Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Rotorcraft system identification techniques for handling qualities and stability and control evaluation

An integrated approach to rotorcraft system identification is described. This approach consists of sequential application of (1) data filtering to estimate states of the system and sensor errors, (2) model structure estimation to isolate significant model effects, and (3) parameter identification to quantify the coefficient of the model. An input design algorithm is described which can be used to design control inputs which maximize parameter estimation accuracy. Details of each aspect of the rotorcraft identification approach are given. Examples of both simulated and actual flight data processing are given to illustrate each phase of processing. The procedure is shown to provide means of calibrating sensor errors in flight data, quantifying high order state variable models from the flight data, and consequently computing related stability and control design models.

Hall, W. E., Jr.↗

Training models using forces computed by stochastic electronic structure methods

Abstract Quantum Monte Carlo (QMC) can play a very important role in generating accurate data needed for constructing potential energy surfaces. We argue that QMC has advantages in terms of a smaller systematic bias and an ability to cover phase space more completely. The stochastic noise can ease the training of the machine learning model. We discuss how stochastic errors affect the generation of effective models by analyzing the errors within a linear least squares procedure, finding that there is an advantage to having many relatively imprecise data points for constructing models. We then analyze the effect of noise on a model of many-body silicon finding that noise in some situations improves the resulting model. We then study the effect of QMC noise on two machine learning models of dense hydrogen used in a recent study of its phase diagram. The noise enables us to estimate the errors in the model. We conclude with a discussion of future research problems.

Ceperley, David M. (ORCID:0000000150826271)↗

A method to evaluate dose errors introduced by dose mapping processes for mass conserving deformations

Purpose: To present a method to evaluate the dose mapping error introduced by the dose mapping process. In addition, apply the method to evaluate the dose mapping error introduced by the 4D dose calculation process implemented in a research version of commercial treatment planning system for a patient case. Methods: The average dose accumulated in a finite volume should be unchanged when the dose delivered to one anatomic instance of that volume is mapped to a different anatomic instance--provided that the tissue deformation between the anatomic instances is mass conserving. The average dose to a finite volume on image S is defined as d{sub S}=e{sub s}/m{sub S}, where e{sub S} is the energy deposited in the mass m{sub S} contained in the volume. Since mass and energy should be conserved, when d{sub S} is mapped to an image R(d{sub S{yields}R}=d{sub R}), the mean dose mapping error is defined as {Delta}d{sub m}=|d{sub R}-d{sub S}|=|e{sub R}/m{sub R}-e{sub S}/m{sub S}|, where the e{sub R} and e{sub S} are integral doses (energy deposited), and m{sub R} and m{sub S} are the masses within the region of interest (ROI) on image R and the corresponding ROI on image S, where R and S are the two anatomic instances from the same patient. Alternatively, application of simple differential propagation yields the differential dose mapping error, {Delta}d{sub d}=|({partial_derivative}d/{partial_derivative}e)*{Delta}e+({partial_derivative}d/{partial_derivative}m)*{Delta}m|=|((e{sub S}-e{sub R})/m{sub R})-((m{sub S}-m{sub R})/m{sub R}{sup 2})*e{sub R}|={alpha}|d{sub R}-d{sub S}| with {alpha}=m{sub S}/m{sub R}. A 4D treatment plan on a ten-phase 4D-CT lung patient is used to demonstrate the dose mapping error evaluations for a patient case, in which the accumulated dose, D{sub R}={Sigma}{sub S=0}{sup 9}d{sub S{yields}R}, and associated error values ({Delta}D{sub m} and {Delta}D{sub d}) are calculated for a uniformly spaced set of ROIs. Results: For the single sample patient dose distribution, the average accumulated differential dose mapping error is 4.3%, the average absolute differential dose mapping error is 10.8%, and the average accumulated mean dose mapping error is 5.0%. Accumulated differential dose mapping errors within the gross tumor volume (GTV) and planning target volume (PTV) are lower, 0.73% and 2.33%, respectively. Conclusions: A method has been presented to evaluate the dose mapping error introduced by the dose mapping process. This method has been applied to evaluate the 4D dose calculation process implemented in a commercial treatment planning system. The method could potentially be developed as a fully-automatic QA method in image guided adaptive radiation therapy (IGART).

