Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Statistical Modeling of the Eye for Multimodal Treatment Planning for External Beam Radiation Therapy of Intraocular Tumors

Purpose: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. Methods and Materials: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. Results: Cross-validation revealed a dice similarity of 95% {+-} 2% for the sclera and cornea and 91% {+-} 2% for the lens. Overall, mean segmentation error was found to be 0.3 {+-} 0.1 mm. Average segmentation time was 14 {+-} 2 s on a standard personal computer. Conclusions: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Assessment of the Current US Radiation Oncology Workforce: Methodology and Global Results of the American Society for Radiation Oncology 2012 Workforce Study

Purpose: To determine the characteristics, needs, and concerns of the current radiation oncology workforce, evaluate best practices and opportunities for improving quality and safety, and assess what we can predict about the future workforce. Methods and Materials: An online survey was distributed to 35,204 respondents from all segments of the radiation oncology workforce, including radiation oncologists, residents, medical dosimetrists, radiation therapists, medical physicists, nurse practitioners, nurses, physician assistants, and practice managers/administrators. The survey was disseminated by the American Society for Radiation Oncology (ASTRO) together with specialty societies representing other workforce segments. An overview of the methods and global results is presented in this paper. Results: A total of 6765 completed surveys were received, a response rate of 19%, and the final analysis included 5257 respondents. Three-quarters of the radiation oncologists, residents, and physicists who responded were male, in contrast to the other segments in which two-thirds or more were female. The majority of respondents (58%) indicated they were hospital-based, whereas 40% practiced in a free-standing/satellite clinic and 2% in another setting. Among the practices represented in the survey, 21.5% were academic, 25.2% were hospital, and 53.3% were private. A perceived oversupply of professionals relative to demand was reported by the physicist, dosimetrist, and radiation therapist segments. An undersupply was perceived by physician's assistants, nurse practitioners, and nurses. The supply of radiation oncologists and residents was considered balanced. Conclusions: This survey was unique as it attempted to comprehensively assess the radiation oncology workforce by directly surveying each segment. The results suggest there is potential to improve the diversity of the workforce and optimize the supply of the workforce segments. The survey also provides a benchmark for future studies, as many changes in the healthcare field exert pressure on the workforce.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fabrication and temperature-dependent magnetic properties of one-dimensional multilayer Au–Ni–Au–Ni–Au nanowires

Multilayer Au–Ni–Au–Ni–Au nanowires with a controlled diameter of ∼100 nm were synthesized by electrochemical deposition in porous alumina templates. The length of each Ni-segment was controlled up to ∼230 nm, while the length of the Au segment sandwiched between two Ni segments was ∼180 nm. X-ray diffraction patterns and energy-dispersive X-ray spectra confirmed the formation of purely crystalline nanowires. The magnetic properties of the multilayer Au–Ni–Au–Ni–Au nanowires were investigated in the temperature range 2–300 K. Room-temperature magnetic hysteresis confirmed the ferromagnetic nature of the nanowires. The plot of coercivity as a function of temperature (from 2 to 300 K) followed law applicable for ferromagnetic nanostructures. The magnetization tended to increase as the temperature decreased, following the modified Bloch's law similar to ferromagnetic nanoparticles. - Graphical abstract: (a) SEM image of Au–Ni–Au–Ni–Au nanowire with 230 nm Ni segment length and 180 nm Au sandwiched between Ni segments (b) Kneller's law (c) Bloch's law Display Omitted - Highlights: • Electrochemical fabrication of Au–Ni–Au–Ni–Au nanowires in alumina templates. • Formation of beadlike structure of Ni segments. • Coercivity versus T follows Kneller's law for ferromagnetic materials. • Magnetization as a function of temperature follows the modified Bloch's law.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Vivo Diode Dosimetry for Imrt Treatments Generated by Pinnacle Treatment Planning System

