Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

An Assessment of High-Resolution Gridded Temperature Datasets over California

Abstract High-resolution gridded datasets are in high demand because they are spatially complete and include important finescale details. Previous assessments have been limited to two to three gridded datasets or analyzed the datasets only at the station locations. Here, eight high-resolution gridded temperature datasets are assessed two ways: at the stations, by comparing with Global Historical Climatology Network–Daily data; and away from the stations, using physical principles. This assessment includes six station-based datasets, one interpolated reanalysis, and one dynamically downscaled reanalysis. California is used as a test domain because of its complex terrain and coastlines, features known to differentiate gridded datasets. As expected, climatologies of station-based datasets agree closely with station data. However, away from stations, spread in climatologies can exceed 6°C. Some station-based datasets are very likely biased near the coast and in complex terrain, due to inaccurate lapse rates. Many station-based datasets have large unphysical trends (>1°C decade−1) due to unhomogenized or missing station data—an issue that has been fixed in some datasets by using homogenization algorithms. Meanwhile, reanalysis-based gridded datasets have systematic biases relative to station data. Dynamically downscaled reanalysis has smaller biases than interpolated reanalysis, and has more realistic variability and trends. Dynamical downscaling also captures snow–albedo feedback, which station-based datasets miss. Overall, these results indicate that 1) gridded dataset choice can be a substantial source of uncertainty, and 2) some datasets are better suited for certain applications.

54 ENVIRONMENTAL SCIENCES↗

Climate data, analysis and models for the study of natural variability and anthropogenic change

