Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “New”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

First experiment at the Super Heavy Element Factory: High cross section of Mc 288 in the Am 243 + Ca 48 reaction and identification of the new isotope Lr 264

Here, we present results of the first experiment aimed at the synthesis of Mc isotopes in the 243 Am+ 48 Ca reaction performed at the new gas-filled separator DGFRS-2 online to the new cyclotron DC280 at the Super Heavy Element Factory at JINR. Fifty-five new decay chains of 288 Mc and six chains assigned to 289 Mc were detected. The α decay of 268 Db with an energy of 7.6–8.0 MeV, half-life of 16$^{+6}_{-4}$h, and a branch of 55$^{+20}_{-15}$% was registered for the first time, and a new spontaneously fissioning isotope 264 Lr with a half-life of 4.9$^{+2.1}_{-1.3}$h was identified. The cross section for the 243 Am( 48 Ca,3n) 288 Mc reaction was measured to be 17.1$^{+6.3}_{-4.7}$ pb, which is the largest value for the known superheavy nuclei at the island of stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detecting nanometer-scale new forces with coherent neutron scattering

Significant effort has been devoted to searching for new fundamental forces of nature. At short length scales (below approximately 10 nm), the strongest experimental constraints come from neutron scattering from individual nuclei in gases. The leading experiments at longer length scales instead measure forces between macroscopic test masses. We propose a hybrid of these two approaches: scattering neutrons off of a target that has spatial structure at nanoscopic length scales. Such structures will give a coherent enhancement to small-angle scattering, where the new force is most significant. This can considerably improve the sensitivity of neutron scattering experiments for new forces in the 0.1–100 nm range. We discuss the backgrounds due to Standard Model interactions and a variety of potential target structures that could be used, estimating the resulting sensitivities. We show that, using only one day of beam time at a modern neutron scattering facility, our proposal has the potential to detect new forces as much as 2 orders of magnitude beyond current laboratory constraints at the appropriate length scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlations among new CP violating effects in {delta}F=2 observables

We point out that the observed CP violation in B{sub d}-B{sub d} mixing, taking into account the measured ratio {delta}M{sub d}/{delta}M{sub s}, the recently decreased lattice value of the nonperturbative parameter B-circumflex{sub K} and an additional effective suppression factor {kappa}{sub {epsilon}}{approx_equal}0.92 in {epsilon}{sub K} neglected so far in most analyses, may be insufficient to describe the measured value of {epsilon}{sub K} within the standard model (SM), thus hinting at new CP violating contributions to the K-K and/or B{sub d}-B{sub d} systems. Furthermore, assuming that {delta}M{sub d}/{delta}M{sub s} is SM-like, the signs and the magnitudes of new-physics effects in {epsilon}{sub K} and in the CP asymmetries S{sub {psi}}{sub K{sub s}} and S{sub {psi}}{sub {phi}} may turn out to be correlated. For example, in a scenario with new CP phases in B{sub d} and B{sub s} mixings being approximately equal and negative, a common new phase {approx_equal}-5 deg. could remove the tension between {epsilon}{sub K} and S{sub {psi}}{sub K{sub s}} present in the SM and simultaneously accommodate, at least partly, the recent claim of S{sub {psi}}{sub {phi}} being much larger than the SM expectation. We emphasize the importance of precise determinations of V{sub cb}, B-circumflex{sub K}, F{sub K}, and {xi}{sub s}, to which the parameter {epsilon}{sub K} and its correlation with the CP violation in the B{sub d}-B{sub d} system are very sensitive.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New twist on excited dark matter: Implications for INTEGRAL, PAMELA/ATIC/PPB-BETS, DAMA

