Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Quantifying Solar PV Variability at Multiple Timescales for Power Systems Studies: Preprint

Increasing penetration of solar photovoltaics (PV) has concerned power system operators about their ability to balance load and generation over multiple timescales and maintain acceptable frequency profile because of the variability and uncertainty associated with solar PV. This paper focuses on developing metrics to quantify solar PV variability at multiple temporal scales ranging from seconds to an hour to help power system operators and planners better understand and account for solar PV variability under high solar PV penetration. Fourier coefficients of solar irradiation spectrum and average size of solar irradiation ramps over a day are the two metrics that are used to quantity the variability. It is shown that by using the two metrics the days with highest and lowest solar irradiation variability can be identified, which is useful information for operations planning or long-term power system planning studies. The key findings of the paper are (i) single sensor-based variability quantification can significantly exaggerate the variability of a solar PV plant, particularly at seconds to 1-min temporal resolution, (ii) at 1-minute or lower temporal resolutions, single sensor-based variability quantification of an entire plant can be fairly accurate, with the accuracy increasing as the temporal resolution reduces from 1-minute to 1-hour, (iii) at each 1-minute and lower temporal resolutions, maximum solar irradiation ramps appear to be independent of the geographical location of the sensor, and (iv) significant reduction in solar PV plant variability over a region with multiple plants is possible at all temporal scales, but more high quality, high temporal resolution data is needed to quantify the reduction with high confidence.

photovoltaics↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management platform↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

A Review on Artificial Intelligence for Grid Stability Assessment

Artificial intelligence provides a convenient route for power grid stability assessment. Compared with simulation-based approaches, artificial intelligence can potentially save time on model development and numerical computation in stability assessment. This paper first reviewed existing literature on using artificial intelligence for power grid stability assessment. Then a machine-leaning-based tool is presented and developed to assess power grid transient stability, frequency stability, and small signals stability. Test results verified the accuracy and effectiveness of the AI tool for power grid stability assessment.

You, Shutang↗

A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System

Here, this paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement-and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method-Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18-20 Hz oscillation event in Kaua‘i's power system on November 21, 2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In Situ Transmission Electron Microscopy Study of Conductive Filament Formation in Copper Oxides

The structural and electrical property changes of two types of copper oxides (CuO and Cu 2 O) under voltage bias are studied with in situ transmission electron microscopy (TEM). The phases of different materials are confirmed with electron diffraction. In both types of oxides, dynamic conductive path formation and dissolution are observed. The decrease in resistance of CuO film is found to be accompanied with the formation of Cu 4 O 3 phase where the electric field strength is highest. We also find that the decrease in resistivity of Cu 2 O film is more extensive and occurs in an area depending on the level of current compliance. In conclusion, the physical mechanisms responsible for the observations and their implications for the formation of conducting regions in copper oxide-based memristors are discussed.

36 MATERIALS SCIENCE↗

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ARENA: Asynchronous Reconfigurable Accelerator Ring to Enable Data-Centric Parallel Computing

The next generation HPC and data centers are likely to be reconfigurable and data-centric due to the trend of hardware specialization and the emergence of data-driven applications. In this work, we propose ARENA – an asynchronous reconfigurable accelerator ring architecture as a potential scenario on how the future HPC and data centers will be like. Despite using the coarse-grained reconfigurable arrays (CGRAs) as the substrate platform, our key contribution is not only the CGRA-cluster design itself, but also the ensemble of a new architecture and programming model that enables asynchronous tasking across a cluster of reconfigurable nodes, so as to bring specialized computation to the data rather than the reverse. We presume distributed data storage without asserting any prior knowledge on the data distribution. Hardware specialization occurs at runtime when a task finds the majority of data it requires are available at the present node. In other words, we dynamically generate specialized CGRA accelerators where the data reside. The asynchronous tasking for bringing computation to data is achieved by circulating the task token, which describes the dataflow graphs to be executed for a task, among the CGRA cluster connected by a fast ring network. Evaluations on a set of HPC and data-driven applications across different domains show that ARENA can provide better parallel scalability with reduced data movement (53.9 percent). Compared with contemporary compute-centric parallel models, ARENA can bring on average 4.37× speedup. The synthesized CGRAs and their task-dispatchers only occupy 2.93mm 2 chip area under 45nm process technology and can run at 800MHz with on average 759.8mW power consumption. ARENA also supports the concurrent execution of multi-applications, offering ideal architectural support for future high-performance parallel computing and data analytics systems.

97 MATHEMATICS AND COMPUTING↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A General Decentralized Dynamic State Estimation With Synchronous Generator Magnetic Saturation

We report the saturation of the nonlinear magnetic circuit of synchronous generators is often neglected when performing Kalman filter-based dynamic state estimation (DSE), yielding significant estimation bias. This letter addresses this problem and proposes a generalized DSE framework to handle magnetic saturation. Moreover, this letter derives a state initialization procedure that improves the Kalman filter tracking speed. The framework is flexible in dealing with different saturation functions and generator models. Numerical results on the Texas 2000-bus system verify the effectiveness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ambient-Frequency-Data Based System-Level Inertia Estimation Using Physical Equation and its Practice on Hawaii Islands

Here, in this paper, a practical ambient-frequency-data-based inertia estimation method using a physical equation is proposed and validated by real measurement data from Hawaii island grids. With high renewable penetration, accurate inertia estimation is important and urgent. Ambient frequency oscillation always exists in power grids, so the proposed method has advantages of real-time inertia estimation and no need for additional disturbances. This paper first developed the physical equation for inertia estimation to offer a clear mechanism for easy implementation in practice. To apply the proposed method in actual grids, a practical method to extract the ambient frequency oscillation from frequency measurement is further proposed. The inertia estimation using the physical equation is validated by KIUC simulation data and HECO field data, in which error rates are around 2% and 8%, respectively. Practical inertia estimation is challenging due to the large amounts of resources contributing to the power grid's effective inertia, but the method provided in this paper can offer a novel way for practical inertia estimation, which can help renewable penetration to boost carbon-free grid.

14 SOLAR ENERGY↗