Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RELATIVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams

In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number of chambers. Measured depth dose data were compared with Monte Carlo calculated depth doses using the EGSnrc Monte Carlo package and the BEAMnrc user code. The accuracy of the phase space files generated by BEAMnrc was verified by calculating the half-value layer and comparing with the measured half-value layer of each x-ray beam. The results indicate that the Advanced Markus, Markus, NACP, and Roos parallel plate ionization chambers were suitable for the measurement of depth dose data in this beam quality range with an uncertainty of less than 3%, including in the regions close to the water surface. While the relative detector response of the Farmer and scanning thimble chambers exhibited a better energy response, they were not suitable for depth dose measurements in the first 5 mm below the water surface with differences of up to 12% in the surface dose measurement for the 50 kVp x-ray beam. These differences were due to dose artifacts generated by the chamber size and the dose gradient. However, at depths greater than 5 mm, the Farmer and thimble scanning chambers gave uncertainties of less than 3% for the depth dose measurements for all beam energies. The PTW PinPoint 31006 chamber was found to give varying dose differences of up to 8% depending on the x-ray beam energy; this was attributed to the steel central electrode. The authors recommend that one of the parallel plate ionization chambers investigated be used to determine depth dose data for kilovoltage x-ray beams in the energy range studied and give correct dose information close to the surface and at depth in the water phantom.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microdosimetric study on influence of low energy photons on relative biological effectiveness under therapeutic conditions using 6 MV linac

Purpose: Microdosimetry has been developed for the evaluation of radiation quality, and single-event dose-mean lineal energy y{sub D} is well-used to represent the radiation quality. In this study, the changes of the relative biological effectiveness (RBE) values under the therapeutic conditions using a 6 MV linac were investigated with a microdosimetric method. Methods: The y{sub D} values under the various irradiation conditions for x-rays from a 6 MV linac were measured with a tissue-equivalent proportional counter (TEPC) at an extremely low dose rate of a few tens of {mu}Gy/min by decreasing the gun grid voltage of the linac. According to the microdosimetric kinetic model (MK model), the RBE{sub MK} values for cell killing of the human salivary gland (HSG) tumor cells can be derived if the y{sub D} values are obtained from TEPC measurements. The Monte Carlo code GEANT4 was also used to calculate the photon energy distributions and to investigate the changes of the y{sub D} values under the various conditions. Results: The changes of the y{sub D} values were less than approximately 10% when the field size and the depth in a phantom varied. However, in the measurements perpendicular to a central beam axis, large changes were observed between the y{sub D} values inside the field and those outside the field. The maximum increase of approximately 50% in the y{sub D} value outside the field was obtained compared with those inside the field. The GEANT4 calculations showed that there existed a large relative number of low energy photons outside of the field as compared with inside of the field. The percentages of the photon fluences below 200 keV outside the field were approximately 40% against approximately 8% inside the field. By using the MK model, the field size and the depth dependence of the RBE{sub MK} values were less than approximately 2% inside the field. However, the RBE{sub MK} values outside the field were 6.6% higher than those inside the field. Conclusions: The increase of the RBE{sub MK} values by 6.6% outside the field was observed. This increase is caused by the change of the photon energy distributions, especially the increase of the relative number of low energy photons outside the field.

43 PARTICLE ACCELERATORS↗

SU-E-I-29: Generalized Relative Object Detectability (G-ROD): A Metric for Comparing X-Ray Imaging Detector Systems