Gridded Temperature Under prior/current support, we completed and published (Jones et al., 2012) the fourth major update to our global land dataset of near-surface air temperatures, CRUTEM4. This is one of the most widely used records of the climate system, having been updated, maintained and further developed with DoE support since the 1980s. We have continued to update the CRUTEM4 (Jones et al., 2012) database that is combined with marine data to produce HadCRUT4 (Morice et al., 2012). The emphasis in our use of station temperature data is to access as many land series that have been homogenized by National Meteorological Services (NMSs, including NCDC/NOAA, Asheville, NC). Unlike the three US groups monitoring surface temperatures in a similar way, we do not infill areas that have no or missing data. We can only infill such regions in CRUTEM4 by accessing more station temperature series. During early 2014, we have begun the extensive task of updating as many of these series as possible using data provided by some NMSs and also through a number of research projects and programs around the world. All the station data used in CRUTEM4 have been available since 2009, but in Osborn and Jones (2014) we have made this more usable using a Google Earth interface (http://www.cru.uea.ac.uk/cru/data/crutem/ge/ ). We have recently completed the update of our infilled land multi-variable dataset (CRU TS 3.10, Harris et al., 2014). This additionally produces complete land fields (except for the Antarctic) for temperature, precipitation, diurnal temperature range, vapour pressure and sunshine/cloud. Using this dataset we have calculated sc-PDSI (self-calibrating Palmer Drought Severity Index) data and compared with other PDSI datasets (Trenberth et al., 2014). Also using CRU TS 3.10 and Reanalysis datasets, we showed no overall increase in global temperature variability despite changing regional patterns (Huntingford et al., 2013). Harris et al. (2014) is an update of an earlier dataset (Mitchell and Jones, 2005) which also had earlier DoE support. The earlier dataset has been cited over 1700 times according to ResearcherID on 31/July/2014 and the recent paper has already been cited 22 times. Analyses of Temperature Data Using the ERA-Interim estimate of the absolute surface air temperature of the Earth (instead of in the more normal form of anomalies) we compared the result against estimates we produced in 1999 with earlier DoE support. The two estimates are surprisingly close (differing by a couple of tenths of a degree Celsius), with the average temperature of the world (for 1981-2010) being very close to 14°C (Jones and Harpham, 2013). We have assessed ERA-Interim against station temperatures from manned and automatic weather station measurements across the Antarctic (Jones and Lister, 2014). Agreement is generally excellent across the Antarctic Peninsula and the sparsely sampled western parts of Antarctica. Differences tend to occur over eastern Antarctica where ERA-Interim is biased warm (up to 6°C) in the interior of the continent and biased cool (up to 6°C) for some of the coastal locations. Opportunities presented themselves during 2012 for collaborative work with a couple of Chinese groups. Three papers develop new temperature series for China as a whole and also for the eastern third of China (Wang et al., 2014, Cao et al., 2013 and Zhao et al., 2014). A dataset of ~400 daily Chinese temperature stations has been added to the CRU datasets. The latter paper finds that urban effects are generally about 10% of the long-term warming trend across eastern China. A fourth paper (Wang et al., 2013) illustrates issues with comparisons between reanalyses and surface temperatures across China, a method that has been widely used by some to suggest urban heating effects are much larger in the region. ERA-Interim can be used but NCEP/NCAR comparisons are very dependent on the period analysed. Earlier a new temperature dataset of homogenized records was developed for China (Li et al., 2009). Urbanization has also been addressed for London (Jones and Lister, 2009) where two rural sites have not warmed more than a city centre site since 1900. Additionally, in Ethymiadis and Jones (2010) we show that land air temperatures agree with marine data around coastal areas, further illustrating that urbanization is not a major component of large-scale surface air temperature change. Early instrumental data (before the development of modern thermometer screens) have always been suspected of being biased warm in summer, due to possible direct exposure to the sun. Two studies (Böhm et al., 2010 and Brunet et al., 2010) show this for the Greater Alpine Region (GAR) and for mainland Spain respectively. The issue is important before about 1870 in the GAR and before about 1900 in Spain. After correction for the problems, summer temperature estimates before these dates are cooler by about 0.4°C. In Jones and Wigley (2010), we discussed the importance of the biases in global temperature estimation. Exposure and to a lesser extent urbanization are the most important biases for the land areas, but both are dwarfed by the necessary adjustments for bucket SST measurements before about 1950. Individual station homogeneity is only important at the local scale. This was additionally illustrated by Hawkins and Jones (2013) where we replicated the temperature record developed by Guy Stewart Callendar in papers in 1938 and 1961. Analyses of Daily Climate Data Work here indicates that ERA-Interim (at least in Europe, Cornes and Jones, 2013, discussed in more detail in this proposal) can be used to monitor extremes (using the ETCCDI software – see Zhang et al., 2011). Additionally, also as a result of Chinese collaboration, a new method of daily temperature homogenization has been developed (Li et al., 2014). In Cornes and Jones (2011) we assessed storm activity in the northeast Atlantic region using daily gridded data. Even though the grid resolution is coarse (5° by 5° lat/long) the changes in storm activity are similar to those developed from the pressure triangle approach with station data. Analyses of humidity and pressure data In Simmons et al. (2010) we showed a reduction in relative humidity over low-latitude and mid-latitude land areas for the 10 years to 2008, based on monthly anomalies of surface air temperature and humidity from ECMWF reanalyses (ERA-40 and ERA-Interim) and our earlier land-only dataset (CRUTEM3) and synoptic humidity observations (HadCRUH). Updates of this station-based humidity dataset (now called HadISDH) extend the record, showing continued reductions (Willett et al., 2013). Analyses of Proxy Temperature Data In Vinther et al. (2010), relationships between the seasonal stable isotope data from Greenland Ice Cores and Greenland and Icelandic instrumental temperatures were investigated for the past 150-200 years. The winter season stable isotope data are found to be influenced by the North Atlantic Oscillation (NAO) and very closely related to SW Greenland temperatures. The summer season stable isotope data display higher correlations with Icelandic summer temperatures and North Atlantic SST conditions than with local SW Greenland temperatures. In Jones et al. (2014) we use these winter isotope reconstructions to show the expected inverse correlation (due to the NAO) with winter-season documentary reconstructions from the Netherlands and Sweden over the last 800 years. Finally, in this section Jones et al. (2013) shows the agreement between tree-ring width measurements from Northern Sweden and Finland and an assessment of the link to explosive volcanic eruptions. An instrumental record for the region in the early 19th century indicates that the summer of 1816 was only slightly below normal, explaining why this year has normal growth for both ring width and density. GCM/RCM/Reanalysis Evaluation In this section we have intercompared daily temperature extremes across Europe in Cornes and Jones (2013) using station data, E-OBS and ERA-Interim. We have additionally considered the impact of the urban issue on the global scale using the results of the Compo et al. (2011) Reanalyses, 20CR. These only make use of SST and station pressure data. Across the world’s land areas, they indicate similar warming since 1900 to that which has occurred (Compo et al., 2013), again illustrating that urbanization is not the cause of the long-term warming. Changes in HadCRUH global land surface specific humidity and CRUTEM3 surface temperatures from 1973 to 1999 were compared to the CMIP3 archive of climate model simulations with 20th Century forcings (Willett et al., 2010). The models reproduce the magnitude of observed interannual variance over all large regions. Observed and modelled trends and temperature-humidity relationships are comparable with the exception of the extra-tropical Southern Hemisphere where observations exhibit no trend but models exhibit moistening.

