Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear level density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Modeling of Unsaturated Salt-cake Dissolution for S-109 Simulant

The Environmental Simulation Program (V7.0, OLI Systems, Inc.) with V7DBLSLT, the latest version of the double salt database developed by the Institute of Clean Energy Technology (ICET), was used to predict effluent stream compositions and densities, residual salt-cake composition, and salt-cake heights for an unsaturated salt-cake dissolution test with a simulant representative of waste contained in Hanford tank 241-S-109. Predictions for major cation and anion concentrations were in excellent agreement with the experimental data obtained at the Applied Research Center (ARC) at Florida International University (FIU). The utility of ESP as a means to predict effluent stream compositions and effluent stream properties, such as density and column salt-cake height, is demonstrated through the agreement between experimental and predicted values. These, and previous calculations, validate the use of thermodynamic models (with proper chemistry representations) for HLW pretreatment and retrievals. A powerful and useful tool is the result. Cost reductions are possible as the amount of sampling and subsequent laboratory analysis can be reduced. Additionally, overall processing risk is reduced through the ability to rapidly evaluate different processing and retrieval scenarios. The application of appropriate models can thus lead to more efficient operations and campaign cost savings while also evaluating parameters pertinent to safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 22 Supernate Sample Characterization for Select Radionuclides

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR), through a Technical Assistance Request (G-TAR-H-00007) to provide additional sample characterization on unfiltered Tank 22 supernate identified as sample HTF-22-18-117, which was delivered to SRNL Shielded Cells on December 14, 2018. A summary of the average analytical results for this unfiltered Tank 22 supernate liquid follows. The density of the unfiltered Tank 22 supernate is 1.008 g/mL, 0.2%RSD. The Tank 22 supernate sample was analyzed for a total of 45 radionuclide species, with 15 of these radionuclides showing activity levels above minimum detectable activity of at least one replicate. Cesium-137 showed the highest activity at 2.90E+07 dpm/mL, 2.35 %RSD (1.30E-02 Ci/ L) with U-235 showing the lowest measurable activity at an average of 1.66E-01 dpm/mL, 6.26 %RSD (7.49E-11 Ci/L). The primary beta emitting radionuclides in the unfiltered Tank 22 supernate sample include Sr-90, Y-90 and Cs-137 at average activity concentrations of 1.10E-05, 1.10E-05 and 1.30E-02 Ci/L, respectively. The primary gamma emitting radionuclide is Ba-137 m at an average activity concentration of 1.23E-02 Ci/L (note that the activity concentration for Ba-137 m was calculated as 94.7% the Cs-137 activity concentration).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multipurpose epithermal neutron beam on new research station at MARIA research reactor in Swierk-Poland