Purpose: To determine the relative task-specific performance of two x-ray imaging detectors including the effect of other components of the imaging chain. Methods: The relative object detectability (ROD) was defined as the ratio of the integral of the detective-quantum efficiency (DQE) of a detector weighted by the square of the Fourier Transform (or frequency spectrum) of the object to the same integral for a second detector. The generalized ROD (G-ROD) is calculated by replacing DQE by the generalized DQE (GDQE) which includes geometric unsharpness and scatter to evaluate the total imaging chain. The G-ROD was calculated for the micro-angiographic fluoroscope (MAF) relative to a flat-panel detector (FPD) for low (1.05) and high (1.2) magnifications with two focal-spot sizes, small (0.3 mm) and medium (0.5 mm), and for the same value of scatter fraction. Solid spheres from 50 to 600 microns were simulated as the objects for this evaluation. The G-ROD results were compared with those of the ROD which considers the detectors alone. Results: For 50-micron spheres, the ROD is 7.93 and, for the small [medium] focus, the G-ROD is 6.74 [5.22] at low magnification and 3.03 [1.66] at high magnification, indicating superior performance of the MAF particularly at low magnification. Both ROD and G-ROD decrease monotonically with size and remain around one above 400-microns. The G-ROD decreases more dramatically with low compared to high magnification for both focal spots. Conclusion: In all cases, the MAF performs better than the FPD and the decreasing trend of the G-ROD indicates that the performance of both detectors becomes similar as the object size increases and becomes nearly equal above 400-micron diameter sphere size. Finally, increased magnification and focal-spot size decrease the G-ROD, indicting that they degrade the performance of the MAF more than that of the FPD for a small-object viewing task. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-175: Evaluation of the Relative Output Ratio for Collimator Jaw and MLC Defined Small Static 6MV Photon Fields

Purpose: To evaluate relative output ratio of collimator jaw and MLC defined small photon fields. Methods: Relative output ratios were measured using Gafchromic EBT3 film for a 6 MV photon beam on a Novalis Tx with HD120 MLC. Beam collimation was achieved by the jaws for 1.0 cm and 3.0 cm and MLC defined square field sizes between 0.5 cm and 1.0 cm with varying jaw settings between 2.0 and 4.0 cm. Film pieces were exposed to 4 Gy. Experiments were repeated with each session consisting of five consecutive exposures for the given MLC and/or jaw collimation and with the MLC and the jaws reset for each exposure. Films were scanned using EPSON 10000XL flatbed scanner approximately 24 hours after exposure in 48 bit RGB format at 150 dpi. Film calibration data were corrected for daily linac output variations. Doses were evaluated using the green channel with square ROI sizes of 0.1 – 0.6 cm. Converted doses were normalised for output ratio calculation using the 3.0 cm field as a machine specific reference field size. Mean output ratio and coefficient of variation (CV) were calculated for each experimental session. Results: For the Novalis 6 MV photon beam the output ratios between 0.719 and 0.872 have been measured for the jaw/MLC combinations tested. For a jaw setting of 4.0 cm field, the mean CV of the output ratios increased from 0.77% to 1.48% with decreasing MLC field size from 1.0 cm to 0.5 cm. For a nominal MLC 1.0 cm field, the CV increased to 1.00% from 0.77% with reducing jaw field size from 4.0 cm to 2.0 cm. Conclusion: The relative output ratio and the associated CV were dependent on the collimator jaw and MLC settings. The field size dependent CV showed similar trends to those reported in the literature.

60 APPLIED LIFE SCIENCES↗

SU-E-T-599: The Variation of Hounsfield Unit and Relative Electron Density Determination as a Function of KVp and Its Effect On Dose Calculation Accuracy

Purpose: To investigate the differences in relative electron density for different energy (kVp) settings and the effect that these differences have on dose calculations. Methods: A Nuclear Associates 76-430 Mini CT QC Phantom with materials of known relative electron densities was imaged by one multi-slice (16) and one single-slice computed tomography (CT) scanner. The Hounsfield unit (HU) was recorded for each material with energies ranging from 80 to 140 kVp and a representative relative electron density (RED) curve was created. A 5 cm thick inhomogeneity was created in the treatment planning system (TPS) image at a depth of 5 cm. The inhomogeneity was assigned HU for various materials for each kVp calibration curve. The dose was then calculated with the analytical anisotropic algorithm (AAA) at points within and below the inhomogeneity and compared using the 80 kVp beam as a baseline. Results: The differences in RED values as a function of kVp showed the largest variations of 580 and 547 HU for the Aluminum and Bone materials; the smallest differences of 0.6 and 3.0 HU were observed for the air and lung inhomogeneities. The corresponding dose calculations for the different RED values assigned to the 5 cm thick slab revealed the largest differences inside the aluminum and bone inhomogeneities of 2.2 to 6.4% and 4.3 to 7.0% respectively. The dose differences beyond these two inhomogeneities were between 0.4 to 1.6% for aluminum and 1.9 to 2.2 % for bone. For materials with lower HU the calculated dose differences were less than 1.0%. Conclusion: For high CT number materials the dose differences in the phantom calculation as high as 7.0% are significant. This result may indicate that implementing energy specific RED curves can increase dose calculation accuracy.