54 ENVIRONMENTAL SCIENCES↗

Impact of hydrogen refueling configurations and market parameters on the refueling cost of hydrogen

The cost of hydrogen in early fuel cell electric vehicle (FCEV) markets is dominated by the cost of refueling stations, mainly due to the high cost of refueling equipment, small station capacities, lack of economies of scale, and low utilization of the installed refueling capacity. Using the hydrogen delivery scenario analysis model (HDSAM), this study estimates the impacts of these factors on the refueling cost for different refueling technologies and configurations, and quantifies the potential reduction in future hydrogen refueling cost compared to today’s cost in the United States. The current hydrogen refueling station levelized cost, for a 200 kg/day dispensing capacity, is in the range of 6–8 dollars/kg H 2 when supplied with gaseous hydrogen, and 8–9 dollars/kg H 2 for stations supplied with liquid hydrogen. After adding the cost of hydrogen production, packaging, and transportation to the station’s levelized cost, the current cost of hydrogen at dispensers for FCEVs in California is in the range of 13–15 dollars/kg H 2 . The refueling station capacity utilization strongly influences the hydrogen refueling cost. The underutilization of station capacity in early FCEV markets, such as in California, results in a levelized station cost that is approximately 40% higher than it would be in a scenario where the station had been fully utilized since it began operating. In future mature hydrogen FCEV markets, with a large demand for hydrogen, the refueling station’s levelized cost can be reduced to 2 dollars/kg H 2 as a result of improved capacity utilization and reduced equipment cost via learning and economies of scale.

33 ADVANCED PROPULSION SYSTEMS↗

Simultaneous beam sampling and aperture shape optimization for SPORT

Purpose: Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: The authors build a mathematical model with the fundamental station point parameters as the decision variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. Results: A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. Conclusions: The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Texas Hydrogen Highway Fuel Cell Hybrid Bus and Fueling Infrastructure Technology Showcase (Final Scientific/Technical Report)

The Texas Hydrogen Highway project has showcased a hydrogen fuel cell transit bus and hydrogen fueling infrastructure that was designed and built through previous support from various public and private sector entities. The aim of this project has been to increase awareness among transit agencies and other public entities on these transportation technologies, and to place such technologies into commercial applications, such as a public transit agency. The initial project concept developed in 2004 was to show that a skid-mounted, fully-integrated, factory-built and tested hydrogen fueling station could be used to simplify the design, and lower the cost of fueling infrastructure for fuel cell vehicles. The approach was to design, engineer, build, and test the integrated fueling station at the factory then install it at a site that offered educational and technical resources and provide an opportunity to showcase both the fueling station and advanced hydrogen vehicles. The two primary technology components include: Hydrogen Fueling Station: The hydrogen fueling infrastructure was designed and built by Gas Technology Institute primarily through a funding grant from the Texas Commission on Environmental Quality. It includes hydrogen production, clean-up, compression, storage, and dispensing. The station consists of a steam methane reformer, gas clean-up system, gas compressor and 48 kilograms of hydrogen storage capacity for dispensing at 5000 psig. The station is skid-mounted for easy installation and can be relocated if needed. It includes a dispenser that is designed to provide temperature compensated fills using a control algorithm. The total station daily capacity is approximately 50 kilograms. Fuel Cell Bus: The transit passenger bus built by Ebus, a company located in Downey, CA, was commissioned and acquired by GTI prior to this project. It is a fuel cell plug-in hybrid electric vehicle which is ADA compliant, has air conditioning sufficient for Texas operations, and regenerative braking for battery charging. It uses a 19.3 kW Ballard PEM fuel cell, will store 12.6 kg of hydrogen at 350 Bar, and includes a 60 kWh battery storage system. The objectives of the project included the following: (a) To advance commercialization of hydrogen-powered transit buses and supporting infrastructure; (b) To provide public outreach and education by showcasing the operation of a 22-foot fuel cell hybrid shuttle bus and Texas first hydrogen fueling infrastructure; and (c) To showcase operation of zero-emissions vehicle for potential transit applications. As mentioned above, the project successfully demonstrated an early vehicle technology, the Ebus plug-in hybrid fuel cell bus, and that success has led to the acquisition of a more advanced vehicle that can take advantage of the same fueling infrastructure. Needed hydrogen station improvements have been identified that will enhance the capabilities of the fueling infrastructure to serve the new bus and to meet the transit agency needs. Over the course of this project, public officials, local government staff, and transit operators were engaged in outreach and education activities that acquainted them with the real world operation of a fuel cell bus and fueling infrastructure. Transit staff members in the Dallas/Ft. Worth region were invited to a workshop in Arlington, Texas at the North Central Texas Council of Governments to participate in a workshop on hydrogen and fuel cells, and to see the fuel cell bus in operation. The bus was trucked to the meeting for this purpose so that participants could see and ride the bus. Austin area transit staff members visited the fueling site in Austin to be briefed on the bus and to participate in a fueling demonstration. This led to further meetings to determine how a fuel cell bus and fueling station could be deployed at Capital Metro Transit. Target urban regions that expressed additional interest during the project in response to the outreach meetings and showcase events include San Antonio and Austin, Texas. In summary, the project objectives were achieved in the following ways: Through presentations and papers provided to a variety of audiences in multiple venues, the project team fulfilled its goal of providing education and outreach on hydrogen technology to statewide audiences. The project team generated interest that exists well beyond the completion of the project, and indeed, helped to generate financial support for a subsequent hydrogen vehicle project in Austin. The University of Texas, Center for ElectroMechanics operated the fuel cell-electric Ebus vehicle for over 13,000 miles in Austin, Texas in a variety of routes and loading configurations. The project took advantage of prior efforts that created a hydrogen fueling station and fuel cell electric-hybrid bus and continued to verify their technical foundation, while informing and educating potential future users of how these technologies work.

