellulosic biomass has a complex, species-specific microstructure that governs heat and mass transport during conversion processes. A quantitative understanding of the evolution of pore size and structure is critical to optimize conversion processes for biofuel and bio-based chemical production. Further, improving our understanding of the microstructure of biochar coproduct will accelerate development of its myriad applications. This work quantitatively compares the microstructural features and the anisotropic permeabilities of two woody feedstocks, red oak and Douglas fir, using X-ray computed tomography (XCT) before and after the feedstocks are subjected to pyrolysis. Quantitative analysis of the three-dimensional (3D) reconstructions allows for direct calculations of void fractions, pore size distributions and tortuosity factors. Next, 3D images are imported into an immersed boundary based finite volume solver to simulate gas flow through the porous structure and to directly calculate the principal permeabilities along longitudinal, radial, and tangential directions. The permeabilities of native biomass are seen to differ by three to four orders of magnitude in the different principal directions, but we find that this anisotropy is substantially reduced in the biochar formed during pyrolysis. The quantitative transport properties reported here enhance the ability of pyrolysis simulations to account for feedstock-specific effects and thereby provide a useful touchstone for the biorefining community.

09 BIOMASS FUELS↗

Sub-Wavelength Imaging of Photo-Induced Refractive Index Pattern in Chalcogenide Glass Films

Mapping of refractive index patterns with sub-wavelength resolution is achieved using Near-field Scanning Optical Microscopy (NSOM) in reflection mode. Imaging of index pattern is performed on surface gratings photo-imprinted in As2S3 films. The NSOM is adapted with a near infrared laser which wavelength (785 nm) is chosen to be within the transparency window of the glass film therefore allowing consistent measure of reflected light. Quantitative measurements of photo-induced index changes can then be obtained from knowledge of the initial film index. Images of gratings with a period of 0.5 micron are easily collected therefore demonstrating sub-wavelength spatial resolution. The technique permits to concurrently obtain a topographic image and index image of the gratings thereby permitting to quantify the extent of photodarkening and photoexpansion simultaneously. It is shown that relief gratings tend to vanish in films aged in air for several months however the index gratings remain.

36 MATERIALS SCIENCE↗

Objective assessment in digital images of skin erythema caused by radiotherapy

Purpose: Skin toxicity caused by radiotherapy has been visually classified into discrete grades. The present study proposes an objective and continuous assessment method of skin erythema in digital images taken under arbitrary lighting conditions, which is the case for most clinical environments. The purpose of this paper is to show the feasibility of the proposed method. Methods: Clinical data were gathered from six patients who received carbon beam therapy for lung cancer. Skin condition was recorded using an ordinary compact digital camera under unfixed lighting conditions; a laser Doppler flowmeter was used to measure blood flow in the skin. The photos and measurements were taken at 3 h, 30, and 90 days after irradiation. Images were decomposed into hemoglobin and melanin colors using independent component analysis. Pixel values in hemoglobin color images were compared with skin dose and skin blood flow. The uncertainty of the practical photographic method was also studied in nonclinical experiments. Results: The clinical data showed good linearity between skin dose, skin blood flow, and pixel value in the hemoglobin color images; their correlation coefficients were larger than 0.7. It was deduced from the nonclinical that the uncertainty due to the proposed method with photography was 15%; such an uncertainty was not critical for assessment of skin erythema in practical use. Conclusions: Feasibility of the proposed method for assessment of skin erythema using digital images was demonstrated. The numerical relationship obtained helped to predict skin erythema by artificial processing of skin images. Although the proposed method using photographs taken under unfixed lighting conditions increased the uncertainty of skin information in the images, it was shown to be powerful for the assessment of skin conditions because of its flexibility and adaptability.