60 APPLIED LIFE SCIENCES↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-07: Inaccuracy of Lesion Blood Flow Quantification Related to the Proton Density Reference Image in Arterial Spin Labeling MRI of Brain Tumors

Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR, 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients with brain tumors.

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-09: Application of a Modified Microdosimetric-Kinetic Model to Analyze Relative Biological Effectiveness of Ions Relevant to Light Ion Therapy Using the Particle Heavy Ion Transport System

Purpose: To evaluate the dose and biological effectiveness of various ions that could potentially be used for actively scanned particle therapy. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary particles for 1H beams and ten million particles for 4He, 7Li, 10B, 12C, 14N, 16O, and 20Ne were simulated for 0.6cm diameter pencil beams. Beam energies corresponding to Bragg peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially in annuli with outer radius of 1.0, 2.0, 3.0, 3.2, 3.4, 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model for five different cell types to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. The product of the calculated RBEs and the simulated physical dose was taken to create biological dose and comparisons were then made between the various ions. Results: Transversely, the 10B beam was seen to minimize relative biological dose in both the constant and accelerated dose change regions, proximal to the Bragg Peak, for all beams traveling greater than 50mm. For the 50mm beam, 7Li was seen to provide the most optimal biological dose profile. Radially small fluctuations (<4.2%) were seen in RBE while physical dose was greater than 1% for all beams. Conclusion: Even with the growing usage of 12C, it may not be the most optimal ion in all clinical situations. Boron was calculated to have slightly enhanced RBE characteristics, leading to lower relative biological doses.

60 APPLIED LIFE SCIENCES↗

Bacterial response to the 2021 Orange County, California, oil spill was episodic but subtle relative to natural fluctuations

ABSTRACT An oil spill began in October 2021 off the coast of Orange County, California, releasing 24,696 gallons of crude oil into coastal environments. Although oil spills, such as this one, are recurrent accidents along the California coast, no prior studies have been performed to examine the severity of the local bacterial response. A coastal 10-year time series of short-read metagenomes located within the impacted area allowed us to quantify the magnitude and duration of the disturbance relative to natural fluctuations. We found that the largest change in bacterial beta-diversity occurred at the end of October. The change in taxonomic beta-diversity corresponded with an increase in the sulfur-oxidizing clade Candidatus Thioglobus, an increase in the total relative abundance of potential hydrocarbon-degrading bacteria, and an anomalous decline in the picocyanobacteria Synechococcus . Similarly, changes in function were related to anomalous declines in photosynthetic pathways and anomalous increases in sulfur metabolism pathways as well as aromatic degradation pathways. There was a lagged response in taxonomy and function to peaks in total PAHs. One week after peaks in total PAH concentrations, the largest shifts in taxonomy were observed, and 1 week after the taxonomy shifts were observed, unique functional changes were seen. This response pattern was observed twice during our sampling period, corresponding with the combined effect of resuspended PAHs and increased nutrient concentrations due to physical transport events. Thus, the impact of the spill on bacterial communities was temporally extended and demonstrates the need for continued monitoring for longer than 3 months after initial oil exposure. IMPORTANCE Oil spills are common occurrences in waterways, releasing contaminants into the aquatic environment that persist for long periods of time. Bacterial communities are rapid responders to environmental disturbances, such as oil spills. Within bacterial communities, some members will be susceptible to the disturbance caused by crude oil components and will decline in abundance, whereas others will be opportunistic and will be able to use crude oil components for their metabolism. In many cases, when an oil spill occurs, it is difficult to assess the oil spill’s impact because no samples were collected prior to the accident. Here, we examined the bacterial response to the 2021 Orange County oil spill using a 10-year time series that lies within the impacted area. The results presented here are significant because (i) susceptible and opportunistic taxa to oil spills within the coastal California environment are identified and (ii) the magnitude and duration of the in situ bacterial response is quantified for the first time.

