Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Optimizing the impacts of solid additives on the operational stability and processing reliability of organic solar cells

Previous reports have revealed that by leveraging solid additives, organic solar cells (OSCs) can surpass the device’s performance beyond the intrinsic limitations of host photoactive molecules, a remarkable advancement. However, the impacts of more complex interactions introduced by solid additives are not yet well understood. Herein, optimizing the fabrication process based on the traditional efficiency-guided approach fails to represent the ideal and most practical devices. In particular, achieving superior operational stability while minimizing the device performance scattering was found to require processing solvent evaporation to be synchronized with the volatility of the chosen solid additive. However, this may be challenging since most organic photoactive materials display excellent efficiencies only with selected solvents. Accordingly, this work also demonstrates the potential of dual and complementary solvents selection, consisting of low boiling point (primary) and high boiling point (secondary). This strategy allows for the suppression of any potential trade-offs in efficiency. Meanwhile, the operational stability and precision of device performance are substantially enhanced. Additionally, solid additives have demonstrated that the singlet exciton dissociation rate does not limit the free charge generation yield. Finally, these findings are expected to reformulate OSC device fabrication strategies towards more practical devices.

36 MATERIALS SCIENCE↗

Assessment of the Effect of Prototypic High-Burnup Operating Conditions of Fuel Fragmentation, Relocation, and Dispersal Susceptibility

The US nuclear energy industry is investigating strategies that further reduce the cost of energy production by using its existing fleet of nuclear generating stations. Most nuclear power plant operating costs are associated with purchasing fresh fuel assemblies or the efficiency of the reactor core design. Material costs are typically beyond the operator’s control; however, the core design optimizations offer potential operational savings. The core design envelope available to operators is constrained by two primary regulatory criteria: an enrichment limit of 5% 235 U and a burnup limit of 62 GWD/tU. These constraints have resulted in renewed efforts by the nuclear industry to pursue extending the peak rod-average burnup beyond 62 GWd/tU. This effort will likely require additional safety analyses beyond what is currently accepted by the US Nuclear Regulatory Commission. The purpose of this work is to demonstrate a best estimate plus uncertainty pin-by-pin high-burnup loss of coolant accident analysis technique to assess full-core high-burnup fuel fragmentation, relocation, and dispersal (FFRD) and identify approaches for minimizing or potentially mitigating FFRD through core design optimizations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Best Practices in PEC Water Splitting: How to Reliably Measure Solar-to-Hydrogen Efficiency of Photoelectrodes

Photoelectrochemical (PEC) water splitting, which utilizes sunlight and water to produce hydrogen fuel, is potentially one of the most sustainable routes to clean energy. One challenge to success is that, to date, similar materials and devices measured in different labs or by different operators lead to quantitatively different results, due to the lack of accepted standard operating procedures and established protocols for PEC efficiency testing. With the aim of disseminating good practices within the PEC community, we provide a vetted protocol that describes how to prepare integrated components and accurately measure their solar-to-hydrogen (STH) efficiency (η STH ). This protocol provides details on electrode fabrication, η STH test device assembly, light source calibration, hydrogen evolution measurement, and initial material qualification by photocurrent measurements under monochromatic and broadband illumination. Common pitfalls in translating experimental results from any lab to an accurate STH efficiency under an AM1.5G reference spectrum are discussed. A III–V tandem photocathode is used to exemplify the process, though with small modifications, the protocol can be applied to photoanodes as well. Dissemination of PEC best practices will help those approaching the field and provide guidance for comparing the results obtained at different lab sites by different groups.

08 HYDROGEN↗

Durable Fuel Cell MEA through Immobilization of Catalyst Particle and Membrane Chemical Stabilizer

For hydrogen-based fuel cell electric vehicle to be cost competitive with the incumbent diesel-powered internal combustion engine heavy-duty vehicle, the total cost of ownership of the truck must be decreased via both capital cost and the operating cost (H 2 fuel expense) reduction. This puts the emphasis on the decrease of fuel cell stack cost via use of low platinum catalyst material usage to decrease capital cost, high H 2 fuel efficiency and high stack durability to decrease the operating cost. US DOE has set a target of ≤ 0.25 mgPt/cm 2 total loading in the membrane electrode assembly, high fuel efficiency of > 68% and a HD-combined target of ≥ 2.5 kW/gPGM after running an accelerated stress test (AST) equivalent to 30,000 hours of heavy-duty fuel cell operation.

