Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Regional Algal Feedstock Testebed (RAFT) Final Report

The RAFT project completed detailed characterization of 12 twelve potential production strains and extensively tested 3 the three best strains in long term seasonal cultivation trials. A total of x 272 cultivation experiments were completed at the three outdoor testbed locations as part of long term cultivation trials conducted over a three year period. The cultivation experiments tested various harvest strategies, crop protection strategies, and seasonal effects along with strain rotation strategies. A sensor, that continuously monitors cell density, was developed and a patent application was submitted. Models were develop and validated for predicting strain performance, determining biomass productivity, evaluating cultivation system design and operations, and evaluating large scale production scenarios. A detailed data base was established for the long term cultivation trials with discrete data from the x 272 testbed cultivation experiments. This data base will be maintained at the University of Arizona https://raft.arizona.edu/cultivation-data/ for public access and continued academic evaluations.

09 BIOMASS FUELS↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochromic Window Demonstration at the 911 Federal Building, 911 Northeast 11th Avenue, Portland, Oregon

Switchable electrochromic (EC) windows are part of a new class of dynamic, energy-efficient technologies that enable real-time, active load management in response to weather conditions and the unique operating conditions of individual buildings. Owners can now specify a solid-state technology that reacts to various stimuli like the skin of a living entity. The technology can be controlled to address multiple criteria to achieve a more optimal energy-efficient and comfortable indoor environment than one with static or manually operated technologies. Inputs can include data on outdoor solar conditions, utility rates, occupancy status, heating, ventilation, and air conditioning (HVAC), or operating emergency or security mode. The outputs then dictate how the EC window is controlled, whether as a self-contained autonomous unit that achieves specific zonal objectives or as a part of an integrated system designed to address whole building, campus and grid-related goals. Since windows typically have a 30-year life, these dynamic qualities enable the building to be adaptable and more resilient as the environmental, operating and economic context evolves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Warming-Induced Biome Change at the Temperate-Boreal Ecotone: An Experimental Test of Key Regeneration Processes (Final Technical Report)

This project advanced our understanding of plants’ key physiological and ecological processes that are essential to the survival, success, and carbon cycling of plants from the boreal-temperate forest ecotone in the future climate. A primary goal of the project was to test the effect of warming and water limitation on plants from the Boreal-Temperate Ecotone using a realistic outdoor long-term experiment. Plant at this ecotone is predicted to be particularly sensitive to future climate since the ecotone represents a relatively sharp boundary between many temperate species to the south and boreal species to the north. This work was important, as there was and still is a significant uncertainty surrounding the mechanisms of future climate effects on vegetation compositional and carbon cycling change, especially in forests mostly due to lack of experimental examination of response to warming and limited water availability. Consequently, we tested our central objective, that was to assess the potential for projected climate to alter tree species composition and carbon cycling at the southern boreal-temperate forest ecotone by experimentally warming forest plots and documenting effects on establishment and juvenile performance for tree species near their warmer (boreal species) and colder (temperate species) range limits in northern Minnesota. To accomplish our goals, we designed and built a successful highly manipulative experiment that implemented vegetation-soil warming and rainfall removal in both understory and open habitats at two sites in northern Minnesota (MN). The sites lie at different distances to the north of the ecotone between the southern boreal and northern temperate forest biomes. We focused on ten target species, all of which are near their warmer (Pinus banksiana, Picea glauca, Abies balsamea, Populus tremuloides, Betula papyrifera) or colder (Pinus strobus, Quercus macrocarpa, Quercus rubra, Acer rubrum, Acer saccharum) range edge in northern MN; we also studied other species such as a woody invader and native herbs and shrubs. Three temperature treatments (ambient, +1.7°C, +3.4°C) were imposed using infra-red heating lamps augmented with soil heating cables to simultaneously control soil and vegetation temperatures, enabling assessment of non-linear responses. These temperatures bracket the range of anticipated warming in the region during the next 75-100 years. In addition, we implemented summer rain removal treatment mimicking predicted distribution in precipitation patterns by future climate where we actively removed ~40% of rainfall. Measurements included germinant establishment, plant growth, phenology, physiology and survival, soil, plant and air temperature, soil moisture and nutrient status. These measures enabled us to assess how germination, growth and survival at the establishment stage are influenced by direct climate effects and/or indirect effects of warming, soil resources such as water and nutrients availability or other environmental variables that either directly or indirectly influence plant performance.

60 APPLIED LIFE SCIENCES↗

Algal Cultivation Growth Dynamic Modeling and Analysis

The purpose of this PTS was for Sandia National Laboratories (Sandia) to conduct collaborative research with Arizona Board of Regents for and on behalf of Arizona State University (ASU) to further develop algae growth and computational fluid dynamics (CFO) models that can predict and optimize pond design and cultivation methods to improve algal yield in outdoor algal ponds.