MARIA reactor is an open-pool research reactor what gives the chance to install uranium fission converter on the periphery of the core. It could be installed far enough not to induce reactivity of the core but close enough to produce high flux of fast neutrons. Special design of the converter is now under construction. It is planned to set the research stand based on such uranium converter in the near future: in 2015 MARIA reactor infrastructure should be ready (preparation started in 2013), in 2016 the neutron beam starts and in 2017 opening the stand for material and biological research or for medical training concerning BNCT. Unused for many years, horizontal channel number H2 at MARIA research rector in Poland, is going to be prepared as a part of unique stand. The characteristics of the neutron beam will be significant advantage of the facility. High flux of neutrons at the level of 2x10{sup 9} cm{sup -2}s{sup -1} will be obtainable by uranium neutron converter located 90 cm far from the reactor core fuel elements (still inside reactor core basket between so called core reflectors). Due to reaction of core neutrons with converter U{sub 3}Si{sub 2} material it will produce high flux of fast neutrons. After conversion neutrons will be collimated and moderated in the channel by special set of filters and moderators. At the end of H2 channel i.e. at the entrance to the research room neutron energy will be in the epithermal energy range with neutron intensity at least at the level required for BNCT (2x10{sup 9} cm{sup -2}s{sup -1}). For other purposes density of the neutron flux could be smaller. The possibility to change type and amount of installed filters/moderators which enables getting different properties of the beam (neutron energy spectrum, neutron-gamma ratio and beam profile and shape) is taken into account. H2 channel is located in separate room which is adjacent to two other empty rooms under the preparation for research laboratories (200 m2). It is planned to create fully equipped complex facility possible to perform various experiments on the intensive neutron beam. Epithermal neutron beam enables development across the full spectrum of materials research for example shielding concrete tests or electronic devices construction improvement. Due to recent reports on the construction of the accelerator for the Boron Neutron Capture Therapy (BNCT) it has the opportunity to become useful and successful method in the fight against brain and other types of cancers not treated with well known medical methods. In Europe there is no such epithermal neutron source which could be used throughout the year for training and research for scientist working on BNCT what makes the stand unique in Europe. Also our research group which specializes in mixed radiation dosimetry around nuclear and medical facilities would be able to carry out research on new detectors and methods of measurements for radiological protection and in-beam (therapeutic) dosimetry. Another group of scientists from National Centre for Nuclear Research, where MARIA research reactor is located, is involved in research of gamma detector systems. There is an idea to develop Prompt-gamma Single Photon Emission Computed Tomography (Pg- SPECT). This method could be used as imaging system for compounds emitting gamma rays after nuclear reaction with thermal neutrons e.g. for boron concentration in BNCT. Inside the room, where H2 channel is located, there is another horizontal channel - H1 which is also unused. Simultaneously with the construction of the H2 stand it will be possible to create special pneumatic horizontal mail inside the H1 channel for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. It might expand the scope of research at the planned neutron station. Secondly it is planned to equip both stands with moveable positioning system, video system and facilities to perform animal experiments (anaesthesia, vital signs control, imaging devices, positioning). These all above make constructed station unique in the world (uranium fission converter-based beam) and the only one of such intense neutron beam in the Europe. Moreover implementation of the station would allow the development of research on a number of issues for researchers from all over the Europe. One of very important advantages of the station is undisturbed exploitation of the reactor and other vertical and horizontal channels. MARIA reactor operates 6000 hours per year and that amount of time will be achievable for research on the neutron station. It have to be underlined that new neutron station will work parallel to all another ventures. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aging-Dependent Changes in the Radiation Response of the Adult Rat Brain

Purpose: To assess the impact of aging on the radiation response in the adult rat brain. Methods and Materials: Male rats 8, 18, or 28 months of age received a single 10-Gy dose of whole-brain irradiation (WBI). The hippocampal dentate gyrus was analyzed 1 and 10 weeks later for sensitive neurobiologic markers associated with radiation-induced damage: changes in density of proliferating cells, immature neurons, total microglia, and activated microglia. Results: A significant decrease in basal levels of proliferating cells and immature neurons and increased microglial activation occurred with normal aging. The WBI induced a transient increase in proliferation that was greater in older animals. This proliferation response did not increase the number of immature neurons, which decreased after WBI in young rats, but not in old rats. Total microglial numbers decreased after WBI at all ages, but microglial activation increased markedly, particularly in older animals. Conclusions: Age is an important factor to consider when investigating the radiation response of the brain. In contrast to young adults, older rats show no sustained decrease in number of immature neurons after WBI, but have a greater inflammatory response. The latter may have an enhanced role in the development of radiation-induced cognitive dysfunction in older individuals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved accuracy and robustness of electron density profiles from JET’s X-mode frequency-modulated continuous-wave reflectometers