Dose verification using diodes has been proposed and used for intensity modulated radiation therapy (IMRT) treatments. We have previously evaluated diode response for IMRT deliveries planned with the Eclipse/Helios treatment planning system. The Pinnacle treatment planning system generates plans that are delivered in a different fashion than Eclipse. Whereas the Eclipse-generated segments are delivered in organized progression from one side of each field to the other, Pinnacle-generated segments are delivered in a much more randomized fashion to different areas within the field. This makes diode measurements at a point more challenging because the diode may be exposed fully or partially to multiple small segments during one single field's treatment as opposed to being exposed to very few segments scanning across the diode during an Eclipse-generated delivery. We have evaluated in vivo dosimetry for Pinnacle-generated IMRT plans and characterized the response of the diode to various size segments on phantom. We present results of patient measurements on approximately 300 fields, which show that 76% of measurements agree to within 10% of the treatment-plan generated calculated doses. Of the other 24%, about 11% are within 15% of the calculated dose. Comparison of these with phantom measurements indicates that many of the discrepancies are due to diode positioning on patients and increased diode response at short source-to-surface distances (SSDs), with the remainder attributable to other factors such as segment size and partial irradiation of the diode.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal field-splitting algorithm in intensity-modulated radiotherapy: Evaluations using head-and-neck and female pelvic IMRT cases

To develop an optimal field-splitting algorithm of minimal complexity and verify the algorithm using head-and-neck (H and N) and female pelvic intensity-modulated radiotherapy (IMRT) cases. An optimal field-splitting algorithm was developed in which a large intensity map (IM) was split into multiple sub-IMs (≥2). The algorithm reduced the total complexity by minimizing the monitor units (MU) delivered and segment number of each sub-IM. The algorithm was verified through comparison studies with the algorithm as used in a commercial treatment planning system. Seven IMRT, H and N, and female pelvic cancer cases (54 IMs) were analyzed by MU, segment numbers, and dose distributions. The optimal field-splitting algorithm was found to reduce both total MU and the total number of segments. We found on average a 7.9 ± 11.8% and 9.6 ± 18.2% reduction in MU and segment numbers for H and N IMRT cases with an 11.9 ± 17.4% and 11.1 ± 13.7% reduction for female pelvic cases. The overall percent (absolute) reduction in the numbers of MU and segments were found to be on average −9.7 ± 14.6% (−15 ± 25 MU) and −10.3 ± 16.3% (−3 ± 5), respectively. In addition, all dose distributions from the optimal field-splitting method showed improved dose distributions. The optimal field-splitting algorithm shows considerable improvements in both total MU and total segment number. The algorithm is expected to be beneficial for the radiotherapy treatment of large-field IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Leveraging Sequential Doping of Semiconducting Polymers to Enable Functionally Graded Materials for Organic Thermoelectrics

With the ability to modulate electronic properties through molecular doping coupled with ease in processability, semiconducting polymers are at the forefront in enabling organic thermoelectric devices for thermal energy management. In contrast to uniform thermoelectric material properties, an alternative route focuses on functionally graded materials (FGMs) where one spatially controls and optimizes transport properties across the length of a thermoelectric material. While primarily studied in the context of inorganic materials, the concept of FGMs for organic thermoelectrics has not been explored. Herein, we introduce how molecular doping of semiconducting polymers enables spatial compositional control of thin-film FGMs. Specifically, we utilize sequential vapor doping of poly[2,5-bis(3-tetradecylthiophen-2-yl) thieno [3,2-b]thiophene] (PBTTT) with the small molecule acceptor 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ) to fabricate the simplest form of FGMs – double- segmented thin films. The two thin-film segments are of equal length (7.5 mm), but each set to different doping levels. Our study focuses on understanding the thermoelectric properties (Seebeck coefficient, α, and electronic conductivity, σ) and structural properties (through X-ray scattering, UV-vis-NIR spectroscopy, and Raman spectroscopy) within and across the two segments. We observe the presence of a small diffuse interfacial region of 0.5 – 1 mm between the two segments where the doping level and transport properties vary continuously. Despite the diffuse interface, the measured effective Seebeck coefficient (αeff) across the two segments is simply the average of α within each segment. Importantly, this experimental result is consistent with reported mathematical models describing αeff in graded thermoelectric materials. Finally, our results demonstrate the facile fabrication and characterization of functionally graded organic thermoelectric materials, providing guidelines for further development on more complex FGMs.

