Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Gaining the most utility from our geospace observational system: Network analysis of total electron content as a means to understand space weather to the point of prediction

We present the first network analysis of interplanetary magnetic field (IMF) clock angle dependent, high-latitude, hemispheric-specific total electron content (TEC) data. We examine network parameters to describe spatio-temporal correlations in the TEC data for January 2016. We find that significant network structure exists distinguishing the dayside and nightside ionosphere, and specific features in the high-latitudes (cusp/ionospheric footpoints of magnetospheric boundary layers, polar cap, and auroral zone), and that these features vary with IMF clock angle. In this brief summary paper, we provide proof of concept results and identify important areas of future research, providing a basis for the discussion of network analysis and machine learning approaches for space weather applications.

Malik, Nishant↗

Linear Systems LSK389 and LSK489 Dual N-Channel JFET Amplifier Total Ionizing Dose and Single-Event Effects Test Report

The purpose of these tests was to characterize the susceptibility of the LSK389 and LSK489 Dual N-Channel JFET from Linear Systems to Single-Event Latchup due to heavy ions and to Total Ionizing Dose (TID) degradation at -65 °C and intermediate dose rate. The test was carried out to assess suitability of the amplifiers for the Ocean Color instrument (OCI) on the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft.

Ray Ladbury↗

Using Networked Pandora Observations to Capture Spatiotemporal Changes in Total Column Ozone Associated with Stratosphere-to-Troposphere Transport

Accurately capturing the evolution of episodic stratosphere-to-troposphere transport is critical due to the potential impacts on both climate and air quality. Until now, investigating associated spatiotemporal gradients in total column ozone (TCO) has primarily been the task of observations from polar-orbiting satellites as well as high-resolution models. We explore how a network of five ground-based Pandora spectrometer systems can be utilized in a similar fashion. The passage of a strong mid-latitude cyclone in March 2018 and its associated stratospheric intrusion is used as a case demonstrating the ability of networked Pandora observations to contextualize these regions of transport across space and time. Results show that the high temporal resolution of Pandora observations and the networked approach were able to resolve increases in TCO associated with stratosphere-to-troposphere transport and to capture the spatial context of the chosen episode. The use of networked Pandora observations shows promise for additional transport studies and for supporting future geostationary atmospheric composition satellite missions and modeling efforts.

J. Robinson↗

A Post-2013 Dropoff in Total Ozone at a Third of Global Ozonesonde Stations: Electrochemical Concentration Cell Instrument Artifacts?

An international effort to improve ozonesonde data quality and to reevaluate historical recordshas made significant improvements in the accuracy of global network data. However, between 2014 and2016, ozonesonde total column ozone (TCO; O3) at 14 of 37 regularly reporting stations exhibited a suddendropoff relative to satellite measurements. The ozonesonde TCO drop is 3–7% compared to satellite andground‐based TCO, and 5–10% or more compared to satellite stratospheric O3profiles, compromising theuse of recent data for trends, although they remain reliable for other uses. Hardware changes in theozonesonde instrument are likely a major factor in the O3dropoff, but no single property of the ozonesondeexplains thefindings. The bias remains in recent data. Research to understand the dropoff is in progress; thisletter is intended as a caution to users of the data. Ourfindings underscore the importance of regularozonesonde data evaluation.

ozonesonde TCO drop↗

Total Ionizing Dose Testing of the Analog Devices’ AD648 Dual Precision Operational Amplifier

The Analog Devices (ADI) AD648 was tested for total ionizing dose response at the Goddard Space Flight Center (GSFC) Radiation Effects Facility (REF) beginning 1 June 2011. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Alvin J Boutte↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15µm to 460 µm. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

Icing cloud instruments↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15m to 460 m. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15um to 460 um. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Two Air Quality Regimes in Total Column NO2 over the Gulf of Mexico in May 2019: Shipboard and Satellite Views

The Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf of Mexico was conducted in May 2019 by NASA and the Bureau of Ocean Energy Management to determine the feasibility of using satellite data to measure air quality in a region of concentrated oil and natural gas (ONG) operations. SCOAPE addressed both technological and scientific issues related to measuring NO2 columns over the Outer Continental Shelf. Featured were nitrogen dioxide (NO 2 ) instruments (Pandora, Teledyne API analyzer) at Cocodrie, LA (29.26°, -90.66°), and on the Research Vessel Point Sur operating off the Louisiana coast with measurements of ozone, carbon monoxide and volatile organic compounds (VOC). The findings: (1) All NO 2 observations revealed two atmospheric regimes over the Gulf, the first influenced by tropical air in 10-14 May, the second influenced by flow from urban areas on 15-17 May; (2) Comparisons of OMI v4 and TROPOMI v1.3 TC (total column) NO 2 data with shipboard Pandora NO 2 column observations averaged 13% agreement with the largest difference during 15-17 May (~20%). At Cocodrie, the satellite-Pandora agreement was ~5%. (3) Three new-model Pandora instruments displayed a TC NO 2 precision of 0.01 Dobson Units (~5%); (4) Regions of smaller, older natural gas operations showed high methane readings from leakage; elevated VOC were also detected. Neither satellite nor spectrometer captured the magnitude of ambient NO 2 variability near ONG platforms. Given an absence of regular air quality monitoring over the Gulf of Mexico, SCOAPE data constitute a baseline against which future observations can be compared.

Nitrogen dioxide↗

PE99155 Point-Of-Load Buck Regulator Total Ionizing Dose Test Report

Teledyne’s PE99155 point-of-load buck regulator was tested to evaluate an applicationspecific question about the start-up behavior of the device. This test determined if accumulated total ionizing dose (TID) affected any start-up voltage transient characteristics. Testing was based on pass/fail criterial for the magnitude of the output voltage to ensure the safety of downstream electronics. Two sets of radiation tests were performed. The first group of PE99155s used a high dose rate (HDR) irradiation to 25 krad(Si). A second group of PE99155s used high dose rate irradiation to 30 krad(Si).

TID↗

C30665L CD3740 Displacement Damage and Total Ionizing Dose Test Report

The purpose of this testing is to provide preliminary characterization of the displacement damage and total ionizing dose effects via 63 MeV protons on InGaAs PIN photodiodes fabricated and assembled by Excelitas for use in a LIDAR system. The testing is being conducted to determine the susceptibility of the component to the radiation environment that it will be exposed to during mission duration.

Landen D Ryder↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗

Estimating the concentration of total suspended solids in inland and coastal waters from Sentinel-2 MSI: A semi-analytical approach

Inland and coastal waters provide key ecosystem services and are closely linked to human well-being. In this study, we propose a semi-analytical method, which can be applied to Sentinel-2 MultiSpectral Instrument (MSI) images to retrieve high spatial-resolution total suspended solids (TSS) concentration in a broad spectrum of aquatic ecosystems ranging from clear to extremely turbid waters. The presented approach has four main steps. First, the remote sensing reflectance ( R rs ) at a band lacking in MSI (620 nm) is estimated through an empirical relationship from R rs at 665 nm. Second, waters are classified into four types (clear, moderately turbid, highly turbid, and extremely turbid). Third, semi-analytical algorithms are used to estimate the particulate backscattering coefficient ( b bp ) at a reference band depending on the water types. Last, TSS is estimated from bbp at the reference band. Validation and comparison of the proposed method with three existing methods are performed using a simulated dataset ( N = 1000), an in situ dataset collected from global inland and coastal waters ( N = 1265) and satellite matchups ( N = 40). Results indicate that the proposed method can improve TSS estimation and provide accurate retrievals of TSS from all three datasets, with a median absolute percentage error (MAPE) of 14.88 %, 31.50 % and 41.69 % respectively. We also present comparisons of TSS mapping between the Sentinel-3 Ocean and Land Colour Instrument (OLCI) and MSI in Lake Kasumigaura, Japan and the Tagus Estuary, Portugal. Results clearly demonstrate the advantages of using MSI for TSS monitoring in small water bodies such as rivers, river mouths and other nearshore waters. MSI can provide more detailed and realistic TSS estimates than OLCI in these water bodies. The proposed TSS estimation method was applied to MSI images to produce TSS time-series in Lake Kasumigaura, which showed good agreements with in situ and OLCI-derived TSS time-series.

Sentinel-2↗

Total Ionizing Dose Test Report Microchip JANTXV2N6284 NPN Darlington Power Si Transistor

This study was undertaken to determine the effects of total ionizing dose (TID) on the JANTXV2N6284 NPN Darlington power bipolar junction transistor (BJT). The device was parametrically characterized prior to, at each incremental dose step, and after irradiation. Testing was at a low-dose rate using the NASA GSFC Radiation Effects Facility (REF).

Kaitlyn L Ryder↗