JET’s frequency-modulated continuous wave (FMCW) reflectometers have been operating well with the current design since 2005, and density profiles have been automatically calculated intershot since then. However, the calculated profiles had long suffered from several shortcomings: poor agreement with other diagnostics, sometimes inappropriately moving radially by several centimeters, elevated levels of radial jitter, and persistent wriggles (strong unphysical oscillations). Here, in this research, several techniques are applied to the reflectometry data analysis, and the shortcomings are significantly improved. Starting with improving the equilibrium reconstruction that estimates the background magnetic field, adding a ripple correction in the reconstructed magnetic field profile, and adding new inner-wall reflection positions estimated through ray-tracing, these changes not only improve the agreement of reconstructed profiles to other diagnostics but also solve density profile wriggles that were present during band transitions. Other smaller but also persistent wriggles were also suppressed by applying a localized correction to the measured beat frequency where persistent oscillations are present. Finally, the burst analysis method, as introduced by Varela et al., has been implemented to extract the beat frequency from stacked spectrograms. Due to the strong suppression of spurious reflections, the radial jitter that sometimes would span several centimeters has been strongly reduced. The stacking of spectrograms has also been shown to be very useful for stacking recurring events, like small gas puff modulations, and extracting transport coefficients that would otherwise be below the noise level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect study of the stellar Ar 34 ( α , p ) K 37 reaction rate through Ca 40 ( p , t ) Ca 38 reaction measurements

The 34 Ar(α,p) 37 K reaction is believed to be one of the last in a sequence of (α,p) and (p,γ) reactions within the T z = -1 , sd-shell nuclei, known as the αp-process. This process is expected to influence the shape and rise times of luminosity curves coming from type I x-ray bursts (XRBs). With very little experimental information known on many of the reactions within the αp-process, stellar rates are calculated using a statistical model, such as Hauser-Feshbach. Questions on the applicability of a Hauser-Feshbach model for the 34 Ar (α,p) 37 K reaction arise due to level density considerations in the compound nucleus, 38 Ca . We have performed high energy-resolution forward-angle 40 Ca (p,t) 38 Ca measurements with the K = 600 spectrograph at iThemba LABS in order to identify levels above the α-threshold in 38 Ca . States identified in this work were then used to determine the 34 Ar (α,p) 37 K reaction rate based on a narrow-resonance formalism. Comparisons are made to two standard Hauser-Feshbach model predicted rates at XRB temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

NEUTRALIZATIONS OF HIGH ALUMINUM LOW URANIUM USED NUCLEAR FUEL SOLUTIONS CONTAINING GADOLINIUM AS A NEUTRON POISON

H-Canyon will begin dissolving High Aluminum - Low Uranium (High Al/Low U) Used Nuclear Fuel (UNF) following approval by DOE which is anticipated in CY2011. High Al/Low U is an aluminum/enriched uranium UNF with small quantities of uranium relative to aluminum. The maximum enrichment level expected is 93% {sup 235}U. The High Al/Low U UNF will be dissolved in H-Canyon in a nitric acid/mercury/gadolinium solution. The resulting solution will be neutralized and transferred to Tank 39H in the Tank Farm. To confirm that the solution generated could be poisoned with Gd, neutralized, and discarded to the Savannah River Site (SRS) high level waste (HLW) system without undue nuclear safety concerns the caustic precipitation of simulant solutions was examined. Experiments were performed with three simulant solutions representative of the H-Canyon estimated concentrations in the final solutions after dissolution. The maximum U, Gd, and Al concentration were selected for testing from the range of solution compositions provided. Simulants were prepared in three different nitric acid concentrations, ranging from 0.5 to 1.5 M. The simulant solutions were neutralized to four different endpoints: (1) just before a solid phase was formed (pH 3.5-4), (2) the point where a solid phase was obtained, (3) 0.8 M free hydroxide, and (4) 1.2 M free hydroxide, using 50 wt % sodium hydroxide (NaOH). The settling behavior of the neutralized solutions was found to be slower compared to previous studies, with settling continuing over a one week period. Due to the high concentration of Al in these solutions, precipitation of solids was observed immediately upon addition of NaOH. Precipitation continued as additional NaOH was added, reaching a point where the mixture becomes almost completely solid due to the large amount of precipitate. As additional NaOH was added, some of the precipitate began to redissolve, and the solutions neutralized to the final two endpoints mixed easily and had expected densities of typical neutralized waste. Based on particle size and scanning electron microscopy analyses, the neutralized solids were found to be homogeneous and less than 20 microns in size. The majority of solids were less than 4 microns in size. Compared to previous studies, a larger percentage of the Gd was found to precipitate in the partially neutralized solutions (at pH 3.5-4). In addition the Gd:U mass ratio was found to be at least 1.0 in all of the solids obtained after partial or full neutralization. The hydrogen to U (H:U) molar ratios for two accident scenarios were also determined. The first was for transient neutralization and agitator failure. Experimentally this scenario was determined by measuring the H:U ratio of the settled solids. The minimum H:U molar ratio for solids from fully neutralized solutions was 388:1. The second accident scenario is for the solids drying out in an unagitiated pump box. Experimentally, this scenario was determined by measuring the H:U molar ratio in centrifuged solids. The minimum H:U atom ratios for centrifuged precipitated solids was 250:1. It was determined previously that a 30:1 H:Pu atom ratio was sufficient for a 1:1 Gd:Pu mass ratio. Assuming a 1:1 equivalence with {sup 239}Pu, the results of these experiments show Gd is a viable poison for neutralizing U/Gd solutions with the tested compositions.

