Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TiP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Rapid simulations of hyperspectral near-field images of three-dimensional heterogeneous surfaces – part II

The modeling of the near-field interaction in the scattering-type scanning near-field optical microscope (s-SNOM) is rapidly advancing, although an accurate yet versatile modeling framework that can be easily adapted to various complex situations is still lacking. In this work, we propose a time-efficient numerical scheme in the quasi-electrostatic limit to capture the tip-sample interaction in the near field. This method considers an extended tip geometry, which is a significant advantage compared to the previously reported method based on the point-dipole approximation. Using this formalism, we investigate, among others, nontrivial questions such as uniaxial and biaxial anisotropy in the near-field interaction, the relationship between various experimental parameters (e.g. tip radius, tapping amplitude, etc.), and the tip-dependent spatial resolution. The demonstrated method further sheds light on the understanding of the contrast mechanism in s-SNOM imaging and spectroscopy, while also representing a valuable platform for future quantitative analysis of the experimental observations.

Chen, Xinzhong (ORCID:0000000261033848)↗

Technology Demonstration of a High-Pressure Swirl Oxy-Coal Combustor

This technical report presents the exploration of the design and prototyping of a High-Pressure Swirl Oxy-coal Combustor. Pressurized oxy-coal combustion systems have the potential to improve efficiency along with an increased carbon capture rate. Reduction of flue gas at higher pressure, smaller system size, and capital cost reductions render high-pressure oxy-coal systems particularly attractive as next-generation energy-producing systems. High-pressure oxy-coal combustion systems are a recent concept, and thus operability issues of combustor designs for such systems are not fully understood. Significant challenges exist to maintain oxy-coal combustion stability at elevated pressure and a high CO 2 diluent environment. Although a body of knowledge exists for high-pressure oxygen combustion in rocket engines (or similar applications), it is yet to be strategized how these fundamental concepts can be translated to low-temperature CO 2 diluent combustion regimes. The realization of the pressurized oxy-coal based systems requires combustor components to be designed and demonstrated for an operating pressure over 10 bar. However, pressurized oxy-coal combustor design information at this pressure range and scale relevant to validate those proposed systems is currently limited. Experimental data from MWth scale oxy-coal combustors are needed to identify the optimal trade-off between net efficiency and systems size. The proposed effort is aimed at demonstrating a 1 MWth down-fired swirl Oxy-Coal combustor and investigate the interrelation between combustor operating conditions (pressure; flame stability; flue gas recirculation ratio) and conversion efficiencies to minimize oxygen requirements. One of the key challenges is to configure burner design (i.e., swirl number and injector) and operating conditions for high-pressure oxy-coal combustion systems. These experiments differ from current systems partly due to the high theoretical flame temperature and related burner operability issues associated with oxy-combustion. An ASPEN PLUS® model study for 550 MWe TIPS and ENEL pressurized oxy-coal systems with CO 2 recirculation was performed to evaluate system design, subsystems sizing, and operating condition determination. The system analysis effort included TRL and technology gap determination of subsystems and critical components. This information was scaled to develop design requirements (design pressure and flue gas recirculation: RR Flue Gas = $\frac{m_{flue}}{m_{total}}$) for the 1 MWth combustor. The effects of a wide range of carbon dioxide recirculation ratios on the thermal efficiency of ENEL and TIPS cycles are studied. The pressure of 10 bar and 80 bar are used for ENEL and TIPS cycles, respectively. The thermal efficiency of ENEL is significantly higher than the efficiency of TIPS at a pressure of less than 10 bar. The insights from system analysis were then used to design a 1 MWth swirl oxy-coal combustor. Flame temperature analysis and material strength analysis was performed to determine the combustor thickness. The structural integrity of the combustor was validated by finite element analysis using Abacus® and Hypermesh®. Feasibility of igniters and secondary burners are investigated in successful high-pressure oxy-methane combustion. The secondary burners are designed in such a way that it can operate between 100 to 500 kW firing input. Three generations of the pintle injector were designed based on swirl numbers (S=0, 0.9, and 1.2). Key pintle injector parameters such as pintle size, pintle orifice size, spray pattern were investigated by cold flow tests. Information from these tests was used to modify injector design for smooth and successful operation. A 5 mm pintle orifice size was decided upon as the optimum size for oxy-coal operation for the combustor. Shadow sizing experiments were performed to identify the atomization rate of each injector. Different coal water slurry mixtures (30 – 50% coal by wt% in the mixture) at various total momentum ratios (TMR) were investigated for this purpose. These experiments provided decisive information to choose the best design of the injector. The injector with 1.2 swirl provided higher atomization in all cases than other designs. The mean equivalent droplet size of the jet was similar at different TMR and mixture ratios using this injector, thus making it suitable for use in most cases. Therefore, the 1.2 swirl-pintle injector was chosen for the shakedown test. The combustor and other sub-systems, including feed systems and control and data acquisition, have been manufactured, assembled, and integrated. The total system integration and installation began on July 1, 2020. The shake-down tests and initial operational capability demonstration are expected to be completed by September 30, 2020.