Gharagozloo, Patricia↗

Algal Predator and Pathogen Signature Verification

The purpose of this PTS was to conduct work with Arizona State University (ASU), specifically to further develop Spectroradiometric-based technology that has potential to function as early warning of the active presence of predators and pathogens in outdoor algal ponds. Chlorella sorokiniana and the pathogen, Vampirovibrio chlorellavorus were selected for investigation because they had previously been implicated in several pond crashes at ASU’s Arizona Center for Algal Technology and Innovation (AzCATI). Sandia conducted small-scale laboratory experiments comparing control and infected cultures of C. sorokiniana . Spectrally-resolved reflectivity data, as well as optical density, and pulse amplitude modulated fluorescence (PAM) were collected and analyzed to identify the spectral response of active V. chlorellavorus infection. The results of this limited, yet robust, experiment confirmed the initial hypothesis that signature V. chlorellavorus infection of C. sorokiniana could be identified based on the presence of a chlorophyll metabolites generated when the algal chlorophyll is degraded by the pathogen.

Timlin, Jerilyn↗

B341 MoMs Hydraulic System Design & Installation

This Statement of Work Document outlines the program equipment siting requirements for Building 341 to be installed at Lawrence Livermore National Laboratory (LLNL). The Subcontractor, who will be designing and installing B341 programmatic equipment hydraulic system, will be expected to provide engineering and construction support from procurement through installation. This scope of work includes the following: a) Walkdown and survey existing condition of Mechanics of Material (MoMs) programmatic equipment at B231. b) Engineering design, procurement, and installation of hydraulic system for MOMs programmatic equipment. c) Engineering design, procurement, and installation of indoor and outdoor hydraulic pumps. d) Engineering design of program equipment pits. e) Engineering design of new trenches to match existing B341 trenches.

42 ENGINEERING↗

Smart Ventilation for Advanced California Homes – Single Zone Technology Task

This study is intended to demonstrate the potential for energy savings while providing acceptable Indoor Air Quality (IAQ) for ZNE homes. It uses the concept of Smart Ventilation where ventilation systems are designed and controlled to produce the same, or better, IAQ compared to simple, continuously operated ventilation systems. The key energy saving principle for smart ventilation is that ventilation is shifted in time to when the energy required to condition the air is lower. A variety of smart ventilation controls based on outdoor temperature, occupancy and auxiliary fan sensing were developed and assessed across homes built to the 2016 Title 24 Prescriptive standards in California climate regions. Simulations used a co-simulation strategy that combines EnergyPlus with CONTAM. The IAQ calculations were based on the equivalent ventilation principle outlined in the ASHRAE 62.2-2016 ventilation standard, Appendix C. Two prototype homes were simulated (1-story 2,100 ft2 and 2-story 2,700 ft2). Their envelope airtightness was varied between 1, 3 and 5 ACH50. Climate zones were chosen to reflect the variety of heating and cooling demand throughout California. A weighted average analysis was used to generalize the energy predictions across the projected new housing stock in the state. Temperature-based controls were found to be effective, with the most successful smart controls reducing weighted average site ventilation energy use by about 40%, while TDV weighted average ventilation energy reductions were higher, up to roughly 60%. Results were also normalized to ensure identical IAQ in all cases, and the weighted average site and TDV ventilation savings increased, up to 55% and 72% ventilation savings, respectively, for the top-performing temperature-based controls. Peak demand during the 2-6pm period on the hottest days of the year was reduced by up to 400 watts. More than 90% of site energy savings were for heating end-uses, while TDV energy savings were split fairly evenly between heating and cooling. On average, the smart controls reduced occupant pollutant exposure by 0-10%, and they increased ventilation rates by roughly 20%. Occupancy-based controls that accounted for contaminants released by building materials and furnishings during unoccupied times were generally ineffective, with very low energy savings. Performance was improved somewhat through use of a 1-hour pre-occupancy flush out period, though savings were still marginal compared to temperature-based controls. All temperature and occupancy controls were also tested with auxiliary fan sensing capability (i.e., accounting for the use of other exhaust devices in the home, like bathroom or kitchen fans). Auxiliary fan sensing increased energy savings in all cases, from roughly 5 to 15%.