61 RADIATION PROTECTION AND DOSIMETRY↗

Four-Dimensional Measurement of the Displacement of Internal Fiducial and Skin Markers During 320-Multislice Computed Tomography Scanning of Breast Cancer

Purpose: To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. Methods and Materials: This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Results: Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 {+-} 0.3 mm, 2.1 {+-} 0.6 mm, and 1.6 {+-} 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 {+-} 0.2 mm in left-right, 1.7 {+-} 0.5 mm in A/P, and 1.1 {+-} 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Conclusions: Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase measurement device using inphase and quadrature components for phase estimation

A phasemeter for estimating the phase of a signal. For multi-tone signals, multiple phase estimates may be provided. An embodiment includes components operating in the digital domain, where a sampled input signal is multiplied by cosine and sine terms to provide estimates of the inphase and quadrature components. The quadrature component provides an error signal that is provided to a feedback loop, the feedback loop providing a model phase that tends to track the phase of a tone in the input signal. The cosine and sine terms are generated from the model phase. The inphase and quadrature components are used to form a residual phase, which is added to the model phase to provide an estimate of the phase of the input signal. Other embodiments are described and claimed.

Halverson, Peter G.↗

Astrometry of OH/IR Stars Using 1612 MHz Hydroxyl Masers. I. Annual Parallaxes of WX Psc and OH138.0+7.2

We report on the measurement of the trigonometric parallaxes of 1612 MHz hydroxyl masers around two asymptotic giant branch stars, WX Psc and OH 138.0+7.2, using the NRAO Very Long Baseline Array with in-beam phase referencing calibration. We obtain a 3σ upper limit of ≤5.3 mas on the parallax of WX Psc, corresponding to a lower limit distance estimate of ≳190 pc. The obtained parallax of OH 138.0+7.2 is 0.52 ± 0.09 mas (±18%), corresponding to a distance of 1.9{sub −0.3}{sup +0.4} kpc, making this the first hydroxyl maser parallax below one milliarcsecond. We also introduce a new method of error analysis for detecting systematic errors in the astrometry. Finally, we compare our trigonometric distances to published phase-lag distances toward these stars and find a good agreement between the two methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed quantum sensing enhanced by continuous-variable error correction

Abstract A distributed sensing protocol uses a network of local sensing nodes to estimate a global feature of the network, such as a weighted average of locally detectable parameters. In the noiseless case, continuous-variable (CV) multipartite entanglement shared by the nodes can improve the precision of parameter estimation relative to the precision attainable by a network without shared entanglement; for an entangled protocol, the root mean square estimation error scales like 1/ M with the number M of sensing nodes, the so-called Heisenberg scaling, while for protocols without entanglement, the error scales like 1 / M . However, in the presence of loss and other noise sources, although multipartite entanglement still has some advantages for sensing displacements and phases, the scaling of the precision with M is less favorable. In this paper, we show that using CV error correction codes can enhance the robustness of sensing protocols against imperfections and reinstate Heisenberg scaling up to moderate values of M . Furthermore, while previous distributed sensing protocols could measure only a single quadrature, we construct a protocol in which both quadratures can be sensed simultaneously. Our work demonstrates the value of CV error correction codes in realistic sensing scenarios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time determination for spacecraft users of the Navstar Global Positioning System /GPS/

Global Positioning System (GPS) navigation is performed by time measurements. A description is presented of a two body model of spacecraft motion. Orbit determination is the process of inferring the position, velocity, and clock offset of the user from measurements made of the user motion in the Newtonian coordinate system. To illustrate the effect of clock errors and the accuracy with which the user spacecraft time and orbit may be determined, a low-earth-orbit spacecraft (Seasat) as tracked by six Phase I GPS space vehicles is considered. The obtained results indicate that in the absence of unmodeled dynamic parameter errors clock biases may be determined to the nanosecond level. There is, however, a high correlation between the clock bias and the uncertainty in the gravitational parameter GM, i.e., the product of the universal gravitational constant and the total mass of the earth. It is, therefore, not possible to determine clock bias to better than 25 nanosecond accuracy in the presence of a gravitational error of one part per million.