We show that the 511 keV gamma ray excess observed by INTEGRAL/SPI can be more robustly explained by exciting dark matter (DM) at the center of the galaxy, if there is a peculiar spectrum of DM states {chi}{sub 0}, {chi}{sub 1}, and {chi}{sub 2}, with masses M{sub 0}{approx}500 GeV, M{sub 1} < or approx. M{sub 0}+2m{sub e}, and M{sub 2}=M{sub 1}+{delta}M > or approx. M{sub 0}+2m{sub e}. The small mass splitting {delta}M should be < or approx. 100 keV. In addition, we require at least two new gauge bosons (preferably three), with masses {approx}100 MeV. With this spectrum, {chi}{sub 1} is stable but can be excited to {chi}{sub 2} by low-velocity DM scatterings near the Galactic center, which are Sommerfeld-enhanced by two of the 100 MeV gauge boson exchanges. The excited state {chi}{sub 2} decays to {chi}{sub 0} and nonrelativistic e{sup +}e{sup -}, mediated by the third gauge boson, which mixes with the photon and Z. Although such a small 100 keV splitting has been independently proposed for explaining the DAMA annual modulation through the inelastic DM mechanism, the need for stability of {chi}{sub 1} (and hence sequestering it from the standard model) implies that our scenario cannot account for the DAMA signal. It can, however, address the PAMELA/ATIC positron excess via DM annihilation in the galaxy, and it offers the possibility of a sharper feature in the ATIC spectrum relative to previously proposed models. The data are consistent with three new gauge bosons, whose couplings fit naturally into a broken SU(2) gauge theory where the DM is a triplet of the SU(2). We propose a simple model in which the SU(2) is broken by new Higgs triplet and 5-plet vacuum expectation values, giving rise to the right spectrum of DM and mixing of one of the new gauge bosons with the photon and Z boson. A coupling of the DM to a heavy Z{sup '} may also be necessary to get the right relic density and PAMELA/ATIC signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signals of new physics in the underlying event

LHC searches for new physics focus on combinations of hard physics objects. In this work we propose a qualitatively different soft signal for new physics at the LHC - the 'anomalous underlying event'. Every hard LHC event will be accompanied by a soft underlying event due to QCD and pileup effects. Though it is often used for QCD and Monte Carlo studies, here we propose the incorporation of an underlying event analysis in some searches for new physics. An excess of anomalous underlying events may be a smoking-gun signal for particular new physics scenarios such as 'quirks' or 'hidden valleys' in which large amounts of energy may be emitted by a large multiplicity of soft particles. We discuss possible search strategies for such soft diffuse signals in the tracking system and calorimetry of the LHC experiments. We present a detailed study of the calorimetric signal in a concrete example, a simple quirk model motivated by folded supersymmetry. In these models the production and radiative decay of highly excited quirk bound states leads to an 'antenna pattern' of soft unclustered energy. Using a dedicated simulation of a toy detector and a multipole analysis familiar in cosmic microwave background studies, we compare the signal to the expected backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New fixed-target experiments to search for dark gauge forces

Fixed-target experiments are ideally suited for discovering new MeV-GeV mass U(1) gauge bosons through their kinetic mixing with the photon. In this paper, we identify the production and decay properties of new light gauge bosons that dictate fixed-target search strategies. We summarize existing limits and suggest five new experimental approaches that we anticipate can cover most of the natural parameter space, using currently operating GeV-energy beams and well-established detection methods. Such experiments are particularly timely in light of recent terrestrial and astrophysical anomalies (PAMELA, Fermi, DAMA/LIBRA, etc.) consistent with dark matter charged under a new gauge force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino physics with dark matter experiments and the signature of new baryonic neutral currents

New neutrino states {nu}{sub b}, sterile under the standard model interactions, can be coupled to baryons via the isoscalar vector currents that are much stronger than the standard model weak interactions. If some fraction of solar neutrinos oscillate into {nu}{sub b} on their way to Earth, the coherently enhanced elastic {nu}{sub b}-nucleus scattering can generate a strong signal in the dark matter detectors. For the interaction strength a few hundred times stronger than the weak force, the elastic {nu}{sub b}-nucleus scattering via new baryonic currents may account for the existing anomalies in the direct detection dark matter experiments at low recoil. We point out that for solar-neutrino energies, the baryon-current-induced inelastic scattering is suppressed, so that the possible enhancement of a new force is not in conflict with signals at dedicated neutrino detectors. We check this explicitly by calculating the {nu}{sub b}-induced deuteron breakup, and the excitation of a 4.4 MeV {gamma} line in {sup 12}C. A stronger-than-weak force coupled to the baryonic current implies the existence of a new Abelian gauge group U(1){sub B} with a relatively light gauge boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for new physics at the Hyper-Kamiokande experiment