36 MATERIALS SCIENCE↗

Tuning the Double Gyroid Phase Window in Block Copolymers via Polymer Chain Conformation Near the Interface

Block copolymer network morphologies have been proven interesting for applications ranging from mechanical to transport and optical properties. The shape of the polymer chain and its ability to stretch across an interface can be used as handles to target these network morphologies. Here, we show that the double gyroid phase window is broadened when there is a flexible segment near the interface and narrowed when a more constrained segment is placed there by using a series of poly(styrene-b-peptoid) block copolymers in which the polypeptoid block chain conformation can be tuned to adopt either a helical or a coil conformation (NRpe 6 vs Npe 6 ). The double gyroid phase is accessed in both block copolymer series, while the phase boundaries are shifted toward larger polypeptoid volume fractions in the helix-forming PS–(NRpe 6 Nmey) series, due to the more compact helix segment (i.e., the helix segment has the same chain volume as its random coil counterpart but occupies less space). The space-filling difference between the helix and coil segment is further confirmed by the smaller domain spacing of PS–(NRpe 6 Nme 39 ) compared to PS–(Npe 6 Nme 36 ) (13.9 nm vs 14.3 nm) despite the former having a longer polypeptoid block. Furthermore, a broadened double gyroid phase window is accessed in the PS–(Npe 6 Nme y ) series that has a flexible coil segment near the interface. These results demonstrate the possibility of tuning the double gyroid phase in linear block copolymers by chain conformation near the interface alone, highlighting chain conformation as a versatile handle in block copolymer design.

36 MATERIALS SCIENCE↗

Statistical optimisation techniques in fatigue signal editing problem

Success in fatigue signal editing is determined by the level of length reduction without compromising statistical constraints. A great reduction rate can be achieved by removing small amplitude cycles from the recorded signal. The long recorded signal sometimes renders the cycle-to-cycle editing process daunting. This has encouraged researchers to focus on the segment-based approach. This paper discusses joint application of the Running Damage Extraction (RDE) technique and single constrained Genetic Algorithm (GA) in fatigue signal editing optimisation.. In the first section, the RDE technique is used to restructure and summarise the fatigue strain. This technique combines the overlapping window and fatigue strain-life models. It is designed to identify and isolate the fatigue events that exist in the variable amplitude strain data into different segments whereby the retention of statistical parameters and the vibration energy are considered. In the second section, the fatigue data editing problem is formulated as a constrained single optimisation problem that can be solved using GA method. The GA produces the shortest edited fatigue signal by selecting appropriate segments from a pool of labelling segments. Challenges arise due to constraints on the segment selection by deviation level over three signal properties, namely cumulative fatigue damage, root mean square and kurtosis values. Experimental results over several case studies show that the idea of solving fatigue signal editing within a framework of optimisation is effective and automatic, and that the GA is robust for constrained segment selection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymptotic vacuum solution at tokamak X-point tip

In the H-mode regime of diverted tokamaks, the presence of strong pressure gradients in the pedestal gives rise to a sizable bootstrap current, together with the Ohmic and Pfirsch–Schlueter currents, close to the separatrix. For such equilibria, the presence of finite current density close to the separatrix requires the reexamination of equilibrium properties. It is almost universally assumed that the two branches of the separatrix (the stable and unstable manifolds) are straight as they cross at the X-point. However, the opposite angles of the plasma-filled segment and vacuum one cannot be equal if the current density does not vanish at the separatrix on the plasma side. We solve this difficulty by chipping off a thin layer of plasma edge so that the sharp corner of the plasma-filled segment becomes a hyperbola. Using the conformal transformation, we found that in the assumption of a hyperbolic boundary, the X point moves beyond the plasma boundary to fall in the vacuum region. An acute angle of the plasma-filled segment leads to an obtuse opposite angle of vacuum segment and vice versa. In the case of an acute angle of the plasma-filled segment, the new X point shifts inside the X point formed by the asymptotes of a hyperbolic boundary; in the case of an obtuse angle of the plasma-filled segment, the new X point shifts outside the X point formed by the asymptotes of a hyperbolic plasma boundary. Furthermore, the results are important for understanding the X point features, which affect the tokamak edge stability and transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deferred Verification: The Role of New Verification Technologies and Approaches

Researchers at UNIDIR have recently proposed a fundamentally new approach to nuclear arms control verification, dubbed "deferred verification." The concept forgoes inspections at sensitive nuclear sites and inspections of nuclear materials or components in classified form. To implement this concept, a state first divides its territory into a closed segment and an open segment. The total fissile material inventory in the closed segment, which includes the weapon complex, is known and declared with very high accuracy. Essentially no inspections take place in the closed segment. Yet, inspectors have access to the open segment, which includes in particular the civilian nuclear sector. The fissile material inventory in the open segment is known with less accuracy, but uncertainties can be reduced over time using methods of nuclear archaeology. Deferred verification relies primarily on established safeguards techniques and avoids many unresolved verification challenges, including for example the need for information barriers for warhead confirmation measurements. At the same time, deferred verification faces some unique challenges. In this work, we explore some of these challenges and offer possible solutions while maintaining the strengths of the concept; to do so, we examine possible noncompliance strategies in which a state would seek to withhold a higher-than-declared inventory.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Structures of the G81A mutant form of the active chimera of (S)-mandelate dehydrogenase and its complex with two of its substrates

