Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Results from 2015 and the 2016 upgrade of the CONNIE experiment for detecting coherent neutrino nucleus scattering

The CONNIE Experiment (Coherent Neutrino Nucleus Interaction Experiment) is currently collecting reactor neutrino data to search for the undiscovered standard model process of coherent neutrino-nucleus scattering (CNNS). The detector is composed of a silicon target of thick, fully-depleted, low-noise CCD detectors. Results from data collected in 2015 indicate backgrounds are controlled, and allow an estimate of sensitivity to be presented for a larger scale detector. A 2016 upgrade, adding additional target mass, and reducing readout noise, has been performed, increasing the total yield of signal events by a factor of 30, and already yielding science-quality data. Low-energy nuclear calibrations have been performed, enabling calibration down to the device energy threshold. An estimate of the sensitivity expected for measuring the coherent neutrino process is presented. Future prospects with improved detector energy thresholds are estimated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First data from the CUPID-Mo neutrinoless double beta decay experiment

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $\alpha$ from $\gamma$&$\beta$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $\alpha$ separation of better than 99.9% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0\nu}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid Argon Time Projection Chamber Trigger Development with MicroBooNE

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) neutrino detector at Fermilab that has been operating since 2015. It aims to perform v-Ar cross-section measurements, explore the low-energy excess reported by the MiniBooNE experiment and perform a combined search for sterile neutrino oscillations as part of three LArTPCs that make up the Short Baseline Neutrino (SBN) Program at Fermilab. Since MicroBooNE is currently in an R&D phase, it offers a unique opportunity for the implementation and testing of TPC-based triggers as R&D towards the Deep Underground Neutrino Experiment (DUNE). One of the technical challenges of DUNE that we aim to address with this study is that of efficient self-triggering of a LArTPC utilizing TPC signal information. This capability will enable searches for rare processes in DUNE, such as neutrino interactions from a potential galactic supernova burst. This talk will describe the MicroBooNE TPC readout system and ongoing R&D efforts to develop and demonstrate TPC-based triggering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronization of the 14 kTon NO$\nu$A neutrino detector with the Fermilab NuMI beam

The NOνA experiment is a neutrino oscillation experiment designed to measure parameters related to the neutrino mixing matrix, mass hierarchy and CP violation. The experiment measures neutrino and anti-neutrino interactions from the NuMI beam line at Fermilab in a Near Detector and a Far Detector located 810 kilometers away. Making these measurements requires precise synchronization of 344,064 channels in the Far Detector to an absolute wall time with a channel to channel variation of less then 10 ns. The experiment must correlate the presence of the relatively narrow neutrino beam in the detector with data readout. This paper will discuss the performance of the NOνA timing system during the first few months of operation at the Far Detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Trigger Algorithms to Search for Magnetic Monopoles with the NO$\nu$A Far Detector

The NOvA far detector, due to its surface proximity, large size, good timing resolution, large energy dynamic range, and continuous readout, is sensitive to the detection of magnetic monopoles over a large range of velocities and masses. In order to record candidate magnetic monopole events with high efficiency we have designed a software-based trigger to make decisions based on the data recorded by the detector. The decisions must be fast, have high efficiency, and a large rejection factor for the over 100,000 cosmic rays that course through the detector every second. In this paper we briefly describe the simulation of magnetic monopoles, including the detector response, and then discuss the algorithms applied to identify magnetic monopole candidates. We also present the results of trigger efficiency and purity tests using simulated samples of magnetic monopoles with overlaid cosmic backgrounds and electronic noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NO$\nu$A Far Detector Data Acquisition System

The NOνA experiment is a long-baseline neutrino experiment designed to make measurements to determine the neutrino mass hierarchy, neutrino mixing parameters and CP violation in the neutrino sector. In order to make these measurements the NOνA collaboration has designed a highly distributed, synchronized, continuous digitization and readout system that is able to acquire and correlate data from the Fermilab accelerator complex (NuMI), the NOνA near detector at the Fermilab site and the NOνA far detector which is located 810 km away at Ash River, MN. This system has unique properties that let it fully exploit the physics capabilities of the NOνA detector. The design of the NOνA DAQ system and its capabilities are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress status for the Mu2e calorimeter system

