Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection

Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

Schlegel, Todd T.↗

Recovery Act: "Near-Single-Crystalline Photovoltaic Thin Films on Polycrystalline, Flexible Substrates" (Final Report)

III-V photovoltaics have exhibited efficiencies above 40%, but have found only a limited use because of the high cost of single crystal substrates. At the other end of the spectrum, polycrystalline and amorphous thin film solar cells offer the advantage of low-cost fabrication, but have not yielded high efficiencies. Our program is based on single-crystalline-like thin film photovoltaics on polycrystalline substrates using biaxially-textured templates made by Ion Beam-Assisted Deposition (IBAD). MgO templates made by IBAD on flexible metal substrate have been successfully used for epitaxial growth of germanium films. In spite of a 4.5% lattice mismatch, heteroepitaxial growth of Ge was achieved on CeO 2 that was grown on IBAD MgO template. Room temperature optical bandgap of the Ge films was identified at 0.67 eV indicating minimal residual strain. Refraction index and extinction coefficient values of the Ge films were found to match well with that measured from a reference Ge single crystal. GaAs has been successfully grown epitaxially on Ge on metal substrate by molecular beam epitaxy. RHEED patterns indicate self annihilation of antiphase boundaries and the growth of a single domain GaAs. The GaAs is found to exhibit strong photoluminescence signal and, an existence of a relatively narrow (FWHM~20 meV) band-edge excitons measured in this film indicates a good optoelectronic quality of deposited GaAs. While excellent epitaxial growth has been achieved in GaAs on flexible metal substrates, the defect density of the films as measured by High Resolution X-ray Diffraction and etch pit experiments showed a high value of 5 x 10 8 per cm 2 . Cross sectional transmission electron microscopy of the multilayer architecture showed concentration of threading dislocations near the germanium-ceria interface. The defect density was found decrease as the Ge films were made thicker. The defects appear to originate from the MgO layer presumably because of large lattice mismatches between the various layers. The defect density in GaAs was reduced by a factor of five by adding a step of in-situ deposition of Ge by MBE on the sputtered Ge prior to GaAs growth. We have investigated device design strategies that would support development of high-efficiency devices in presence of dislocation densities of 10 8 cm -2 present in our epitaxial GaAs films. Results from modeling work show that with a proper emitter, base and doping selection, the modeled efficiency of a GaAs cells with dislocation densities of 10 9 and 10 8 cm -2 could be increased from 1% and 7% to 11% and 17% respectively. Under AM0, this single junction GaAs solar cell, has optimized value of emitter and base thickness of around 0.7 and 1.7 microns respectively, to give a maximum efficiency of 24.2%. We have fabricated complete GaAs solar cells using our Ge films on metal substrates. Pattern resolution of few microns with well-defined grid line of 30 microns has been realized on few cm square flexible templates. The ability to grow single-crystalline-like Ge films on flexible, polycrystalline substrates by reel-to-reel tape processing now provides an immense potential to fabricate high quality III-V photovoltaics on flexible, inexpensive substrates.

14 SOLAR ENERGY↗

Recovery Act : Near-Single-Crystalline Photovoltaic Thin Films on Polycrystalline, Flexible Substrates