42 ENGINEERING↗

Pool Fire and Fireball Experiments in Support of the US DOE/DOT/TC Crude Oil Characterization Research Study

This report describes an experimental study of physical, chemical, and combustion characteristics of selected North American crude oils, and how these associate with thermal hazard distances resulting from pool fires and fireballs. The emergence of large volumes of tight oils within the North American Transportation system over the last decade coupled with several high-profile train accidents involving crude oils, has raised questions about the role of oil properties in general, and tight oils in particular, in affecting the severity of hazard outcomes in related crude oil fires. The objective of the pool fire experiments is to measure parameters necessary for hazard evaluation, namely, burn rate, surface emissive power, flame height, and heat flux to an engulfed object. To carry out this objective, a series of 2-m diameter indoor and 5-m diameter outdoor experiments were performed. The objective of the fireball experiments is to measure parameters required for hazard evaluation which include fireball maximum diameter, height at maximum diameter, duration, and surface emissive power using 400-gallons of crude oil per test. The crude oil samples used for the experiments were obtained from several U.S. locations, including including “tight” oils from the Bakken region of North Dakota and Permian region of Texas, and a conventionally produced oil from the U.S. Strategic Petroleum Reserve stockpile. These samples spanned a measurable range of vapor pressure (VPCR x (T)) and light ends content representative of U.S. domestic conventional and tight crudes. The results indicate that all the oils tested here have comparable thermal hazard distances and the measured properties are consistent with other alkane-based hydrocarbon liquids. The similarity of pool fire and fireball burn characteristics pertinent to thermal hazard outcomes of the three oils studied indicate that vapor pressure is not a statistically significant factor in affecting these outcomes. Thus, the results from this work do not support creating a distinction for crude oils based on vapor pressure with regards to these combustion events.

02 PETROLEUM↗

Environmental Soil Screening Levels for Cs-137 at University of Washington Medical Center

Current radiological surveys (exposure rate measurements and smear surveys) conducted outside the University of Washington (UW) Harborview Research and Training building found no evidence of Cs-137 contamination in public walk ways, or open areas, and preliminary soil concentrations from samples upwind and downwind of the building were within global fallout levels found in the region. Additional soil and outdoor surface sampling is being considered to more fully assess the possibility of an environmental release during the incident and the radiological impact, if any. This analysis is designed to assist in the evaluation of soil sample results and provide radiation dose-based Soil Screening Levels (SSLs) to help develop sampling and analysis plans and for evaluating these measurements in the context of radiation dose limits. Soil samples could be used to answer two general questions. The first asks if any detected Cs-137 in the soil is above global fallout levels measured in the area. Calculations based on fallout levels from Beck and Bennett (2002) and NCRP 154 suggest that current global fallout levels in Seattle area soil would range up to about 3 pCi/g in undisturbed soils, but there would be large variations based on a variety of transport factors related to the urban environment surrounding the area. Based on the sample result, any measurement significantly above background could prompt additional analysis including looking at the ratio of the Cs-137 to Pu-239/240 to help identify the source of the Cs-137, that is, from global fallout or from the incident. The second question is if there is detectable Cs-137 in the soil, what is the radiological impact of the Cs-137? For this, a dose pathway analysis using the RESRAD model was done to protectively estimate soil-based dose conversion factors and SSLs for Cs-137 in soil.

54 ENVIRONMENTAL SCIENCES↗

Development and Evaluation of a Rotating Heat Exchanger for HVAC Applications

This report describes the first design of an HVAC heat exchanger using the Sandia Cooler, i.e. air - bearing supported rotating heat exchanger. The project included developing baseline performance requirements based on a residential HVAC system, analysis and design development of a Sandia Cooler assembly including a UTRC - designed diffuser, and performance measurement and validation of this heat exchange system under realistic indoor and outdoor conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Visitors Guide and Map

Fermilab is America’s national laboratory dedicated to particle physics and accelerator research. If you’re looking for opportunities to enjoy nature, learn about cutting edge research and have a little fun, Fermilab has you covered. The public outdoor areas of our 6,800-acre site are open from 8 a.m. to 6 p.m. from November to March, and from 8 a.m. to 8 p.m. the rest of the year.

99 GENERAL AND MISCELLANEOUS↗

Regional Shelter Analysis: Inhalation Exposure Application (Particles)

During normal operations, buildings can protect their occupants from outdoor hazards, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. However, only recently has an operationally efficient, regional-scale methodology - called Regional Shelter Analysis (RSA) - become available to account for both building protection and the distribution of people within and among buildings.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Vulnerabilities Associated with Connected Lighting: Exploring Authorization Protocols