The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NO v A simulation chain

The NO v A experiment is a two-detector, long-baseline neutrino experiment operating in the recently upgraded NuMI muon neutrino beam. Simulating neutrino interactions and backgrounds requires many steps including: the simulation of the neutrino beam flux using FLUKA and the FLUGG interface, cosmic ray generation using CRY, neutrino interaction modeling using GENIE, and a simulation of the energy deposited in the detector using GEANT4. To shorten generation time, the modeling of detector-specific aspects, such as photon transport, detector and electronics noise, and readout electronics, employs custom, parameterized simulation applications. We will describe the NO v A simulation chain, and present details on the techniques used in modeling photon transport near the ends of cells, and in developing a novel data-driven noise simulation. Due to the high intensity of the NuMI beam, the Near Detector samples a high rate of muons originating in the surrounding rock. In addition, due to its location on the surface at Ash River, MN, the Far Detector collects a large rate ((˜) 140 kHz) of cosmic muons. Furthermore, we will discuss the methods used in NO v A for overlaying rock muons and cosmic ray muons with simulated neutrino interactions and show how realistically the final simulation reproduces the preliminary NO v A data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Artificial Retina Processor for Track Reconstruction at the LHC Crossing Rate

The goal of the INFN-RETINA R&D project is to develop and implement a computational methodology that allows to reconstruct events with a large number (> 100) of charged-particle tracks in pixel and silicon strip detectors at 40 MHz, thus matching the requirements for processing LHC events at the full bunch-crossing frequency. Our approach relies on a parallel pattern-recognition algorithm, dubbed artificial retina, inspired by the early stages of image processing by the brain. In order to demonstrate that a track-processing system based on this algorithm is feasible, we built a sizable prototype of a tracking processor tuned to 3 000 patterns, based on already existing readout boards equipped with Altera Stratix III FPGAs. The detailed geometry and charged-particle activity of a large tracking detector currently in operation are used to assess its performances. We report on the test results with such a prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Timing with shower maximum detectors based on pixelated micro-channel plates

Future calorimeters and shower maximum detectors at high luminosity colliders need to be highly radiation resistant and very fast. One exciting option for such a detector is a calorimeter composed of a secondary emitter as the active element. Here, we outline the study and development of a secondary emission calorimeter prototype using micro-channel plates (MCP) as the active element, which directly amplify the electromagnetic shower signal. We also demonstrate the feasibility of using a bare MCP within an inexpensive and robust housing without the need for any photo cathode, which is a key requirement for high radiation tolerance. Test beam measurements of the prototype were performed with 120 GeV primary protons and secondary beams at the Fermilab Test Beam Facility, demonstrating basic calorimetric measurements and precision timing capabilities. Using multiple pixel readout on the MCP, we demonstrate a transverse spatial resolution of 0.8 mm, and time resolution better than 40 ps for electromagnetic showers.

47 OTHER INSTRUMENTATION↗

Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors

Here, we present results of beam tests of charged particle detectors based on single-crystal and poly-crystalline Chemical Vapor Deposition (CVD) diamond. We measured the signal pulse height dependence on the particle flux. The detectors were tested over a range of particle fluxes from 2 kHz/cm 2 to 20 MHz/cm 2 . The pulse height of the sensors was measured with pad and pixel readout electronics. The pulse height of the non-irradiated single-crystal CVD diamond pad sensors was stable with respect to flux, while the pulse height of irradiated single-crystal CVD diamond pad sensors decreased with increasing particle flux. The pulse height of the non-irradiated single-crystal CVD diamond pixel detectors decreased slightly with increasing particle flux while the pulse height of the irradiated single-crystal CVD diamond pixel detectors decreased significantly with increasing particle flux. The observed sensitivity to flux is similar in both the diamond pad sensors constructed using diamonds from the Pixel Luminosity Telescope (PLT) irradiated during its pilot run in the Compact Muon Solenoid (CMS) detector and in neutron irradiated diamond pad sensors from the same manufacturer irradiated to the same fluence of neutrons. The pulse height for irradiated poly-crystalline CVD diamond pad sensors proved to be stable with respect to particle flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-Based Triggering and Reconstruction of Michel Electrons in LArIAT

The LArIAT Experiment aims to calibrate the liquid argon time projection chamber (LArTPC) using a beam of charged particles at the Fermilab Test Beam Facility. It is equipped with a novel scintillation light readout system using PMTs and custom SiPM preamplifier boards to detect light from reflector foils coated with wavelength-shifting TPB. A trigger on delayed secondary flashes of light captures events containing stopping cosmic muons together with the Michel electrons coming from their subsequent decay. This dedicated Michel trigger supplies an abundant sample of low-energy electrons throughout the detector's active volume, providing opportunities to study the combined calorimetric capabilities of the light system and the TPC. Preliminary results using scintillation light to study properties of the Michel electron sample are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a proton Computed Tomography Detector System

Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantegeous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)

The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW(th) nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed around the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The in-situ calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor ON and OFF are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e – RMS and stable background rates. In conclusion, the success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments

The recent development of high-repetition rate x-ray free electron lasers (FEL), makes it possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. We describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS) for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. Furthermore, the signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.

42 ENGINEERING↗

The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Lastly, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