III-V photovoltaics have exhibited efficiencies above 40%, but have found only a limited use because of the high cost of single crystal substrates. At the other end of the spectrum, polycrystalline and amorphous thin film solar cells offer the advantage of low-cost fabrication, but have not yielded high efficiencies. Our program is based on single-crystalline-like thin film photovoltaics on polycrystalline substrates using biaxially-textured templates made by Ion Beam-Assisted Deposition (IBAD). MgO templates made by IBAD on flexible metal substrate have been successfully used for epitaxial growth of germanium films. In spite of a 4.5% lattice mismatch, heteroepitaxial growth of Ge was achieved on CeO2 that was grown on IBAD MgO template. Room temperature optical bandgap of the Ge films was identified at 0.67 eV indicating minimal residual strain. Refraction index and extinction coefficient values of the Ge films were found to match well with that measured from a reference Ge single crystal. GaAs has been successfully grown epitaxially on Ge on metal substrate by molecular beam epitaxy. RHEED patterns indicate self annihilation of antiphase boundaries and the growth of a single domain GaAs. The GaAs is found to exhibit strong photoluminescence signal and, an existence of a relatively narrow (FWHM~20 meV) band-edge excitons measured in this film indicates a good optoelectronic quality of deposited GaAs. While excellent epitaxial growth has been achieved in GaAs on flexible metal substrates, the defect density of the films as measured by High Resolution X-ray Diffraction and etch pit experiments showed a high value of 5 * 10^8 per cm^2. Cross sectional transmission electron microscopy of the multilayer architecture showed concentration of threading dislocations near the germanium-ceria interface. The defect density was found decrease as the Ge films were made thicker. The defects appear to originate from the MgO layer presumably because of large lattice mismatches between the various layers. The defect density in GaAs was reduced by a factor of five by adding a step of in-situ deposition of Ge by MBE on the sputtered Ge prior to GaAs growth. We have investigated device design strategies that would support development of high-efficiency devices in presence of dislocation densities of 10^8 cm^-2 present in our epitaxial GaAs films. Results from modeling work show that with a proper emitter, base and doping selection, the modeled efficiency of a GaAs cells with dislocation densities of 10^9 and 10^8 cm^-2 could be increased from 1% and 7% to 11% and 17% respectively. Under AM0, this single junction GaAs solar cell, has optimized value of emitter and base thickness of around 0.7 and 1.7 microns respectively, to give a maximum efficiency of 24.2%. We have fabricated complete GaAs solar cells using our Ge films on metal substrates. Pattern resolution of few microns with well-defined grid line of 30 microns has been realized on few cm square flexible templates. The ability to grow single-crystalline-like Ge films on flexible, polycrystalline substrates by reel-to-reel tape processing now provides an immense potential to fabricate high quality III-V photovoltaics on flexible, inexpensive substrates.

14 SOLAR ENERGY↗

Interpretation of waverider performance data using computational fluid dynamics

A computational study was conducted to better understand experimental results obtained from wind tunnel tests of a Mach 4 waverider model and a comparative reference configuration. The experimental results showed that the performance of the reference configuration was slightly better than that of the waverider model. These results contradict waverider design theory, which suggests that a waverider optimized for maximum lift-to-drag should provide better performance than any other non-waverider configuration at a given design point, especially at hypersonic speeds. The computational results showed that the predicted surface pressure values and the integrated lift and drag coefficients from the pressure distributions were much lower for the reference model than for the flat-top model, due to the reference model bottom surface having a slight expansion. The lift-to-drag ratios for the flat-top model were higher due to a relatively low drag for the same amount of lift. These results indicate that the performance advantage of the reference model was due to the shape of the bottom surface and not due to the flat top surface. The results also showed that the reference model exhibited the same shock attachment characteristics as the waverider because the planform shapes were identical. CFD predictions show that the planform shape gives the waverider an advantage in performance over conventional hypersonic vehicles and that altering the bottom surface of a waverider does not cause significant performance degradation.

Cockrell, Charles E., Jr.↗

Interpretation of Waverider Performance Data Using Computational Fluid Dynamics

A computational study was conducted to better understand experimental results obtained from wind tunnel tests of a Mach 4 waverider model and a comparative reference configuration. The experimental results showed that the performance of the reference configuration was slightly better than that of the waverider model. These results contradict waverider design theory, which suggests that a waverider optimized for maximum lift-to-drag should provide better performance than any other non-waverider configuration at a given design point, especially at hypersonic speeds. The computational results showed that the predicted surface pressure values and the integrated lift and drag coefficients from the pressure distributions were much lower for the reference model than for the flat-top model, due to the reference model bottom surface having a slight expansion. The lift-to-drag ratios for the flat-top model were higher due to a relatively low drag for the same amount of lift. These results indicate that the performance advantage of the reference model was due to the shape of the bottom surface and not due to the flat top surface. The results also showed that the reference model exhibited the same shock attachment characteristics as the waverider because the planform shapes were identical. CFD predictions show that the planform shape gives the waverider an advantage in performance over conventional hypersonic vehicles and that altering the bottom surface of a waverider does not cause significant performance degradation.

Cockrell, Charles E., Jr.↗

Electrochemical measurement and analysis of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 in molten eutectic LiCl-KCl

