Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Pulse intensity characterization of the LCLS nanosecond double-bunch mode of operation

The recent demonstration of the 'nanosecond double-bunch' operation mode, i.e. two X-ray pulses separated in time between 0.35 and hundreds of nanoseconds and by increments of 0.35 ns, offers new opportunities to investigate ultrafast dynamics in diverse systems of interest. However, in order to reach its full potential, this mode of operation requires the precise characterization of the intensity of each X-ray pulse within each pulse pair for any time separation. Here, a transmissive single-shot diagnostic that achieves this goal for time separations larger than 0.7 ns with a precision better than 5% is presented. Lastly, it also provides real-time monitoring feedback to help tune the accelerator parameters to deliver double pulse intensity distributions optimized for specific experimental goals.

43 PARTICLE ACCELERATORS↗

Radiation Tolerant Electronics and Digital Processing for the Phase-I Trigger Readout Upgrade of the ATLAS Liquid Argon Calorimeters

The high luminosities of L > 10{sup 34} cm{sup -2}s{sup -1} at the Large Hadron Collider (LHC) at CERN produce an intense radiation environment that the detectors and their electronics must withstand. The ATLAS detector is a multi-purpose apparatus constructed to explore the new particle physics regime opened by the LHC. Of the many decay particles observed by the ATLAS detector, the energy of the created electrons and photons is measured by a sampling calorimeter technique that uses Liquid Argon (LAr) as its active medium. The front end (FE) electronic readout of the ATLAS LAr calorimeter located on the detector itself consists of a combined analog and digital processing system. In order to exploit the higher luminosity while keeping the same trigger bandwidth of 100 kHz, higher transverse granularity, higher resolution and longitudinal shower shape information will be provided from the LAr calorimeter to the Level-l trigger processors. New trigger readout electronics have been designed for this purpose, which will withstand the radiation dose levels expected for an integrated luminosity of 3000 fb{sup -1} during the high luminosity LHC (HL-LHC), which is well above the original LHC design qualifications. (authors)

43 PARTICLE ACCELERATORS↗

Implementation of an ultrasonic instrument for simultaneous mixture and flow analysis of binary gas systems

Precision ultrasonic measurements in binary gas systems provide continuous real-time monitoring of mixture composition and flow. Using custom micro-controller-based electronics, we have developed an ultrasonic instrument, with numerous potential applications, capable of making continuous high-precision sound velocity measurements. The instrument measures sound transit times along two opposite directions aligned parallel to - or obliquely crossing - the gas flow. The difference between the two measured times yields the gas flow rate while their average gives the sound velocity, which can be compared with a sound velocity vs. molar composition look-up table for the binary mixture at a given temperature and pressure. The look-up table may be generated from prior measurements in known mixtures of the two components, from theoretical calculations, or from a combination of the two. We describe the instrument and its performance within numerous applications in the ATLAS experiment at the CERN Large Hadron Collider (LHC). The instrument can be of interest in other areas where continuous in-situ binary gas analysis and flowmetry are required. (authors)

43 PARTICLE ACCELERATORS↗

ATLAS toward the High Luminosity era: challenges on electronic systems

To maximize the physics reach, the Large Hadron Collider (LHC) plans to increase its instantaneous luminosity to $7.5×10^{34} cm^{-2} s^{-1}$ and deliver $3 - 4 ab^{-1}$ of data at a center-of-mass energy of 14 TeV. To profit from this high-luminosity LHC operation with a pile-up up to 200 inelastic collisions per bunch crossing, performance of the ATLAS detector needs to be maintained and in many systems, improved. The upgraded detector will have an unprecedented output data rate of up to 200 TB/s. Real-time processing of this large data volume in a short time period is extremely challenging. New sets of both front-end and back-end electronics are required for all sub-detectors. The large number of detector channels, huge volumes of input and output data, short time available to process and transmit data, harsh radiation environment, and the need of low power consumption all impose great challenges on the designs of electronic systems.