We investigate the ability of the upcoming Hyper-Kamiokande (Hyper-K) neutrino experiment to detect new physics phenomena beyond the standard, three-massive-neutrinos paradigm; namely, the existence of a fourth, sterile neutrino or weaker-than-weak, nonstandard neutrino interactions. With both beam-based neutrinos from the Japan Proton Accelerator Research Complex (J-PARC) and atmospheric neutrinos, Hyper-K is capable of exploring new ranges of parameter space in these new-physics scenarios. We find that Hyper-K has comparable capability to the upcoming Deep Underground Neutrino Experiment (DUNE), and that combining both beam- and atmospheric-based data can clear up degeneracies in the parameter spaces of interest. We also comment on the potential improvement in searches for new physics if a combined analysis were performed using Hyper-K and DUNE data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of new marker genes from plant single‐cell RNA‐seq data using interpretable machine learning methods

Summary An essential step in the analysis of single‐cell RNA sequencing data is to classify cells into specific cell types using marker genes. In this study, we have developed a machine learning pipeline called single‐cell predictive marker (SPmarker) to identify novel cell‐type marker genes in the Arabidopsis root. Unlike traditional approaches, our method uses interpretable machine learning models to select marker genes. We have demonstrated that our method can: assign cell types based on cells that were labelled using published methods; project cell types identified by trajectory analysis from one data set to other data sets; and assign cell types based on internal GFP markers. Using SPmarker, we have identified hundreds of new marker genes that were not identified before. As compared to known marker genes, the new marker genes have more orthologous genes identifiable in the corresponding rice single‐cell clusters. The new root hair marker genes also include 172 genes with orthologs expressed in root hair cells in five non‐ Arabidopsis species, which expands the number of marker genes for this cell type by 35–154%. Our results represent a new approach to identifying cell‐type marker genes from scRNA‐seq data and pave the way for cross‐species mapping of scRNA‐seq data in plants.

54 ENVIRONMENTAL SCIENCES↗

New York State Climate Impacts Assessment Chapter 01: Introduction

Abstract New York State's climate is changing. Temperatures are rising, precipitation is increasing, sea levels are rising, and extreme weather events are becoming more frequent and severe. Over time, these changes are projected to worsen. The New York State Climate Impacts Assessment provides a science‐based analysis of what to expect from climate change in New York. Working with partners across the state, the team assembled to produce this assessment reviewed the latest science and modeling to project and characterize what New York State's climate is likely to look like in the future and how this will affect natural systems, society, and various sectors of the economy. The assessment will enable decision‐makers at all levels—from individual residents, businesses, and landowners to municipal and state government agencies—to better understand and make informed choices about how to plan and prepare for climate change.

Science & Technology - Other Topics↗

Combining RAVEN, RELAP5-3D, and PHISICS for Fuel Cycle and Core Design Analysis for New Cladding Criteria

The Nuclear Regulatory Commission (NRC) has considered revision of 10 CFR 50.46C rule to account for the effects of burn-up rate in future analysis of reactor accident scenarios so that safety margins may evolve with the operation and reloading of the reactor as dynamic limits. In order to find these limiting conditions, both cladding oxidation and maximum temperature must be cast as functions of fuel exposure. It is computationally intensive to run a plant model through a long duration operational transient to the time of fuel reload, and this must be repeated for each reload until the time of the accident scenario. Moreover, fuel reload patterns may differ in many ways so that calculations with many different core configurations must be considered. To perform such new analyses in a reasonable amount of computational time with good accuracy, Idaho National Laboratory (INL) has developed new multi-physics tools by combining existing codes and adding new capabilities. The Parallel Highly Innovative Simulation INL Code System (PHISICS) toolkit for neutronic and reactor physics is coupled with the Reactor Excursion and Leak Analysis Program (RELAP5-3D) for the Loss of Coolant Accident (LOCA) analysis and RAVEN for the Probabilistic Risk Assessment (PRA) and margin characterization analysis. Expansion of code capability was also necessary. For RELAP5-3D to process a single sequence of cores in a continuous run required modification of RELAP5-3D to restart a sequence of input decks, each with a slightly modified neutronics model or thermal-hydraulic flow region and culminating in an accident scenario. A new multi-deck input processing capability was developed and verified for this analysis. In conclusion, the combined RAVEN/PHISICS/RELAP5-3D tool is used to analyze a typical Pressurized Water Reactor (PWR).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unique and massive Chernobyl cranes for deconstruction activities in the new safe confinement