08 HYDROGEN↗

Low-Density Lipoprotein Cholesterol After an Acute Coronary Syndrome: How Low to Go?

Purpose of Review: Recent advances in low-density lipoprotein cholesterol (LDL-C) lowering therapy have now enabled reducing LDL-C safely to very low levels. This review summarizes evidence from recent randomized clinical trials of intensive LDL-C lowering in patients with acute coronary syndrome (ACS) and provides a practical approach for LDL-C lowering to reduce the risk of recurrent ischemic events in this population. Recent Findings: The risk of atherothrombotic events falls linearly with LDL-C level extending to very low achieved LDL-C levels (< 10 mg/dL) without apparent safety concerns. The addition of ezetimibe or proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors (i.e., evolocumab or alirocumab) to statin therapy lowers LDL-C to very low levels (≤ 30–50 mg/dL) with safety under the conditions studied and reduces the risk of recurrent cardiovascular events in patients with atherosclerotic cardiovascular disease. Summary: Current data support LDL-C lowering to levels below 70 mg/dL in patients post-ACS. Combination of high-intensity statins, ezetimibe, and if needed PCSK9 inhibitors merits consideration in such patients with ACS to optimize outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Axion dark matter experiment: Run 1B analysis details

Searching for axion dark matter, the ADMX Collaboration acquired data from January to October 2018, over the mass range 2.81–3.31 μeV, corresponding to the frequency range 680–790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 90% confidence level and 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for run 1B, motivating analysis choices informed by details specific to this run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iterative image-domain decomposition for dual-energy CT