03 NATURAL GAS↗

Projected network performance for next-generation xenon monitoring systems

Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ecological risk assessment of elemental pollution in sediment from Tunku Abdul Rahman National Park, Sabah

Eleven (11) surface sediment samples were collected from Tunku Abdul Rahman National Park, Sabah. The neutron activation analysis (NAA) and inductively coupled plasma-mass spectrometry (ICP-MS) techniques were applied for the determinations metal contents and their distributions in sediment samples. The results shown that Arsenic (As) concentrations are enriched at all sampling stations except for station TAR 09, with enrichment factor (EF) values ranged from 1.1 to 7.2. The elements such as Cd, Cr, Sb and U showed enrichment at a few stations and other elements (Cr, Cu, Pb, Th, Zn) shown as background levels in all stations. Degrees of contamination in this study were calculated base on concentrations of six elements (As, Cd, Cr, Cu, Pb, and Zn). TAR 11 station can be categorized as very high degree of contamination with degree of contamination value of 43.2. TAR 07 station can be categorized as a considerable degree of contamination (contamination value of 16.9). Six stations (TAR 01, 03, 04, 05, 06, 08, 10) showed moderate degree of contamination, with contamination values ranging from 8.0 to 16.0. TAR 02 and TAR 09 stations showed low degree of contaminations (< 8.0). TAR 11 showed very high ecological risk index (R{sub I}) with RI value is 916. TAR 07 and TAR 10 showed moderate ecological risk index with R{sub I} value 263 and 213, respectively. Other stations showed low ecological risk with RI values ranging from 42.3 to 117 (< 150). Very high ecological risk index could give an adverse effect to the benthic organism. The data obtained from the enrichment factor, degree of contamination and ecological risk index provided vital information, which can be used for future comparison. Information from the present study will be useful to the relevant government agencies and authorities in preparing preventive action to control direct discharge of heavy metals from industries, agro-base activities and domestic waste to the rivers and the sea.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of combined hydrogen, heat, and power as a bridge to a hydrogen transition.