For this work, electrochemical measurements of YCl 3 , ScCl 3 , GdCl 3 and MgCl 2 were obtained in molten LiCl-KCl eutectic at 773 K using a three-electrode configuration. Tungsten rods were used as the working and counter electrodes. Two quasi- and one reference electrode(s) (glassy carbon, nickel wire, and Ni/NiO) were used to collect electrochemical measurements of the analyte salts. Cyclic voltammetry data were analyzed to calculate values of diffusion coefficient, exchange current density, and charge transfer resistance and were determined to be on the order of 10 –5 cm 2 s –1 , 10 –2 A cm –2 , and 10 0 Ω; respectively. In general, the values of diffusion coefficients were found to be consistent with those reported of high-temperature molten salts. Relatively large values of exchange current density corresponded with smaller values of charge transfer resistance. These values were found to be reasonable in comparison to results available in the literature. The measured cyclic voltammograms were normalized with respect to both lithium reduction and chloride ion oxidation potentials. Such a normalization technique is effective for comparing experimentally obtained cyclic voltammetry data to those that have been published. An analysis of experimentally obtained results indicates the relation of electrode reactions (e.g., differences of reduction potentials) are independent of the choice of reference electrode. Additionally, the choice of reference electrode did not affect the electrochemical window, exchange current density, or diffusion coefficient values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Earth GRAM-99 and Trace Constituents

Global Reference Atmospheric Model (GRAM-99) is an engineering-level model of Earth's atmosphere. It provides both mean values and perturbations for density, temperature, pressure, and winds, as well as monthly- and geographically-varying trace constituent concentrations. From 0-27 km, GRAM thermodynamics and winds are based on National Oceanic and Atmospheric Administration Global Upper Air Climatic Atlas (GUACA) climatology. Above 120 km, GRAM is based on the NASA Marshall Engineering Thermosphere (MET) model. In the intervening altitude region, GRAM is based on Middle Atmosphere Program (MAP) climatology that also forms the basis of the 1986 COSPAR International Reference Atmosphere (CIRA). Atmospheric composition is represented in GRAM by concentrations of both major and minor species. Above 120 km, MET provides concentration values for N2, O2, Ar, O, He, and H. Below 120 km, species represented also include H2O, O3, N2O, CO, CH4, and CO2. At COSPAR 2002 a comparison was made between GRAM constituents below 120 km and those provided by Naval Research Laboratory (NRL) climatology. No current need to update GRAM constituent climatology in that height range was identified. This report examines GRAM (MET) constituents between 100 and 1000 km altitudes. Discrepancies are noted between GRAM (MET) constituent number densities and mass density or molecular weight. Near 110 km altitude, there is up to about 25% discrepancy between MET number density and mass density (with mass density being valid and number densities requiring adjustment). Near 700 km altitude there is also up to about 25% discrepancy between MET number density and mean molecular weight (with molecular weight requiring adjustment). In neither case are MET mass density estimates invalidated. These discrepancies have been traced to MET subroutines SLV (which affects 90-170 km height range) and SLVH (which affects helium above 440 km altitude). With these discrepancies corrected, results are presented to illustrate GRAM (MET) constituent mole fractions in terms of height-latitude cross sections from 100 to 1000 km altitude, and latitude-longitude 'maps' at 450 km (approximate height of International Space Station). Plans are discussed for an update of MET (and GRAM) to correct these constituent inconsistencies and to incorporate several new thermospheric model features.

Justus, C. G.↗

WE-AB-204-08: Uncertainties in Kinetic Modeling of Shortened Dynamic 18F-FMISO PET Due to Image Noise

Purpose: To assess uncertainties in voxel-wise kinetic modeling (KM) of dynamic 18F-FMISO PET (dPET) due to image noise for different lengths of dPET acquisitions. Methods: 12 tumor time activity curves (TACs) deduced from 6 head and neck cancer patient dPET datasets (45min dPET + 10min frames at ∼95min and ∼160min respectively) were modeled using an irreversible two-tissue compartment model to estimate kinetic rate constants (KRCs) k3, vB, K1, and K1/k2 (reference standard). For each modeled TAC, 1000 noisy TACs were simulated by adding Gaussian noise with standard deviation equivalent to that observed on a voxel level in GE DSTE PET-CT. KM was conducted for each set of noisy TACs using (i) full dataset (170min), and repeated using (ii) 105min and (iii) 45min shortened subsets, with an input function that was image-derived from the dPET dataset of matching length. Absolute value of percent difference between KRCs from noisy TACs as estimated from either of 3 datasets and reference standard KRCs was used to represent bias. Results: For all KRCs, bias was higher for shortened datasets. For k3, bias was lower when actual k3 was higher: from 7%±5% (170min), 9%±7% (105min), and 14%±11% (45min) (actual k3=0.0098), to 32%±25% (170min), 45%±34% (95min), and 79%±48% (45min) (actual k3=0.0008). Similar relationship was observed for vB, with bias being between ∼7% (actual vB=0.28) and ∼26–34% (actual vB=0.08). For K1 [K1/k2], bias was ∼6–10% [∼2–3%] (dependence on actual value of K1 [K1/k2] was not observed). Conclusion: Uncertainties in voxel-wise KM of shortened 18F-FMISO dPET due to image noisy only are larger for shorter acquisitions and, for k3 [vB], the bias was found to be inversely correlated with the actual values of k3 [vB]. Using 45min subset, k3, vB, K1, and K1/k2 could be estimated to within ∼15–80%, ∼10–35%, ∼10%, and ∼3%, respectively.

