Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Characterization of renal stone composition by using fast kilovoltage switching dual-energy computed tomography compared to laboratory stone analysis: a pilot study

Purpose: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis. Methods: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference. Results: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Z{sub eff} alone, iodine imaging can compensated this fault. Conclusions: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Bounds for Burning Fence Graphs

Graph burning studies how fast a contagion, modeled as a set of fires, spreads in a graph. The burning process takes place in synchronous, discrete rounds. In each round, a fire breaks out at a vertex, and the fire spreads to all vertices that are adjacent to a burning vertex. Additionally, the burning number of a graph G is the minimum number of rounds necessary for each vertex of G to burn. We consider the burning number of the \(m \times n\) Cartesian grid graphs, written \(G_{m,n}\) . For \(m = \omega (\sqrt{n})\) , the asymptotic value of the burning number of \(G_{m,n}\) was determined, but only the growth rate of the burning number was investigated in the case \(m = O(\sqrt{n})\) , which we refer to as fence graphs. We provide new explicit bounds on the burning number of fence graphs \(G_{c\sqrt{n},n}\) , where \(c > 0\) .

79 ASTRONOMY AND ASTROPHYSICS↗

The first ensemble of kilometer-scale simulations of a hydrological year over the third pole

An accurate understanding of the current and future water cycle over the Third Pole is of great societal importance, given the role this region plays as a water tower for densely populated areas downstream. An emerging and promising approach for skillful climate assessments over regions of complex terrain is kilometer-scale climate modeling. As a foundational step towards such simulations over the Third Pole, we present a multi-model and multi-physics ensemble of kilometer-scale regional simulations for the hydrological year of October 2019 to September 2020. The ensemble consists of 13 simulations performed by an international consortium of 10 research groups, configured with a horizontal grid spacing ranging from 2.2 to 4 km covering all of the Third Pole region. These simulations are driven by ERA5 and are part of a Coordinated Regional Climate Downscaling EXperiment Flagship Pilot Study on Convection-Permitting Third Pole. The simulations are compared against available gridded and in-situ observations and remote-sensing data, to assess the performance and spread of the model ensemble compared to the driving reanalysis during the cold and warm seasons. Although ensemble evaluation is hindered by large differences between the gridded precipitation datasets used as a reference over this region, we show that the ensemble improves on many warm-season precipitation metrics compared with ERA5, including most wet-day and hour statistics, and also adds value in the representation of wet spells in both seasons. As such, the ensemble will provide an invaluable resource for future improvements in the process understanding of the hydroclimate of this remote but important region.

54 ENVIRONMENTAL SCIENCES↗

Sensor cost-effectiveness analysis for data-driven fault detection and diagnostics in commercial buildings

Data-driven building fault detection and diagnostics (FDD) is heavily dependent on sensors. However, common sensors from Building Automation Systems are not optimized to maximize accuracy in FDD. Installing additional sensors that provide more detailed building system information is key to maximizing the performance of FDD solutions. Here in this paper, we present a sensor cost analysis workflow to quantify the economic implications of installing new sensors for FDD using the concept of sensor threshold marginal cost (STMC). STMC does not represent actual sensor cost. Rather, it represents a target cost based on the economic benefit that would be realized through improved FDD performance and one or more specified economic criteria. We calculate STMCs for multiple possible fault types and use fault prevalence information to aggregate STMCs into a single dollar value to determine the cost-effectiveness of a potential sensor investment. We conducted a case study using Oak Ridge National Laboratory's Flexible Research Platform (FRP) test facility as a reference. The case study demonstrates the feasibility of the analysis and highlights the key cost considerations in sensor selection for FDD. The results also indicate that identifying and installing the few key sensor(s) is critical to cost-effectively improve FDD performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alkyd-amino resins based on waste PET for coating applications

Waste polyethylene terephthalate (PET) flakes were depolymerized by using propylene glycol (PG) in the presence of zinc acetate as catalyst. Glycolysis reaction products of waste PET obtained by using PET/glycol molar ratio 1/2. Two short oil alkyd resins of high acid values (30-40 mgKOH/g) were prepared from phthalic anhydride (PA), glycerin (G), coconut oil fatty acids (COFA) and glycolyzed products of waste PET (PET-based alkyd resins) or glycols (PG) (reference alkyd resins). These alkyd resins were blended with 30%, 40%, and 50% of a commercial urea-formaldehyde, melamine-formaldehyde and urea-formaldehyde/melamine-formaldehyde mixture (1/1 weight ratio) and heated at 140 deg. C. The physical and chemical properties such as drying time, hardness, abrasion resistance, adhesion strength, water resistance, alkaline resistance, acid resistance, gelation time, and thermal oxidative degradation resistance (with thermogravimetric analysis, TGA) of these alkyd-amino resins were investigated. The properties of the waste PET-based resins were found to be compatible with the properties of the reference resins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncovering the Relationship between Diameter and Height of Electrodeposited Lithium Protrusions in a Rigid Electrolyte