01 COAL, LIGNITE, AND PEAT↗

Characterizing Hydraulic Fracture Propagation Before Fracture Hits

Estimating the distance from hydraulic fracture tip to monitor well can be very useful for fracture characterization, well spacing optimization, and preventing parent-child well interference. Heart-shape signal is referred to as the extensional precursor of fracture hit recorded by cross-well strain measurements and can be served as a vital tool to make such estimation. This study incorporates the 3D Displacement Discontinuity Method to understand the impact of fracture geometry and monitor well offset on the heart-shape signal’s characteristics. Results from numerical simulation and analytical solutions reveal a strong linear correlation between the spatial extent of heart shape signal and fracture tip distance. This relationship was further developed to predict tip distance using field data from the Hydraulic Fracture Test Site 2. A reasonable approximation result from field data further validates the methodology. In addition, it is worth noting that the estimation accuracy depends on the ratio between fracture dimension and tip distance. The findings of this study offer a novel approach for real-time monitoring and characterizing hydraulic fracture propagation, which can be further used for well spacing optimization in unconventional and Enhanced Geothermal System reservoir development, as well as cap rock integrity monitoring for carbon sequestration projects.

Jin, Ge↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence V - Raw Data

Sequence V: Tip Plate (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s, and the yaw angle was held at 0°. The blade pitch angle was 3°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. The standard tip blocks were replaced with a tip plate to simulate the effect of an undeployed tip-mounted aerodynamic brake as shown in Appendix A. Note that the blade radius was not changed during post-processing so the pressure tap locations are at the same radial location, but the reference to 30% represents 30% of 5.029 m, not 4.943 m. Throughout this report, references to the blade span are made for the 5.029- m radius, not the 4.943-m radius.

17 WIND ENERGY↗

Study of blade clearance effects on centrifugal pumps

A program of analysis, design, fabrication, and testing has been conducted to develop and experimentally verify analytical models to predict the effects of impeller blade clearance on centrifugal pumps. The effect of tip clearance on pump efficiency, and the relationship between the head coefficient and torque loss with tip clearance was established. Analysis were performed to determine the cost variation in design, manufacture, and test that would occur between unshrouded and shrouded impellers. An impeller, representative of typical rocket engine impellers, was modified by removing its front shroud to permit variation of its blade clearances. It was tested in water with special instrumentation to provide measurements of blade surface pressures during operation. Pump performance data were obtained from tests at various impeller tip clearances. Blade pressure data were obtained at the nominal tip clearance. Comparisons of predicted and measured data are given.

Hoshide, R. K.↗

Wind tunnel simulation of full scale vortices

An experimental investigation has been conducted to determine the important scaling parameters for the flow in the core region of a vortex generated by a rectangular wing tip. The effect of an unconventional planform, the ogee tip, on the tip vortex is also determined. For rectangular planform wings, the measured vortex core diameter to chord ratios, peak tangential velocity ratios, and axial velocity ratios are shown to be functions only of wing lift coefficient and elapsed time from vortex formation, and appear to be independent of both Mach number and Reynolds number. The peak tangential velocities in the diffuse vortex generated by the ogee tip are only 25 percent of those in the vortex generated by the rectangular wing.

Rorke, J. B.↗

Unsteady Subsonic and Transonic Potential Flow over Helicopter Rotor Blades

Differential equations and boundary conditions for a rotor blade in forward flight, with subsonic or transonic tip Mach number, are derived. A variety of limiting flow regimes determined by different limits involving blade thickness ratio, aspect ratio, advance ratio and maximum tip Mach number is discussed. The transonic problem is discussed in some detail, and in particular the conditions that make this problem quasi-steady or essentially unsteady are determined. Asymptotic forms of equations and boundary conditions that are valid in an appropriately scaled region of the tip and an azimuthal sector on the advancing side are derived. The equations are then put in a form that is valid from the blade tip inboard through the strip theory region.

Isom, M. P.↗

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations. Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

Analytical displacements and vibrations of cantilevered unsymmetric fiber composite laminates

A fiber composite flat cantilever plate that has symmetric and nonsymmetric laminate configurations is theoretically investigated to determine its static and dynamic structural response. The finite element analysis method used includes a unique triangular finite element developed at Lewis for the analysis of fiber composite airfoils. The various responses investigated include tip displacements, natural frequencies, and fundamental mode shapes. The results show that laminate configurations may be selected for a cantilever such that when the tip at the leading edge is loaded normal to the plane of the plate, the tip at the trailing edge can (1) deflect in the opposite direction, (2) deflect about the same, or (3) deflect more than the tip at the leading edge. This variation in response can be utilized to provide built-in structural damping to resist flutter.

Minich, M. D.↗

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading were subjected to screen induced circumferential distortions of 90 degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations. Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

An Experimental Study of the Nonlinear Stiffness of a Rotor Blade Undergoing Flap, Lag and Twist Deformations

The large deformation of a cantilevered beam under a gravity tip load was studied. The beam root is rotated so that the tip load is oriented at various angles with respect to the beam principal axes. Static twist and bending deflections of the tip and bending natural frequencies were measured as a function of tip load magnitude and orientation. The experimental data are compared with the results of a recently developed nonlinear structural theory and agreement is good for deflections that are small compared to the beam span with systematic deviations for larger deflections. These results support the validity and utility of the nonlinear structural theory for rotor blade applications.