60 APPLIED LIFE SCIENCES↗

C-statistic fitting routines: User's manual and reference guide

The computer program is discussed which can read several input files and provide a best set of values for the functions provided by the user, using either C-statistic or the chi(exp 2) statistic method. The program consists of one main routine and several functions and subroutines. Detail descriptions of each function and subroutine is presented. A brief description of the C-statistic and the reason for its application is also presented.

Nousek, John A.↗

Performance Measurement of a Multi-Level/Analog Ferroelectric Memory Device Design

Increasing the memory density and utilizing the unique characteristics of ferroelectric devices is important in making ferroelectric memory devices more desirable to the consumer. This paper describes the characterization of a design that allows multiple levels to be stored in a ferroelectric based memory cell. It can be used to store multiple bits or analog values in a high speed nonvolatile memory. The design utilizes the hysteresis characteristic of ferroelectric transistors to store an analog value in the memory cell. The design also compensates for the decay of the polarization of the ferroelectric material over time. This is done by utilizing a pair of ferroelectric transistors to store the data. One transistor is used a reference to determinethe amount of decay that has occurred since the pair was programmed. The second transistor stores the analog value as a polarization value between zero and saturated. The design allows digital data to be stored as multiple bits in each memory cell. The number of bits per cell that can be stored will vary with the decay rate of the ferroelectric transistors and the repeatability of polarization between transistors. This paper presents measurements of an actual prototype memory cell. This prototype is not a complete implementation of a device, but instead, a prototype of the storage and retrieval portion of an actual device. The performance of this prototype is presented with the projected performance of the overall device. This memory design will be useful because it allows higher memory density, compensates for the environmental and ferroelectric aging processes, allows analog values to be directly stored in memory, compensates for the thermal and radiation environments associated with space operations, and relies only on existing technologies.

MacLeod, Todd C.↗

TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

TH-A-204-02: Part II - Worldwide Radiation Metrology

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

Can portable glucose and lactate meters be a useful tool in quantifying stress of juvenile Chinook salmon?

Blood plasma analyses can provide researchers, aquaculture facilities and fisheries managers with valuable insights into the physiological state and welfare of fish. For example, glucose and lactate are part of the secondary stress response system, and elevated concentrations are indicators of stress. However, analysing blood plasma in the field can be logistically difficult and typically involves sample storage and transport to quantify concentrations in a laboratory setting. Portable glucose and lactate meters offer an alternative to laboratory assays and have shown to be relatively accurate in fish, but these tools have only been validated for a few fish species. The objective of this study was to investigate if portable meters could be reliably used in Chinook salmon (Oncorhynchus tshawytscha). As part of a larger stress response study, juvenile Chinook salmon (157 ± 17 mm fork length [mean ± standard deviation; SD]) were exposed to stress-inducing treatments and sampled for blood. Laboratory reference glucose concentrations (milligrams per deciliter; mg/dl; n = 70) were positively correlated with the Accu-Check Aviva meter (Roche Diagnostics, Indianapolis, IN) measurements (R 2 = 0.79), although glucose values were 1.21 ± 0.21 (mean ± SD) times higher in the laboratory than with the portable meter. Lactate concentrations (milliMolar; mM; n = 52) of the laboratory reference were also positively correlated (R 2 = 0.76) with the Lactate Plus meter (Nova Biomedical, Waltham, MA) and were 2.55 ± 0.50 times higher than portable meter. Our results indicate both meters could be used to measure relative glucose and lactate concentrations in Chinook salmon and provide fisheries professionals with a valuable tool, particularly in remote field settings.