A promising approach for enabling rechargeable batteries with significantly higher energy densities than current lithium-ion batteries is by deploying lithium-metal anodes. However, the growth of lithium protrusions during charging presents significant challenges. Since these protrusions are often branched and filamentous in conventional liquid electrolytes, this problem is referred to in the literature as the “dendrite problem”. While solid electrolytes have the potential to solve this problem, protrusions grow in all electrolytes when the current density exceeds a critical value. Fundamentally understanding the formation is necessary to develop a rational approach for increasing the critical current density, but it is challenging due to the complex interplay between electrochemical and material properties. The diameters and heights of protrusions on lithium-metal anodes stabilized by a rigid block copolymer electrolyte were measured in situ by synchrotron hard X-ray microtomography. The diameter of the shorting protrusions increased linearly with increasing electrolyte thickness. Further, a universal linear relationship between protrusion height and diameter of both shorting and non-shorting protrusions was observed. A model based on the concentrated solution theory was used to establish the electrochemical and mechanical sources for our observations. Here, the computational analysis indicates that elastic and plastic deformation of both the lithium metal and the polymer are important to describe protrusion growth. Both stress-induced current density effects due to the deformation of the electrolyte near the protrusion and plastic deformation of lithium metal combine to give the counterintuitive result: the fastest-growing protrusions have the largest diameter.

25 ENERGY STORAGE↗

Experimental spectrum averaged cross sections (SACS) in 252 Cf(sf) neutron field and its impact on the evaluation of neutron standards

A new evaluation of spectrum averaged cross sections (SACS) of 235 U, 238 U, and 239 Pu measured in the 252 Cf(sf) reference neutron field is presented and found to be consistent with the original Mannhart SACS evaluation in IRDF-2002. The comprehensive vetted experimental database that includes SACS ratio and absolute SACS measurements of major actinides is being used to update the SACS database employed as input of the new GMApy code to derive the Neutron Standards. An update of the current neutron standards based on Time Projection Chamber (TPC) shape data, a new comprehensive uncertainty quantification, and revised SACS experimental database is proposed which result in a 0.7% increase of the evaluated 239 Pu(n,f)/ 235 U(n,f) crosssection ratio in the 1–5 MeV energy region. The increase is due to a 0.3% reduction of the standard 235 U(n,f) cross section and a 0.4% increase of the 239 Pu(n,f) reference cross section in the 1–5 MeV energy region. Those changes are well within estimated USU fission cross-section uncertainties of 1.2%, but are relevant for the evaluated mean values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Band offsets in ZrO{sub 2}/InGaZnO{sub 4} heterojunction

X-ray photoelectron spectroscopy was used to measure the energy discontinuity in the valence band ( White-Up-Pointing-Triangle E{sub V}) of amorphous InGaZnO{sub 4} (a-IGZO)/ZrO{sub 2} heterostructure deposited by DC and RF sputtering at room temperature, respectively. A value of White-Up-Pointing-Triangle E{sub V}= 0 eV was obtained by using the Ga and Zn 2p{sup 3} and In 3d{sup 3} energy levels as references. Given the experimental band gap of 3.1 eV and 5.8 eV for the a-IGZO and ZrO{sub 2}, respectively, this would indicate a conduction band offset of 2.7 eV in the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy density functionals from the strong-coupling limit applied to the anions of the He isoelectronic series

Anions and radicals are important for many applications including environmental chemistry, semiconductors, and charge transfer, but are poorly described by the available approximate energy density functionals. Here we test an approximate exchange-correlation functional based on the exact strong-coupling limit of the Hohenberg-Kohn functional on the prototypical case of the He isoelectronic series with varying nuclear charge Z < 2, which includes weakly bound negative ions and a quantum phase transition at a critical value of Z, representing a big challenge for density functional theory. We use accurate wavefunction calculations to validate our results, comparing energies and Kohn-Sham potentials, thus also providing useful reference data close to and at the quantum phase transition. We show that our functional is able to bind H{sup −} and to capture in general the physics of loosely bound anions, with a tendency to strongly overbind that can be proven mathematically. We also include corrections based on the uniform electron gas which improve the results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IMAGING DISCOVERY OF THE DEBRIS DISK AROUND HIP 79977