(S)-Mandelate dehydrogenase (MDH) from Pseudomonas putida, a membrane-associated flavoenzyme, catalyzes the oxidation of (S)-mandelate to benzoylformate. Previously, the structure of a catalytically similar chimera, MDH-GOX2, rendered soluble by the replacement of its membrane-binding segment with the corresponding segment of glycolate oxidase (GOX), was determined and found to be highly similar to that of GOX except within the substituted segments. Subsequent attempts to cocrystallize MDH-GOX2 with substrate proved unsuccessful. However, the G81A mutants of MDH and of MDH-GOX2 displayed {approx}100-fold lower reactivity with substrate and a modestly higher reactivity towards molecular oxygen. In order to understand the effect of the mutation and to identify the mode of substrate binding in MDH-GOX2, a crystallographic investigation of the G81A mutant of the MDH-GOX2 enzyme was initiated. The structures of ligand-free G81A mutant MDH-GOX2 and of its complexes with the substrates 2-hydroxyoctanoate and 2-hydroxy-3-indolelactate were determined at 1.6, 2.5 and 2.2 {angstrom} resolution, respectively. In the ligand-free G81A mutant protein, a sulfate anion previously found at the active site is displaced by the alanine side chain introduced by the mutation. 2-Hydroxyoctanoate binds in an apparently productive mode for subsequent reaction, while 2-hydroxy-3-indolelactate is bound to the enzyme in an apparently unproductive mode. The results of this investigation suggest that a lowering of the polarity of the flavin environment resulting from the displacement of nearby water molecules caused by the glycine-to-alanine mutation may account for the lowered catalytic activity of the mutant enzyme, which is consistent with the 30 mV lower flavin redox potential. Furthermore, the altered binding mode of the indolelactate substrate may account for its reduced activity compared with octanoate, as observed in the crystalline state.

59 BASIC BIOLOGICAL SCIENCES↗

Nuclear Considerations for the Application of Lanthanum Telluride in Future Radioisotope Power Systems

Thermoelectric-based radioisotope power systems (RPSs) produced in the United States convert the heat generated by the radioactive emission of alpha particles from plutonium dioxide ( 238 puO 2 ) into electricity by means of the Seebeck effect [1]. Certain designs for thermoelectric convertors propose the use of lanthanum telluride (La 3 Te 4 ) materials due to their significant conversion capabilities [2]. The generation of neutrons from spontaneous fission and alpha-neutron (α,n) reactions is also associated with the decay of 238 PuO 2 . A portion of these neutrons will interact with the thermoelectric materials and induce trace amounts of transmutation reactions in various lanthanum and tellurium isotopes. While very small quantities of several transmutation products are predicted, the most significant reaction channels are expected to produce trace amounts of iodine which will accumulate over time. Although iodine is classified as a halogen, it is the least reactive of the halogens, and as such, it is the most likely to be able to chemically convert back into the molecule I 2 . Since I 2 is a gas at RPS temperatures, it may be possible for iodine to attack other components in the thermoelectric cavity of an RPS system. Iodine reacts easily with metals to produce a wide variety of salts. This behavior could affect the performance of La 3 Te 4 thermoelectric devices, particularly the segmented architectures that include multiple sets of bonding and metallization layers. In this type of architecture, several segments of different thermoelectric materials are joined to increase the average thermoelectric figure of merit over a relatively large temperature gradient. It is plausible that sophisticated bonding/metallization layers could be required to join the segment interfaces to each other and to the cold- and hot-shoe materials. The long-term stability and performance of these segmented material combinations could degrade as a result of the potential formation and reactions of metal-iodide compounds at the segment interfaces. This paper (1) investigates the degree to which, if any, this process may threaten potential La 3 Te 4 thermoelectric technologies, (2) presents calculations of the amount of iodine generated over the operational life of a radioisotope thermoelectric generator design, and (3) discusses the potential effects of the resulting material's chemical reactions in a segmented couple-level architecture containing La 3 Te 4 . Conclusions drawn from combined particle transport, transmutation, and thermochemical calculations for La 3 Te 4 thermoelectric materials undergoing a notional 20-year mission scenario suggest that there is no significant potential for transmutation-induced thermoelectric (TE) performance degradation.