Grenchik, T. J.↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microsegregation Measurement: Methods and Applications

Microsegregation is chemical variation at the microstructural level in a solidified ingot, which can cause undesirable effects on material properties. Its formation is driven by different levels of solute elemental solubility between solid and liquid phases, resulting in solute buildup or depletion in the liquid phase during solidification. Characterization of microsegregation can be essential for understanding its formation and removing it through heat treatment. Measurement is frequently carried out via scanning electron microscope (SEM), though metallographic analysis, mechanical testing and optical radiography have been used. SEM analysis can consist of point measurements on single dendrites, line scans across or along dendrites, elemental maps, and extended line-based or grid-based analyses extending over many dendrites, which can generate large amounts of data. Line-based or grid-based data can be analyzed using scatterplots of element concentrations to visualize segregation behavior and sorting/ranking of data by a single element or a combination of elements, to give compositional profiles as a function of extent of solidification. For both qualitative and quantitative analyses, effects of phase transformations and secondary phases need to be considered as well as sorting of measurement errors when generating compositional profiles. Applications of analysis include determination of partition ratios, examination of solute–element interactions, determination of effects of cooling rate and back diffusion, applications to freckling studies, validations of modeling, and development of heat-treatment profiles.

36 MATERIALS SCIENCE↗

Fault-tolerant grid frequency measurement algorithm during transients

Many critical electric grid operations rely on accurate grid frequency measurements. Unfortunately, the measurement accuracy can be easily undermined by power system transient faults. During a power system transient fault, the power grid voltages and currents are usually highly distorted by high-frequency components. What is worse, the power grid signals could have discontinuity during some system transient faults such as phase angle jump, and the discontinuity could result in large measurement errors to state-of-the-art grid measurement algorithms. In this study, a fault-tolerant grid frequency measurement algorithm during transients is proposed. The new algorithm consists of two stages. The first stage is a transient detector, and it can detect the occurrence of system transient faults instantaneously. The second stage is the intelligent frequency estimator, and it will adapt its measurements according to the transient detector. The performance of the algorithm is evaluated under different steady-state and transient conditions. Both dependability and security of the fault-tolerant algorithm are assessed by using PSCAD simulation data and IEEE Standard test data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

The DESI N -body simulation project – I. Testing the robustness of simulations for the DESI dark time survey

ABSTRACT Analysis of large galaxy surveys requires confidence in the robustness of numerical simulation methods. The simulations are used to construct mock galaxy catalogues to validate data analysis pipelines and identify potential systematics. We compare three N-body simulation codes, abacus, gadget-2, and swift, to investigate the regimes in which their results agree. We run N-body simulations at three different mass resolutions, 6.25 × 108, 2.11 × 109, and 5.00 × 109 h−1 M⊙, matching phases to reduce the noise within the comparisons. We find systematic errors in the halo clustering between different codes are smaller than the Dark Energy Spectroscopic Instrument (DESI) statistical error for $s\ \gt\ 20\ h^{-1}$ Mpc in the correlation function in redshift space. Through the resolution comparison we find that simulations run with a mass resolution of 2.1 × 109 h−1 M⊙ are sufficiently converged for systematic effects in the halo clustering to be smaller than the DESI statistical error at scales larger than $20\ h^{-1}$ Mpc. These findings show that the simulations are robust for extracting cosmological information from large scales which is the key goal of the DESI survey. Comparing matter power spectra, we find the codes agree to within 1 per cent for k ≤ 10 h Mpc−1. We also run a comparison of three initial condition generation codes and find good agreement. In addition, we include a quasi-N-body code, FastPM, since we plan use it for certain DESI analyses. The impact of the halo definition and galaxy–halo relation will be presented in a follow-up study.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying Uncertainties In Neutron-Alpha Scattering With Chiral Nucleon-Nucleon And Three-Nucleon Forces