Dowell, E. H.↗

Effect of slotted casing treatment with change in Reynolds number index on performance of a jet engine

A tip-treated J85-13 engine was tested at Reynolds number indices (RNI) of 0.3 and 0.7 with a clean inlet for 80- and 100-percent corrected engine speeds. This engine was equipped with a compressor case which allowed changes to the case wall over the rotor tips of six of its eight stages. For all tests, the principal effects were (1) with tip treatment, a stall pressure ratio loss of 6 percent at 100 percent corrected engine speeds for both the 0.3 and 0.7 RNI, and (2) with and without tip treatment, decreasing the RNI from 0.7 to 0.3 decreased the stall pressure ratio 3.8 percent for 100 percent corrected engine speed and 2.8 percent for 80-percent corrected engine speed.

Moss, J. E., Jr.↗

An experimental-theoretical correlation study of non-linear bending and torsion deformations of a cantilever beam

An experimental study of the large deformation of a cantilevered beam under a gravity tip load has been made. The beam root is rotated so that the tip load is oriented at various angles with respect to the beam principal axes. Static twist and bending deflections of the tip and bending natural frequencies have been measured as a function of tip load magnitude and orientation. The experimental data are compared with the results of a recently developed non-linear structural theory. Agreement is reasonably good when bending deflections are small compared to the beam span, but systematic differences occur for larger deflections.

Dowell, E. H.↗

Comparison of the noise characteristics of two low pressure ratio fans with a high throat Mach number inlet

Acoustics data obtained in experiments with two low pressure ratio 50.8 cm (20 in.) diameter model fans differing in design tip speed were compared. Determination of the average throat Mach number used to compare high Mach inlet noise reduction characteristics was based on a correlation of inlet wall static pressure measurements with a flow field calculation. The largest noise reductions were generally obtained with the higher tip speed fan. At a throat Mach number of 0.79, the difference in noise reduction was about 3.5 db with static test conditions. Although the noise reduction increased for the lower tip speed fan with a simulated flight velocity of 41 m/sec (80 knots), it was still about 2 db less than that of the high tip speed fan which was only tested at the static condition. However, variations in acoustic performance could not be absolutely attributed to the different fan designs because of differences in inlet lip contours which resulted in small variations of peak wall Mach number and axial extend of supersonic and near-sonic flow.

Wesoky, H. L.↗

A study of the noise radiation from four helicopter rotor blades

Acoustic measurements were taken of a modern helicopter rotor with four blade tip shapes in the NASA Ames 40-by-80-Foot Wind Tunnel. The four tip shapes are: rectangular, swept, trapezoidal, and swept tapered in platform. Acoustic effects due to tip shape changes were studied based on the dBA level, peak noise pressure, and subjective rating. The swept tapered blade was found to be the quietest above an advancing tip Mach number of about 0.9, and the swept blade was the quietest at low speed. The measured high speed impulsive noise was compared with theoretical predictions based on thickness effects; good agreement was found.

Lee, A.↗

Apparatus and method of inserting a microelectrode in body tissue or the like using vibration means

An arrangement for and method of inserting a glass microelectrode having a tip in the micron range into body tissue is presented. The arrangement includes a microelectrode. The top of the microelectrode is attached to the diaphragm center of a first speaker. The microelectrode tip is brought into contact with the tissue by controlling a micromanipulator. Thereafter, an audio signal is applied to the speaker to cause the microelectrode to vibrate and thereby pierce the tissue surface without breaking the microelectrode tip. Thereafter, the tip is inserted into the tissue to the desired depth by operating the micromanipulator with the microelectrode in a vibratory or non-vibratory state.

Feldstein, C.↗

Shock isolator for operating a diode laser on a closed-cycle refrigerator

A diode laser mounted within a helium refrigerator is mounted using a braided copper ground strap which provides good impact shock isolation from the refrigerator cold-tip while also providing a good thermal link to the cold-tip. The diode mount also contains a rigid stand-off assembly consisting of alternate sections of nylon and copper which serve as cold stations to improve thermal isolation from the vaccum housing mounting structure. Included in the mount is a Pb-In alloy wafer inserted between the cold-tip and the diode to damp temperature fluctuations occurring at the cold-tip.

Jennings, D. E.↗

IMP 8. Volume 1: EM field experiment

The electromagnetic fields experiment on IMP-J used two electric dipole antennas and a triaxial search coil magnetic antenna to sense the electric and magnetic field of plasma waves in space. The electric dipole antennas consisted of a fine wire, 0.021 inches in diameter, with a nominal extended tip-to-tip length of 400 ft. The outermost 50 ft. of each element was conducting and the rest of the antenna was covered with an insulating coating. The search coil antennas each consisted of a high mu core with two separate windings of 40,000 turns each to sense ac magnetic fields. The search coils had a length of 18 inches tip-to-tip and are mounted on the end of a boom. The axes of the x prime and y prime search coil antennas were parallel to the x prime and y prime electric antenna axes.

Source record↗