Smith, Michael↗

A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

The increased interest in {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an 'analysis region' to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the method that are user dependent were evaluated and resulted in initial estimates of the method's precision, which is in the order of {+-}10% of the average tumor volume estimate. With this work we have established the applicability of the GMM-based segmentation on clinical studies and we have made an initial assessment of the method's precision with respect to tumor volume segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of beam complexity in intensity-modulated radiation therapy treatment plans

Purpose: Excessive complexity in intensity-modulated radiation therapy (IMRT) plans increases the dose uncertainty, prolongs the treatment time, and increases the susceptibility to changes in patient or target geometry. To date, the tools for quantitative assessment of IMRT beam complexity are still lacking. In this study, The authors have sought to develop metrics to characterize different aspects of beam complexity and investigate the beam complexity for IMRT plans of different disease sites. Methods: The authors evaluated the beam complexity scores for 65 step-and-shoot IMRT plans from three sites (prostate, head and neck, and spine) and 26 volumetric-modulated arc therapy (VMAT) plans for the prostate. On the basis of the beam apertures and monitor unit weights of all segments, the authors calculated the mean aperture area, extent of aperture shape irregularity, and degree of beam modulation for each beam. Then the beam complexity values were averaged to obtain the complexity metrics of the IMRT plans. The authors studied the correlation between the beam complexity metrics and the quality assurance (QA) results. Finally, the effects of treatment planning parameters on beam complexity were studied. Results: The beam complexity scores were not uniform among the prostate IMRT beams from different gantry angles. The lateral beams had larger monitor units and smaller shape irregularity, while the anterior-posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest aperture irregularity, beam modulation, and normalized monitor units; the head and neck IMRT plans had large beam irregularity and beam modulation; and the spine stereotactic radiation therapy plans often had small beam apertures, which may have been associated with the relatively large discrepancies between planned and QA measured doses. There were weak correlations between the beam complexity scores and the measured dose errors. The prostate VMAT beams showed greater complexity than the prostate step-and-shoot IMRT beams. In the treatment planning process, the beam complexity increased as the minimum segment area decreased and as the number of optimization iterations and the maximum number of segments increased. Conclusions: The proposed metrics were effective in characterizing the beam complexity of different disease sites and for different treatment modalities. Efforts should be made to reduce the unnecessary complexity of IMRT beams to minimize the radiation dose uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-87: Lung Deformable Image Registration Using Surface Mesh Deformation for Dose Distribution Combination

Purpose: To allow a reliable deformable image registration (DIR) method for dose calculation in radiation therapy. This work proposes a performance assessment of a morphological segmentation algorithm that generates a deformation field from lung surface displacements with 4DCT datasets. Methods: From the 4DCT scans of 15 selected patients, the deep exhale phase of the breathing cycle is identified as the reference scan. Varian TPS EclipseTM is used to draw lung contours, which are given as input to the morphological segmentation algorithm. Voxelized contours are smoothed by a Gaussian filter and then transformed into a surface mesh representation. Such mesh is adapted by rigid and elastic deformations to match each subsequent lung volumes. The segmentation efficiency is assessed by comparing the segmented lung contour and the TPS contour considering two volume metrics, defined as Volumetric Overlap Error (VOE) [%] and Relative Volume Difference (RVD) [%] and three surface metrics, defined as Average Symmetric Surface Distance (ASSD) [mm], Root Mean Square Symmetric Surface Distance (RMSSD) [mm] and Maximum Symmetric Surface Distance (MSSD) [mm]. Then, the surface deformation between two breathing phases is determined by the displacement of corresponding vertices in each deformed surface. The lung surface deformation is linearly propagated in the lung volume to generate 3D deformation fields for each breathing phase. Results: The metrics were averaged over the 15 patients and calculated with the same segmentation parameters. The volume metrics obtained are a VOE of 5.2% and a RVD of 2.6%. The surface metrics computed are an ASSD of 0.5 mm, a RMSSD of 0.8 mm and a MSSD of 6.9 mm. Conclusion: This study shows that the morphological segmentation algorithm can provide an automatic method to capture an organ motion from 4DCT scans and translate it into a volume deformation grid needed by DIR method for dose distribution combination.