Combined hydrogen, heat, and power (CHHP) technology is envisioned as a means to providing heat and electricity, generated on-site, to large end users, such as hospitals, hotels, and distribution centers, while simultaneously producing hydrogen as a by-product. The hydrogen can be stored for later conversion to electricity, used on-site (e.g., in forklifts), or dispensed to hydrogen-powered vehicles. Argonne has developed a complex-adaptive-system model, H2CAS, to simulate how vehicles and infrastructure can evolve in a transition to hydrogen. This study applies the H2CAS model to examine how CHHP technology can be used to aid the transition to hydrogen. It does not attempt to predict the future or provide one forecast of system development. Rather, the purpose of the model is to understand how the system works. The model uses a 50- by 100-mile rectangular grid of 1-square-mile cells centered on the Los Angeles metropolitan area. The major expressways are incorporated into the model, and local streets are considered to be ubiquitous, except where there are natural barriers. The model has two types of agents. Driver agents are characterized by a number of parameters: home and job locations, income, various types of 'personalities' reflective of marketing distinctions (e.g., innovators, early adopters), willingness to spend extra money on 'green' vehicles, etc. At the beginning of the simulations, almost all driver agents own conventional vehicles. They drive around the metropolitan area, commuting to and from work and traveling to various other destinations. As they do so, they observe the presence or absence of facilities selling hydrogen. If they find such facilities conveniently located along their routes, they are motivated to purchase a hydrogen-powered vehicle when it becomes time to replace their present vehicle. Conversely, if they find that they would be inconvenienced by having to purchase hydrogen earlier than necessary or if they become worried that they would run out of fuel before encountering a facility, their motivation to purchase a hydrogen-powered vehicle decreases. At vehicle purchase time, they weigh this experience, as well as other factors such as social influence by their peers, fuel cost, and capital cost of a hydrogen vehicle. Investor agents build full-service hydrogen fueling stations (HFSs) at different locations along the highway network. They base their decision to build or not build a station on their (imperfect) estimates of the sales the station would immediately generate (based on hydrogen-powered vehicle traffic past the location and other factors), as well as the growth in hydrogen sales they could expect throughout their investment horizon. The interaction between driver and investor agents provides the basis for growth in both the number of hydrogen vehicles and number of hydrogen stations. For the present report, we have added to this mix smaller, 'bare-bones' hydrogen dispensing facilities (HDFs) of the type that owners of CHHP facilities could provide to the public. The locations of these stations were chosen to match existing facilities that might reasonably incorporate CHHP plants in the future. Unlike the larger commercial stations, these facilities are built according to exogenously supplied timetables, and no attempt has been made to model the financial basis for the facilities. Rather, our objective is to understand how the presence of these additional stations might facilitate the petroleum-to-hydrogen transition. We discuss a base case in which the HDFs are not present, and then investigate the effects of introducing HDFs in various numbers; according to different timetables; with various production capacities; and with hydrogen selling at prices above, equal to, and below the commercial stations selling price. We conclude that HDFs can indeed be helpful in accelerating a petroleum-to-hydrogen transition. Placed in areas where investors might not be willing to install large for-profit HFSs, HDFs can serve as a bridge until demand for hydrogen increases to the point where larger stations are viable. For drivers to use them, however, HDFs must sell hydrogen at a price competitive with that of the larger HFSs. Because the marginal cost of producing hydrogen is expected to be higher for small capacities, HDFs may be uncompetitive without (possibly substantial) subsidies or other means to allow them to sell hydrogen at a price below the actual cost to produce and distribute it. Fortunately, HDFs do not need to be subsidized for very long. In our model, installing HDFs only as the demand for hydrogen increased was effective; then closing down all HDFs after five years into the transition made virtually no difference to the resultant accelerated outcome. Even installing much smaller numbers of HDFs only in the second and third years of the simulation and then closing them at the end of the fifth year was helpful.

08 HYDROGEN↗

Installation of Lysimeters Near Engineered Trench 3

Three new lysimeter stations were installed on the north rim of Engineered Trench 3 (Figure ES-1)at the E-Area Low Level Waste Facility (ELLWF). These stations were designated as ET3-VL-3, ET3-VL-4, and ET3-VL-5. The stations were installed in a line with the two existing stations (ET3-VL-1 and ET3-VL-2) and spaced approximately 100 ft apart. Two lysimeters were installed at each station at the depths shown in Table ES-1. Lysimeter placement was based on borehole lithology and was comparable to the existing lysimeter stations. The deepest lysimeter at each of the three new lysimeter stations was designated as the action-level lysimeter.Following installation, the lysimeters were purged and placed under vacuum for sampling. Sampling occurred in December 2020 with each lysimeter producing 1000 ml of water for tritium analysis. All lysimeters were below the administrative limit for ET3 (43.7 pCi/ml) with all but ET3-VL-5 (222) at background levels. ET3-VL-5 (222) had a tritium concentration of 27.5 pCi/ml.With the addition of the new lysimeters at ET3, the vadose zone monitoring system is now comprised of 309 active lysimeters at 102 lysimeter stations. There are 93 action-level lysimeters at 102 stations

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the limits of waveform correlation event detection as applied to three earthquake aftershock sequences.