Brock, Melissa L. (ORCID:0000000340329241)↗

Relation between the bond lengths in an O-H-O bridge

The data in the literature on the bond lengths of O-H-O bridges formed in organic and inorganic crystals have been analyzed. The results of generalizations of these data on the basis of the generally accepted relation exp(-(r{sub 1} - r{sub 0}/b) + exp(-(r{sub 2} - r{sub 0}/b) = 1 are considered. The factors limiting its application are revealed and its limiting accuracy is estimated. A more universal expression relating the lengths of the same bonds is proposed: exp(-((r{sub 1} - r{sub 0})/b){sup h}) + exp(-((r{sub 2} - r{sub 0})/b){sup h}) = 1. On the basis of the generalization of all known neutron diffraction data on bridges with angles exceeding 165{sup o}, the coefficients in this relation are determined to be r{sub 0} = 0.950 {+-} 0.005, b = 0.33018 A, and h = 5/3.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Fermi-Pasta-Ulam recurrence and related phenomena for 1D shallow-water waves in a finite basin

Different regimes of the Fermi-Pasta-Ulam (FPU) recurrence are simulated numerically for fully nonlinear 'one-dimensional' potential water waves in a finite-depth flume between two vertical walls. In such systems, the FPU recurrence is closely related to the dynamics of coherent structures approximately corresponding to solitons of the integrable Boussinesq system. A simplest periodic solution of the Boussinesq model, describing a single soliton between the walls, is presented in analytic form in terms of the elliptic Jacobi functions. In the numerical experiments, it is observed that depending on the number of solitons in the flume and their parameters, the FPU recurrence can occur in a simple or complicated manner, or be practically absent. For comparison, the nonlinear dynamics of potential water waves over nonuniform beds is simulated, with initial states taken in the form of several pairs of colliding solitons. With a mild-slope bed profile, a typical phenomenon in the course of evolution is the appearance of relatively high (rogue) waves, while for random, relatively short-correlated bed profiles it is either the appearance of tall waves or the formation of sharp crests at moderate-height waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NSVZ Relation and the Dimensional Reduction in N = 1 SQED

It is known that factorization of the β-function loop integrals into integrals of double total derivatives is an important ingredient needed for deriving the NSVZ relation by direct perturbative calculations in N=1 SQED regularized by thehigher derivatives. It allows to relate the β-function and the anomalous dimension of the matter superfields defined in terms of the bare coupling constant. In this work we find the analog of this result in the case of using dimensional reduction regularization in the lowest orders. However, we demonstrate that in this case the NSVZ relation is not satisfied for the RG functions defined in terms of the bare coupling constant. Nevertheless, it is possible to impose boundary conditions to the renormalization constants determining the NSVZ scheme in the three-loop order for the RG functions defined in terms of the renormalized coupling constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast Search for Dynamic Multi-Relational Graphs

Acting on time-critical events by processing ever growing social media or news streams is a major technical challenge. Many of these data sources can be modeled as multi-relational graphs. Continuous queries or techniques to search for rare events that typically arise in monitoring applications have been studied extensively for relational databases. This work is dedicated to answer the question that emerges naturally: how can we efficiently execute a continuous query on a dynamic graph? This paper presents an exact subgraph search algorithm that exploits the temporal characteristics of representative queries for online news or social media monitoring. The algorithm is based on a novel data structure called the that leverages the structural and semantic characteristics of the underlying multi-relational graph. The paper concludes with extensive experimentation on several real-world datasets that demonstrates the validity of this approach.

Choudhury, Sutanay↗

On the Minimal Length Uncertainty Relation and the Foundations of String Theory

We review our work on the minimal length uncertainty relation as suggested by perturbative string theory. We discuss simple phenomenological implications of the minimal length uncertainty relation and then argue that the combination of the principles of quantum theory and general relativity allow for a dynamical energy-momentum space. We discuss the implication of this for the problem of vacuum energy and the foundations of nonperturbative string theory.

Chang, Lay Nam↗

Relational Blackboard

The Relational Blackboard (RBB) is an extension of the H2 Relational Database to support discrete events and timeseries data. The original motivation for RBB is as a knowledge base for cognitive systems and simulations. It is useful wherever there is a need for persistent storage of timeseries (i.e. samples of a continuous process generating numerical data) and semantic labels for the data. The RBB is an extension to the H2 Relational Database, which is open-source. RBB is a set of stored procedures for H2 allowing data to be labeled, queried, and resampled.