08 HYDROGEN↗

Enhanced carbon-transfer and -utilization efficiencies achieved using membrane carbonation with gas sources having a range of CO 2 concentrations

The economic viability of microalgal biofuels relies on increasing productivity in a cost-effective manner. As microalgal biomass contains > 50% carbon, a high rate of CO 2 delivery is required for high productivity, and inefficient CO 2 delivery amplifies operating costs. Membrane carbonation using non-porous hollow fiber membranes can ideally deliver CO 2 without bubble formation and high carbon transfer efficiency. Because CO 2 streams from industrial resources are not 100% CO 2 , the buildup of inert gasses can significantly lower the CO 2 delivery rate when the distal end of the membrane is closed. To overcome the buildup of inert gases, we managed the distal end of the membranes with three different approaches: fully open end, restricted bleed valve, and restricted bleed valve with pH-actuated venting. For all approaches, CO 2 was delivered to membranes ondemand based on a pH set point. Evaluating a wide range of CO 2 concentrations (10% to 100%), we found that all approaches eliminated the buildup of inert gases, could maintain target pH values and gave the same biomass productivities and carbon distributions. However, carbon transfer efficiency depended on the operation of the distal end. Fully open-end operation gave a poor carbon transfer efficiency because of excessive loss of CO 2 from the distal end. However, restricting the exit flow rate to ≤4 cm 3 /min mitigated the problems of excessive CO 2 loss, but without incurring a large loss of CO 2 -delivery flux. For the continuous cultivation, combining a restricted bleed valve with pH-actuated venting improved the carbon-transfer efficiency and -utilization efficiencies up to 85% and 67%, respectively, with a sufficient CO 2 delivery flux.

42 ENGINEERING↗

Development of Advanced Ultra-Supercritical (AUSC) Pulverized Coal (PC) Plants

This report presents an independent assessment of pulverized coal (PC) power plants operating at advanced ultrasupercritical (AUSC) steam conditions. At AUSC conditions, PC plants generate electricity at higher efficiencies and with lower carbon footprints than PC plants operating at subcritical, supercritical (SC), and ultrasupercritical (USC) steam conditions, such as those examined in previous National Energy Technology Laboratory (NETL) reports. However, advanced materials are required for commercial operation under these AUSC steam conditions which impact plant economics. In 2001, the United States (U.S.) Department of Energy (DOE) with the Ohio Coal Development Office launched a research program carried out by a consortium of industry and research organizations (the AUSC Consortium) to develop the materials necessary to commercially demonstrate AUSC technology. The results contained in this report incorporate findings by the AUSC Consortium.

01 COAL, LIGNITE, AND PEAT↗

Influence of design and operating parameters for additively manufactured intensified packing devices on CO 2 -Absorption column cooling and capture efficiency

Solvent-based CO 2 absorption is technologically a matured CO 2 capture pathway but suffers from: high regeneration energy demand, and solvent temperature rise and decreased capture efficiency caused by the heat of reaction. While research has focused on developing non-aqueous and low-aqueous solvents for decreasing the regeneration energy, the temperature bulge due to exothermic absorption is typically dealt with by cooling the solvent with an external inter-stage heat-exchanger. This approach may increase the overall process footprint, as well as capital and operating costs. Here, the current study explores a process intensification approach by incorporating inside the column an additively manufactured intensified packing device that consists of corrugated plates and internal coolant channels. The corrugated plates provide surface area for mass transfer between gas and liquid, while cooling fluid inside the internal channels removes heat from the exothermic reactive system. Two different intensified devices with specific surface areas of 266 m 2 /m 3 and 359 m 2 /m 3 were designed, manufactured, and tested inside a 2.06-m long and 0.203-m diameter column packed with commercial Mellapak 250Y packing. The device with a lower surface area showed up to 27 % reduction in cooling performance. A steady-state heat transfer model provides good agreement with the experimental column temperature and intra-stage heat removal data. Although a decrease in heat transfer performance was observed for the device with lower surface area, CO 2 capture experiments performed with simulated flue gas and low-aqueous solvent demonstrated that both intensified devices lead to a similar improvement of 12 % in capture efficiency. This study provides an understanding on simplifying the intensified packing device geometry and decreasing the device fabrication cost by 25 % without compromising with the CO 2 absorption performance of the packed column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lead-Free Flexible Perovskite Solar Cells with Interfacial Native Oxide Have >10% Efficiency and Simultaneously Enhanced Stability and Reliability

Here we demonstrate an innovative compositional and interfacial engineering approach to achieve Pb-free flexible perovskite solar cells (f-PSCs) with an unprecedented combination of the highest efficiency reported to date (10.43%), together with enhanced operational stability and mechanical reliability. The key to this approach is alloying of an FASnI3 metal halide perovskite (MHP) thin film with Ge2+ to stabilize the Sn2+ oxidation state in the MHP, together with the use of a NiOx hole-transport layer. We show that this results in the in situ formation of a thin amorphous GeO2 native oxide layer at the NiOx/FASn0.9Ge0.1I3 interface. This layer not only passivates that critical interface but also enhances the interfacial mechanical bonding.