Swarms of earthquakes and/or aftershock sequences can dramatically increase the level of seismicity in a region for a period of time lasting from days to months, depending on the swarm or sequence. Such occurrences can provide a large amount of useful information to seismologists. For those who monitor seismic events for possible nuclear explosions, however, these swarms/sequences are a nuisance. In an explosion monitoring system, each event must be treated as a possible nuclear test until it can be proven, to a high degree of confidence, not to be. Seismic events recorded by the same station with highly correlated waveforms almost certainly have a similar location and source type, so clusters of events within a swarm can quickly be identified as earthquakes. We have developed a number of tools that can be used to exploit the high degree of waveform similarity expected to be associated with swarms/sequences. Dendro Tool measures correlations between known events. The Waveform Correlation Detector is intended to act as a detector, finding events in raw data which correlate with known events. The Self Scanner is used to find all correlated segments within a raw data steam and does not require an event library. All three techniques together provide an opportunity to study the similarities of events in an aftershock sequence in different ways. To comprehensively characterize the benefits and limits of waveform correlation techniques, we studied 3 aftershock sequences, using our 3 tools, at multiple stations. We explored the effects of station distance and event magnitudes on correlation results. Lastly, we show the reduction in detection threshold and analyst workload offered by waveform correlation techniques compared to STA/LTA based detection. We analyzed 4 days of data from each aftershock sequence using all three methods. Most known events clustered in a similar manner across the toolsets. Up to 25% of catalogued events were found to be a member of a cluster. In addition, the Waveform Correlation Detector and Self Scanner identified significant numbers of new events that were not in either the EDR or regional catalogs, showing a lowering of the detection threshold. We extended our analysis to study the effect of distance on correlation results by applying the analysis tools to multiple stations along a transect of nearly constant azimuth when possible. We expected the number of events found via correlation would drop off as roughly 1/r2, where r is the distance from mainshock to station. However, we found that regional geological conditions influenced the performance of a given station more than distance. For example, for one sequence we clustered 25% of events at the nearest station to the mainshock (34 km), while our performance dropped to 2% at a station 550 km distant. However, we matched our best performance (25% clustering) at a station 198 km distant.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

H2Fills™ [SWR-19-67]

H2FillS: Hydrogen Filling Simulation The Hydrogen Filling Simulation (H2FillS) software is a thermodynamic model designed to track and report on the transient change in hydrogen temperature, pressure, and mass flow when filling a fuel cell electric vehicle (FCEV). H2FillS simulates gas flow from the hydrogen station to the FCEV storage system. Using empirical fueling data sets, the model has been validated over a range of fueling conditions to match common light-duty FCEV fill profiles. Overall, it provides significant benefits to the light-duty fueling market and fill knowledge gaps of the interaction between a hydrogen station and an FCEV. Capabilities Use the comprehensive H2FillS model to: Safely design and operate a hydrogen fueling station Support code refinement with readily available data Develop system and operational improvements to reduce capital or operating costs at hydrogen stations or on-board FCEVs. How It Works H2FillS uses a "drag-and-drop" graphical user interface to simulate station and vehicle systems with preset parameters for common hydrogen station components as default values. When needed, users can define their own parameters to create their own station or vehicle components. Download H2FillS in Two Steps Read the terms of the end user software license agreement. Register to download the software. There are two versions of the model: A full-station model starts the simulation at high-pressure ground storage, runs through a dispenser, and ends at a vehicle storage system. A partial-station model starts at the dispenser breakaway and consists solely of the dispenser components and the vehicle storage system. H2FillS will automatically output fill performance data from the vehicle by tracking pressure and temperature throughout the fill. Users can input their own fill profiles into the model to run a variety of simulations.

Peters, Michael↗

Economic Impacts Associated with Commercializing Fuel Cell Electric Vehicles in California: An Analysis of the California Road Map Using the JOBS H2 Model

Successful implementation of the California Road Map (the Road Map) for the introduction of hydrogen fueling stations to support a fleet of fuel cell electric vehicles (FCEVs) will produce positive economic impacts. Those impacts include jobs created or retained to develop and operate hydrogen fueling stations, earnings by businesses and workers so employed, and economic output generated by the activities required to develop and operate the stations. This report summarizes an analysis of those impacts as conducted by Argonne National Laboratory and RCF Economic and Financial Consultants for the U.S. Department of Energy’s Fuel Cell Technologies Office (FCTO). The analysis assumes that the cost and technical performance of stations that received awards under the 2014 solicitation of the California Energy Commission are representative of all stations to be deployed under the Road Map (subject to scale effects) and that information supplied by applicants representing the majority of those stations is representative of all. The analysis further assumes that all stations will be of a design similar to those developed in the initial years of the rollout, with additional equipment added as modules to achieve the targeted station capacity specified in the Road Map.