Abbott, RobertG↗

Survival of Snow in the Melting Layer: Relative Humidity Influence

This study quantifies how far snow can fall into the melting layer (ML) before all snow has melted by examining a combination of in-situ observations from aircraft measurements in Lagrangian spiral descents from above through the ML and descents and ascents into the ML, as well as an extensive database of NOAA surface observer reports during the past 50 years. The airborne data contain information on the particle phase (solid, mixed, or liquid), population size distributions and shapes, along with temperature, relative humidity, and vertical velocity. A wide range of temperatures and ambient relative humidities are used for both the airborne and ground-based data. It is shown that an ice bulb temperature of 0°C, together with the air temperature and pressure (altitude), are good first order predictors of the highest temperature snowflakes can survive in the melting layer before completely melting. Particle size is also important, as is whether the particles are graupel or hail. If the relative humidity is too low, the particles will sublimate completely as they fall into the melting layer. Snow as warm as +7°C is observed from aircraft measurements and surface observations. Snow pellets survive to even warmer temperatures. Relationships are developed to represent the primary findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Evaluation of Army Wellness Center Clients’ Health-Related Outcomes

Purpose: To examine whether Army community members participating in a best-practice based workplace health promotion program (WHPP) experience goal-moderated improvements in health-related outcomes. Design: Pretest/posttest outcome evaluation examining an autonomously participating client cohort over 1 year. Setting: Army Wellness Center facilities on 19 Army installations. Participants: Army community members sample (N = 5703), mostly Active Duty Soldiers (64%). Intervention: Assessment of health risks with feedback, health assessments, health education classes, and health coaching sessions conducted by health educators at a recommended frequency of once a month for 3 to 12 months. Measures: Initial and follow-up outcome assessments of body mass index (BMI), body fat, cardiorespiratory fitness, blood pressure, and perceived stress. Analysis: Mixed model linear regression testing for goal-moderated improvements in outcomes. Results: Clients experienced significant improvements in body fat (−2% change), perceived stress (−6% to −12% change), cardiorespiratory fitness (+6% change), and blood pressure (−1% change) regardless of health-related goal. Only clients with a weight loss goal experienced BMI improvement (−1% change). Follow-up outcome assessment rates ranged from 44% (N = 2509) for BMI to 6% (N = 342) for perceived stress. Conclusion: Army Wellness Center clients with at least 1 follow-up outcome assessment experienced improvements in military readiness correlates and chronic disease risk factors. Evaluation design and follow-up-related limitations notwithstanding results suggest that best practices in WHPPs can effectively serve a globally distributed military force.

Rivera, L. Omar↗

COVID-19-Related Experiences and Perspectives of Peruvian College Students: A Descriptive Study

The COVID-19 pandemic drastically affected higher education and higher education students around the world, but few studies of college students’ experiences during the COVID-19 pandemic have been conducted in Latin America. This study describes the COVID-19-related experiences and perspectives of Peruvian college students. We surveyed 3,427 full-time college students (average age: 23 years) attending a multi-campus Peruvian university in fall 2020. Participants were recruited through the digital platform of the learning management system at their university, email, and social media. We asked participants how they were managing risks related to COVID-19; the continuity of social, educational, and work activities; and the psychological and economic impacts of the pandemic on their lives. Since March 2020, 73.0% of participants reported COVID-19-related symptoms, but only 33.9% were tested for COVID-19. During the national quarantine imposed by the Peruvian government (March 15–June 30, 2020), 64.3% of participants remained in their house. Furthermore, while 44.0% of participants were working in February 2020 (95% CI: [41.7%, 46.4%]), only 23.6% (95% CI: [21.7%, 25.7%]) were working immediately after the pandemic began (i.e., at the end of April 2020). Participants were more stressed about the health and educational implications of COVID-19 for Peruvian society and their families than about themselves. The public health, economic, and educational implications of COVID-19 on college students are continuing to unfold. This study informed Peruvian higher education institutions’ continued response to the COVID-19 pandemic, the progressive return to postpandemic activities, as well as other future pandemics and other crises.

Bazo-Alvarez, Juan Carlos↗