Purpose: Dual energy CT (DECT) imaging plays an important role in advanced imaging applications due to its capability of material decomposition. Direct decomposition via matrix inversion suffers from significant degradation of image signal-to-noise ratios, which reduces clinical values of DECT. Existing denoising algorithms achieve suboptimal performance since they suppress image noise either before or after the decomposition and do not fully explore the noise statistical properties of the decomposition process. In this work, the authors propose an iterative image-domain decomposition method for noise suppression in DECT, using the full variance-covariance matrix of the decomposed images. Methods: The proposed algorithm is formulated in the form of least-square estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance-covariance matrix of the decomposed images as the penalty weight in the least-square term. The regularization term enforces the image smoothness by calculating the square sum of neighboring pixel value differences. To retain the boundary sharpness of the decomposed images, the authors detect the edges in the CT images before decomposition. These edge pixels have small weights in the calculation of the regularization term. Distinct from the existing denoising algorithms applied on the images before or after decomposition, the method has an iterative process for noise suppression, with decomposition performed in each iteration. The authors implement the proposed algorithm using a standard conjugate gradient algorithm. The method performance is evaluated using an evaluation phantom (Catphan©600) and an anthropomorphic head phantom. The results are compared with those generated using direct matrix inversion with no noise suppression, a denoising method applied on the decomposed images, and an existing algorithm with similar formulation as the proposed method but with an edge-preserving regularization term. Results: On the Catphan phantom, the method maintains the same spatial resolution on the decomposed images as that of the CT images before decomposition (8 pairs/cm) while significantly reducing their noise standard deviation. Compared to that obtained by the direct matrix inversion, the noise standard deviation in the images decomposed by the proposed algorithm is reduced by over 98%. Without considering the noise correlation properties in the formulation, the denoising scheme degrades the spatial resolution to 6 pairs/cm for the same level of noise suppression. Compared to the edge-preserving algorithm, the method achieves better low-contrast detectability. A quantitative study is performed on the contrast-rod slice of Catphan phantom. The proposed method achieves lower electron density measurement error as compared to that by the direct matrix inversion, and significantly reduces the error variation by over 97%. On the head phantom, the method reduces the noise standard deviation of decomposed images by over 97% without blurring the sinus structures. Conclusions: The authors propose an iterative image-domain decomposition method for DECT. The method combines noise suppression and material decomposition into an iterative process and achieves both goals simultaneously. By exploring the full variance-covariance properties of the decomposed images and utilizing the edge predetection, the proposed algorithm shows superior performance on noise suppression with high image spatial resolution and low-contrast detectability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flexible Conversion Ratio Fast Reactor Systems Evaluation

Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shear-induced metastable states of end-grafted polystyrene

The in situ molecular scale response of end-grafted polystyrene to shear against a deuterated polystyrene melt was investigated with neutron reflectometry. The derived grafted polystyrene density profiles showed that the grafted polystyrene was retained on the quartz wafer during the measurements. The profiles suggested that the end-grafted polystyrene response to shear results in a series of metastable states, rather than equilibrium states assumed in the current theory. Except for some possible extension and/or contraction of the grafted polystyrene with shear, there was no obvious correlation between the grafted polymer structure and the shear thinning behavior observed in these samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of low-level radioactive waste leachate on antioxidant depletion in HDPE geo-membranes - 15135

Low-level radioactive waste (LLW) and mixed waste (MW) disposal facilities in the US are required to have a service life in excess of 1000 yr. Understanding the rate of degradation of high-density polyethylene (HDPE) geo-membranes (GMs) used in barriers of LLW and MW facilities is necessary to assess their service life. HDPE GMs undergo degradation in three stages: antioxidant depletion (Stage I), induction time (stage II), and polymer degradation (Stage III). For LLW and MW facilities, these degradation mechanisms must be assessed with the GM in contact with leachates representative of LLW or MW. This paper focuses on antioxidant depletion in LLW leachate. HDPE GM coupons (2-mm thick) were immersed in radioactive synthetic leachate (RSL) with chemistry representative of leachate in LLW disposal facilities operated by the US Department of Energy's environmental restoration programs. Depletion was assessed at four temperatures (25, 50, 70, and 90 deg.C). Comparative tests were conducted with non-radioactive synthetic leachate (NSL), which has the same chemistry as RSL except radionuclides are excluded. Control tests were conducted with deionized (DI) water. Specimens were removed periodically and tested to determine their mechanical and chemical properties. Antioxidant depletion was measured by both standard and high-pressure oxidative induction time (OIT) tests. The rate of antioxidant depletion in RSL is statistically no different than depletion in NSL. Extrapolating the laboratory data at elevated temperatures to a typical LLW liner at 15 deg.C via Arrhenius modeling showed that the time for antioxidant depletion for a GM in a composite liner is approximately 650 yr when exposed to LLW leachate. Actual service life of the GM will be longer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of stress on Laves phase precipitation in creep ruptured Grade 92 ferritic martensitic steel characterized by a novel accessible method