60 APPLIED LIFE SCIENCES↗

TH-C-BRF-01: The Promise and Potential Pitfalls of Deformable Image Registration in Clinical Practice

Accurate and robust deformable image registration (DIR) is a key enabling technique in the clinical realization of two approaches for advancing radiation therapy treatment efficacy: adaptive radiation therapy and treatment response assessment. Currently there are a wide variety of DIR methods including the categories of splines, optical/diffusion, free-form, and biomechanical algorithms. All methods aim to translate information between image sets (including multi-modal data) in the presence of spatial deformation of tissues. However, recent research has shown that different DIR algorithms can yield substantially different results for the same reference deformation, and that DIR performance can be site and application dependent. As a result, errors can occur, and subsequent patient treatment can be compromised. There is a clear need for greater understanding of appropriate use of DIR techniques, as well as effective methods of validation, evaluation, and improvement. In this session, we will review the state-of-the-art concerning DIR development, clinical application, and performance evaluation. Novel DIR methods and evaluating technologies will be reviewed. Learning Objectives: To understand the underlying principles and physics of current DIR techniques To explore potential clinical applications and areas of high impact for DIR To investigate sources of uncertainty, appropriate usage, and methods for validating and evaluating DIR performance.

60 APPLIED LIFE SCIENCES↗

A visual detection model for DCT coefficient quantization

The discrete cosine transform (DCT) is widely used in image compression and is part of the JPEG and MPEG compression standards. The degree of compression and the amount of distortion in the decompressed image are controlled by the quantization of the transform coefficients. The standards do not specify how the DCT coefficients should be quantized. One approach is to set the quantization level for each coefficient so that the quantization error is near the threshold of visibility. Results from previous work are combined to form the current best detection model for DCT coefficient quantization noise. This model predicts sensitivity as a function of display parameters, enabling quantization matrices to be designed for display situations varying in luminance, veiling light, and spatial frequency related conditions (pixel size, viewing distance, and aspect ratio). It also allows arbitrary color space directions for the representation of color. A model-based method of optimizing the quantization matrix for an individual image was developed. The model described above provides visual thresholds for each DCT frequency. These thresholds are adjusted within each block for visual light adaptation and contrast masking. For given quantization matrix, the DCT quantization errors are scaled by the adjusted thresholds to yield perceptual errors. These errors are pooled nonlinearly over the image to yield total perceptual error. With this model one may estimate the quantization matrix for a particular image that yields minimum bit rate for a given total perceptual error, or minimum perceptual error for a given bit rate. Custom matrices for a number of images show clear improvement over image-independent matrices. Custom matrices are compatible with the JPEG standard, which requires transmission of the quantization matrix.

Ahumada, Albert J., Jr.↗

Scatter correction for cone-beam CT in radiation therapy

Cone-beam CT (CBCT) is being increasingly used in modern radiation therapy for patient setup and adaptive replanning. However, due to the large volume of x-ray illumination, scatter becomes a rather serious problem and is considered as one of the fundamental limitations of CBCT image quality. Many scatter correction algorithms have been proposed in literature, while a standard practical solution still remains elusive. In radiation therapy, the same patient is scanned repetitively during a course of treatment, a natural question to ask is whether one can obtain the scatter distribution on the first day of treatment and then use the data for scatter correction in the subsequent scans on different days. To realize this scatter removal scheme, two technical pieces must be in place: (i) A strategy to obtain the scatter distribution in on-board CBCT imaging and (ii) a method to spatially match a prior scatter distribution with the on-treatment CBCT projection data for scatter subtraction. In this work, simple solutions to the two problems are provided. A partially blocked CBCT is used to extract the scatter distribution. The x-ray beam blocker has a strip pattern, such that partial volume can still be accurately reconstructed and the whole-field scatter distribution can be estimated from the detected signals in the shadow regions using interpolation/extrapolation. In the subsequent scans, the patient transformation is determined using a rigid registration of the conventional CBCT and the prior partial CBCT. From the derived patient transformation, the measured scatter is then modified to adapt the new on-treatment patient geometry for scatter correction. The proposed method is evaluated using physical experiments on a clinical CBCT system. On the Catphan(c)600 phantom, the errors in Hounsfield unit (HU) in the selected regions of interest are reduced from about 350 to below 50 HU; on an anthropomorphic phantom, the error is reduced from 15.7% to 5.4%. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPEQTACLE: An automated generalized fuzzy C-means algorithm for tumor delineation in PET