60 APPLIED LIFE SCIENCES↗

SU-E-T-250: New IMRT Sequencing Strategy: Towards Intra-Fraction Plan Adaptation for the MR-Linac

Purpose: To develop a new sequencer for IMRT planning that during treatment makes the inclusion of external factors possible and by doing so accounts for intra-fraction anatomy changes. Given a real-time imaging modality that will provide the updated patient anatomy during delivery, this sequencer is able to take these changes into account during the calculation of subsequent segments. Methods: Pencil beams are generated for each beam angle of the treatment and a fluence optimization is performed. The pencil beams, together with the patient anatomy and the above optimal fluence form the input of our algorithm. During each iteration the following steps are performed: A fluence optimization is done and each beam's fluence is then split to discrete intensity levels. Deliverable segments are calculated for each one of these. Each segment's area multiplied by its intensity describes its efficiency. The most efficient segment among all beams is then chosen to deliver a part of the calculated fluence and the dose that will be delivered by this segment is calculated. This delivered dose is then subtracted from the remaining dose. This loop is repeated until 90% of the dose has been delivered and a final segment weight optimization is performed to reach full convergence. Results: This algorithm was tested in several prostate cases yielding results that meet all clinical constraints. Quality assurance was performed on Delta4 and film phantoms for one of these prostate cases and received clinical acceptance after passing both gamma analyses with the 3%/3mm criteria. Conclusion: A new sequencing algorithm was developed to facilitate the needs of intensity modulated treatment. The first results on static anatomy confirm that it can calculate clinical plans equivalent to those of the commercially available planning systems. We are now working towards 100% dose convergence which will allow us to handle anatomy deformations. This work is financially supported by Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗

Image-based reconstruction of three-dimensional myocardial infarct geometry for patient-specific modeling of cardiac electrophysiology

Purpose: Accurate three-dimensional (3D) reconstruction of myocardial infarct geometry is crucial to patient-specific modeling of the heart aimed at providing therapeutic guidance in ischemic cardiomyopathy. However, myocardial infarct imaging is clinically performed using two-dimensional (2D) late-gadolinium enhanced cardiac magnetic resonance (LGE-CMR) techniques, and a method to build accurate 3D infarct reconstructions from the 2D LGE-CMR images has been lacking. The purpose of this study was to address this need. Methods: The authors developed a novel methodology to reconstruct 3D infarct geometry from segmented low-resolution (Lo-res) clinical LGE-CMR images. Their methodology employed the so-called logarithm of odds (LogOdds) function to implicitly represent the shape of the infarct in segmented image slices as LogOdds maps. These 2D maps were then interpolated into a 3D image, and the result transformed via the inverse of LogOdds to a binary image representing the 3D infarct geometry. To assess the efficacy of this method, the authors utilized 39 high-resolution (Hi-res) LGE-CMR images, including 36 in vivo acquisitions of human subjects with prior myocardial infarction and 3 ex vivo scans of canine hearts following coronary ligation to induce infarction. The infarct was manually segmented by trained experts in each slice of the Hi-res images, and the segmented data were downsampled to typical clinical resolution. The proposed method was then used to reconstruct 3D infarct geometry from the downsampled images, and the resulting reconstructions were compared with the manually segmented data. The method was extensively evaluated using metrics based on geometry as well as results of electrophysiological simulations of cardiac sinus rhythm and ventricular tachycardia in individual hearts. Several alternative reconstruction techniques were also implemented and compared with the proposed method. Results: The accuracy of the LogOdds method in reconstructing 3D infarct geometry, as measured by the Dice similarity coefficient, was 82.10% ± 6.58%, a significantly higher value than those of the alternative reconstruction methods. Among outcomes of electrophysiological simulations with infarct reconstructions generated by various methods, the simulation results corresponding to the LogOdds method showed the smallest deviation from those corresponding to the manual reconstructions, as measured by metrics based on both activation maps and pseudo-ECGs. Conclusions: The authors have developed a novel method for reconstructing 3D infarct geometry from segmented slices of Lo-res clinical 2D LGE-CMR images. This method outperformed alternative approaches in reproducing expert manual 3D reconstructions and in electrophysiological simulations.

60 APPLIED LIFE SCIENCES↗