At high temperature conditions relevant to fossil and nuclear energy plants, Laves phase (Fe 2 X, X=Mo, W) precipitation is observed in common ferritic martensitic (FM) structural steels, with various reported effects on creep behavior. Despite being valuable metrics to correlate with mechanical properties and other precipitate phases, the volume fraction and number density of Laves phase precipitates has been difficult to quantify accurately using common techniques such as transmission electron microscopy (TEM) due to the relatively large size (∼0.25 μm) and low number density (∼10 11 cm −3 ) of Laves precipitates. Here, to address this characterization challenge, we developed and demonstrated a high-throughput and widely accessible method to quantify the volume fraction and number density of the Laves phase based on scanning electron microscope (SEM) images with a backscattered electron signal and the information depth (ID) of backscattered electrons. We applied this new technique in creep ruptured Grade 92 FM steel to study the effect of Laves phase on creep properties and determine the influence of stress on Laves phase precipitation. The quantitative accuracy of the SEM-based volume fraction and number density values was verified using synchrotron high energy X-ray diffraction and serial sectioning tomography. Stress did not significantly affect the Laves phase size or volume fraction during creep testing at 550 – 650°C and stress levels of 90 – 260 MPa (vs. unstressed conditions). Conversely, a moderate but statistically significant stress-enhanced increase in Laves phase number density, corresponding to an increase in nucleation rate, occurred during creep exposure above 110 MPa.

Creep↗

Integrating Epidermal Growth Factor Receptor Assay With Clinical Parameters Improves Risk Classification for Relapse and Survival in Head-and-Neck Squamous Cell Carcinoma

Purpose: Epidermal growth factor receptor (EGFR) overexpression has been consistently found to be an independent predictor of local-regional relapse (LRR) after radiotherapy. We assessed the extent by which it can refine risk classification for overall survival (OS) and LRR in patients with head-and-neck squamous cell carcinoma (HNSCC). Methods and Materials: EGFR expression in locally advanced HNSCC was measured by immunohistochemistry in a series of patients randomized to receive accelerated or conventional radiation regimens in a Phase III trial. Subsequently, data of the two series were pooled (N = 533) for conducting a recursive partitioning analysis that incorporated clinical parameters (e.g., performance status, primary site, T and N categories) and four molecular markers (EGFR, p53, Ki-67, and microvessel density). Results: This study confirmed that patients with higher than median levels of tumor EGFR expression had a lower OS (relative risk [RR]: 1.90, p = 0.0010) and a higher LRR (RR: 1.91, p = 0.0163). Of the four markers analyzed, only EGFR was found to contribute to refining classification of patients into three risk classes with distinct OS and LRR outcomes. The addition of EGFR to three clinical parameters could identify patients having up to a fivefold difference in the risk of LRR. Conclusions: Adding pretreatment EGFR expression data to known robust clinical prognostic variables improved the estimation of the probability for OS and LRR after radiotherapy. Its use for stratifying or selecting patients with defined tumor feature and pattern of relapse for enrollment into clinical trials testing specific therapeutic strategy warrants further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report on Utilization of TRU TRISO Fuel as Applied to HTR Systems Part II: Prismatic Reactor Cross Section Generation