08 HYDROGEN↗

Development of the HyStEP Device

With the introduction of more fuel cell electric vehicles (FCEVs) on U.S. roadways, especially in California, the need for available hydrogen refueling stations is growing. While funding from the California Energy Commission is helping to solve this problem, solutions need to be developed and implemented to help reduce the time to commission a hydrogen station. The current practice of hydrogen station acceptance can take months because each vehicle manufacturer conducts their own testing and evaluation. This process is not practical or sufficient to support the timely development of a hydrogen fueling station network. To address this issue, as part of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project Sandia National Laboratories and the National Renewable Energy Laboratory along with a team of stakeholders and contractor Powertech Labs has developed the Hydrogen Station Equipment Performance (HyStEP) Device. The HyStEP Device is intended to be a surrogate for FCEVs that can be used to collect data on hydrogen station fueling performance. The device includes three Type IV 70 MPa tanks capable of storing a total of 9 kg H2 that are instrumented with pressure and temperature sensors. The tanks can be used individually or in parallel to simulate small, medium, and large fuel systems. The tanks are connected to a 70 MPa receptacle equipped with pressure and temperature sensor as well as infrared communications integrated with a data acquisition, analysis, and control system. The HyStEP Device is capable of performing tests defined in the test method standard CSA HGV 4.3 and providing the data needed to ensure that hydrogen stations meet the fueling protocol standard SAE J2601-2014. These include IrDA communication tests, fault detection tests, and communication and non-communication fueling.

30 DIRECT ENERGY CONVERSION↗

Antarctic near-surface air temperatures compared with ERA-Interim values since 1979

ERA-Interim reanalysis for near-surface air temperature agrees well with land stations in most regions with the principal exception of the Antarctic. Here we compare annual and monthly values from 40 manned and automatic weather stations (AWSs) with ERA-Interim between 1979 and 2013. In terms of absolute differences between ERA-Interim and the station observations, ERA-Interim is biased warm (by up to 5 °C) at the few inland stations, but biased cool at lower latitudes between 65°S and 78°S (by up to 6 °C) at some locations. These biases tend to reduce between the period 1979–1990 and 2002–2013 at many sites, but they increase at three sites on the Antarctic Peninsula. Comparisons of differences in variability show one or nine stations have standard deviation values for ERA-Interim 20% less or more than the station series. Time series agreement in terms of monthly correlations of anomalies is good (r ≥ 0.89) for most of the stations, but seven are below 0.80, with ten between the two thresholds. Finally, we produce an ‘Antarctic’ average time series by simple averaging of the 40 stations and ERA-Interim time series, as well as calculating an average based on all land points across the Antarctic from ERA-Interim. The series based on all land points is more variable on the year-to-year timescale and trends for the overall period are reduced.

54 ENVIRONMENTAL SCIENCES↗

Optimal charging management and infrastructure planning for free-floating shared electric vehicles

Recently, major car-sharing service providers have begun to include electric vehicles (EVs) in free-floating car-sharing fleets. For these EVs, downtime due to charging, including time spent traveling to and waiting in queues at charging stations in a sparse charging infrastructure network, is a major barrier to sustainable operation. An intuitive solution to overcome this barrier is to increase the number of fast-charging stations in the fleet service area. This paper studies the relationship between fleet vehicle downtime and the number of charging stations by modeling the fleet operations of a major car-sharing service provider. An integer programming model is developed that jointly optimizes charging station allocation, in terms of the number and location of charging stations, and the assignment of EVs to charging stations. Case study results showed that fleet vehicle charging time comprises 72-75% of the total downtime spent on charging trips. This indicates that charging time, as opposed to travel time or waiting time, is the dominant component of total fleet downtime for charging. The study also shows that by adding 5 to 20 new charging stations reduces total fleet downtime and travel time during charging trips by 2-4% and 26-49%, respectively. Although adding new charging stations to the fleet service area reduces total charging trip travel time significantly, it does not reduce total downtime significantly. Results also show that if the EV battery state of the charge (SOC) threshold—below which a charging trip is initiated—is less than 18%, not all EVs in the car-sharing fleet can be charged using the existing direct current fast chargers (DCFCs) in the fleet’s service area. Furthermore, this implies that adequate charging infrastructure coverage is required to ensure that EVs of a given range can operate in the car-sharing fleet.