Cities are upgrading their infrastructure and converting traditional indoor and outdoor luminaires to Connected Lighting Systems equipped with sensors in an aggressive effort to reduce energy consumption, increase sustainability, and improve the quality of life. When you take something seemingly benign like a lighting system and connect it to the internet, if improperly secured a potential attack vector for hackers is created. Hackers could then access sensitive information, pivot into other networks, shut down services, or enslave devices to do their bidding. In attempt to close this attack vector and secure these systems, this paper extends previous work that investigated, compared and contrasted authentication vulnerabilities in Connected Lighting Systems that identified the need for additional testing and improved test method documentation. One additional authentication test and four new authorization tests were developed utilizing the Open Web Application Security Project (OWASP) as a test development and documentation guide. The new tests were integrated with the previous work to develop an updated test method with a focus on describing test procedures to make them easy to understand and repeat. In addition, a first Connected Lighting System use case was established to begin developing threat profiles that will aid in the identification of vulnerabilities whose focus areas extend beyond authentication and authorization. This use case describes the generation and flow of CLS data which assists in specifying methods to harden CLSs from outside interference and exploitation that can be implemented immediately on existing CLSs and as new products come to market.

97 MATHEMATICS AND COMPUTING↗

Pressure Safety Data Package for Remote Balloon Launcher (RBL)

The Barrow Hydrogen Fill System is intended for use by the authorized Sandia National Laboratories personnel and its contractors who are involved in research relating to the deployment of weather balloons for the Department of Energy's Atmospheric Radiation Measurement Program (ARM) https://www.arm.gov/ and The National Weather Service (NWS) https://www.weather.gov/. Hydrogen is supplied from a hydrogen generation shelter and outdoor storage tank. The balloons are filled and released by a remote balloon launcher (RBL) commercially available from Vaisala. The RBL was designed to be used with helium or hydrogen and has be recently inspected by Vaisala for hydrogen operation. This system is composed of a pressure regulator, ball valves, pressure relief valves, tubing, hose. All pressurized components are "off the shelf items and have a minimum pressure rating of 300 psi and are assembled using "Best Practices" and trained pressure component installers. Non pressurized components are comprised of industry recommended components and are assembled using "Best Practices" techniques.

42 ENGINEERING↗

Angle of Incidence Characterization of Six Laminated Solar Cells for 2020 DTU Fotonik Inter-Laboratory Comparison Study

Photovoltaic energy prediction models include functions or modifiers to account for sun angle reflection losses. These functions may be known interchangeably as Angle of Incidence (AOI) or Incident Angle Modifier (IAM). While standards exist, there is no universally accepted single best practice for developing these functions. They can be generated through characterization of representative modules or single cells, in natural sunlight or indoors using simulated light sources. Repeatability of measurements and the viability of cross-laboratory comparisons are critical to confidence in validation of both methods. To investigate the differences between methods and labs, The Technical University of Denmark (DTU) initiated an international round-robin test comparison between several key test labs with AOI measurement capability. A total of six minimodules were provided in three different cell/interconnect/backsheet combinations. Sandia characterized these minimodules using methods developed over two decades specifically for the outdoor characterization of full-size photovoltaic modules. This report documents the characterization results, summarizes key observations and tabulates the processed data for comparison to results provided by other characterization labs.

14 SOLAR ENERGY↗

Human Health Risk Assessment Methods for PV (Part 2: Breakage Risks)

Photovoltaic (PV) modules are designed and tested for long-term durability in harsh outdoor environments, but a small percentage may break during installation or operation. Some industry stakeholders have expressed concerns regarding potential human exposure to hazardous materials should a PV module break in the field. To evaluate these concerns, screening-level risk assessment methods are presented that can estimate emissions that may occur when broken PV modules are exposed to rainwater, estimate the associated chemical concentrations in soil, groundwater and air, and finally compare these exposure-point concentrations to health-protective screening levels based on 1 x 10-6 cancer risk and hazard quotient of 1. The screening-level methods can be used to decide whether further evaluation of potential health risks is warranted. A few example scenarios demonstrate application of the methods. Specifically, this report presents an analysis of potential human health impacts associated with rainwater leaching from broken modules for two PV technologies, focusing on release of the highest-prioritized chemical element for each: lead (Pb) content in crystalline-silicon (c-Si) PV modules and cadmium (Cd) content in thin film cadmium telluride (CdTe) PV modules. The prioritization of these chemical elements for analysis is based on stakeholder interest. Because the methodology is chemical-specific, the risk assessment results for these chemicals cannot be directly generalized to other chemicals, although the risk assessment methodology can be applied to other chemicals.

14 SOLAR ENERGY↗

Nuclear Safeguards Applications Employing Unmanned Airborne Vehicles

This paper describes some potential applications for UAVs (Unmanned Aerial Vehicles) in international nuclear safeguards. UAV missions can include indoor and outdoor operations including: 1) surveillance, which includes all types of sensors and imagers, 2) command and control augmentation (radio relays and real-time imagery used primarily to coordinate ground operations), and 3) physical sample collection and transport.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