On 26 April 1986, the worst nuclear power plant accident in history occurred at the Chernobyl plant in Ukraine (then part of the Soviet Union). The destruction of Unit 4 sent highly radioactive fallout over Belarus, Russia, Ukraine, and Europe. The object shelter-a containment sarcophagus-was built in November 1986 to limit exposure to radiation. However, it has only a planned 25-year lifespan and would probably not survive even a moderate seismic event in a region that has more than its share of such events. It was time to take action. One of the largest tasks that are in progress is the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant Unit. One of the major mechanical handling systems to be installed in the new safe confinement is the Main Cranes System. The planned decontamination and decommissioning or dismantling activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the new safe confinement, will require large and sophisticated cranes. The article will focus on the current progress of the new safe confinement and of the main cranes system for the decommissioning or dismantling activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New RF Control System for the 12 GeV Energy Upgrade of the CEBAF Accelerator at Jefferson Lab

The CEBAF Accelerator at Jefferson Lab presently consists of 50 MeV injector, two anti-parallel superconducting linacs and two arcs for transporting beam between the linacs. By the mid-1990s, the accelerator was providing electrons up to 5.75 GeV. The 12 GeV Upgrade is a major accelerator project aimed at doubling the energy by adding 10 (five per linac) new high gradient cryomodules, each providing 100 MV of field. The new cryomodule will consist of eight 7-cell superconducting cavities operating at an average accelerating gradient of 19.5 MV/m and with an external Q=3.2 x 10^7. The high gradient, very high quality factor and large Lorentz detuning coefficient (KL up to 4) pose significant challenges beyond what the present analog low level RF (LLRF) control systems can handle reliably; therefore, a new digital LLRF control system has been developed. The main highlights of the new RF Control system include: a RF front-end with low temperature drift and good linearity, a large FPGA

43 PARTICLE ACCELERATORS↗

6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator

New technical developments constantly aim at improving the outcome of radiation therapy. With the use of a computer-controlled multileaf collimator (MLC), the quality of the treatment and the efficiency in patient throughput is significantly increased. New MLC designs aim to further enhance the advantages. In this article, we present the first detailed experimental investigation of the new 160 MLC{sup TM}, Siemens Medical Solutions. The assessment included the experimental investigation of typical MLC characteristics such as leakage, tongue-and-groove effect, penumbra, leaf speed, and leaf positioning accuracy with a 6 MV treatment beam. The leakage is remarkably low with an average of 0.37% due to a new design principle of slightly tilted leaves instead of the common tongue-and-groove design. But due to the tilt, the triangular tongue-and-groove effect occurs. Its magnitude of approximately 19% is similar to the dose defect measured for MLCs with the common tongue-and-groove design. The average longitudinal penumbra measured at depth d{sub max}=15 mm with standard 100x100 mm{sup 2} fields is 4.1{+-}0.5 mm for the central range and increases to 4.9{+-}1.3 mm for the entire field range of 400x400 mm{sup 2}. The increase is partly due to the single-focusing design and the large distance between the MLC and the isocenter enabling a large patient clearance. Regarding the leaf speed, different velocity tests were performed. The positions of the moving leaves were continuously recorded with the kilovoltage-imaging panel. The maximum leaf velocities measured were 42.9{+-}0.6 mm/s. In addition, several typical intensity-modulated radiation therapy treatments were performed and the delivery times compared to the Siemens OPTIFOCUS MLC. An average decrease of 11% in delivery time was observed. The experimental results presented in this article indicate that the dosimetric characteristics of the 160 MLC are capable of improving the quality of dose delivery with respect to precision and dose conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards new functional nanostructures for medical imaging