43 PARTICLE ACCELERATORS↗

Tolerance Studies of the Mu2e Solenoid System

The muon-to-electron conversion experiment at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids, namely, the production solenoid, the transport solenoid, and the detector solenoid. Each subsystem has a set of field requirements. Tolerance sensitivity studies of the magnet system were performed with the objective of demonstrating that the present magnet design meets all the field requirements. Systematic and random errors were considered on the position and alignment of the coils. The study helps to identify the critical sources of errors and which are translated to coil manufacturing and mechanical support tolerances.

43 PARTICLE ACCELERATORS↗

Studies on the Magnetic Center of the Mu2e Solenoid System

The definition of the magnetic center in the Mu2e solenoid system is not trivial given the S-shaped nature of the transport solenoid. Moreover, due to the fringe field of the larger bore adjacent magnets-production solenoid and the detector solenoid-the magnetic center does not coincide with the geometric center of the system. The reference magnetic center can be obtained by tracking a low-momentum charged particle through the whole system. This paper will discuss this method and will evaluate the deviations from the nominal magnetic center given the tolerances in the manufacturing and the alignment of the coils. Methods for the correction of the magnetic center will also be presented.

43 PARTICLE ACCELERATORS↗

Torus CLAS12-Superconducting Magnet Quench Analysis

The JLAB Torus magnet system consists of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration. These coils are wound with SSC-36 Nb-Ti superconductor and have the peak magnetic field of 3.6 T. The first coil manufacturing based on the JLAB design began at FNAL. The large magnet system dimensions (8 m diameter and 14 MJ of stored energy) dictate the need for quench protection. Each coil is placed in an aluminum case mounted inside a cryostat and cooled by 4.6 K supercritical helium gas flowing through a copper tube attached to the coil ID. The large coil dimensions and small cryostat thickness drove the design to challenging technical solutions, suggesting that Lorentz forces due to transport currents and eddy currents during quench and various failure scenarios are analyzed. The paper covers the magnet system quench analysis using the OPERA3d Quench code.

Kashikhin, V S↗

Applied metrology in the production of superconducting model magnets for particle accelerators

The production of superconducting magnets for particle accelerators involves high precision assemblies and tight tolerances, in order to achieve the requirements for their appropriate performance. It is therefore essential to have a strict control and traceability over the geometry of each component of the system, and also to be able to compensate possible inherent deviations coming from the production process.

43 PARTICLE ACCELERATORS↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

43 PARTICLE ACCELERATORS↗

Beam test measurements with planar and 3D silicon strip detectors irradiated to sLHC fluences

The planned luminosity upgrade of the CERN LHC to the super LHC (sLHC) requires investigation of new radiation hard tracking detectors. Compared to the LHC, tracking detectors must withstand a 5-10 times higher radiation fluence. Promising radiation hard options are planar silicon detectors with n-side readout and silicon detectors in 3D technology, where columnar electrodes are etched into the silicon substrate. This article presents beam test measurements per formed with planar and 3D n-in-p silicon strip detectors. The detectors were irradiated to different fluences, where the maximum fluence was 3 x 10{sup 15} 1 MeV neutron equivalent particles per square centimeter (n{sub eq}/cm{sup 2}) for the planar detectors and 2 x 10{sup 15} n{sub eq}/cm{sup 2} for the 3D detectors. In addition to signal measurements, charge sharing and resolution of both detector technologies are compared. An increased signal from the irradiated 3D detectors at high bias voltages compared to the signal from the unirradiated detector indicates that charge multiplication effects occur in the 3D detectors. At a bias voltage of 260 V, the 3D detector irradiated to 2 x 10{sup 15} n{sub eq}/cm{sup 2} yields a signal almost twice as high as the signal of the unirradiated detector. Only 30% of the signal of an unirradiated detector could be measured with the planar detector irradiated to 3 x 10{sup 15} n{sub eq}/cm{sup 2} at a bias voltage of 600 V, which was the highest bias voltage applied to this sensor.