We present Subaru/HiCIAO H-band high-contrast images of the debris disk around HIP 79977, whose presence was recently inferred from an infrared excess. Our images resolve the disk for the first time, allowing characterization of its shape, size, and dust grain properties. We use angular differential imaging (ADI) to reveal the disk geometry in unpolarized light out to a radius of {approx}2'', as well as polarized differential imaging to measure the degree of scattering polarization out to {approx}1.''5. In order to strike a favorable balance between suppression of the stellar halo and conservation of disk flux, we explore the application of principal component analysis to both ADI and reference star subtraction. This allows accurate forward modeling of the effects of data reduction on simulated disk images, and thus direct comparison with the imaged disk. The resulting best-fit values and well-fitting intervals for the model parameters are a surface brightness power-law slope of S{sub out} = -3.2[ - 3.6, -2.9], an inclination of i = 84 Degree-Sign [81 Degree-Sign , 86 Degree-Sign ], a high Henyey-Greenstein forward-scattering parameter of g = 0.45[0.35, 0.60], and a non-significant disk-star offset of u = 3.0[ - 1.5, 7.5] AU = 24[ - 13, 61] mas along the line of nodes. Furthermore, the tangential linear polarization along the disk rises from {approx}10% at 0.''5 to {approx}45% at 1.''5. These measurements paint a consistent picture of a disk of dust grains produced by collisional cascades and blown out to larger radii by stellar radiation pressure.

79 ASTRONOMY AND ASTROPHYSICS↗

Parametric Modeling and Economic Analysis of a 2MW th 3-Stream sCO 2 Heat Exchanger

Here, this paper presents the design and cost optimization of a novel 2MW th 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that it uses reduced metal oxide particle-to-sCO2 heat exchanger for cost-effective energy storage applications. The design uses low velocity, laminar air as the re-oxidizing reactant to transfer the heat of the re-oxidizing reaction to a sCO2 power loop. The design of the heat exchanger is based on a 2-D, 3-fluid plate/fin heat transfer model. The model parameterizes the size, shape, and number of passages of the heat exchanger to calculate the temperature profile, pressure drop, and fluid velocities of all three fluids. Global heat exchanger parameters such as the effectiveness and total heat transferred to the sCO2 are then calculated for overall performance. Due to the value and increased use of sCO2 heat exchangers in power cycles, a cost model of the system based on the unique high temperature/high pressure operating conditions was created using quotes from reference projects and market analysis. These quoted air-to-sCO2 heat exchangers are then processed using multiple weighting factors pertinent to heat exchanger design, including heat exchanger type, maximum temperature, differential pressures, fluids, duty, and more. These factors are then used in an exponential function in order to generate a parameterized cost curve. The design and cost of the heat exchanger are then optimized using the SMPSO genetic algorithm in Python. The optimization objectives for the system are to maximize the overall system effectiveness, including an air recuperator for preheating, and to minimize unit costs. Additional constraints are added to the system for the sCO2 and air pressure drops, air velocity to reduce particle entrainment, and the length and volume of the heat exchanger.

Cost Model↗

TH-C-18A-05: Characteristics and Accuracy of CT Radiation Profile Width Measurements Using Radiochromic Films

Purpose: To investigate the impact of several acquisition and image analysis factors on the accuracy of CT beam width measurement using Gafchromic XR-QA2 film and an off the shelf document scanner. Methods: The film was carefully placed at the iso-center and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mAs), and nominal beam widths (1.25, 5, and 10 mm). Films were scanned on a RICOH MP3501 flat-bed document scanner using reflection mode and various spatial resolutions (100 to 600 dpi) and locations within the scanner bed. Radiation dose profiles were derived by converting the net reflection measurements to dose values (in mGy) through film calibration (which is also described here). The beam widths were characterized by the FWHM and FWTM of the dose profiles and the deviations from the hybrid reference standards were quantified. The impact of x-ray beam energy, exposure intensity, film calibration, and the uniformity and spatial resolution of the document scanner were investigated. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within approximately 5%. Increasing scanner spatial resolution increased the uncertainty in both FWHM and FWTM (R2 = 0.35–0.71), with the FWTM affected by more than five times than the FWHM (28% vs. 4.9%). When uncalibrated dose profiles were used, the FWHM and FWTM were over-estimated by as much as 11.6% and 7.6%, respectively. Narrower beam width was more sensitive to the film calibration than the wider one (R2 = 0.68 and 0.85 for the FWHM and FWTM, respectively). Conclusion: Measurement of CT beam width using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. It can provide adequate accuracy for all practical purposes with appropriate film calibration and scanner spatial resolution (100 dpi or less)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

gcm_eval (Global Climate Model Evaluation) [SWR-24-37]