Nanostructures represent a promising new type of contrast agent for clinical medical imaging modalities, including magnetic resonance imaging, x-ray computed tomography, ultrasound, and nuclear imaging. Currently, most nanostructures are simple, single-purpose imaging agents based on spherical constructs (e.g., liposomes, micelles, nanoemulsions, macromolecules, dendrimers, and solid nanoparticle structures). In the next decade, new clinical imaging nanostructures will be designed as multi-functional constructs, to both amplify imaging signals at disease sites and deliver localized therapy. Proposals for nanostructures to fulfill these new functions will be outlined. New functional nanostructures are expected to develop in five main directions: Modular nanostructures with additive functionality; cooperative nanostructures with synergistic functionality; nanostructures activated by their in vivo environment; nanostructures activated by sources outside the patient; and novel, nonspherical nanostructures and components. The development and clinical translation of next-generation nanostructures will be facilitated by a combination of improved clarity of the in vivo imaging and biological challenges and the requirements to successfully overcome them; development of standardized characterization and validation systems tailored for the preclinical assessment of nanostructure agents; and development of streamlined commercialization strategies and pipelines tailored for nanostructure-based agents for their efficient translation to the clinic.

60 APPLIED LIFE SCIENCES↗

Validation for 2D/3D registration II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set

Purpose: A new gold standard data set for validation of 2D/3D registration based on a porcine cadaver head with attached fiducial markers was presented in the first part of this article. The advantage of this new phantom is the large amount of soft tissue, which simulates realistic conditions for registration. This article tests the performance of intensity- and gradient-based algorithms for 2D/3D registration using the new phantom data set. Methods: Intensity-based methods with four merit functions, namely, cross correlation, rank correlation, correlation ratio, and mutual information (MI), and two gradient-based algorithms, the backprojection gradient-based (BGB) registration method and the reconstruction gradient-based (RGB) registration method, were compared. Four volumes consisting of CBCT with two fields of view, 64 slice multidetector CT, and magnetic resonance-T1 weighted images were registered to a pair of kV x-ray images and a pair of MV images. A standardized evaluation methodology was employed. Targets were evenly spread over the volumes and 250 starting positions of the 3D volumes with initial displacements of up to 25 mm from the gold standard position were calculated. After the registration, the displacement from the gold standard was retrieved and the root mean square (RMS), mean, and standard deviation mean target registration errors (mTREs) over 250 registrations were derived. Additionally, the following merit properties were computed: Accuracy, capture range, number of minima, risk of nonconvergence, and distinctiveness of optimum for better comparison of the robustness of each merit. Results: Among the merit functions used for the intensity-based method, MI reached the best accuracy with an RMS mTRE down to 1.30 mm. Furthermore, it was the only merit function that could accurately register the CT to the kV x rays with the presence of tissue deformation. As for the gradient-based methods, BGB and RGB methods achieved subvoxel accuracy (RMS mTRE down to 0.56 and 0.70 mm, respectively). Overall, gradient-based similarity measures were found to be substantially more accurate than intensity-based methods and could cope with soft tissue deformation and enabled also accurate registrations of the MR-T1 volume to the kV x-ray image. Conclusions: In this article, the authors demonstrate the usefulness of a new phantom image data set for the evaluation of 2D/3D registration methods, which featured soft tissue deformation. The author's evaluation shows that gradient-based methods are more accurate than intensity-based methods, especially when soft tissue deformation is present. However, the current nonoptimized implementations make them prohibitively slow for practical applications. On the other hand, the speed of the intensity-based method renders these more suitable for clinical use, while the accuracy is still competitive.

