Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Hard-X-Ray Phase-Difference Microscopy Using a Fresnel Zone Plate and a Transmission Grating

Novel hard x-ray phase imaging microscopy that simply uses an objective and a transmission grating is described. The microscope generated an image that exhibited twin features of a sample with an opposite phase contrast having a separation of a specific distance. Furthermore, the twin features were processed to generate an image mapping the x-ray phase shift through a simple algorithm. The presence of the grating did not degrade the spatial resolution of the microscope. The sensitivity of our microscope to light elements was about 2 orders of magnitude higher than that of the absorption contrast microscope that was attained by simply removing the grating. Our method is attractive for easily appending a quantitative phase-sensitive mode to normal x-ray microscopies, and it has potentially broad applications in biology and material sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sudden-Discharge Cycling Characteristics and Millisecond Dynamic Behaviors of a HTS Stainless-Steel Insulated Double-Pancake Coil With Thin Copper Plates

We have tested an intermediate-sized HTS stainless-steel (co-wound) insulated double pancake coil (~132 turns per coil) and discovered dynamic effects during sudden discharge on both millisecond and second scales. For soft break, the power supply is turned off suddenly but the shunt resistor (164 milliohm) is still connected; for hard break, a high voltage contactor is used to suddenly open the circuit so that the leads are completely open. Hard break is dangerous to traditionally insulated LTS magnets, but the SS-insulated HTS DPC retained integrity over ¡80 charge-discharge cycles. Voltage decay curves for soft and hard breaks are studied on short and long timescales. On long timescales, we observe the expected exponential decay and measure the time constant to calculate contact resistance. On short timescales, we observe highly dynamic effects: a hyper-exponential decay suggesting that the inductance or contact resistance is suddenly changing with time, likely an indication of the RL circuit forming. Moreover, peak voltage immediately (ms) after the sudden discharge were collected and compared. It is found that the peak voltage in soft-discharge is proportional to the applied current, while the those in hard-break has a unique pattern and tends to stay flat even though the applied current increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Multiphase Modeling in a Parallel Plate Fluidized Bed Receiver for Concentrating Solar Power

A novel high temperature particle solar receiver is developed by using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a packed bed at the lower end, leaving the system from the bottom at a constant flow rate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built and a near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2K.

CSP↗

Field-size effect of physical doses in carbon-ion scanning using range shifter plates

A field-size effect of physical doses was studied in scanning irradiation with carbon ions. For the target volumes of 60x60x80, 40x40x80, and 20x20x80 mm{sup 3}, the doses along the beam axis within the spread-out Bragg peaks reduced to 99.4%, 98.2%, and 96.0% of the dose for the target of 80x80x80 mm{sup 3}, respectively. The present study revealed that the observed reductions can be compensated for by adopting the three-Gaussian form of lateral dose distributions for the pencil beam model used in the treatment planning system. The parameters describing the form were determined through the irradiation experiments making flat concentric squared frames with a scanned carbon beam. Since utilizing the three-Gaussian model in the dose optimization loop is at present time consuming, the correction for the field-size effect should be implemented as a ''predicted-dose scaling factor.'' The validity of this correction method was confirmed through the irradiation of a target of 20x20x80 mm{sup 3}.

61 RADIATION PROTECTION AND DOSIMETRY↗