efficiency↗

Optimizing Perovskite Thin‐Film Parameter Spaces with Machine Learning‐Guided Robotic Platform for High‐Performance Perovskite Solar Cells

Abstract Simultaneously optimizing the processing parameters of functional thin films remains a challenge. The design and utilization of a fully automated platform called SPINBOT is presented for the engineering of solution‐processed functional thin films. The SPINBOT is capable of performing experiments with high sampling variability through the unsupervised processing of hundreds of substrates with exceptional experimental control. Through the iterative optimization process enabled by the Bayesian optimization (BO) algorithm, the SPINBOT explores an intricate parameter space, continuously improving the quality and reproducibility of the produced thin films. This machine learning (ML)‐guided reliable SPINBOT platform enables the acceleration of the optimization process of perovskite solar cells via a simple photoluminescence characterization of films. As a result, this study arrives at an optimal film that, when processed into a solar cell in an ambient atmosphere, immediately yields a champion power conversion efficiency (PCE) of 21.6% with satisfactory performance reproducibility. The unsealed devices retain 90% of their initial efficiency after 1100 h of continuous operation at 60–65 °C under metal‐halide lamps. It is anticipated that the integration of robotic platforms with the intelligent algorithm will facilitate the widespread adoption of effective autonomous experimentation to address the evolving needs and constraints within the materials science research community.

14 SOLAR ENERGY↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

High-performance photonic transformers for DC voltage conversion

Abstract Direct current (DC) converters play an essential role in electronic circuits. Conventional high-efficiency DC voltage converters, especially step-up type, rely on switching operation, where energy is periodically stored within and released from inductors and/or capacitors connected in a variety of circuit topologies. Since these energy storage components, especially inductors, are fundamentally difficult to scale down, miniaturization of switching converters proves challenging. Furthermore, the resulting switching currents produce significant electromagnetic noise. To overcome the limitations of switching converters, photonic transformers, where voltage conversion is achieved through light emission and detection processes, have been demonstrated. However, the demonstrated efficiency is significantly below that of the switching converter. Here we perform a detailed balance analysis and show that with a monolithically integrated design that enables efficient photon transport, the photonic transformer can operate with a near-unity conversion efficiency and high voltage conversion ratio. We validate the theory with a transformer constructed with off-the-shelf discrete components. Our experiment showcases near noiseless operation and a voltage conversion ratio that is significantly higher than obtained in previous photonic transformers. Our findings point to the possibility of a high-performance optical solution to miniaturizing DC power converters and improving the electromagnetic compatibility and quality of electrical power.

42 ENGINEERING↗

Blading Phase–Pure Formamidinium–Alloyed Perovskites for High–Efficiency Solar Cells with Low Photovoltage Deficit and Improved Stability

Currently, blade-coated perovskite solar cells (PSCs) with high power conversion efficiencies (PCEs), i.e. greater than 20%, normally employ methylammonium lead tri-iodide with a sub-optimal bandgap. Alloyed perovskites with formamidinium (FA) cation have narrower bandgap and thus enhance device photocurrent. However, FA-alloyed perovskites show low phase stability and high moisture sensitivity. Here, we report that incorporating 0.83 molar percent organic halide salts (OHs) into the perovskite inks enables phase-pure, highly crystalline FA-alloyed perovskites with extraordinary optoelectronic properties. Here, the OH molecules modulate the crystal growth, enhance the phase stability, passivate ionic defects at the surface and/or grain boundaries, and enhance the moisture stability of the perovskite film. We demonstrate a high efficiency of 22.0% under 1 sun illumination for blade-coated PSCs with an open-circuit voltage of 1.18 V, corresponding to a very small voltage deficit of 0.33 V, and significantly improved operational stability with 96% of the initial efficiency retained under one sun illumination for 500 hours.

14 SOLAR ENERGY↗

Sustainable chemistry with plasmonic photocatalysts

There is a pressing global need to increase the use of renewable energy sources and limit greenhouse gas emissions. Towards this goal, highly efficient and molecularly selective chemical processes that operate under mild conditions are critical. Plasmonic photocatalysis uses optically resonant metallic nanoparticles and their resulting plasmonic, electronic, and phononic light-matter interactions to drive chemical reactions. The promise of simultaneous high-efficiency and product-selective reactions with plasmon photocatalysis provides a compelling opportunity to rethink how chemistry is achieved. Plasmonic nanoparticles serve as nanoscale ‘antennas’ that enable strong light–matter interactions, surpassing the light-harvesting capabilities one would expect purely from their size. Complex composite structures, combining engineered light harvesters with more chemically active components, are a focal point of current research endeavors. In this review, we provide an overview of recent advances in plasmonic catalysis. We start with a discussion of the relevant mechanisms in photochemical transformations and explain hot-carrier generation and distributions from several ubiquitous plasmonic antennae. Then we highlight three important types of catalytic processes for sustainable chemistry: ammonia synthesis, hydrogen production and CO 2 reduction. To help elucidate the reaction mechanism, both state-of-art electromagnetic calculations and quantum mechanistic calculations are discussed. This review provides insights to better understand the mechanism of plasmonic photocatalysis with a variety of metallic and composite nanostructures toward designing and controlling improved platforms for green chemistry in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗

Impact of Thermal Stress on Attachment and Stability of High Temperature Strain Sensors

Static and dynamic strain sensing is required in high-temperature (HT), harsh-environments (HE) for industrial, aerospace, and energy sector applications to ensure equipment and process safety, reduce the cost of operation and maintenance, and increase process efficiency. Challenges that arise in HT HE sensing applications include device mounting, packaging, integrity, and stability to HT HE conditions. In previously reported work, static and dynamic strain surface acoustic wave resonator (SAWR) sensors were fabricated on langasite (LGS) and mounted on Inconel 625 strain beams for wireless testing up to 400°C. In this work, it has been identified that after subjecting the mounted SAWR strain sensor to thermal cycling between 100°C and 425°C, the measured sensitivity to dynamic strain decreased by 73% due to cracking at the adhesive/LGS interface, further deteriorating after additional thermal cycles. Strain modeling of the mounted LGS sensor chip up to 400°C revealed the existence of concentrated strain at the borders of the LGS chip. Microcracks caused by dicing make the chip boarders the most susceptible location for cracks to initiate when the sensor is subjected to thermal stress. In an attempt to mitigate the high strain at the LGS chip borders due to heating, adhesive shaping is proposed in this work. Simulations indicate a strain reduction of 50% at the border is achieved using both circular and triangular adhesive shapes, while also reducing the maximum strain over the entire adhesive/LGS interface by around 30%. Furthermore, the technique is thus promising for improving the integrity, reliability, and stability of static and dynamic strain sensors, particularly while operating under HT HE with several hundreddegree Celsius temperature excursions.

47 OTHER INSTRUMENTATION↗

Computationally efficient models for aqueous organic redox flow batteries

The rising usage of intermittent energy has garnered the need for large scale energy storage systems. Redox flow batteries (RFB) based energy storage system shows promising potential. Numerical simulations and machine learning approaches have been widely used to study RFB performance. The development of autonomous material discovery framework and digital twin of energy storage system usually needs to query cell performance through fast response models. In this study, two computationally efficient models are introduced: a physics-based analytical flow battery model (EZBattery), and a machine learning operator model (Deep Operator Network, denoted by DeepONet). Both models can provide cell performance near instantly, and prediction accuracy was systematically examined on an application of evaluating the performances of a 780 cm 2 aqueous organic redox flow battery (AORFB), using potential anolyte candidates in dihydroxyphenazine (DHP)-based family of organic materials. A validated computationally expansive 3-dimensional multi-physics finite element model by COMSOL was used as the ground truth and provided the training data set for the DeepONet. 1280 samples were generated with 10 properties to mimic the different possible anolyte candidates, and the cell performances were evaluated under 10 different combined operating conditions. The accuracy comparisons for the two computationally efficient models show that both models can provide comparable accuracy in predicting cell charging/discharging voltage curves. DeepONet can provide slightly higher overall accuracy than EZBattery with faster calculation speed, but highly relies on the training dataset. EZBattery does not need a training dataset and can provide interpretable physics-based explanations of the results, while being more flexible to adjust to adapt any different cell designs, flow battery architectures, and electrolyte materials.

Analytical model↗

SiC and GaN Devices With Cryogenic Cooling

This article presents the cryogenically cooled application for wide bandgap (WBG) semiconductor devices. Characteristics of silicon carbide (SiC) and gallium nitride (GaN) at cryogenic temperatures are illustrated. SiC MOSFETs exhibit increased on-state resistance and slower switching speed at cryogenic temperatures. However, cryogenic cooling provides low ambient temperature environment and thus enables the SiC converter to operate at lower junction temperature to achieve higher efficiency compared to room temperature cooling. A cryogenically cooled MW-level SiC inverter prototype is developed and demonstrated the feasibility of operating high-power SiC converter with cryogenic cooling. GaN HEMTs exhibit more than five times on-state resistance reduction and faster switching speed at cryogenic temperatures which makes GaN HEMTs an excellent candidate for cryogenic power electronics applications. The significantly reduced on-state resistance of GaN devices provides the possibility to operate them at a current level much higher than rated current at cryogenic temperatures. A GaN double pulse test (DPT) circuit is constructed and demonstrated that GaN HEMTs can operate at nearly four times of rated current at cryogenic temperatures. Challenges of utilizing WBG device with cryogenic cooling are discussed and summarized.

42 ENGINEERING↗