The interplay between energy, climate, and weather is becoming more complex as our changing climate continues to affect the weather we experience which in turn drives changes in the ever increasing share of renewable energy generation and energy demand. Energy system analyses commonly rely on meteorological inputs to estimate renewable energy generation and energy demand; however, these inputs rarely represent the estimated impacts of future climate change. Climate models and publicly available climate change datasets can be used for this purpose, but the selection of inputs from the myriad of available models and datasets is a nuanced and often subjective process. There is no single perfect climate model or dataset for all applications. In this repository, we include software and the corresponding assessments of various global climate models (GCMs) from the Coupled Model Intercomparison Project (CMIP6), evaluating their skills with respect to the historical climate and comparing of their future projections of climate change. We focus on variables that directly affect the energy system including the representation of extreme values that can drive grid resilience events. The objective of this repository is not to recommend the best climate model and dataset for a given analysis, but instead to provide a reference to facilitate the selection of climate models and datasets in subsequent work.

Buster, Grant↗

Evaluation of Global Climate Models for Use in Energy Analysis

The interplay between energy, climate, and weather is becoming more complex due to increasing contributions of renewable energy generation, energy storage, electrified end uses, and the increasing frequency of extreme weather events. Energy system analyses commonly rely on meteorological inputs to estimate renewable energy generation and energy demand; however, these inputs rarely represent the estimated impacts of future climate change. Climate models and publicly available climate change datasets can be used for this purpose, but the selection of inputs from the myriad of available models and datasets is a nuanced and subjective process. In this work, we assess datasets from various global climate models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). We present evaluations of their skills with respect to the historical climate and comparisons of their future projections of climate change for two climate change scenarios. We present the results for different climatic and energy system regions and include interactive figures in the accompanying software repository. Previous work has presented similar GCM evaluations, but none have presented variables and metrics specifically intended for comprehensive energy systems analysis including impacts on energy demand, thermal cooling, hydropower, water availability, solar energy generation, and wind energy generation. We focus on GCM output meteorological variables that directly affect these energy system components including the representation of extreme values that can drive grid resilience events. The objective of this work is not to recommend the best climate model and dataset for a given analysis, but instead to provide a reference to facilitate the selection of climate models and scenarios in subsequent work.

14 SOLAR ENERGY↗

A State-Space Model of an Inverter-Based Microgrid for Multivariable Feedback Control Analysis and Design

In this work, a synchronous model for grid-connected and islanded microgrids is presented. The grid-connected model is based on the premise that the reference frame is synchronized with the AC bus. The quadrature component of the AC bus voltage can be cancelled, which allows to express output power as a linear equation for nominal values in the AC bus amplitude voltage. The model for the islanded microgrid is developed by integrating all the inverter dynamics using a state-space model for the load currents. This model is presented in a comprehensive way such that it could be scalable to any number of inverter-based generators using inductor–capacitor–inductor (LCL) output filters. The use of these models allows designers to assess microgrid stability and robustness using modern control methods such as eigenvalue analysis and singular value diagrams. Both models were tested and validated in an experimental setup to demonstrate their accuracy in describing microgrid dynamics. In addition, three scenarios are presented: non-controlled model, Linear-Quadratic Integrator (LQI) power control, and Power-Voltage (PQ/Vdq) droop–boost controller. Experimental results demonstrate the effectiveness of the control strategies and the accuracy of the models to describe microgrid dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven and Multiscale Modeling of DNA-Templated Dye Aggregates