60 APPLIED LIFE SCIENCES↗

TU-F-BRE-09: Towards the Establishment of Dosimetric References in Small Fields Using the New Concept of Dose-Area Product

Purpose: To establish dosimetric references of absorbed dose in water in radiation fields smaller than 2 cm used in radiotherapy thanks to a new methodology based on the use of dosimeters larger than the field size. Methods: A new graphite calorimeter was constructed with a large sensitive volume (diameter of the core: 30 mm). This primary dosimeter was fully characterized and compared to previous LNE-LNHB graphite calorimeters in a 60Co large field. A specially designed graphite parallel-plate ionization chamber with a 30 mm collecting electrode was also assembled and tested. Measurements were then conducted in two 6 MV small circular fields of 2 cm and 1 cm diameter respectively, using the new concept of dose-area product instead of punctual dose commonly used in radiotherapy. Results: The dose rate established in a large 60Co field with the new calorimeter is in agreement within 0.4% with previous calorimeters. The ionization chamber shows good characteristics except for a 0.06% drift per hour in water. The ratio of calorimetric against ionometric measurements in the 2 cm diameter field is 1.1% higher than the one in the 1 cm diameter field (with respectively 0.30% and 1.03% type A uncertainty for each field). Conclusion: Results presented here highlight the possibility of measuring dose-area products in small fields with a graphite calorimeter and a parallel-plate ionization chamber. Measurements in a 0.75 cm diameter field are already underway to confirm the trend observed in the 2 cm and 1 cm diameter fields. The last step to establish precise dosimetric references in small fields is to calculate correction factors thanks to Monte Carlo simulations.

07 ISOTOPE AND RADIATION SOURCES↗

The Octavius1500 2D ion chamber array and its associated phantoms: Dosimetric characterization of a new prototype

Purpose: The purpose of the study is to characterize the prototype of the new Octavius1500 (PTW, Freiburg, Germany) 2D ion chamber array, covering its use in different phantom setups, from the most basic solid water sandwich setup to the more complex cylindrical Octavius{sup ®} 4D (Oct4D) (PTW) phantom/detector combination. The new detector houses nearly twice the amount of ion chambers as its predecessors (Seven29 and Octavius729), thereby tackling one of the most important limitations of ion chamber (or diode) arrays, namely the limited detector density. The 0.06 cm{sup 3} cubic ion chambers are now arranged in a checkerboard pattern, leaving no lines (neither longitudinally nor laterally) without detectors. Methods: All measurements were performed on a dual energy (6 MV and 18 MV) iX Clinac (Varian Medical Systems, Palo Alto, CA) and all calculations were done in the Eclipse treatment planning system (Varian) with the Anisotropic Analytical Algorithm. First, the basic characteristics of the 2D array, such as measurement stability, dose rate dependence and dose linearity were investigated in the solid water sandwich setup. Second, the directional dependence was assessed to allow the evaluation of the new Octavius2D phantom (Oct2D{sup 1500}) for planar verification measurements of composite plans. Third, measurements were performed in the Oct4D phantom to evaluate the impact of the increased detector density on the accuracy of the volumetric dose reconstruction. Results: While showing equally good dose linearity and dose rate independence, the Octavius1500 outperforms the previous models because of its instantaneous measurement stability and its twofold active area coverage. Orthogonal field-by-field measurements immediately benefit from the increased detector density. The 3.9 cm wide compensation cavity in the new Oct2D{sup 1500} phantom prototype adequately corrects for directional dependence from the rear, resulting in good agreement within the target dose. Discrepancies may arise towards the sides of the array because of uncompensated lateral beam incidence. The beneficial impact of the detector density is most prominent in the Oct4D system, for which the average pass rate (PR) is now nearly 100% (99.31 ± 0.37) when using gamma criteria of 2%G,2 mm (10% dose threshold). In search of gamma analysis criteria that are not too lenient to detect possibly relevant deviations, the authors conclude that for our radiotherapy environment, the authors choose to adopt 3%L,3 mm PR97% (threshold 10%) criteria for the Oct2D{sup 1500}/Octavius1500 system and 2%L,3 mm PR97% (threshold 10%) for the Oct4D/Octavius1500 system. These are first line pass/check criteria and plans that fail are not necessarily rejected, but submitted to a more detailed investigation. Conclusions: When irradiated from the front, the Octavius1500 array has two main advantages over its 729 predecessors: its instantaneous measurement stability and-–most importantly—its twofold detector density. In the Oct2D1500 phantom, these advantages are counterbalanced by the more pronounced directional dependence. The measurement-based 3D dose reconstruction in the Oct4D system, however, benefits considerably from the higher detector density in the checkerboard panel design.

07 ISOTOPE AND RADIATION SOURCES↗