43 PARTICLE ACCELERATORS↗

A Spin-Light Polarimeter for Multi-GeV Longitudinally Polarized Electron Beams

The physics program at the upgraded Jefferson Lab (JLab) and the physics program envisioned for the proposed electron-ion collider (EIC) include large efforts to search for interactions beyond the Standard Model (SM) using parity violation in electroweak interactions. These experiments need precision electron polarimetry with an uncertainty of <; 0.5 %. The spin dependent Synchrotron radiation, called "spin-light," can be used to monitor the electron beam polarization. Here, we develop a conceptual design for a "spin-light" polarimeter that can be used at a high intensity, multi-GeV electron accelerator. We have also built a Geant4 based simulation for a prototype device and report some of the results from these simulations

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving Longitudinal Impedance of Inductive Inserts

In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.

43 PARTICLE ACCELERATORS↗

In situ baking method for degassing of a kicker magnet in accelerator beam line

In this study, the authors propose a new in situ degassing method by which only kicker magnets in the accelerator beam line are baked out without raising the temperature of the vacuum chamber to prevent unwanted thermal expansion of the chamber. By simply installing the heater and thermal radiation shield plates between the kicker magnet and the chamber wall, most of the heat flux from the heater directs toward the kicker magnet. The result of the verification test showed that each part of the kicker magnet was heated to above the target temperature with a small rise in the vacuum chamber temperature. A graphite heater was selected in this application to bake-out the kicker magnet in the beam line to ensure reliability and easy maintainability of the heater. The vacuum characteristics of graphite were suitable for heater operation in the beam line. A preliminary heat-up test conducted in the accelerator beam line also showed that each part of the kicker magnet was successfully heated and that thermal expansion of the chamber was negligibly small.

43 PARTICLE ACCELERATORS↗

Application of cyclotrons in beam technologies

Some currently developed applications of cyclotrons (beam technologies) are discussed. They include new methods for producing radioisotopes for medical purposes and investigations into the radiation strength ofmaterials and the wear of units of variousmachines and devices bymeans of beams of radioactive nuclei.

43 PARTICLE ACCELERATORS↗

Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

43 PARTICLE ACCELERATORS↗

Conical Mirror Energy-Analyzer

Electron optical properties of an axisymmetric mirror energy-analyzer are studied. The internal electrode represents a cylinder, and the external electrode is formed by two identical cones with common bases. It is shown that the relative aperture and resolution of such an analyzer are significantly greater than the corresponding parameters of a conventional cylindrical mirror. The internal electrode is made of three cylinders with different diameters, and the potentials of the cylinders are identical. Such a structure is used to further improve electron optical characteristics of the conical analyzer. At a relatively small beam angle, the resolution of the conical analyzer is two times greater than the resolution of the cylindrical mirror, and the difference of the resolutions amounts to an order of magnitude when the beam angle increases.

43 PARTICLE ACCELERATORS↗

The ATLAS Inner Detector commissioning and calibration

The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7. 6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1±0.9 μm and a relative momentum resolution σ p /p=(4. 83 ± 0.16)×10 -4 GeV -1 ×p T have been measured for high momentum tracks.

43 PARTICLE ACCELERATORS↗

First particle-by-particle measurement of emittance in the Muon Ionization Cooling Experiment

The Muon Ionization Cooling Experiment (MICE) collaboration seeks to demonstrate the feasibility of ionization cooling, the technique by which it is proposed to cool the muon beam at a future neutrino factory or muon collider. The emittance is measured from an ensemble of muons assembled from those that pass through the experiment. A pure muon ensemble is selected using a particle-identification system that can reject efficiently both pions and electrons. The position and momentum of each muon are measured using a high-precision scintillating-fibre tracker in a 4 T solenoidal magnetic field. This paper presents the techniques used to reconstruct the phase-space distributions in the upstream tracking detector and reports the first particle-by-particle measurement of the emittance of the MICE Muon Beam as a function of muon-beam momentum.

43 PARTICLE ACCELERATORS↗