Dye aggregates are of interest for excitonic applications, including biomedical imaging, organic photovoltaics, and quantum information systems. Dyes with large transition dipole moments (μ) are necessary to optimize coupling within dye aggregates. Extinction coefficients (ε) can be used to determine the μ of dyes, and so dyes with a large ε (>150,000 M –1 cm –1 ) should be engineered or identified. However, dye properties leading to a large ε are not fully understood, and low-throughput methods of dye screening, such as experimental measurements or density functional theory (DFT) calculations, can be time-consuming. In order to screen large datasets of molecules for desirable properties (i.e., large ε and μ), a computational workflow was established using machine learning (ML), DFT, time-dependent (TD-) DFT, and molecular dynamics (MD). ML models were developed through training and validation on a dataset of 8802 dyes using structural features. A Classifier was developed with an accuracy of 97% and a Regressor was constructed with an R2 of above 0.9, comparing between experiment and ML prediction. Using the Regressor, the ε values of over 18,000 dyes were predicted. The top 100 dyes were further screened using DFT and TD-DFT to identify 15 dyes with a μ relative to a reference dye, pentamethine indocyanine dye Cy5. Two benchmark MD simulations were performed on Cy5 and Cy5.5 dimers, and it was found that MD could accurately capture experimental results. The results of this study exhibit that our computational workflow for identifying dyes with a large μ for excitonic applications is effective and can be used as a tool to develop new dyes for excitonic applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance evaluation of a high-sensitivity tritium gas monitor using a pulse-shaping analyzer

A tritium gas monitor was developed by applying several techniques including pulse shape analysis. The optimum analyzer values were determined for parameters such as the bias (voltage) applied to the detector, counting gas flow rate, and mixing ratio of sample air to counting gas using an enclosed tritium reference source. After applying these optimized parameters, the factor for converting counting rate to tritium concentration was determined by conducting an experiment using tritiated methane gas. Finally, the detection limit of the monitor for air samples containing tritium was determined based on the conversion factor. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the effects of microsphere and surrounding material composition on {sup 90}Y dose kernels using egsnrc and mcnp5

Purpose: Recent advances in the imaging of {sup 90}Y using positron emission tomography (PET) and improved uncertainty in the branching ratio for the internal pair production component of {sup 90}Y decay allow for a more accurate determination of the activity distribution of {sup 90}Y microspheres within a patient. This improved activity distribution can be convolved with the dose kernel of {sup 90}Y to calculate the dose distribution within a patient. This work investigates the effects of microsphere and surrounding material composition on {sup 90}Y dose kernels using egsnrc and mcnp5 and compares the results of these two transport codes. Methods: Monte Carlo simulations were performed with egsnrc and mcnp5 to calculate the dose rate at multiple radial distances around various {sup 90}Y sources. Point source simulations were completed with mcnp5 to determine the optimal electron transport settings for this work. After determining the optimal settings, point source simulations were completed using egsnrc (user code edknrc) and mcnp5 in water and liver [as defined by the International Commission on Radiation Units and Measurements (ICRU) Report 44]. The results were compared to ICRU Report 72 reference data. Point source simulations were also completed in water with a density of 1.06 g{center_dot}cm{sup -3} to evaluate the effect of the density of the surrounding material. Glass and resin microsphere simulations were performed with average and maximum diameter and density values (based on values given in the literature) in water and in liver. The results were compared to point source simulation results using the same transport code and in the same surrounding material. All simulations had statistical uncertainties less than 1%. Results: The optimal transport settings in mcnp5 for this work included using the energy-and step-specific algorithm (DBCN 17J 2) and ESTEP set to 10. These settings were used for all subsequent simulations with mcnp5. The point source simulations in water for both egsnrc and mcnp5 were found to agree within 2% of the ICRU 72 reference data over the investigated range. Point source simulations in liver had large differences relative to ICRU 72, approaching -60% near the maximum range of {sup 90}Y. These differences are mostly attributed to the difference in density between water (1.0 g{center_dot}cm{sup -3}) and liver (1.06 g{center_dot}cm{sup -3}). Glass and resin microsphere simulations showed a slight decrease in the dose rate near the maximum range of {sup 90}Y relative to the point source simulations. The largest relative differences were approximately -4.2% and -2.8% for the glass and resin microspheres, respectively. Agreement between the egsnrc and mcnp5 simulations results was generally good. Conclusions: The presence of the microsphere material causes slight differences in the {sup 90}Y dose kernel compared to those calculated with point sources. Large differences were seen between simulations in water and those in liver. For the most accurate calculation of the dose distribution, the density of the patient's liver should be accounted for in the calculation of the dose kernel. Lastly, due to the need to determine the optimal transport settings with mcnp5, electron transport with this code should be used with caution.

61 RADIATION PROTECTION AND DOSIMETRY↗