We report that modern ab initio theory combined with high-quality nucleon-nucleon (NN) and three-nucleon (3N) interactions from chiral effective field theory (EFT) can provide a predictive description of low-energy light-nuclei reactions relevant for astrophysics and fusion-energy applications. However, the high cost of computations has so far impeded a complete analysis of the uncertainty budget of such calculations. Starting from NN potentials up to fifth order (N 4 LO) combined with leading-order 3N forces, we study how the order-by-order convergence of the chiral expansion and confidence intervals for the 3N contact and contact-plus-one-pion-exchange low-energy constants (c E and c D ) contribute to the overall uncertainty budget of many-body calculations of neutron- 4 He (n-α) elastic scattering. We compute structure and reaction observables for three-, four-, and five-nucleon systems within the ab initio frameworks of the no-core shell model and no-core shell model with continuum. Using a small set of design runs, we construct a Gaussian process model (GPM) that acts as a statistical emulator for the theory. With this, we gain insight into how uncertainties in the 3N low-energy constants propagate throughout the calculation and determine the Bayesian posterior distribution of these parameters with Markov-Chain Monte Carlo. We find rapidly converging n-α phase shifts with respect to the chiral order. With the adopted leading-order 3N force, calculations based on the NN interaction at N 4 LO of Entem, Machleidt, and Nosyk are unable to reproduce the experimental phase shifts in the 3/2 - channel within the estimated chiral truncation errors. Closer agreement with empirical data is found when using an older parametrization of the NN interaction at order N 3 LO, and the position and width of the P-wave resonances can be used to reduce the uncertainty of the 3N low-energy constants. The present results point to a lack of spin-orbit strength when the newer parametrization of the chiral NN force up to fifth order is combined with the leading-order 3N force. The inclusion of higher-order 3N-force terms may be required to recover the missing strength. GPMs can act as fast and accurate emulators of ab initio many-body calculations of low-energy scattering and reactions of light nuclei, opening the way to a robust quantification of theoretical uncertainties grounded in the description of the underlying chiral Hamiltonian.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Entropy uncertainty relations and stability of phase-temporal quantum cryptography with finite-length transmitted strings

Any key-generation session contains a finite number of quantum-state messages, and it is there-fore important to understand the fundamental restrictions imposed on the minimal length of a string required to obtain a secret key with a specified length. The entropy uncertainty relations for smooth min and max entropies considerably simplify and shorten the proof of security. A proof of security of quantum key distribution with phase-temporal encryption is presented. This protocol provides the maximum critical error compared to other protocols up to which secure key distribution is guaranteed. In addition, unlike other basic protocols (of the BB84 type), which are vulnerable with respect to an attack by 'blinding' of avalanche photodetectors, this protocol is stable with respect to such an attack and guarantees key security.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cloud Influence on ERA5 and AMPS Surface Downwelling Longwave Radiation Biases in West Antarctica

The surface downwelling longwave radiation component (LW?) is crucial for the determination of the surface energy budget and has significant implications for the resilience of ice surfaces in the polar regions. Accurate model evaluation of this radiation component requires knowledge about the phase, vertical distribution, and associated temperature of water in the atmosphere, all of which control the LW? signal measured at the surface. In this study, we examine the LW? model errors found in the Antarctic Mesoscale Prediction System (AMPS) operational forecast model and the ERA5 reanalysis model relative to observations from the AWARE campaign at McMurdo Station and the West Antarctic Ice Sheet (WAIS) Divide. The errors are calculated separately for observed clear sky conditions, ice cloud occurrences, and liquid-bearing cloud layer (LBCL) occurrences. The analysis results show a tendency (in both models at each site) to underestimate the LW? during clear sky conditions, high error variability (standard deviations > 20 W/m2) during any type of cloud occurrence, and negative LW? biases when LBCLs are observed (bias magnitudes > 15 W/m2 in tenuous LBCL cases; > 43 W/m2 in optically thick/opaque LBCLs instances). We suggest that a generally dry and liquid water-deficient atmosphere responsible for the identified LW? biases in both models is the result of excessive ice formation and growth, which could stem from model initial and lateral boundary conditions, microphysics scheme, aerosol representation, and/or limited vertical resolution.

Silber, Israel↗

Single-shot high-resolution characterization of optical pulses by spectral phase diversity

The concept of spectral phase diversity is proposed and applied to the temporal characterization of optical pulses. The experimental trace is composed of the measured power of a plurality of ancillary optical pulses derived from the pulse under test by adding known amounts of chromatic dispersion. The spectral phase of the pulse under test is retrieved by minimizing the error between the experimental trace and a trace calculated from the optical spectrum using the known diagnostic parameters. An assembly composed of splitters and dispersive delay fibers has been used to generate 64 ancillary pulses whose instantaneous power can be detected in a single shot with a high-bandwidth photodiode and oscilloscope. Pulse-shape reconstruction for pulses shorter than the photodetection impulse response has been demonstrated.The diagnostic is experimentally shown to accurately characterize pulses from a chirped-pulse–amplification system when its stretcher is detuned from the position for optimal recompression. As a result, various investigations of the performance with respect to the number of ancillary pulses and the range of chromatic dispersion generated in the diagnostic are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