Purpose: Accurate tumor delineation in positron emission tomography (PET) images is crucial in oncology. Although recent methods achieved good results, there is still room for improvement regarding tumors with complex shapes, low signal-to-noise ratio, and high levels of uptake heterogeneity. Methods: The authors developed and evaluated an original clustering-based method called spatial positron emission quantification of tumor—Automatic Lp-norm estimation (SPEQTACLE), based on the fuzzy C-means (FCM) algorithm with a generalization exploiting a Hilbertian norm to more accurately account for the fuzzy and non-Gaussian distributions of PET images. An automatic and reproducible estimation scheme of the norm on an image-by-image basis was developed. Robustness was assessed by studying the consistency of results obtained on multiple acquisitions of the NEMA phantom on three different scanners with varying acquisition parameters. Accuracy was evaluated using classification errors (CEs) on simulated and clinical images. SPEQTACLE was compared to another FCM implementation, fuzzy local information C-means (FLICM) and fuzzy locally adaptive Bayesian (FLAB). Results: SPEQTACLE demonstrated a level of robustness similar to FLAB (variability of 14% ± 9% vs 14% ± 7%, p = 0.15) and higher than FLICM (45% ± 18%, p < 0.0001), and improved accuracy with lower CE (14% ± 11%) over both FLICM (29% ± 29%) and FLAB (22% ± 20%) on simulated images. Improvement was significant for the more challenging cases with CE of 17% ± 11% for SPEQTACLE vs 28% ± 22% for FLAB (p = 0.009) and 40% ± 35% for FLICM (p < 0.0001). For the clinical cases, SPEQTACLE outperformed FLAB and FLICM (15% ± 6% vs 37% ± 14% and 30% ± 17%, p < 0.004). Conclusions: SPEQTACLE benefitted from the fully automatic estimation of the norm on a case-by-case basis. This promising approach will be extended to multimodal images and multiclass estimation in future developments.

60 APPLIED LIFE SCIENCES↗

Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective

Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR Trade-Mark-Sign ) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR Trade-Mark-Sign . Empirically derived dose reduction limits were established for ASiR Trade-Mark-Sign for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metric was tested using the ACR CT phantom with 0%-100% ASiR Trade-Mark-Sign blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR Trade-Mark-Sign implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR Trade-Mark-Sign reconstruction to maintain noise equivalence of the 0% ASiR Trade-Mark-Sign image. Results: The ASiR Trade-Mark-Sign algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR Trade-Mark-Sign reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR Trade-Mark-Sign presented a more smoothed appearance than the pre-ASiR Trade-Mark-Sign 100% FBP image. Finally, relative to non-ASiR Trade-Mark-Sign images with 100% of standard dose across the pediatric phantom age spectrum, similar noise levels were obtained in the images at a dose reduction of 48% with 40% ASIR Trade-Mark-Sign and a dose reduction of 82% with 100% ASIR Trade-Mark-Sign . Conclusions: The authors' work was conducted to identify the dose reduction limits of ASiR Trade-Mark-Sign for a pediatric oncology population using automatic tube current modulation. Improvements in noise levels from ASiR Trade-Mark-Sign reconstruction were adapted to provide lower radiation exposure (i.e., lower mA) instead of improved image quality. We have demonstrated for the image quality standards required at our institution, a maximum dose reduction of 82% can be achieved using 100% ASiR Trade-Mark-Sign ; however, to negate changes in the appearance of reconstructed images using ASiR Trade-Mark-Sign with a medium to low frequency noise preserving reconstruction filter (i.e., standard), 40% ASiR Trade-Mark-Sign was implemented in our clinic for 42%-48% dose reduction at all pediatric ages without a visually perceptible change in image quality or image noise.

60 APPLIED LIFE SCIENCES↗