25 ENERGY STORAGE↗

Study of movement of the western and central belts of Peninsular Malaysia using GPS data analysis

Since the large earthquakes in Sumatera and Nias, there were some tremors incidents at Bukit Tinggi. Therefore, a study on the earth’s crust movement and the effects of the earthquake in Indonesia on the tectonic blocks of Peninsular Malaysia have been carried out using GPS data analysis. GPS data from five MyRTKnet stations within Peninsular Malaysia have been analyzed to monitor the movement of two major tectonic blocks of Peninsular Malaysia which are the western belt represented by the Behrang (BEHR) and UPM Serdang (UPMS) stations and the central belt represented by Bentong (BENT), Jerantut (JRNT) and Temerloh (TLOH) stations. GPS data recorded from 2005 to 2010 were analysed based on horizontal and vertical displacements of the respective stations by using Trimble Business Centre (TBC) software. Based on the results of accumulated displacements of recorded GPS data from January 2006 to December 2013, it shows that the western belt which represented by UPMS has shifted 0.096m towards northwest with changes of ellipsoidal height of +0.030m while the central belt which represented by TLOH has shifted 0.080m towards northwest with changes of ellipsoidal height of −0.015m. Meanwhile, BENT station which is located on the Bentong-Raub suture zone turns to its original position as well as JRNT station. However, BEHR station which are located in western belt do not show any movements. All of these movements may be due to the influence of reactive faults in the stations area stimulated by several large earthquakes that occurred in 2005 to 2010. Study on using the GPS data analysis and combine with integrated geophysical methods are necessary to understand in detail about the tectonic evolution of Peninsular Malaysia.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Independent calculation of monitor units for VMAT and SPORT

Purpose: Dose and monitor units (MUs) represent two important facets of a radiation therapy treatment. In current practice, verification of a treatment plan is commonly done in dose domain, in which a phantom measurement or forward dose calculation is performed to examine the dosimetric accuracy and the MU settings of a given treatment plan. While it is desirable to verify directly the MU settings, a computational framework for obtaining the MU values from a known dose distribution has yet to be developed. This work presents a strategy to calculate independently the MUs from a given dose distribution of volumetric modulated arc therapy (VMAT) and station parameter optimized radiation therapy (SPORT). Methods: The dose at a point can be expressed as a sum of contributions from all the station points (or control points). This relationship forms the basis of the proposed MU verification technique. To proceed, the authors first obtain the matrix elements which characterize the dosimetric contribution of the involved station points by computing the doses at a series of voxels, typically on the prescription surface of the VMAT/SPORT treatment plan, with unit MU setting for all the station points. An in-house Monte Carlo (MC) software is used for the dose matrix calculation. The MUs of the station points are then derived by minimizing the least-squares difference between doses computed by the treatment planning system (TPS) and that of the MC for the selected set of voxels on the prescription surface. The technique is applied to 16 clinical cases with a variety of energies, disease sites, and TPS dose calculation algorithms. Results: For all plans except the lung cases with large tissue density inhomogeneity, the independently computed MUs agree with that of TPS to within 2.7% for all the station points. In the dose domain, no significant difference between the MC and Eclipse Anisotropic Analytical Algorithm (AAA) dose distribution is found in terms of isodose contours, dose profiles, gamma index, and dose volume histogram (DVH) for these cases. For the lung cases, the MC-calculated MUs differ significantly from that of the treatment plan computed using AAA. However, the discrepancies are reduced to within 3% when the TPS dose calculation algorithm is switched to a transport equation-based technique (Acuros™). Comparison in the dose domain between the MC and Eclipse AAA/Acuros calculation yields conclusion consistent with the MU calculation. Conclusions: A computational framework relating the MU and dose domains has been established. The framework does not only enable them to verify the MU values of the involved station points of a VMAT plan directly in the MU domain but also provide a much needed mechanism to adaptively modify the MU values of the station points in accordance to a specific change in the dose domain.

60 APPLIED LIFE SCIENCES↗