The deep-burn prismatic high temperature reactor is made up of an annular core loaded with transuranic isotopes and surrounded in the center and in the periphery by reflector blocks in graphite. This disposition creates challenges for the neutronics compared to usual light water reactor calculation schemes. The longer mean free path of neutrons in graphite affects the neutron spectrum deep inside the blocks located next to the reflector. The neutron thermalisation in the graphite leads to two characteristic fission peaks at the inner and outer interfaces as a result of the increased thermal flux seen in those assemblies. Spectral changes are seen at least on half of the fuel blocks adjacent to the reflector. This spectral effect of the reflector may prevent us from successfully using the two step scheme -lattice then core calculation- typically used for light water reactors. We have been studying the core without control mechanisms to provide input for the development of a complete calculation scheme. To correct the spectrum at the lattice level, we have tried to generate cross-sections from supercell calculations at the lattice level, thus taking into account part of the graphite surrounding the blocks of interest for generating the homogenised cross-sections for the full-core calculation. This one has been done with 2 to 295 groups to assess if increasing the number of groups leads to more accurate results. A comparison with a classical single block model has been done. Both paths were compared to a reference calculation done with MCNP. It is concluded that the agreement with MCNP is better with supercells, but that the single block model remains quite close if enough groups are kept for the core calculation. 26 groups seems to be a good compromise between time and accu- racy. However, some trials with depletion have shown huge variations of the isotopic composition across a block next to the reflector. It may imply that at least an in- core depletion for the number density calculation may be necessary in the complete calculation scheme.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coupling the core analysis program DeCART to the fuel performance application BISON

The 3D neutron transport and core analysis program DeCART was coupled to the fuels performance application BISON to provide a higher fidelity tool for fuel performance simulation. This project is motivated by the desire to couple a high fidelity core analysis program (based on the method of characteristics) to a high fidelity fuel performance program, both of which can simulate 3D problems. DeCART provides sub-pin level resolution of the multigroup neutron flux, with resonance treatment, during burnup or a fast transient. BISON implicitly solves coupled thermomechanical equations for the fuel on a sub-millimeter level finite element mesh. A method was developed for mapping the fission rate density and fast neutron flux from DeCART to BISON. Multiple depletion cases were run with one-way data transfer from DeCART to BISON. The one-way data transfer of fission rate density is shown to agree with the fission rate density obtained from an internal Lassman-style model in BISON. One-way data transfer was also demonstrated in a 3D case in which azimuthal asymmetry was induced in the fission rate density profile of a fuel rod modeled in DeCART. Two-way data transfer was established by mapping the temperature distribution from BISON to DeCART. A Picard iterative algorithm was developed for the loose coupling with two-way data transfer. (authors)

97 MATHEMATICS AND COMPUTING↗

Correlation of Hypoxia-Inducible Factor 1{alpha} with Angiogenesis in Liver Tumors After Transcatheter Arterial Embolization in an Animal Model

This study sought to determine the expression of hypoxia-inducible factor 1{alpha} (HIF-1{alpha}) and its relation to angiogenesis in liver tumors after transcatheter arterial embolization (TAE) in an animal model. A total of 20 New Zealand White rabbits were implanted with VX2 tumor in liver. TAE-treated group animals (n = 10) received TAE with polyvinyl alcohol particles. Control group animals (n = 10) received sham embolization with distilled water. Six hours or 3 days after TAE, animals were humanely killed, and tumor samples were collected. Immunohistochemical staining was performed to evaluate HIF-1{alpha} and vascular endothelial growth factor (VEGF) protein expression and microvessel density (MVD). Real-time polymerase chain reaction was performed to examine VEGF mRNA levels. The levels of HIF-1{alpha} protein were significantly higher in TAE-treated tumors than those in the control tumors (P = 0.001). HIF-1{alpha} protein was expressed in viable tumor cells that were located predominantly at the periphery of necrotic tumor regions. The levels of VEGF protein and mRNA, and mean MVD were significantly increased in TAE-treated tumors compared with the control tumors (P = 0.001, 0.000, and 0.001, respectively). HIF-1{alpha} protein level was significantly correlated with VEGF mRNA (r = 0.612, P = 0.004) and protein (r = 0.554, P = 0.011), and MVD (r = 0.683, P = 0.001). We conclude that HIF-1{alpha} is overexpressed in VX2 tumors treated with TAE as a result of intratumoral hypoxia generated by the procedure and involved in activation of the TAE-associated tumor angiogenesis. HIF-1{alpha} might represent a promising therapeutic target for antiangiogenesis in combination with TAE against liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