59 BASIC BIOLOGICAL SCIENCES↗

Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a {sup 60}Co Magnetic Resonance Image Guidance Radiation Therapy System

Purpose: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating {sup 60}Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. Methods and Materials: The ViewRay treatment planning system (Oakwood Village, OH) was used to create {sup 60}Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The {sup 60}Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. Results: All {sup 60}Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for {sup 60}Co was within <1% and 3% of linac plans for 100% and 95% prescription reference isodoses, respectively, and heterogeneity was on average 4% greater. Comparisons of OAR mean dose showed generally better sparing with linac plans in the low-dose range <20 Gy, but comparable sparing for organs with mean doses >20 Gy. The mean doses for all {sup 60}Co plan OARs were within clinical tolerances. Conclusions: A commercial {sup 60}Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter (OSWEC) reference model design in a complementary manner to Reference Models 1-4 contained in the above report. A conceptual design for a taut moored oscillating surge wave energy converter was developed. The design had an annual electrical power of 108 kilowatts (kW), rated power of 360 kW, and intended deployment at water depths between 50 m and 100 m. The study includes structural analysis, power output estimation, a hydraulic power conversion chain system, and mooring designs. The results were used to estimate device capital cost and annual operation and maintenance costs. The device performance and costs were used for the economic analysis, following the methodology presented in SAND2013-9040 that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays up to 100 devices. The levelized cost of energy estimated for the Reference Model 5 OSWEC, presented in this report, was for a single device and arrays of 10, 50, and 100 units, and it enabled the economic analysis to account for cost reductions associated with economies of scale. The baseline commercial levelized cost of energy estimate for the Reference Model 5 device in an array comprised of 10 units is $1.44/kilowatt-hour (kWh), and the value drops to approximately $0.69/kWh for an array of 100 units.

16 TIDAL AND WAVE POWER↗

Follow-on to a report on the Applicability of the “Gallet equation” to the vegetation clearances of NERC Reliability Standard FAC-003-2

In earlier work, a study done at the Pacific Northwest National Laboratory examined a NERC proposed standard specifying clearances between vegetation and power lines. The method proposed for calculating the clearances was based on the results of testing for high-voltage line designs. An equation developed to relate the results of testing with rod-plane gaps to proposed tower window sizes was incorporated into the calculations. The equation in question, sometimes called the “Gallet equation,” describes the insulation performance of the atmosphere for air gaps of a few meters. The equation was described in the PNNL study as a good and simple-to-use way to solve a problem made difficult by the nonlinear interactions of the variables. For calculations based on this equation, a certain set of assumptions must be made. In particular, a value for a quantity called the “gap factor” is needed. This is the amount by which the gap to be modeled by the equation is stronger than the reference gap that was used in developing the Gallet equation. That reference gap is the gap between a rod and a plane. This follow-on report examines the effect on flashover probabilities of assuming an incorrect value for the gap factor. In particular, the flashover probability is found that would result from using a value of 1.3 when a gap factor of 1.0 should be applied. It is shown that with these assumptions the probability of a flashover changes from being extremely unlikely (about 1 in 1000 chance) to a virtual certainty (about 97% chance).

high voltage: flashover: Gallet equation↗

Hot-gas-side heat transfer with and without film cooling on a simulated nuclear rocket thrust chamber using H2-O2

Heat-transfer coefficients were obtained on a thrust chamber which simulated the geometry of the NERVA nuclear rocket. The tests were performed with and without peripheral film cooling over a chamber pressure range of 1.05 million to 5.84 million newtons per square meter (153 to 847 psia). With no film cooling, the overall axial variation in the value of the correlation coefficient C of the equation (Stanton)* (Prandtl)* to the 0.7ths power = C(Reynolds)* to the -0.2ths power, where * indicates the reference enthalpy condition, was reduced 66 percent when the local diameter in the Reynolds number was replaced by the axial distance from the injector face. The average peak values of C were reduced 25 percent with 2 and 3.75 percent cooling and 50 percent with 7.5 percent cooling.

Quentmeyer, R. J.↗

Pxl

The code consists of several scripts. The image is fetched from a predefined URL, downloaded, and is displayed in the virtual environment at a predefined location. The image is also dynamically scaled to fit in the virtual environment depending on its size. The image is sent to have each pixel's value written to a CSV file. While the CSV is being written, a dictionary is populated with values that map each pixel to a temperature reading. The image's height, width, position and references to its corners are sent to make a button that is the same size as the image and placed right behind the image in the virtual scene. The button defines behavior that should be triggered when the user pushes the image. Unity provides visual cues that alert the user when they are about to touch something in the virtual environment. The code holds references to the cues for the left and right hands. The button queries the cue tracker and receives the position of the active cue in the form of a 3D vector. The 3D vector is compared to the bottom left corner of the image to transform the world space coordinates of the cue to the pixel space of the image. The specific pixel is approximated relative to how far left and up the user touched from the bottom left corner of the image. The approximated pixel value, which is represented as a coordinate in 2D space, is used to retrieve the temperature value associated with the approximated pixel. A window of text is then updated to display the temperature reading.

. Otis, KrystianeS [Idaho National Laboratory (INL↗